Sei sulla pagina 1di 3

Dewar M750 fibre Optic Interface

Designed and manufactured in Australia

The M750 easily converts 4 wire G703 co-directional to either


multi mode or single mode fibre

The Dewar M750 Fibre Optic Interface (FOI) The 19”, 1U high case can house up to 7 modules.
isdesigned to allow simple and easy transmission Up to 6 FOI multimode modules (750-3) can be
of co-directional G703 64kbit 4 wire electrical powered by 1 power supply module. Up to 3 FOI
over fibre in information systems and industrial single mode modules (750-8) can be powered by 1
applications. power supply module. This facilitates for mix and
match of FOI and power supply modules which
allows complete isolation of circuits. The customer
Put simply, the M750 converts 4 wire G703 co- can specify module locations at ordering, or can
directional to either multimode or single mode locate the module positions within the rack at
fibre. installation.

These units offer a minimum 500VDC


isolation between I/P and O/P data signals Key Features:
and earth. Offering the highest level of  G703, 64Kbit co-directional signal channels
reliability, the Dewar M750 allows the user  ST connectors for secure connection
a level of flexibility to suit their individual  850 to 890 nm multimode Tx and Rx
needs.  1265 to 1380 nm singlemode Tx and Rx
 Isolates communications from ground potential
rise and EMI/RFI
Each FOI utilises a pair of 850nm multimode  Mix and match modules to suit applications
or 1350nm single mode fibre optic cables  1U high - Saving you rack space
terminated with ST style connectors.  Up to 6 individual FOI channels per rack

Fully designed and manufactured at our premises in Croydon, Victoria.

32-34 Taylors Road, Croydon, Victoria, 3136, AUSTRALIA


Enduring High Quality Products
(03) 9725 3333 sales@dewar.com.au www.dewar.com.au
Specifications

FIBRE OPTIC INTERFACE POWER SUPPLY


Multimode Input: 20 to 60VDC, 90-180VDC & 200-300VDC
Receiver: ST 62.5/125um fibre cable LED Indicator: Power out
Transmitter: ST 62.5/125um fibre cable Protection: Input fuse, Current Limit & Short circuit
Wavelength: 810 to 890 nm HFD: IEC255-22-1 CI 11
Optical Att: 12dB max. Transmitter to Receiver Impulse: IEC255-5CI 111
Up to 2kms depending on fibre quality PSU Burden: 3 watts max (1.5 typ’) per PSU
FO Burden: 5 watts max (3.5 typ’) per FO interface
Singlemode
Receiver: ST 9/125um fibre cable GENERAL
Transmitter: ST 9/125um fibre cable Isolation: 500VDC between:
Wavelength: 1265 to 1380nm 1/ Data Signals & PSU earth
Optical Att: 12dB max. Transmitter to Receiver 2/ I/P & O/P Data signals & earth
Up to 20kms depending on fibre quality
Temp Operating: -5 to 50°c
G703 ELECTRICAL CONNECTION Temp Storage: -20c to + 85
Co-Directional: G703, 64KBit Relative Humidity: 5% to 95% at +40c. Non condensing
Termination: 120 ohm Altitude: 0 to 3000 metres
Response delay: <500nSec
LED Indicators: Data & Signal present. Rx & Tx Power MECHANICAL
Case: 19” standard rack width x 1U high
Overall size: 482.6mm x 43.6mm x 160mm depth

Ordering Example

32-34 Taylors Road, Croydon, Victoria, 3136, AUSTRALIA


Enduring High Quality Products
(03) 9725 3333 sales@dewar.com.au www.dewar.com.au
Dewar M750 fibre Optic Interface Installation

WARNING!
This product may utilise high voltages.
Installation and maintenance should only be carried out by qualified personnel.

Image: Rear view of M750

The M750 case is designed to be installed into a FOI and PSU modules are assembled on the same
standard 19” (482.6mm) wide rack of minimum footprint. Up to 7 modules can be mounted in a
1U height (44.5mm) the end brackets form part of single case. Up to 6 FOI modules can be powered by
the case. Mounting hardware is not supplied. 1 PSU. Due to power connection needs the extreme
left module as seen from the front can only house a
All connections are made to the rear of the case PSU card.
assembly. It is suggested a minimum distance of
150mm be allowed at the case rear for ease of A tally plate is provided to allow the installer to
cable connections. identify the position of each module.

LED Indicators: A green LED indicates power output


from the PSU and power applied to a fitted FOI.
Module. Yellow (Tx & Rx) LEDs indicate data
transmit and receive.

32-34 Taylors Road, Croydon, Victoria, 3136, AUSTRALIA


Enduring High Quality Products
(03) 9725 3333 sales@dewar.com.au www.dewar.com.au