Sei sulla pagina 1di 2

CONTROL PARAMETERS

M <----- Analysis Type (HARMONIC/SPECTRUM/MODES/TIMEHISTORY)


3 <----- Static Load Case for Nonlinear Restraint Status
500 <----- Stiffness Factor for Friction (0.0-Not Used)
0 <----- Max. No. of Eigenvalues Calculated (0 - Not Used)
33 <----- Frequency Cutoff (Hz)
LUMPED <----- Mass Model (LUMPED/CONSISTENT)
Y <----- Sturm Sequence Check on Computed Eigenvalues (Y/N)
6 <----- Estimated No. of Significant Figures in Eigenvalues
1E-12 <----- Jacobi Sweep Tolerance
1E10 <----- Decomposition Singularity Tolerance
0 <----- Subspace Size (0 - Not Used)
2 <----- No. to Converge Before Shift Allowed (0 - Not Used)
0 <----- No. of Iterations per Shift (0 - Pgm Computed)
0 <----- % of Iterations per Shift Before Orthogonalization
N <----- Force Orthogonalization After Convergence (Y/N)
N <----- Use Out-of-Core Eigensolver (Y/N)
100 <----- Frequency Array Spaces

LUMPED MASSES
Mass, Direction, Start, End, Inc
*EXAMPLE --> 1375.6 ALL 15 ...ADD MASS OF 1375.6 AT NODE 15
*EXAMPLE --> 0.0 ALL 105 .....DELETE ALL MASS FROM NODE 105
*EXAMPLE --> 0.0 ALL 5 15 5 ..DELETE ALL MASS FROM 5, 10 AND 15

SNUBBERS
Stiffness, Direction, Node, Cnode(Opt.)
* EXAMPLE --> 10000 X 50 ......Snubber at node 50 Stiffness=10000
* EXAMPLE --> 1E13 (1,0,1) 75 .Skewed 45 Deg. Snubber at 75
* EXAMPLE --> 1E13 Z 55 155 ...Z Snubber at 55, Connecting Node 155

EXCITATION FREQUENCIES
Start Frequency, End Frequency, Inc, Load Cycles
*EXAMPLE --> 1.1 ..........EXCITATION AT 1.1 HZ.
*EXAMPLE --> 1.1 3.1 1.0 ..EXCITATION AT 1.1, 2.1 & 3.1 HZ

HARMONIC FORCES
Force, Direction, Phase, Start, End, Inc
*EXAMPLE --> 1567.3 X 0.0 50 ...."X" LOAD AT 50 MAGNITUDE=1567.3

HARMONIC DISPLACEMENTS
Displacement, Direction, Phase, Start, End, Inc
*EXAMPLE --> 0.076 Z 0.0 85 ..."Z" DISPLACEMENT AT 85 = 0.076

FORCE SPECTRUM EDITING


Force, Direction, Node, Force Set #
* EXAMPLE --> 832.9 X 50 2 ..832.9 Load at 50 in X, Set #2.

DYNAMIC LOAD CASE SPECTRUM/TIME HISTORY CONTRIBUTIONS


Name, Factor, Direction, Start, End, Inc
DYNAMIC LOAD CASE # 1

STRESSTYPE(OCC)

STATIC/DYNAMIC COMBINATION CASES


Load case, Factor
*** NOTE *** No Static/Dynamic combination cases defined

SPECTRUM DEFINITIONS
* Note that: ELCENTRO thru UBCSOIL3 are RESERVED SPECTRUM NAMES
* that can be used without further definition!

ELCENTRO FREQ DISPL LOG LOG


*** NOTE *** Spectrum completely predefined
* Based on May 18, 1940 El Centro California earthquake
* N-S component. Applies to elastic systems with 5-10% damping.
* Taken from Biggs, "Introduction to Structural Dynamics".

1.60H.5 FREQ VEL LOG LOG


*** NOTE *** Spectrum completely predefined

* AEC Reg. Guide 1.60 Rev.1, Dec.1973 Horizontal Design Response


* Spectra for 0.5% critically damped system.

1.60H2 FREQ VEL LOG LOG


*** NOTE *** Spectrum completely predefined
1.60H5 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60H7 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60H10 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60V.5 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60V2 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60V5 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60V7 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined
1.60V10 FREQ VEL LOG LOG
*** NOTE *** Spectrum completely predefined

* Uniform Building Code Normalized Response Spectra


* SOIL TYPE 1 (Rock and Stiff Soil)
* SOIL TYPE 2 (Deep Cohesionless or Stiff Clay Soils)
* SOIL TYPE 3 (Soft to Medium Clays and Sands)

UBCSOIL1 PER ACC LIN LIN


*** NOTE *** Spectrum completely predefined
UBCSOIL2 PER ACC LIN LIN
*** NOTE *** Spectrum completely predefined
UBCSOIL3 PER ACC LIN LIN
*** NOTE *** Spectrum completely predefined
*** NOTE *** Input check completed without errors