Sei sulla pagina 1di 24

INNEXIV M2M PLATFORM

ADVANCE REMOTE VISIBILITY & CONTROL SYSTEM


We are Machine-to-Machine (M2M) Platform We provide end-to-end visibility into remote
builders infrastructure anytime, anywhere

We help industries to reduce operational


We are Energy Management company
expenditure (OpEx)

We are hardware designers We provide business intelligence

We provide powerful analytics to enable businesses


We are software developers
to take informed decision
What we can’t do right now without RMS?
When you ask for a report, how long does it take.
Do we have control over our vendors, Is there any mechanism to monitor and track vendor’s performance?

Do we have a mechanism to define, track and analyze KPIs

Do we know ; how much fuel is being consumed on our network? How much fuel is being stolen? Today/ This Month/ This Year?

How many generators are in bad condition on the network which need maintenance?

Do we know how much energy is being consumed on our network at this moment?
How long does it take to collect true data for Root Cause Analysis of a site gone down? can we even do it?

Can we get a notification regarding the sites running on low fuel, low generator battery?

Are we pouring ample amount of fuel on our sites? Is it less or more than needed?

Our data is manually recorded, Is it correct? How do we make sure our data is correct?

Do we need actually an army of people to make reports? or a system can do it better for us?

Our limitations are too many to operate efficiently, we are in dire need to deploy systems and
technologies on our RAN nodes for better, secure and real-time data
Fuel Generator Battery Site Security

• 30% fuel stolen • Security guards • Battery usage, • Site Rectifiers are
before poured usually tamper with health, SOC, drain prone to tampering
breakers and shift event, charging and theft
• No check on the fuel load to batteries discharging patterns
poured against are not visible • No mechanism to
amount claimed by • Actual generator run deter vandalism
fueling vendor hours are not visible • Battery life spans
for such events and affects due to over • No access control
• Due to unavailability fuel is easily stolen usage,
of low fuel alarm,
network goes down • No visibility to
due to low fuel monitor gen-battery
issues voltage and network
goes down due to
poor performing
DGs
No. . .
• Mechanism for Vendor management
• KPI monitoring
• Real-time visibility, consolidated visibility into network health
• Visibility into battery health, charging/discharging states and
drain events
Grid available Grid Outage
• Information for analytics
Site Load on • Fault identification before event
Batteries
Temporarily • Power source status and usage information
• Battery charging/discharging data
• Real-time fuel level
• Fuel loss data
• Environmental (temperature, humidity, water, smoke)
Generator
Running and
• Real-time alerts, notifications or diagnostic
stable
• Visibility into Access control & site security
• Real time visibility and monitoring
• Remote intelligence • Energy efficiency


Decreased network down time
Decreased Generator run hours • OpEx reduction


Automated control programs (ACPs)
Remote Battery health test
• Operational excellence
• Reduced fuel usage • Revenue enhancement
• Theft control
• Refueling plan/move plan

RMS
EFFECTIVE SIGNIFICANT OPEX REDUCTION
MANAGEMENT OF THE
ULTIMATE INSTANT BY 68%
Grid available Grid Outage
POWER SOURCE
Grid available

Battery Charged
And grid not
available

ENSURING GENERATOR SOUND BATTERY MONITORING IS


Battery Drained
RUNS WHEN IT NEEDS TO and Grid not
available
CRITICAL TO AVOID REVENUE LOSS AND
FOR SUBSCRIBER RETENTION
Reports Graphs Diagnostics Alerts
INNEXIV offers advance REMOTE
Alerts Reports Graphs Diagnostics
Diagnostics
MONITORING AND CONTROL
Platform (RMS) for efficient visibility
and monitoring of
Energy NOC
RADIO ACCESS NETWORK (RAN)

GPRS
RMS Modules
RPM, Oil Pressure, Oil
Temp, Exhaust Temp, Coolant, Vibration,
OBD2 Grid Generator
Monitoring Management

Level, Consumption Rate,


Consumption Test, Refill, Theft, Leakage,
Forecast

Charge/discharge, TBV,DCI, Fuel Management


Battery
DoD, temperature Management

: Access control, motion


detection, image capture, cabinet door,
buzzer
Door Fire Temp Humidity Smoke HVAC Security Video
POWER INFRASTRUCTURE INTELLIGENT MANAGEMENT AND PRECISE OPERATION
Monitor Grid Power, Manage power resources Complete Enterprise view

GENERATOR MANAGEMENT & CONTROL SMART POWER UTILIZATION


Full remote control, maintenance Grid power theft notification

FUEL MANAGEMENT OpEx EFFICIENCY


Fuel theft alarms, consumption, refilling, forecasting Control the visible and invisible OpEx contributors

BATTERY MONITORING ANALYTICS


Management, Individual cell, Reduce DoD variances Heuristic Algorithms, Predictive Analysis, Performance optimization

ENVIRONMENTAL MONITORING HISTORIC TRENDING


Track all facets of environments at remote sites Performance tracking

SECURITY
Ensure safety from intruders and mitigate internal risks

POWER GENERATOR FUEL MANAGEMENT BATTERY RECTIFIER MULTIPLE


INFRASTRUCTURE MANAGEMENT & MANAGEMENT MANAGEMENT GENERATORS
CONTROL

AUTO MAINS FAILURE COMPLETE EMERGENCY ENVIRONMENTAL SECURITY AND ACCESS HYBRID SOLUTIONS
INTEGRATED GENERATOR DISPATCH MONITORING
POWER
SOLUTION
INNEXIV RAN-RMS Functions
Power Management Battery Management Generator Management
Monitoring: Monitoring: Monitoring:
• Grid power status • Voltage • Generator power status
• Voltage (3Φ) • Current • Voltage (3Φ)
• Current (3Φ) • Status (charging /discharging) • Current (3Φ)
• Frequency • Battery usage hours • Frequency
• Power factor (3Φ) • Battery drain events • Power factor (3Φ)
• Missing phase(s) • Number of cycles • Missing phase(s)
• Phase Imbalance • Battery cabinet temperature • Phase Load Imbalance (3Φ)
• Kwh in real-time • Battery cabinet door status • Generator run hours
• Kvarh in real time • Battery cabinet humidity • KWh/liters
• Instantaneous: • Cabinet AC monitoring (on/off) – optional upgrade • Generator Battery Voltage
o active power • Depth of discharge (DoD) Controls:
o reactive power Controls: • Automated control programs (ACP)
o apparent power • Remote battery test o Delayed generator start-up
• Outage frequency Environmental Management o Generator sequencing
Controls: (optional only) • Emergency start/stop
• Remote emergency cut Monitoring: • Remote generator test
Fuel Management • Outdoor- temperature o Generator stop on basis of battery SOC
Fuel Tank: • Indoor -temperature Engine:
• Fuel level • Humidity • Failed to start
• Fuel usage • Water leakage • Fuel consumption
Fuel Refill: • Lighting control • RPM
• Fuel refills • Day/night • Expansion for Enhanced Generator monitoring and control
• Frequency of refills • Smoke detector ATS/AMF
Fuel Pilferage/Theft: • Gas leak Monitoring:
• Fuel theft (sudden drop) • Rain • ATS State (power source stat)
Secure Re-fuelling: • Hazardous gases (various) Controls:
• Re-fuelling Plan (move plan) Air conditioner: • ATS Contactor Control
• On-spot audit of poured vs. received amount of fuel • Status
• Invoice consolidation • Sequencing
Communications Controls (For indoor sites): Rectifier
Wired: • AC turn on/off Monitoring:
• RS-485/RS-4xx, PWM, RS-232 (board-to-board comm) • Forced ventilation • Voltage
• Ethernet • Air conditioner sequencing • Current
• INNEXIV Proprietary protocols SITE SECURITY • Rectifier State
Wireless: • Access control • Total Load (Batteries + site load)
• INNEXIV proprietary protocols • Motion detection
• Door status
• Options available: GPRS, SMS, CDMA, 3G, 4G/LTE,
433/488Mhz, LoRa, Bluetooth 4.0, Wi-Fi, RF-Mesh (self-healing), • Shock sensor
Point-to-point (LOS) • Image capture
• Buzzer
Real-time Emergency Control

Trends Start on Demand

Interactive Reports Generator Test


MONITORING CONTROL
Real-time Alerts Battery Test

High Accuracy Automated Control

Theft Load Test

ANALYTICS

Intuitive Dashboards
Problem Reporting Heuristic Algorithms
Applied data Processing
TIMELY PREVENTIVE
Incident Response

Preventive Maintenance
Predictive Analytics MAINTENANCE
Alert Management
Performance Optimization
INSTEAD OF RESCUE
Real-time Analytics for Alert
Management
Events Operator’s response WITHOUT RMS WITH RMS

Vendor claims x liters


of fuel refill while in Site guard informs Operator that Pay the amount claimed by fueling “Pay as poured” and reclaim amount for
reality less fuel was fueling is done correctly vendor fuel shortage
poured

RMS identifies discrepancy in jerrycan,


Operator considers 1 jerrycan = 30
Fuel through Jerrycan Pay for 30 liters against 1 jerrycan Operator now gets accurate volume in
liters
jerrycan

Fuel pilferage during Operator has no RMS identified fuel pilferage during
No one can be held accountable as such
maintenance/ site mechanism/visibility to identify such maintenance activity and maintenance
events can not be identified
activities events teams can be held accountable
Events Operator’s response WITHOUT RMS WITH RMS

Delayed response due no real-time Inquire site guard and believe what he Real-time alarm is generated to take
Battery theft
visibility says correct action

RMS reports fuel presence in fuel tank


Generator not
Site guard reports no fuel in fuel tank Send fueling team to site for fuel refill and site guard can be held accountable
running
for wrong statement

RMS can identify such events to allow


Grid/Gen overlapping No visibility Increased OpEx
Operator to re-dimension power systems

Gen-battery not Site goes down because generator cannot RMS generates low battery alarm for
No visibility
charging start when needed early notification
Events Operator’s response WITHOUT RMS WITH RMS

INNEXIV Smart meters provide real-time


Commercial Energy
Can not be cross referenced Over payment consolidated visibility; data can be cross-
Over-billing
referenced

ROI model cannot be made as the Identify site with high frequency of
Gen running due to
Should an APS be installed? number of events occurring cannot be missing phase and rollout precisely to
Grid phase miss
captured apply investment efficiently

Sites cannot be pinpointed, a proper RMS can identify such sites with
Over and Under Grid Which sites need an LC to be
model cannot be made without frequent over and under voltage
voltages installed?
identifying the vulnerable sites problems to deploy LC
Events Operator’s response WITHOUT RMS WITH RMS

Battery swap without understanding


No mechanism to monitor battery Clearly understand battery DOD and overall
Battery Health actual health; heavy investments
health and improve its life span health state and replace at the right time
without proper clarity

RMS provides accurate Kwh usage patterns


Energy consumption Estimations based on data Manual data records are error prone
across network which can be extrapolated for
across network collection and take too long to compile
forecasting instantly

RMS gives various inputs to generate refueling


Estimation based periodic Fueling more than what is required plan for a region/cluster. These include:
Refueling plan refueling done irrespective of gives opportunity to fueling vendor • Power source utilization reports
site’s fuel requirement and site guard for pilferage • Load shedding reports
• Fuel usage patterns
APPLICATION
GRID POWER
GENERATOR
ENOC-DASHBOARD FUEL STATISTICS
GENERATOR STATISTICS GRID STATISTICS
ALARM DASHBOARD
www.innexiv.com contactus@innexiv.com

24