Sei sulla pagina 1di 14

DETAILED DESIGN REPORT

ON
G+3 STORAGE BUILDING- BANGALORE

By
V. ANIL KUMAR

1
CONTENTS

1. Superstructure 3
2. Substructure 9
3. Detailing 12

2
1. Superstructure

Structure Information:
No. of Floors 6(G+3+Terr+OHT)
Total Height 18
Plan Dimensions 52.875m x 42.5m
Typical Floor Height 3m

Architectural Plan

3
Structure Layout Typical floor

Structure Layout Terrace Floor

Materials:
Concrete M30
Steel HYSD500

Sections:
Columns 500x500mm600x600mm,800x800mm,
800mm,800x900mm
Beams 300x700mm,400x800mm

4
Slabs 150mm,200mm,300mm,350mm,450mm
Walls 150mm

Shell Loads:
Load Set Dead Load (kN/m2) Live Load (kN/m2)
Storage 1.5 7.5
Service 1.5 3
Wash 3 2
Terrace 3 1.5
OHT 6 0.75
Stair Case 3 4
Lobby 1.5 4
Kitchen 1.5 3
Dining 1.5 4
Office 1.5 3

Frame Loads:
External Wall 5.06 kN/m2
Internal Wall 3.45 kN/m2
Parapet 1.8 kN/m2

5
Earthquake Load: As per IS 1893:2016 part 1
Zone Factor II
Importance Factor 1.5
Response Reduction Factor 3
Soil Type II (Medium)
Mass Source DL-1, LL-0.25,LL1-0.5
Time Period Tx-0.222s, Ty-0.248s
Base Shear Sx-8200.21 kN, Sy-8200.21 kN

Wind Load: As per IS 875:2015 part 3


Basic Wind Speed 33
Class Type A
Terrain Category III
Probability Factor, k1 1.0
Terrain, height, structure size factor, k2 1.1
Topography factor, k3 1.0
Shear Wx-270.1 kN, Wy-346.229 kN

P-Delta: P-Delta with 1.5DL is considered for Analysis.

6
Property Modifiers:
Section Unfactored Loads (Service) Factored Loads (Strength)
Columns 1.0Ig 0.7Ig
Beams 0.5Ig 0.35Ig
Slabs 0.35Ig 0.25Ig
Walls 1.0Ig 0.7Ig

Stability Checks:
Check Load Case Allowable Observed
Inter Story Drift ( Service) (mm) Spec X 0.003 0.0024 SAFE
Spec Y 0.003 0.0023
Max. Def. against EQ (Service) (mm) Spec X 72 27.88 SAFE
Spec Y 72 27.76
Max. Def. against Wind (mm) Wx 30 0.44 SAFE
Wy 30 0.659
Vertical deflection (mm) DL+LL 20 17.1 SAFE

Modal Analysis:

a) Guideline for Fundamental time period = 0.1 x N =0.1 X 6 = 0.6


Time period = 0.813s

b) No. of modes given should be given in such a way that around 95% to 98% modal
mass participation ratio shall be achieved.
Sum UX=98.42%
Sum UY=96.36%

c) 1st mode of vibration is performed to be translation mode


RZ = 0.86% which is less than 5 %

7
Torsional Irregularity: Torsion Irregularity observed in X-Direction.

Buckling: Buckling is not considered because Slenderness ratio of Building is less than 4

8
2. Substructure Details:
Structure Information:

SBC 100 kN/m2


Nature of Foundation Raft Foundation
Depth of Foundation 1000mm
Size of Foundation 56m x46m
Spring Type Area Spring
Spring Constant 4000 KN/m³
Depth of Water Table 3m

Materials:

Grade of Concrete M30


Grade of Steel HYSD500

9
Checks:

Check Load Case Allowable Observed


Settlement DL+LL 25 mm 22.92 mm SAFE
Soil Pressure DL+LL 100 kN/m2 91.71 kN/m2 SAFE
Punching Shear Service Envlp 1 0.98 SAFE
0.542(SW-1.265m) 0.36 N/mm2
Crack Width Service Envlp 0.2 mm 0.16 mm SAFE
Flotation 0.9DL+1.4WL NO

Reinforcement Cover: As per IS 456:2000

Slabs 25 mm
Beams 40 mm
Columns 40 mm
Walls 40 mm
Foundation Top-50mm, Bottom-60mm

Load Combinations:

For Strength

 1.5DL + 1.5LL
 1.2DL + 1.2LL + SPEC X/Y
 0.9DL + 1.2LL + SPEC X/Y
 0.9DL + 1.5SPEC X/Y
 1.5DL +/- 1.5W X/Y
 1.2DL +1.2LL +/-1.2W X/Y
 1.5DL +/- 1.5W X/Y
 1.2 DL +/- 1.2LL +/- 1.2W X/Y
 0.9 DL +/- 1.5W X/Y

For Service

 1DL + 1LL
 1DL + 1SPEC X/Y
 1DL + 0.8LL + 0.8SPEC X/Y

List of Codes used:

Code Details
IS-456 2000 For RCC Design
IS-1893 Part-1, 2016 For Earthquake Loads
IS-875 Part-1, 1987 For Dead Loads
IS-875 Part-2, 1987 For Live Loads

10
IS-875 Part-3, 2015 For Wind Loads
IS-13920 2016 For Ductile Detailing

Softwares used:

Superstructure ETABS 2016


Substructure SAFE 2016

11
3. Detailing:

Column 21

12
Column 44

13
Shear Wall PW1

14

Potrebbero piacerti anche