COVER PAGE
Bringing World
Class Firefighting
Capabilities
to India.
COVER INSIDE
THE SMART RANGE 1
PAGE 01
2 CEASEFIRE
CEASEFIRE, A NAME
SYNONYMOUS WITH
FIRE SAFETY IN INDIA
PAGE 2
22 CEASEFIRE
HFC 227ea
FLOODING SYSTEM
PAGE 22
THE SMART RANGE 23
The detectors sense a rise in temperature above reach. This effectively ‘floods’ the area, reduces
normal, particles of smoke, or a change in air the concentration of oxygen in the air and
quality, and alert the Control Panel. Which, in efficiently puts out the fire. Being self-activated,
turn, activates the system and triggers a the system offers protection from fire 24 x7,
high-pressure solenoid valve that releases the whether anyone’s around or not.
HFC 227ea gas from seamless cylinders to the
nozzle via a flexible piping network. A hooter
goes off simultaneously, warning personnel to
clear the area while the extinguishing agent is Control Valve Discharge Smoke Detector
Panel Nozzle
dispersed.
The HFC 227ea Flooding System is designed The system comprises various components
to conform to IES 15519, the National Fire that come together to create an unbeatable
Protection Association (NFPA) 2001 and suppression system.
ISO/PF 20885 standards.
Pipes and Fittings Detection Devices The HFC 227ea Control Panel
PAGE 23
24 CEASEFIRE
PAGE 24
THE SMART RANGE 25
APPLICATION AREAS:
Server Rooms
PAGE 25
26 CEASEFIRE
The most prominent feature of CQRS is the dousing the fire instantaneously. Because the
specially designed heat-sensitive pneumatic extinguishing agent used is a clean agent*, this
polymer tubing. It’s connected at one end to a system is effective to combat any kind of fire.
Ceasefire extinguishing agent container, while the This revolutionary technology makes this system
rest of it runs unobtrusively throughout the area entirely self-activated, and requires no human
at risk. When the flame comes in contact with the intervention once it has been installed.
heat-sensitive tubing and reaches a temperature This makes it especially beneficial for
of 80° - 90°C, the tubing bursts open at that “microenvironments”, or areas where the fire
exact spot and forms a miniature nozzle. hazard is likely to be in an enclosed space (such
The pneumatic mechanism triggers the valve of as a server or a genset).
the extinguisher and sprays the extinguishing *HFC236fa and HFC227ea are UL Certified gases
agent out of the tube directly onto the flame,
PAGE 26
THE SMART RANGE 27
CUSTOM-MADE SOLUTIONS
CQRS operates on two different technologies In the Indirect system, the heat-sensitive
– Direct and Indirect. tubing only acts as a detection device. In the
event of a fire, the extinguishing agent is
In the Direct system, the heat-sensitive tubing
delivered through a steel pipe and sprayed
also acts as an extinguishing agent delivery
across the entire area through strategically
system. When a fire is detected, the tube
placed nozzles. Ideal for areas where there is
bursts at that point, forms a miniature nozzle
a chance of ignition of fires at multiple points.
and sprays the extinguishing agent. Ideal for
Both are available in low and high pressure
places where fires can break out in localised
variants.
areas.
Fire Extinguishing
Extinguishing Extinguishing
Agent
Agent Agent
Container Container
Alarm
DLP Valve
Agent Cylinder
Heat-sensing
Tube
The single heat-sensitive polymer tube is When it reaches 150° - 180°C, the heat-sensitive
connected to an extinguishing agent container tubing bursts and releases the extinguishing
via a pressure release valve. When a fire breaks agent through the direct or indirect line.
out, it results in a drastic increase in temperature. The extinguishing agent is sprayed out of the
container, flooding the microenvironment and
instantly extinguishing the flame.
PAGE 27
28 CEASEFIRE
Ceasefire’s Low Pressure In-Panel Tube-Based While Ceasefire’s Low Pressure In-Panel
System (Direct) is an ideal solution in case of Tube-Based System (Direct) can be designed
fire in a single location, whether small or to suit the specific needs of the premises, it is
large. It uses Ceasefire's UL listed gas also available over the counter in 4
HFC227ea & HFC236fa as an extinguishing pre-fabricated variants - 2 kg, 4 kg, 6 kg and
agent. 9 kg.
Ceasefire’s High Pressure In-Panel Tube-Based Ceasefire’s High Pressure In-Panel Tube-Based
System (Direct) is a perfect solution in case of System (Direct) is designed to suit the
fire in a single location, best suited for areas individual needs of the premises, after careful
ranging from large to very large in size. This inspection and assessment by the Ceasefire
system uses highly pressurised CO2 as the Design Cell, but is also available in 3
extinguishing agent. pre-fabricated variants - 2 kg, 4.5 kg and 6.8 kg.
PAGE 28
THE SMART RANGE 29
Ceasefire’s Low Pressure In-Panel Tube-Based While Ceasefire’s Low Pressure In-Panel
System (Indirect) varies structurally from the Tube-Based System (Indirect) can be designed
Low Pressure In-Panel Tube-Based System to suit the individual needs of a property, it is
(Direct), and is ideal for situations where fire also available over the counter in 4
could break out in multiple locations at the pre-fabricated variants: 2 kg, 4 kg, 6 kg and
same time. It uses Ceasefire's DuPont™ 9 kg.
FE-36™ or HCFC 123 extinguishing agent.
The Ceasefire High Pressure In-Panel This system uses highly pressurised CO2 as the
Tube-Based System (Indirect) varies extinguishing agent. The Ceasefire High
structurally from the High Pressure In-Panel Pressure In-Panel Tube-Based System
Tube-Based System(Direct), and is ideal for (Indirect) is designed to suit the individual
situations where fire could break out in needs of the premises, after careful inspection
multiple locations at the same time, spread and assessment by the Ceasefire Design Cell.
out over a vast area.
PAGE 29
30 CEASEFIRE
KEY FEATURES
Classification: 24-hour Protection:
ABC Works on class A, B, C fires and fires Automatic detection and actuation controls
involving electrically-charged devices. ensure fire protection is always ‘on’.
Effective on a wide range of flammable Flexible Design:
and combustible materials. Flexible tubing allows protection in areas
Self-actuated: that are difficult to access and may not be
Does not require any power supply and able to accommodate any other means of
will function normally in the event of detection.
a power outage. International Quality Standards:
Electronics-Friendly: The Ceasefire Quick Response System – M
Shown to be electrically non-conductive is manufactured to the highest global and
and is safe for electrically charged national standards like LPCB, ISI and CE.
equipment, HFC 236 is kinder on Rugged System:
electronics than the majority of Can withstand even harsh conditions
extinguishing agents available in the where other types of detection systems
market. might be rendered inadequate.
High-value Risk Protection: DLP Tube Based Suppression System:
Suitable for protecting a range of 2 kg and 4 kg come with LPS1666
high-value risks as it virtually eliminates approval and use HFC227ea/HFC236fa UL
damage to high-tech equipment, artwork Listed gas.
and other delicate and sensitive objects.
APPLICATION AREAS:
PAGE 30
THE SMART RANGE 31
PAGE 31