Sei sulla pagina 1di 9

DETAILED DESIGN REPORT

ON
G+9 RESIDENTIAL BUILDING - MYSORE

By
V. ANIL KUMAR
1
CONTENTS

1. Superstructure 3
2. Substructure 8

2
1. Superstructure

Structure Information:
No. of Floors 14(Basement+Stilt+G+9+Terr+OHT)
Total Height 40.75
Plan Dimensions 26.95x24.2m
Floor Height Basement – 2.85m
Stilt – 3m
Typical – 2.9m
Slenderness Ratio 1.68

Architectural Plan

3
Structure Layout

Materials:
Concrete M35, M40
Steel HYSD500

Sections:
Columns 300x450mm, 300x650mm
Beams 150x300mm, 300x600mm
Slabs 125mm, 150mm, 200mm
Walls 230mm

Shell Loads:
Load Set Dead Load (kN/m2) Live Load (kN/m2)
Habitual 1.5 2
LMR 12 0.75
Wash 3 2
Terrace 3 1.5
OHT 16 0.75
Stair Case 3 3
Lobby 1.5 3
Parking 0.5 4

4
Frame Loads:
External Wall 5.29 kN/m2
Internal Wall 3.45 kN/m2
3.9 kN/m2
Parapet 1.5 kN/m2

Earthquake Load: As per IS 1893:2016 part 1


Zone Factor II
Importance Factor 1.0
Response Reduction Factor 5
Soil Type II (Medium)

5
Mass Source DL-1, LL-0.25, LL-0.5
Time Period Tx-0.706s, Ty-0.745s
Base Shear Sx-1419.63 kN, Sy-1345.32 kN

Wind Load: As per IS 875:2015 part 3


Basic Wind Speed 33
Class Type C
Terrain Category III
Probability Factor, k1 1.0
Terrain, height, structure size factor, k2 1.12
Topography factor, k3 1.0
Shear Wx-437.417 kN, Wy-437.417 kN

P-Delta: P-Delta with 1.5DL is considered for Analysis.

Property Modifiers:
Section Unfactored Loads (Service) Factored Loads (Strength)
Columns 1.0Ig 0.7Ig
Beams 0.5Ig 0.35Ig
Slabs 0.35Ig 0.25Ig
Walls 1.0Ig 0.7Ig

Stability Checks:
Check Load Case Allowable Observed
Inter Story Drift ( Service) (mm) Spec X 0.0116 0.0008 SAFE
Spec Y 0.0116 0.0013
Max. Def. against EQ (Service) (mm) Spec X 163 23.24 SAFE
Spec Y 163 34.85
Max. Def. against Wind (mm) Wx 75.5 4.14 SAFE
Wy 75.5 4.14
Vertical deflection (mm) DL+LL 14.714 12.802 SAFE

Modal Analysis:

a) Guideline for Fundamental time period = 0.1 x N =0.1 X 14 = 1.4


Time period = 1.655s

b) No. of modes given should be given in such a way that around 95% to 98% modal
mass participation ratio shall be achieved.
Sum UX=99.14%
Sum UY=99.59%

c) 1st mode of vibration is performed to be translation mode

6
RZ = 1.09% which is less than 5 %

Torsional Irregularity: No Torsion Irregularity observed.

Buckling: Buckling is not considered because Slenderness ratio of Building is less than 4

7
2. Substructure Details:
Structure Information:

SBC 200 kN/m2


Nature of Foundation Raft Foundation
Depth of Foundation 1100mm
Size of Foundation 26.1x32.3m
Spring Type Area Spring
Spring Constant 8000 KN/m³
Depth of Water Table 3m

Materials:

Grade of Concrete M40


Grade of Steel HYSD500

Checks:

Check Load Case Allowable Observed


Settlement DL+LL 25 mm 21.96 mm SAFE
Soil Pressure DL+LL 200 kN/m2 175.72 kN/m2 SAFE
Punching Shear Service Envlp 1 0.86
0.625(SW-1.95m) 0.44 N/mm2 SAFE
Crack Width Service Envlp 0.2 mm 0.17 mm SAFE
Flotation 0.9DL+1.4WL NO

8
Reinforcement Cover: As per IS 456:2000

Slabs 25 mm
Beams 30 mm
Columns 40 mm
Walls 40 mm
Foundation Top-50mm, Bottom-60mm,

Load Combinations:

For Strength

 1.5DL + 1.5LL
 1.2DL + 1.2LL + SPEC X/Y
 0.9DL + 1.2LL + SPEC X/Y
 0.9DL + 1.5SPEC X/Y
 1.5DL +/- 1.5W X/Y
 1.2DL +1.2LL +/-1.2W X/Y
 1.5DL +/- 1.5W X/Y
 1.2 DL +/- 1.2LL +/- 1.2W X/Y
 0.9 DL +/- 1.5W X/Y

For Service

 1DL + 1LL
 1DL + 1SPEC X/Y
 1DL + 0.8LL + 0.8SPEC X/Y

List of Codes used:

Code Details
IS-456 2000 For RCC Design
IS-1893 Part-1, 2016 For Earthquake Loads
IS-875 Part-1, 1987 For Dead Loads
IS-875 Part-2, 1987 For Live Loads
IS-875 Part-3, 2015 For Wind Loads
IS-13920 2016 For Ductile Detailing

Softwares used:

Superstructure ETABS 2016


Substructure SAFE 2016