Sei sulla pagina 1di 110

Peruding Azman, Ooi & Rao Sdn Bhd 11.

4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN


PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Cantilever wall analysis


Input data
Project
Task : 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
Part : OUTLET STRUCTURE BUTTRESS RC WALL
Customer : JPS WILAYAH PERSEKUTUAN
Author : PERUNDING AZMAN, OOI & RAO / DR. ESAM
Date : 12/19/2019
Project ID : PULAPOL UNDERGROUNG STORAGE RC TANK
Settings
(input for current task)
Materials and standards
Concrete structures : EN 1992-1-1 (EC2)
Coefficients EN 1992-1-1 : standard
Wall analysis
Active earth pressure calculation : Coulomb
Passive earth pressure calculation : Coulomb
Earthquake analysis : Mononobe-Okabe
Shape of earth wedge : Consider always vertical
Base key : The base key is considered as front face resistance
Allowable eccentricity : 0.333
Verification methodology : according to EN 1997
Design approach : 2 - reduction of actions and resistances
Partial factors on actions (A)
Permanent design situation
Unfavourable Favourable
Permanent actions : G = 1.35 [–] 1.00 [–]
Variable actions : Q = 1.50 [–] 0.00 [–]
Water load : w = 1.35 [–]

Partial factors for resistances (R)


Permanent design situation
Partial factor on overturning : Rv = 1.40 [–]
Partial factor on sliding resistance : Rh = 1.10 [–]
Partial factor on bearing capacity : Re = 1.40 [–]

Partial factors for variable actions


Permanent design situation
Factor for combination value : 0 = 0.70 [–]
Factor for frequent value : 1 = 0.50 [–]
Factor for quasi-permanent value : 2 = 0.30 [–]
Material of structure
Unit weight  = 24.00 kN/m3
Analysis of concrete structures carried out according to the standard EN 1992-1-1 (EC2).

Concrete : C 35/45
Cylinder compressive strength fck = 35.00 MPa
Tensile strength fctm = 3.20 MPa
Longitudinal steel : S 500

1
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Yield strength fyk = 500.00 MPa


Geometry of structure
Coordinate Depth
No.
X [m] Z [m]
1 0.00 0.00
2 1.73 10.40
3 2.23 10.40
4 2.23 11.40
5 -5.50 11.40
6 -5.50 10.40
7 -0.60 10.40
8 -0.60 0.00
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 22.99 m2.

Counterfort
Type : buttress
Spacing l = 4.00 m
Thickness b = 0.60 m
Upper width a1 = 0.50 m
`

2
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name : Butress Wall 3D Model Stage - analysis : 1 - 0


Description : Butress Wall 3D Model

3
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Basic soil parameters - (effective stress-state)


ef cef  su 
No. Name Pattern
[°] [kPa] [kN/m3] [kN/m3] [°]

1 Earth Fill 25.00 15.00 18.00 10.00 17.00

4 Existing 30.00 15.00 18.00 9.00 20.00

Basic soil parameters - (total stress-state)


cu a 
No. Name Pattern
[kPa] [kPa] [kN/m3]

2 LIMESTONE 100.00 50.00 24.00

3 Concrete 500.00 1.00 24.00

Soil parameters to compute pressure at rest


Type ef  OCR Kr
No. Name Pattern
calculation [°] [–] [–] [–]

1 Earth Fill cohesionless 25.00 - - -

2 LIMESTONE cohesive - 0.33 - -

3 Concrete cohesive - 0.20 - -

4 Existing cohesive - 0.35 - -

Soil parameters
Earth Fill
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 25.00 °
Cohesion of soil : cef = 15.00 kPa
Angle of friction struc.-soil :  = 17.00 °
Soil : cohesionless
Saturated unit weight : sat = 20.00 kN/m3

LIMESTONE
Unit weight :  = 24.00 kN/m3
Stress-state : total
Cohesion of soil : cu = 100.00 kPa
Adhesion struc.-soil : a = 50.00 kPa
Soil : cohesive
Poisson's ratio :  = 0.33

Concrete
Unit weight :  = 24.00 kN/m3
Stress-state : total
Cohesion of soil : cu = 500.00 kPa
Adhesion struc.-soil : a = 1.00 kPa
Soil : cohesive

4
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Poisson's ratio :  = 0.20

Existing
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 30.00 °
Cohesion of soil : cef = 15.00 kPa
Angle of friction struc.-soil :  = 20.00 °
Soil : cohesive
Poisson's ratio :  = 0.35
Saturated unit weight : sat = 19.00 kN/m3

Backfill
Assigned soil : Earth Fill
Slope = 50.00 °

Geological profile and assigned soils


Position information
Terrain elevation = 40.00 m
Geological profile and assigned soils
Thickness of layer Depth Altitude
No. Assigned soil Pattern
t [m] z [m] [m]

1 6.00 0.00 .. 6.00 40.00 .. 34.00 Existing

2 - 6.00 ..  34.00 .. - LIMESTONE

Foundation
Type of foundation : input parameters of contact base-soil
Parameters
Friction coefficient base-soil  = 0.50
Cohesion base-soil a = 100.00 kPa
Terrain profile
Terrain behind the structure is flat.

Water influence
GWT behind the structure lies at a depth of 10.40 m
GWT in front of the structure lies at a depth of 10.40 m
Subgrade at the heel is permeable.
Hydraulic gradient = 0.00
The evolution of tensile cracks is considered in the analyses. Depth of cracks is 0.10 m.

5
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name : Geometry Stage - analysis : 1 - 0


Description : Geometry

10.00 (30.00)

12.00 (28.00)

13.00 (27.00)
0.00 (40.00)

2.00 (38.00)

4.00 (36.00)

6.00 (34.00)

8.00 (32.00)
10.40
16.00

6.00 14.00

12.00

10.00
1

8.00
2

+z
6.00

4.00
10.40]

11.40]
[2.23;

[2.23;
10.40]
[1.73;
10
11
12
6 97
8
0.50

2.00
6.00:1
[0.00;
0.00]

i = 0.00
0.50[-0.60;

[-0.60;
10.40]
0.00]

0.00
16 5
1
2
3
4
0.60

15

7.73

-2.00
4.90

-4.00
1.00 [-5.50;

[-5.50;
10.40]

11.40]
14

13

-6.00
10.40
11.40

-8.00

-10.00
40.00

-12.00
1.00

-13.00
10.40

6
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Resistance on front face of the structure


Resistance on front face of the structure: passive
Soil on front face of the structure - Earth Fill
Angle of friction struc.-soil  = 46.00 °
Soil thickness in front of structure h = 1.00 m
Terrain in front of structure is flat.

Settings of the stage of construction


Design situation : permanent
The wall is free to move. Active earth pressure is therefore assumed.

Verification No. 1 (Stage of construction 1)


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00

7
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] overtur. sliding stress
Weight - wall 0.00 -4.11 474.35 5.30 1.000 1.000 1.350
FF resistance -56.26 -0.46 -58.26 0.00 1.000 1.000 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000 1.000 1.350
Active pressure 235.60 -2.98 101.73 7.73 1.350 1.350 1.350
Water pressure 0.00 -11.40 0.00 7.73 1.000 1.000 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350 1.350 1.350
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 3824.57 kNm/m
Overturning moment Movr = 923.49 kNm/m
Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 1070.88 kN/m
Active horizontal force Hact = 261.87 kN/m
Wall for slip is SATISFACTORY

Overall check - WALL is SATISFACTORY

Maximum stress in footing bottom : 135.06 kPa

8
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name : Verification Stage - analysis : 1 - 1


Description : 11.19m HEIGHT RC WALL

10.00 (30.00)

12.00 (28.00)

13.00 (27.00)
0.00 (40.00)

2.00 (38.00)

4.00 (36.00)

6.00 (34.00)

8.00 (32.00)
10.40
16.00

6.00 14.00

12.00

10.00
1

8.00
2

+z
6.00
256.62

4.00
0.05

0.50

2.00
6.00:1
255.84

474.35

0.00
0.60

0.50

7.73

-2.00
+x
4.90

-4.00
+z
80.99

-6.00
10.40

1.00
11.40

-8.00

-10.00
40.00

-12.00
1.00

-13.00
10.40

9
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Bearing capacity of foundation soil (Stage of construction 1)


Design load acting at the center of footing bottom
Moment Norm. force Shear Force Eccentricity Stress
No.
[kNm/m] [kN/m] [kN/m] [–] [kPa]
1 -1903.78 1044.43 242.17 0.000 135.06
2 -1301.77 809.26 261.87 0.000 104.65
Service load acting at the center of footing bottom
Moment Norm. force Shear Force
No.
[kNm/m] [kN/m] [kN/m]
1 -1410.21 773.65 179.39
Dimensioning No. 1 (Stage of construction 1)
Wall stem check - front vertical reinf.
Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00

10
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Wall stem check - front vertical reinf. - MEd
Wall check at the construction joint 5.20 m from the wall crest
Hi = 52.39 kPa
MEd = 0.03 * Hi * H1 * l / 4 * b = 0.03 * 52.39 * 10.40 * 4.00 / 4 * 1.00 = 16.34 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.57 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 0.86 m = xmax
Ultimate moment MRd = 4716.61 kNm > 16.34 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - front vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 41.34 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079

11
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000

12
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Wall stem check - back vertical reinf. - MEd
Wall check at the construction joint 10.40 m from the wall crest
Hi = 52.39 kPa
MEd = 0.03 * Hi * H1 * l * b = 0.03 * 52.39 * 10.40 * 4.00 * 1.00 = 65.35 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 2.33 m
Reinforcement ratio  = 0.35 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 1.40 m = xmax
Ultimate moment MRd = 7746.39 kNm > 65.35 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 41.34 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - front horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360

13
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure distribution behind the structure (without surcharge)


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Wall stem check - front horizontal reinf.
pi = 20.67 kPa
MEd = 1 / 20 * pi * l2 = 1 / 20 * 20.67 * 4.002 = 171.98 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.17 % > 0.17 % = min
Position of neutral axis x = 0.06 m < 0.87 m = xmax
Ultimate shear force VRd = 4887.88 kN > 429.96 kN = VEd
Ultimate moment MRd = 15328.55 kNm > 171.98 kNm = MEd
Cross-section is SATISFACTORY.

14
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Wall stem check - back horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00

15
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Forces acting on construction


Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Wall stem check - back horizontal reinf.
pi = 20.67 kPa
MEd = 1 / 12 * pi * l2 = 1 / 12 * 20.67 * 4.002 = 286.64 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.17 % > 0.17 % = min
Position of neutral axis x = 0.06 m < 0.87 m = xmax
Ultimate shear force VRd = 4887.88 kN > 429.96 kN = VEd
Ultimate moment MRd = 15328.55 kNm > 286.64 kNm = MEd
Cross-section is SATISFACTORY.

Wall jump check - bottom reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00

16
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Layer Start [m] Z W Pressure Hor. comp. Vert. comp.


No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -56.26 -0.46 -58.26 0.00 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.350
Active pressure 235.60 -2.98 101.73 7.73 1.350
Water pressure 0.00 -11.40 0.00 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Wall jump check - bottom reinf.
j1 = 135.06 kPa
MEd = 1 / 12 * j1 * l2 = 1 / 12 * 135.06 * 4.002 = 882.37 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate shear force VRd = 1676.48 kN > 1323.55 kN = VEd
Ultimate moment MRd = 3212.47 kNm > 882.37 kNm = MEd
Cross-section is SATISFACTORY.

17
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Wall jump check - top reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00

18
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Forces acting on construction


Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -56.26 -0.46 -58.26 0.00 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.350
Active pressure 235.60 -2.98 101.73 7.73 1.350
Water pressure 0.00 -11.40 0.00 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Wall jump check - top reinf.
j1 = 135.06 kPa
MEd = 1 / 20 * j1 * l2 = 1 / 20 * 135.06 * 4.002 = 529.42 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate shear force VRd = 1676.48 kN > 1323.55 kN = VEd
Ultimate moment MRd = 3212.47 kNm > 529.42 kNm = MEd
Cross-section is SATISFACTORY.

Buttress check
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.95 9.46 25.00 15.00 18.00 17.00 0.435
2 4.05 9.46 25.00 15.00 18.00 17.00 0.435
3 4.40 9.46 25.00 15.00 18.00 17.00 0.435
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
1.95 35.10 0.00 0.00 0.00 0.00
1.95 35.10 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 31.68 28.36 14.12
6.00 108.00 0.00 31.68 28.36 14.12
3
10.40 187.18 0.00 66.09 59.17 29.45
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 1.95 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00

19
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Pressure profile due to surcharge - Tensile crack


Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] moment norm.force shear for.
Weight - wall 0.00 -4.18 366.01 0.82 1.350 1.350 1.000
Active pressure 249.95 -2.82 124.41 1.86 1.350 1.350 1.350
Water pressure 0.00 -10.40 0.00 0.60 1.000 1.000 1.000
Tensile crack 0.05 -10.33 0.00 0.60 1.350 1.000 1.350
Buttress check
Wall check at the construction joint 10.40 m from the wall crest
Shear reinf. - 2 profile 16.0 mm; distance 200.0 mm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 0.60 m
Cross-section height = 7.23 m
Reinforcement ratio  = 0.19 % > 0.17 % = min
Position of neutral axis x = 0.31 m < 4.42 m = xmax
Ultimate shear force VRd = 14096.07 kN > 1552.49 kN = VEd
Ultimate moment MRd = 24623.00 kNm > 4626.65 kNm = MEd
Cross-section is SATISFACTORY.

20
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Name : Dimensioning

Bending moment Shear force


Max MRd = 24623.00 kNm Max VRd = 14096.07 kN
52 prof. 25.0mm,cover 50.0mm MEd = 4626.65 kNm VEd = 1552.49 kN
40.0052 prof. 25.0mm,cover 50.0mm 0.60
0.05 0.01
3181.47 0.00
2035.21
0.00 (40.00)
Peruding Azman, Ooi & Rao Sdn Bhd

0.50
PERUNDING AZMAN, OOI & RAO / DR.

Description : 11.19m HEIGHT RC WALL

2.00 (38.00)
6.00
10 prof. 32.0mm,cover 50.0mm 366.01 10 prof. 32.0mm,cover 50.0mm
1
10 prof. 32.0mm,cover 50.0mm 4.00 (36.00)
6.00:1

+z
10.40 10.40 10.40
11.40
279.20 6.00 (34.00)

8.00 (32.00)
10 prof. 32.0mm,cover 50.0mm 4.90 0.50
2
4626.65
10.00 24623.00
(30.00) 1552.49 14096.07
1.00 1.00 +x
0 40000.00
0 15000.00
10 prof. 32.0mm,cover 50.0mm 12.00 (28.00)
[kNm] [kN]
7.73 13.00 (27.00)
+z

0.00
2.00
4.00
6.00
8.00

-8.00
-6.00
-4.00
-2.00
10.00
12.00
14.00
16.00

-13.00
-12.00
-10.00

[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Stage - analysis : 1 - 1
OUTLET STRUCTURE BUTTRESS RC WALL
11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN

21
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Slope stability analysis


Input data
Project
Settings
(input for current task)
Stability analysis
Earthquake analysis : Standard
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor : SFs = 1.50 [–]
Interface
Coordinates of interface points [m]
No. Interface location
x z x z x z
1 -28.50 29.60 -5.50 29.60 -0.60 29.60
-0.60 40.00 0.00 40.00 11.80 40.00
34.20 40.00

2 0.00 40.00 1.73 29.60 2.23 29.60

3 -5.50 28.60 2.23 28.60 2.23 29.60


3.07 29.60 6.76 34.00 11.80 40.00

4 6.76 34.00 34.20 34.00

5 -28.50 28.60 -5.50 28.60 -5.50 29.60

6 2.23 28.60 3.07 29.60

Soil parameters - effective stress state


ef cef 
No. Name Pattern
[°] [kPa] [kN/m3]

1 Earth Fill 25.00 15.00 18.00

22
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

ef cef 
No. Name Pattern
[°] [kPa] [kN/m3]

2 Existing 30.00 15.00 18.00

Soil parameters - uplift


sat s n
No. Name Pattern
[kN/m3] [kN/m3] [–]

1 Earth Fill 20.00

2 Existing 19.00

Soil parameters - total stress state


cu 
No. Name Pattern
[kPa] [kN/m3]

1 LIMESTONE 100.00 24.00

2 Concrete 500.00 24.00

Soil parameters
Earth Fill
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 25.00 °
Cohesion of soil : cef = 15.00 kPa
Saturated unit weight : sat = 20.00 kN/m3

LIMESTONE
Unit weight :  = 24.00 kN/m3
Stress-state : total
Cohesion of soil : cu = 100.00 kPa

Concrete
Unit weight :  = 24.00 kN/m3
Stress-state : total
Cohesion of soil : cu = 500.00 kPa

Existing
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 30.00 °
Cohesion of soil : cef = 15.00 kPa
Saturated unit weight : sat = 19.00 kN/m3

23
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Rigid bodies

No. Name Sample
[kN/m3]

1 Wall material 24.00

Assigning and surfaces


Coordinates of surface points [m] Assigned
No. Surface position
x z x z soil
1 34.20 34.00 34.20 40.00
Existing
11.80 40.00 6.76 34.00

2 3.07 29.60 6.76 34.00


Earth Fill
11.80 40.00 0.00 40.00
1.73 29.60 2.23 29.60

3 -5.50 28.60 2.23 28.60


Wall material
2.23 29.60 1.73 29.60
0.00 40.00 -0.60 40.00
-0.60 29.60 -5.50 29.60

4 -5.50 28.60 -5.50 29.60


Earth Fill
-28.50 29.60 -28.50 28.60

5 3.07 29.60 2.23 29.60


Earth Fill
2.23 28.60

6 2.23 28.60 -5.50 28.60


LIMESTONE
-28.50 28.60 -28.50 23.60
34.20 23.60 34.20 34.00
6.76 34.00 3.07 29.60

Water
Water type : GWT
Coordinates of GWT points [m]
No. GWT location
x z x z x z
-28.50 29.60 1.73 29.60 34.20 29.60

24
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Tensile crack
Tensile crack not input.
Earthquake
Earthquake not included.
Settings of the stage of construction
Design situation : permanent
Results (Stage of construction 1)
Analysis 1
Circular slip surface
Slip surface parameters
x= -1.37 [m] 1 = -27.77 [°]
Center : Angles :
z= 42.05 [m] 2 = 81.62 [°]
Radius : R= 14.07 [m]
The slip surface after optimization.
Slope stability verification (Bishop)
Sum of active forces : Fa = 956.28 kN/m
Sum of passive forces : Fp = 2000.83 kN/m
Sliding moment : Ma = 13454.80 kNm/m
Resisting moment : Mp = 28151.61 kNm/m
Factor of safety = 2.09 > 1.50
Slope stability ACCEPTABLE
Optimization of circular slip surface (Bishop)
Center Radius
No. FS Verification
x [m] z [m] R [m]
1 0.56 45.99 33.06 2.47 ACCEPTABLE
2 0.56 45.99 33.06 2.47 ACCEPTABLE
3 0.56 45.99 33.06 2.47 ACCEPTABLE
4 -5.32 83.76 58.83 3.24 ACCEPTABLE
5 3.97 59.59 35.85 2.68 ACCEPTABLE
6 1.34 43.86 32.89 2.52 ACCEPTABLE
7 1.53 42.68 32.58 2.55 ACCEPTABLE
8 -1.66 49.18 24.09 2.41 ACCEPTABLE
9 -6.01 84.63 59.32 3.29 ACCEPTABLE
10 -2.88 66.24 44.51 2.71 ACCEPTABLE
11 10.80 49.18 24.09 24.61 ACCEPTABLE
12 0.56 45.99 33.06 2.47 ACCEPTABLE
13 -38.87 80.05 61.77 45.22 ACCEPTABLE
14 -14.12 49.18 24.09 55.45 ACCEPTABLE
15 12.10 44.63 21.48 21.04 ACCEPTABLE
16 -72.46 485.29 457.84 45.85 ACCEPTABLE
17 -1.66 49.18 24.09 2.41 ACCEPTABLE
18 -65.58 381.02 353.87 43.46 ACCEPTABLE
19 -37.79 204.31 177.33 31.28 ACCEPTABLE
20 -4.80 71.75 46.31 2.99 ACCEPTABLE
21 -2.64 60.77 37.78 2.63 ACCEPTABLE
22 6.65 49.18 24.09 2.81 ACCEPTABLE
23 0.15 46.55 29.51 2.43 ACCEPTABLE
24 -17.82 76.58 47.39 42.06 ACCEPTABLE
25 -28.49 93.40 67.20 41.15 ACCEPTABLE
26 -9.97 49.18 24.09 3.25 ACCEPTABLE
27 -8.29 43.32 20.86 2.90 ACCEPTABLE

25
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
28 -4.26 68.99 44.06 2.90 ACCEPTABLE
29 6.66 49.14 24.06 2.82 ACCEPTABLE
30 -415.89 1149.92 1189.65 71.10 ACCEPTABLE
31 -407.58 1149.92 1189.65 37.63 ACCEPTABLE
32 -1.66 49.18 24.09 2.41 ACCEPTABLE
33 4.61 46.64 22.54 2.55 ACCEPTABLE
34 -2.30 46.35 18.50 2.23 ACCEPTABLE
35 5.25 41.47 15.43 21.13 ACCEPTABLE
36 -62.14 260.33 235.36 45.49 ACCEPTABLE
37 -40.47 152.37 127.90 31.64 ACCEPTABLE
38 -6.18 64.95 36.61 44.37 ACCEPTABLE
39 -2.71 52.86 26.64 2.49 ACCEPTABLE
40 3.24 46.35 18.50 31.13 ACCEPTABLE
41 -0.14 43.89 21.12 2.36 ACCEPTABLE
42 -13.47 60.01 30.49 43.51 ACCEPTABLE
43 -33.16 83.28 60.79 42.61 ACCEPTABLE
44 -7.84 46.35 18.50 63.01 ACCEPTABLE
45 -5.84 41.51 15.45 2.73 ACCEPTABLE
46 -4.70 59.82 32.15 2.71 ACCEPTABLE
47 2.11 49.08 20.61 49.91 ACCEPTABLE
48 -2.30 46.35 18.50 2.23 ACCEPTABLE
49 0.40 48.75 20.35 33.98 ACCEPTABLE
50 -2.78 43.79 14.66 93.60 ACCEPTABLE
51 -14.85 89.07 59.48 33.55 ACCEPTABLE
52 -7.87 68.81 39.24 29.79 ACCEPTABLE
53 -4.95 58.03 29.79 29.70 ACCEPTABLE
54 -2.62 50.74 23.94 2.42 ACCEPTABLE
55 1.39 46.35 18.50 20.07 ACCEPTABLE
56 -0.60 44.41 19.87 2.32 ACCEPTABLE
57 -1.24 41.15 12.67 54.82 ACCEPTABLE
58 -9.44 54.72 25.50 34.30 ACCEPTABLE
59 -8.57 53.72 24.21 34.55 ACCEPTABLE
60 -5.99 46.35 18.50 35.33 ACCEPTABLE
61 -4.71 43.24 16.42 2.50 ACCEPTABLE
62 -0.61 40.07 11.99 20.27 ACCEPTABLE
63 -3.91 54.79 27.08 2.53 ACCEPTABLE
64 0.47 48.59 20.21 34.06 ACCEPTABLE
65 -344.64 749.83 794.11 57.20 ACCEPTABLE
66 -340.95 749.83 794.11 40.21 ACCEPTABLE
67 -2.30 46.35 18.50 2.23 ACCEPTABLE
68 -0.92 48.98 20.53 33.89 ACCEPTABLE
69 -2.99 45.45 16.53 87.56 ACCEPTABLE
70 -8.22 65.76 36.43 29.73 ACCEPTABLE
71 -4.21 56.95 27.57 85.32 ACCEPTABLE
72 -4.10 53.81 25.66 17.13 ACCEPTABLE
73 2.19 41.42 15.41 2.36 ACCEPTABLE
74 -2.54 49.31 22.13 2.38 ACCEPTABLE
75 0.16 46.35 18.50 7.23 ACCEPTABLE
76 -1.01 44.88 19.18 2.30 ACCEPTABLE
77 -1.79 43.10 14.73 33.91 ACCEPTABLE
78 -6.98 51.72 22.83 31.14 ACCEPTABLE
79 -5.17 49.70 20.26 31.99 ACCEPTABLE
80 -4.76 46.35 18.50 23.38 ACCEPTABLE

26
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
81 -3.01 42.10 15.76 2.34 ACCEPTABLE
82 -0.38 40.34 12.99 2.17 ACCEPTABLE
83 1.87 40.74 13.21 26.56 ACCEPTABLE
84 -4.78 52.36 23.38 85.04 ACCEPTABLE
85 -1.01 46.37 17.29 88.09 ACCEPTABLE
86 -1.89 45.34 17.77 2.24 ACCEPTABLE
87 -0.80 42.71 16.10 2.24 ACCEPTABLE
88 2.08 40.34 12.99 25.66 ACCEPTABLE
89 -4.41 43.40 14.94 55.78 ACCEPTABLE
90 -2.19 41.67 12.45 96.75 ACCEPTABLE
91 -2.84 40.34 12.99 2.28 ACCEPTABLE
92 -1.44 44.26 17.05 2.23 ACCEPTABLE
93 1.74 41.01 13.37 27.29 ACCEPTABLE
94 -356.50 817.98 861.10 53.69 ACCEPTABLE
95 -407.06 1128.47 1168.35 44.13 ACCEPTABLE
96 -354.04 817.98 861.10 43.64 ACCEPTABLE
97 -0.38 40.34 12.99 2.17 ACCEPTABLE
98 0.89 41.06 13.40 20.56 ACCEPTABLE
99 -2.99 47.15 18.66 45.63 ACCEPTABLE
100 -0.55 43.88 15.30 76.81 ACCEPTABLE
101 -1.41 43.56 16.05 2.19 ACCEPTABLE
102 -0.69 41.95 15.07 2.22 ACCEPTABLE
103 1.26 40.34 12.99 18.10 ACCEPTABLE
104 -3.11 42.46 14.29 25.34 ACCEPTABLE
105 -1.39 41.10 12.40 99.12 ACCEPTABLE
106 -2.02 40.34 12.99 2.21 ACCEPTABLE
107 -1.10 42.86 15.61 2.21 ACCEPTABLE
108 0.99 40.87 13.28 18.94 ACCEPTABLE
109 -345.94 771.29 815.18 43.13 ACCEPTABLE
110 -0.38 40.34 12.99 2.17 ACCEPTABLE
111 0.39 40.97 13.35 13.32 ACCEPTABLE
112 -0.61 40.14 12.12 17.42 ACCEPTABLE
113 -2.02 44.47 16.34 6.45 ACCEPTABLE
114 -0.41 42.54 14.34 21.92 ACCEPTABLE
115 -1.07 42.44 14.97 2.17 ACCEPTABLE
116 -0.61 41.43 14.38 2.20 ACCEPTABLE
117 0.71 40.34 12.99 10.33 ACCEPTABLE
118 0.05 40.00 13.65 2.26 ACCEPTABLE
119 -2.22 41.79 13.84 5.28 ACCEPTABLE
120 -0.99 40.80 12.52 28.21 ACCEPTABLE
121 -1.47 40.34 12.99 2.18 ACCEPTABLE
122 -0.86 41.98 14.70 2.18 ACCEPTABLE
123 0.52 40.72 13.20 12.13 ACCEPTABLE
124 -320.88 630.69 677.79 50.00 ACCEPTABLE
125 -319.79 630.69 677.79 44.47 ACCEPTABLE
126 -0.38 40.34 12.99 2.17 ACCEPTABLE
127 0.10 40.82 13.26 8.44 ACCEPTABLE
128 -0.55 40.24 12.43 9.64 ACCEPTABLE
129 -1.43 42.94 15.06 2.12 ACCEPTABLE
130 -1.09 43.75 15.61 10.53 ACCEPTABLE
131 -1.66 42.84 14.55 22.94 ACCEPTABLE
132 -2.65 46.21 17.83 27.17 ACCEPTABLE
133 -1.57 44.76 16.35 32.68 ACCEPTABLE

27
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
134 -1.97 44.68 16.70 2.16 ACCEPTABLE
135 -0.12 41.72 14.29 2.16 ACCEPTABLE
136 -1.54 43.72 16.04 2.17 ACCEPTABLE
137 -0.70 42.94 15.06 4.48 ACCEPTABLE
138 -1.02 42.57 15.30 2.19 ACCEPTABLE
139 -1.29 42.13 14.07 6.76 ACCEPTABLE
140 -2.73 44.14 15.89 21.60 ACCEPTABLE
141 -1.95 43.41 14.96 45.05 ACCEPTABLE
142 -2.16 42.94 15.06 2.15 ACCEPTABLE
143 -0.83 40.71 13.46 2.18 ACCEPTABLE
144 -0.38 40.34 12.99 2.17 ACCEPTABLE
145 -1.71 41.99 14.45 2.18 ACCEPTABLE
146 -0.88 41.32 13.56 2.11 ACCEPTABLE
147 -0.48 41.97 13.97 14.96 ACCEPTABLE
148 -1.08 41.21 13.02 18.08 ACCEPTABLE
149 -2.03 44.20 15.94 16.08 ACCEPTABLE
150 -0.96 42.90 14.60 23.83 ACCEPTABLE
151 -1.39 42.86 15.01 2.13 ACCEPTABLE
152 0.41 40.22 12.93 5.63 ACCEPTABLE
153 -1.01 42.06 14.50 2.16 ACCEPTABLE
154 -0.15 41.32 13.56 10.67 ACCEPTABLE
155 -0.52 41.02 13.90 2.19 ACCEPTABLE
156 -0.71 40.55 12.61 12.51 ACCEPTABLE
157 -2.15 42.38 14.24 11.39 ACCEPTABLE
158 -1.34 41.69 13.34 34.32 ACCEPTABLE
159 -1.61 41.32 13.56 2.14 ACCEPTABLE
160 -1.20 40.52 13.09 2.17 ACCEPTABLE
161 -1.41 40.93 13.33 2.16 ACCEPTABLE
162 -0.54 40.24 12.43 9.65 ACCEPTABLE
163 -1.21 42.48 14.76 2.14 ACCEPTABLE
164 -0.33 41.67 13.77 12.77 ACCEPTABLE
165 -337.32 722.35 767.17 44.99 ACCEPTABLE
166 -0.88 41.32 13.56 2.11 ACCEPTABLE
167 -0.63 41.77 13.84 9.12 ACCEPTABLE
168 -1.02 41.26 13.21 11.08 ACCEPTABLE
169 -1.63 43.17 15.07 4.45 ACCEPTABLE
170 -0.92 42.34 14.21 13.00 ACCEPTABLE
171 -1.22 42.34 14.51 2.12 ACCEPTABLE
172 -0.02 40.59 13.14 3.43 ACCEPTABLE
173 -0.97 41.81 14.19 2.15 ACCEPTABLE
174 -0.39 41.32 13.56 6.94 ACCEPTABLE
175 -0.63 41.12 13.77 2.17 ACCEPTABLE
176 -0.77 40.81 12.93 8.73 ACCEPTABLE
177 -1.73 42.03 14.01 2.10 ACCEPTABLE
178 -1.52 42.57 14.37 14.24 ACCEPTABLE
179 -1.88 41.97 13.67 27.02 ACCEPTABLE
180 -2.53 44.02 15.67 27.47 ACCEPTABLE
181 -1.81 43.14 14.77 32.08 ACCEPTABLE
182 -2.10 43.13 15.05 8.02 ACCEPTABLE
183 -0.85 41.26 13.53 2.12 ACCEPTABLE
184 -1.80 42.52 14.64 2.13 ACCEPTABLE
185 -1.24 42.03 14.01 5.59 ACCEPTABLE
186 -1.44 41.79 14.18 2.16 ACCEPTABLE

28
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
187 -1.64 41.52 13.38 12.94 ACCEPTABLE
188 -2.60 42.78 14.51 22.51 ACCEPTABLE
189 -2.07 42.31 13.91 40.09 ACCEPTABLE
190 -2.22 42.03 14.01 7.32 ACCEPTABLE
191 -1.30 40.57 12.96 2.14 ACCEPTABLE
192 -1.00 40.33 12.65 2.13 ACCEPTABLE
193 -1.91 41.43 13.63 2.14 ACCEPTABLE
194 -1.36 40.99 13.04 3.26 ACCEPTABLE
195 -1.59 40.80 13.26 2.16 ACCEPTABLE
196 -2.07 41.74 13.82 2.13 ACCEPTABLE
197 -1.50 41.26 13.21 5.58 ACCEPTABLE
198 -1.95 42.84 14.85 2.13 ACCEPTABLE
199 -1.39 42.31 14.19 7.42 ACCEPTABLE
200 -326.45 661.47 707.71 47.51 ACCEPTABLE
201 -335.29 710.85 755.92 46.81 ACCEPTABLE
202 -325.97 661.47 707.71 46.77 ACCEPTABLE
203 -1.73 42.03 14.01 2.10 ACCEPTABLE
204 -1.59 42.40 14.25 10.14 ACCEPTABLE
205 -1.83 42.00 13.79 18.15 ACCEPTABLE
206 -2.25 43.32 15.08 14.99 ACCEPTABLE
207 -1.78 42.76 14.50 20.45 ACCEPTABLE
208 -1.98 42.76 14.69 6.78 ACCEPTABLE
209 -1.14 41.52 13.69 2.12 ACCEPTABLE
210 -1.78 42.36 14.43 2.13 ACCEPTABLE
211 -1.41 42.03 14.01 4.45 ACCEPTABLE
212 -1.53 41.87 14.11 2.14 ACCEPTABLE
213 -1.67 41.69 13.59 7.81 ACCEPTABLE
214 -2.31 42.53 14.34 16.00 ACCEPTABLE
215 -1.95 42.21 13.93 24.27 ACCEPTABLE
216 -2.05 42.03 14.01 5.26 ACCEPTABLE
217 -1.43 41.03 13.28 2.14 ACCEPTABLE
218 -1.24 40.87 13.07 2.12 ACCEPTABLE
219 -1.85 41.64 13.76 2.13 ACCEPTABLE
220 -1.48 41.33 13.35 2.10 ACCEPTABLE
221 -1.33 41.67 13.56 10.27 ACCEPTABLE
222 -1.58 41.30 13.12 16.82 ACCEPTABLE
223 -1.99 42.55 14.35 16.03 ACCEPTABLE
224 -1.52 42.01 13.79 17.98 ACCEPTABLE
225 -1.72 42.02 14.00 3.27 ACCEPTABLE
226 -0.90 40.84 13.05 3.25 ACCEPTABLE
227 -1.53 41.65 13.76 2.12 ACCEPTABLE
228 -1.16 41.33 13.35 5.55 ACCEPTABLE
229 -1.29 41.18 13.47 2.14 ACCEPTABLE
230 -1.42 41.00 12.94 7.88 ACCEPTABLE
231 -2.06 41.81 13.66 12.39 ACCEPTABLE
232 -1.69 41.49 13.25 23.57 ACCEPTABLE
233 -1.80 41.33 13.35 2.11 ACCEPTABLE
234 -1.19 40.39 12.68 2.13 ACCEPTABLE
235 -1.00 40.23 12.48 2.12 ACCEPTABLE
236 -1.61 40.96 13.13 2.13 ACCEPTABLE
237 -1.23 40.67 12.73 5.24 ACCEPTABLE
238 -1.39 40.54 12.88 2.15 ACCEPTABLE
239 -1.71 41.15 13.24 2.12 ACCEPTABLE

29
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
240 -1.33 40.84 12.84 6.71 ACCEPTABLE
241 -1.63 41.84 13.88 2.11 ACCEPTABLE
242 -1.25 41.50 13.46 6.72 ACCEPTABLE
243 -328.48 670.02 716.05 50.12 ACCEPTABLE
244 -334.38 702.96 748.21 48.31 ACCEPTABLE
245 -328.16 670.02 716.05 48.96 ACCEPTABLE
246 -1.48 41.33 13.35 2.10 ACCEPTABLE
247 -1.38 41.56 13.49 7.37 ACCEPTABLE
248 -1.55 41.31 13.20 11.21 ACCEPTABLE
249 -1.82 42.13 14.00 10.14 ACCEPTABLE
250 -1.50 41.78 13.64 10.13 ACCEPTABLE
251 -1.64 41.79 13.78 2.10 ACCEPTABLE
252 -1.55 42.03 13.94 5.61 ACCEPTABLE
253 -1.71 41.77 13.63 10.92 ACCEPTABLE
254 -1.98 42.62 14.46 10.21 ACCEPTABLE
255 -1.67 42.26 14.09 13.55 ACCEPTABLE
256 -1.80 42.26 14.22 3.27 ACCEPTABLE
257 -1.25 41.46 13.57 2.10 ACCEPTABLE
258 -1.67 42.01 14.06 2.12 ACCEPTABLE
259 -1.42 41.79 13.78 4.44 ACCEPTABLE
260 -1.51 41.68 13.85 2.13 ACCEPTABLE
261 -1.60 41.57 13.50 6.69 ACCEPTABLE
262 -2.03 42.12 14.00 10.16 ACCEPTABLE
263 -1.78 41.91 13.72 16.44 ACCEPTABLE
264 -1.86 41.79 13.78 4.41 ACCEPTABLE
265 -1.44 41.12 13.29 2.13 ACCEPTABLE
266 -1.31 41.02 13.16 2.12 ACCEPTABLE
267 -1.72 41.54 13.62 2.12 ACCEPTABLE
268 -1.47 41.33 13.35 2.10 ACCEPTABLE
269 -1.57 41.23 13.43 2.13 ACCEPTABLE
270 -1.79 41.66 13.70 2.11 ACCEPTABLE
271 -1.54 41.45 13.43 4.22 ACCEPTABLE
272 -1.74 42.14 14.14 2.11 ACCEPTABLE
273 -1.49 41.91 13.86 4.44 ACCEPTABLE
274 -327.00 663.66 709.85 48.89 ACCEPTABLE
275 -1.64 41.79 13.78 2.10 ACCEPTABLE
276 -1.58 41.95 13.89 4.45 ACCEPTABLE
277 -1.69 41.78 13.68 7.61 ACCEPTABLE
278 -1.87 42.34 14.23 7.88 ACCEPTABLE
279 -1.66 42.10 13.98 8.90 ACCEPTABLE
280 -1.75 42.10 14.07 3.28 ACCEPTABLE
281 -1.38 41.57 13.64 2.10 ACCEPTABLE
282 -1.66 41.94 13.97 2.12 ACCEPTABLE
283 -1.50 41.79 13.78 3.28 ACCEPTABLE
284 -1.55 41.72 13.83 2.11 ACCEPTABLE
285 -1.62 41.64 13.59 4.20 ACCEPTABLE
286 -1.90 42.01 13.92 6.66 ACCEPTABLE
287 -1.73 41.87 13.74 10.94 ACCEPTABLE
288 -1.78 41.79 13.78 3.27 ACCEPTABLE
289 -1.50 41.34 13.45 2.11 ACCEPTABLE
290 -1.42 41.27 13.36 2.11 ACCEPTABLE
291 -1.70 41.62 13.67 2.12 ACCEPTABLE
292 -1.53 41.48 13.49 3.28 ACCEPTABLE

30
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
293 -1.59 41.41 13.54 2.13 ACCEPTABLE
294 -1.74 41.71 13.73 2.11 ACCEPTABLE
295 -1.57 41.56 13.54 3.17 ACCEPTABLE
296 -1.71 42.02 14.02 2.10 ACCEPTABLE
297 -1.65 42.19 14.13 3.28 ACCEPTABLE
298 -1.76 42.01 13.92 6.57 ACCEPTABLE
299 -1.94 42.57 14.48 6.34 ACCEPTABLE
300 -1.73 42.33 14.23 5.47 ACCEPTABLE
301 -1.82 42.34 14.32 3.28 ACCEPTABLE
302 -1.45 41.79 13.88 2.11 ACCEPTABLE
303 -1.73 42.17 14.21 2.12 ACCEPTABLE
304 -1.57 42.02 14.02 2.10 ACCEPTABLE
305 -1.62 41.95 14.06 2.12 ACCEPTABLE
306 -1.69 41.87 13.83 3.25 ACCEPTABLE
307 -1.97 42.24 14.17 6.69 ACCEPTABLE
308 -1.80 42.10 13.98 10.14 ACCEPTABLE
309 -1.85 42.02 14.02 3.27 ACCEPTABLE
310 -1.57 41.56 13.68 2.12 ACCEPTABLE
311 -1.49 41.49 13.59 2.12 ACCEPTABLE
312 -1.77 41.85 13.91 2.12 ACCEPTABLE
313 -1.60 41.71 13.73 2.10 ACCEPTABLE
314 -1.66 41.64 13.78 2.13 ACCEPTABLE
315 -1.81 41.94 13.97 2.11 ACCEPTABLE
316 -1.64 41.79 13.78 2.10 ACCEPTABLE
317 -1.78 42.25 14.26 2.11 ACCEPTABLE
318 -1.61 42.10 14.07 2.10 ACCEPTABLE
319 -1.55 42.27 14.18 5.57 ACCEPTABLE
320 -1.66 42.09 13.97 8.90 ACCEPTABLE
321 -1.84 42.66 14.53 8.51 ACCEPTABLE
322 -1.63 42.42 14.28 9.00 ACCEPTABLE
323 -1.72 42.42 14.37 2.10 ACCEPTABLE
324 -1.66 42.59 14.49 5.56 ACCEPTABLE
325 -1.77 42.41 14.27 9.01 ACCEPTABLE
326 -1.95 42.99 14.84 9.07 ACCEPTABLE
327 -1.74 42.75 14.59 10.13 ACCEPTABLE
328 -1.83 42.75 14.68 4.35 ACCEPTABLE
329 -1.46 42.19 14.22 2.10 ACCEPTABLE
330 -1.74 42.57 14.56 2.10 ACCEPTABLE
331 -1.58 42.42 14.37 3.17 ACCEPTABLE
332 -1.63 42.34 14.41 2.12 ACCEPTABLE
333 -1.70 42.27 14.18 5.36 ACCEPTABLE
334 -1.98 42.65 14.52 8.77 ACCEPTABLE
335 -1.82 42.50 14.34 11.29 ACCEPTABLE
336 -1.86 42.42 14.37 4.43 ACCEPTABLE
337 -1.58 41.95 14.02 2.12 ACCEPTABLE
338 -1.50 41.87 13.92 2.10 ACCEPTABLE
339 -1.77 42.24 14.25 2.12 ACCEPTABLE
340 -1.61 42.09 14.07 2.10 ACCEPTABLE
341 -1.66 42.02 14.11 2.12 ACCEPTABLE
342 -1.82 42.33 14.31 3.29 ACCEPTABLE
343 -1.65 42.18 14.12 3.28 ACCEPTABLE
344 -1.79 42.66 14.62 2.10 ACCEPTABLE
345 -1.62 42.51 14.43 4.42 ACCEPTABLE

31
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
346 -327.85 667.21 713.31 49.66 ACCEPTABLE
347 -327.71 667.21 713.31 48.27 ACCEPTABLE
348 -1.72 42.42 14.37 2.10 ACCEPTABLE
349 -1.68 42.54 14.45 4.32 ACCEPTABLE
350 -1.75 42.41 14.31 4.42 ACCEPTABLE
351 -1.87 42.80 14.68 6.75 ACCEPTABLE
352 -1.73 42.64 14.51 7.88 ACCEPTABLE
353 -1.79 42.64 14.58 3.29 ACCEPTABLE
354 -1.55 42.27 14.27 2.10 ACCEPTABLE
355 -1.73 42.52 14.50 2.10 ACCEPTABLE
356 -1.62 42.42 14.37 2.09 ACCEPTABLE
357 -1.58 42.54 14.45 4.25 ACCEPTABLE
358 -1.65 42.41 14.31 4.41 ACCEPTABLE
359 -1.77 42.80 14.68 6.62 ACCEPTABLE
360 -1.63 42.64 14.51 7.90 ACCEPTABLE
361 -1.69 42.64 14.58 2.10 ACCEPTABLE
362 -1.45 42.27 14.27 2.10 ACCEPTABLE
363 -1.63 42.52 14.50 2.10 ACCEPTABLE
364 -1.52 42.42 14.37 3.17 ACCEPTABLE
365 -1.56 42.37 14.39 2.11 ACCEPTABLE
366 -1.61 42.32 14.24 3.28 ACCEPTABLE
367 -1.79 42.57 14.47 5.58 ACCEPTABLE
368 -1.68 42.48 14.35 7.63 ACCEPTABLE
369 -1.72 42.42 14.37 2.10 ACCEPTABLE
370 -1.53 42.10 14.13 2.10 ACCEPTABLE
371 -1.47 42.05 14.07 2.09 ACCEPTABLE
372 -1.43 42.16 14.14 3.17 ACCEPTABLE
373 -1.50 42.04 14.01 3.27 ACCEPTABLE
374 -1.62 42.42 14.37 2.09 ACCEPTABLE
375 -1.48 42.26 14.21 4.24 ACCEPTABLE
376 -1.54 42.26 14.27 2.11 ACCEPTABLE
377 -1.30 41.90 13.97 2.11 ACCEPTABLE
378 -1.49 42.15 14.20 2.10 ACCEPTABLE
379 -1.37 42.05 14.07 2.09 ACCEPTABLE
380 -1.33 42.16 14.14 4.23 ACCEPTABLE
381 -1.40 42.04 14.01 5.29 ACCEPTABLE
382 -1.52 42.42 14.37 3.17 ACCEPTABLE
383 -1.38 42.26 14.21 5.30 ACCEPTABLE
384 -1.44 42.26 14.27 2.10 ACCEPTABLE
385 -1.20 41.90 13.97 3.16 ACCEPTABLE
386 -1.39 42.15 14.20 2.10 ACCEPTABLE
387 -1.27 42.05 14.07 3.27 ACCEPTABLE
388 -1.31 42.00 14.10 2.11 ACCEPTABLE
389 -1.35 41.95 13.94 4.43 ACCEPTABLE
390 -1.54 42.20 14.17 2.09 ACCEPTABLE
391 -1.43 42.10 14.04 5.61 ACCEPTABLE
392 -1.47 42.05 14.07 2.09 ACCEPTABLE
393 -1.28 41.74 13.84 2.11 ACCEPTABLE
394 -1.22 41.69 13.78 2.10 ACCEPTABLE
395 -1.41 41.94 14.00 2.10 ACCEPTABLE
396 -1.30 41.84 13.87 3.27 ACCEPTABLE
397 -1.34 41.79 13.91 2.11 ACCEPTABLE
398 -1.44 41.99 14.03 2.10 ACCEPTABLE

32
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
399 -1.33 41.90 13.91 4.22 ACCEPTABLE
400 -1.41 42.21 14.23 2.10 ACCEPTABLE
401 -1.30 42.11 14.11 4.23 ACCEPTABLE
402 -333.58 698.37 743.72 49.46 ACCEPTABLE
403 -335.35 708.29 753.42 48.43 ACCEPTABLE
404 -333.49 698.37 743.72 48.07 ACCEPTABLE
405 -1.37 42.05 14.07 2.09 ACCEPTABLE
406 -1.34 42.12 14.12 3.27 ACCEPTABLE
407 -1.39 42.05 14.03 4.44 ACCEPTABLE
408 -1.47 42.29 14.27 3.28 ACCEPTABLE
409 -1.38 42.19 14.16 4.44 ACCEPTABLE
410 -1.42 42.19 14.20 2.10 ACCEPTABLE
411 -1.26 41.95 14.01 3.27 ACCEPTABLE
412 -1.38 42.12 14.15 2.10 ACCEPTABLE
413 -1.31 42.05 14.07 4.23 ACCEPTABLE
414 -1.33 42.02 14.09 2.10 ACCEPTABLE
415 -1.36 41.98 13.99 3.27 ACCEPTABLE
416 -1.48 42.15 14.14 3.28 ACCEPTABLE
417 -1.41 42.08 14.05 4.44 ACCEPTABLE
418 -1.43 42.05 14.07 2.10 ACCEPTABLE
419 -1.31 41.84 13.92 2.10 ACCEPTABLE
420 -1.27 41.81 13.88 2.10 ACCEPTABLE
421 -1.40 41.97 14.02 2.09 ACCEPTABLE
422 -1.32 41.91 13.94 3.16 ACCEPTABLE
423 -1.35 41.88 13.96 2.10 ACCEPTABLE
424 -1.42 42.01 14.05 2.10 ACCEPTABLE
425 -1.34 41.95 13.96 4.22 ACCEPTABLE
426 -1.40 42.15 14.18 2.10 ACCEPTABLE
427 -1.32 42.09 14.09 4.23 ACCEPTABLE
428 -333.09 697.23 742.61 47.38 ACCEPTABLE
429 -1.37 42.05 14.07 2.09 ACCEPTABLE
430 -1.35 42.10 14.10 3.27 ACCEPTABLE
431 -1.38 42.05 14.04 3.16 ACCEPTABLE
432 -1.44 42.21 14.20 3.28 ACCEPTABLE
433 -1.37 42.14 14.13 3.17 ACCEPTABLE
434 -1.40 42.14 14.16 2.10 ACCEPTABLE
435 -1.29 41.98 14.03 3.27 ACCEPTABLE
436 -1.38 42.09 14.13 2.10 ACCEPTABLE
437 -1.33 42.05 14.07 3.16 ACCEPTABLE
438 -1.34 42.03 14.08 2.10 ACCEPTABLE
439 -1.36 42.01 14.01 4.44 ACCEPTABLE
440 -1.45 42.12 14.11 3.28 ACCEPTABLE
441 -1.40 42.07 14.06 4.44 ACCEPTABLE
442 -1.41 42.05 14.07 3.17 ACCEPTABLE
443 -1.33 41.91 13.97 2.10 ACCEPTABLE
444 -1.30 41.89 13.94 3.27 ACCEPTABLE
445 -1.39 42.00 14.04 2.10 ACCEPTABLE
446 -1.34 41.96 13.98 3.16 ACCEPTABLE
447 -1.35 41.93 14.00 2.11 ACCEPTABLE
448 -1.40 42.03 14.05 3.17 ACCEPTABLE
449 -1.35 41.98 14.00 3.16 ACCEPTABLE
450 -1.39 42.12 14.14 2.10 ACCEPTABLE
451 -1.34 42.07 14.09 3.16 ACCEPTABLE

33
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
452 -332.90 696.14 741.54 47.42 ACCEPTABLE
453 -9.12 84.71 56.25 76.46 ACCEPTABLE
454 -2.01 53.69 30.29 2.49 ACCEPTABLE
455 -3.75 74.35 51.04 2.93 ACCEPTABLE
456 9.38 49.57 26.41 3.10 ACCEPTABLE
457 1.28 44.23 33.00 2.50 ACCEPTABLE
458 -9.90 42.74 22.61 3.07 ACCEPTABLE
459 9.68 48.34 25.71 3.14 ACCEPTABLE
460 -462.28 1525.80 1563.66 34.67 ACCEPTABLE
461 -2.01 53.69 30.29 2.49 ACCEPTABLE
462 8.38 44.61 25.36 2.84 ACCEPTABLE
463 -2.59 48.39 21.04 2.34 ACCEPTABLE
464 -7.50 77.67 49.76 17.52 ACCEPTABLE
465 -3.24 59.06 34.08 2.65 ACCEPTABLE
466 5.72 48.39 21.04 29.85 ACCEPTABLE
467 -0.03 45.06 25.55 2.40 ACCEPTABLE
468 -89.60 142.18 141.58 47.82 ACCEPTABLE
469 -10.90 48.39 21.04 36.64 ACCEPTABLE
470 -8.14 40.76 16.55 3.21 ACCEPTABLE
471 -5.93 70.81 43.66 3.07 ACCEPTABLE
472 5.13 50.03 22.27 33.55 ACCEPTABLE
473 -2.59 48.39 21.04 2.34 ACCEPTABLE
474 3.82 45.98 19.37 10.81 ACCEPTABLE
475 -2.34 42.74 13.78 94.69 ACCEPTABLE
476 -39.08 193.42 165.22 40.98 ACCEPTABLE
477 -23.68 122.03 94.01 32.13 ACCEPTABLE
478 -6.00 66.70 38.87 10.00 ACCEPTABLE
479 -3.11 55.61 29.77 2.57 ACCEPTABLE
480 2.95 48.39 21.04 16.60 ACCEPTABLE
481 -0.52 45.68 23.46 2.38 ACCEPTABLE
482 -14.14 65.02 35.58 40.29 ACCEPTABLE
483 -20.54 73.69 46.27 39.49 ACCEPTABLE
484 -8.13 48.39 21.04 36.60 ACCEPTABLE
485 -6.39 43.59 17.92 2.72 ACCEPTABLE
486 -4.83 62.22 35.03 2.80 ACCEPTABLE
487 2.06 50.83 22.90 22.80 ACCEPTABLE
488 -2.59 48.39 21.04 2.34 ACCEPTABLE
489 0.32 50.54 22.67 3.63 ACCEPTABLE
490 -3.43 46.62 17.72 87.18 ACCEPTABLE
491 -13.24 88.88 59.34 31.43 ACCEPTABLE
492 -6.72 70.02 40.46 29.14 ACCEPTABLE
493 -4.93 60.02 32.29 2.72 ACCEPTABLE
494 3.89 40.69 16.53 2.56 ACCEPTABLE
495 -2.99 53.26 26.89 2.51 ACCEPTABLE
496 1.10 48.39 21.04 2.32 ACCEPTABLE
497 4.01 50.54 22.67 33.55 ACCEPTABLE
498 0.26 46.62 17.72 79.03 ACCEPTABLE
499 -9.55 88.88 59.34 28.41 ACCEPTABLE
500 -3.03 70.02 40.46 27.29 ACCEPTABLE
501 -1.24 60.02 32.29 2.58 ACCEPTABLE
502 7.58 40.69 16.53 18.98 ACCEPTABLE
503 0.70 53.26 26.89 2.48 ACCEPTABLE
504 4.79 48.39 21.04 28.51 ACCEPTABLE

34
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
505 2.72 46.27 22.27 2.43 ACCEPTABLE
506 2.15 42.73 14.80 31.10 ACCEPTABLE
507 -6.10 58.09 29.11 83.77 ACCEPTABLE
508 -4.03 55.45 25.86 29.32 ACCEPTABLE
509 -2.59 48.39 21.04 2.34 ACCEPTABLE
510 -0.18 41.73 16.97 2.30 ACCEPTABLE
511 3.95 40.51 16.45 2.57 ACCEPTABLE
512 -0.41 40.43 13.43 2.19 ACCEPTABLE
513 -8.03 63.43 34.06 30.60 ACCEPTABLE
514 -2.03 51.34 21.90 76.68 ACCEPTABLE
515 -2.45 48.03 20.77 2.33 ACCEPTABLE
516 -1.01 44.04 18.17 2.28 ACCEPTABLE
517 3.28 40.43 13.43 23.71 ACCEPTABLE
518 -6.25 44.84 16.30 94.25 ACCEPTABLE
519 -3.63 42.81 13.25 35.26 ACCEPTABLE
520 -4.10 40.43 13.43 2.47 ACCEPTABLE
521 -1.93 46.58 19.77 2.30 ACCEPTABLE
522 3.00 41.01 13.74 25.60 ACCEPTABLE
523 -381.49 955.56 996.93 56.10 ACCEPTABLE
524 -377.80 955.56 996.93 43.01 ACCEPTABLE
525 -0.41 40.43 13.43 2.19 ACCEPTABLE
526 1.92 40.70 13.57 18.17 ACCEPTABLE
527 -4.49 52.03 23.31 80.93 ACCEPTABLE
528 -0.77 46.23 17.40 87.04 ACCEPTABLE
529 -1.82 45.29 18.08 2.26 ACCEPTABLE
530 -0.87 42.88 16.59 2.25 ACCEPTABLE
531 2.05 40.43 13.43 17.11 ACCEPTABLE
532 -4.39 43.56 15.36 39.34 ACCEPTABLE
533 -1.99 41.63 12.65 99.35 ACCEPTABLE
534 -2.87 40.43 13.43 2.31 ACCEPTABLE
535 -1.44 44.33 17.46 2.25 ACCEPTABLE
536 1.76 41.02 13.75 19.13 ACCEPTABLE
537 -319.00 616.65 664.18 53.36 ACCEPTABLE
538 -365.17 879.57 921.83 44.24 ACCEPTABLE
539 -316.54 616.65 664.18 41.45 ACCEPTABLE
540 -0.41 40.43 13.43 2.19 ACCEPTABLE
541 0.93 41.04 13.76 10.43 ACCEPTABLE
542 -0.69 40.05 12.06 15.10 ACCEPTABLE
543 -2.85 47.08 18.89 13.59 ACCEPTABLE
544 -0.44 43.87 15.59 24.39 ACCEPTABLE
545 -1.37 43.57 16.42 2.22 ACCEPTABLE
546 -0.75 42.09 15.54 2.24 ACCEPTABLE
547 1.23 40.43 13.43 7.40 ACCEPTABLE
548 -3.10 42.58 14.70 10.78 ACCEPTABLE
549 -1.30 41.12 12.72 43.70 ACCEPTABLE
550 -2.05 40.43 13.43 2.24 ACCEPTABLE
551 -1.10 42.94 16.03 2.23 ACCEPTABLE
552 1.00 40.90 13.68 8.60 ACCEPTABLE
553 -326.17 656.26 702.65 51.59 ACCEPTABLE
554 -357.02 831.54 874.46 43.79 ACCEPTABLE
555 -324.53 656.26 702.65 43.29 ACCEPTABLE
556 -0.41 40.43 13.43 2.19 ACCEPTABLE
557 0.41 40.99 13.73 2.19 ACCEPTABLE

35
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
558 1.17 41.67 14.13 18.46 ACCEPTABLE
559 0.17 40.80 12.86 22.56 ACCEPTABLE
560 -1.21 45.30 17.25 2.13 ACCEPTABLE
561 -0.78 46.80 18.38 31.36 ACCEPTABLE
562 -1.61 45.14 16.54 86.05 ACCEPTABLE
563 -3.31 51.49 22.73 83.65 ACCEPTABLE
564 -1.66 48.80 20.00 84.57 ACCEPTABLE
565 -2.06 48.39 20.19 5.72 ACCEPTABLE
566 0.82 43.17 15.80 4.78 ACCEPTABLE
567 -1.32 46.56 18.80 2.22 ACCEPTABLE
568 -0.12 45.30 17.25 15.02 ACCEPTABLE
569 -0.52 44.57 17.43 2.23 ACCEPTABLE
570 -1.05 43.99 15.68 22.52 ACCEPTABLE
571 -3.26 47.46 18.91 59.98 ACCEPTABLE
572 -2.20 46.35 17.50 89.36 ACCEPTABLE
573 -2.30 45.30 17.25 4.62 ACCEPTABLE
574 -0.25 41.56 14.45 2.18 ACCEPTABLE
575 0.41 40.99 13.74 2.18 ACCEPTABLE
576 -1.52 43.53 16.03 2.19 ACCEPTABLE
577 -0.33 42.52 14.66 9.33 ACCEPTABLE
578 -0.90 42.12 15.16 2.21 ACCEPTABLE
579 -1.92 44.44 16.64 2.18 ACCEPTABLE
580 -0.71 43.29 15.18 13.16 ACCEPTABLE
581 -1.71 47.51 19.51 2.20 ACCEPTABLE
582 -0.47 46.09 17.84 17.56 ACCEPTABLE
583 -1.21 45.30 17.25 2.13 ACCEPTABLE
584 -0.94 46.34 18.03 18.02 ACCEPTABLE
585 -1.49 45.24 16.80 37.59 ACCEPTABLE
586 -2.54 49.14 20.61 49.26 ACCEPTABLE
587 -1.45 47.50 18.94 61.20 ACCEPTABLE
588 -1.78 47.33 19.17 2.17 ACCEPTABLE
589 0.15 43.88 16.26 3.47 ACCEPTABLE
590 -1.29 46.14 18.29 2.19 ACCEPTABLE
591 -0.48 45.30 17.25 10.12 ACCEPTABLE
592 -0.73 44.78 17.33 2.20 ACCEPTABLE
593 -1.11 44.44 16.20 14.07 ACCEPTABLE
594 -2.57 46.74 18.33 30.65 ACCEPTABLE
595 -1.82 45.95 17.35 85.52 ACCEPTABLE
596 -1.94 45.30 17.25 2.15 ACCEPTABLE
597 -0.53 42.67 15.24 2.17 ACCEPTABLE
598 -0.09 42.27 14.75 2.16 ACCEPTABLE
599 -1.43 44.14 16.44 2.17 ACCEPTABLE
600 -0.63 43.41 15.48 6.88 ACCEPTABLE
601 -0.95 43.06 15.73 2.19 ACCEPTABLE
602 -1.69 44.73 16.84 2.17 ACCEPTABLE
603 -0.88 43.94 15.85 10.51 ACCEPTABLE
604 -1.54 46.75 18.73 2.18 ACCEPTABLE
605 -0.72 45.84 17.65 13.52 ACCEPTABLE
606 -355.33 821.62 864.69 45.75 ACCEPTABLE
607 -354.60 821.62 864.69 41.88 ACCEPTABLE
608 -1.21 45.30 17.25 2.13 ACCEPTABLE
609 -1.04 46.01 17.78 12.04 ACCEPTABLE
610 -1.40 45.28 16.96 19.48 ACCEPTABLE

36
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
611 -2.07 47.75 19.38 22.02 ACCEPTABLE
612 -1.35 46.71 18.31 27.82 ACCEPTABLE
613 -1.59 46.64 18.51 2.15 ACCEPTABLE
614 -0.30 44.35 16.58 2.16 ACCEPTABLE
615 -1.27 45.86 17.94 2.17 ACCEPTABLE
616 -0.72 45.30 17.25 7.70 ACCEPTABLE
617 -0.88 44.94 17.29 2.19 ACCEPTABLE
618 -1.15 44.73 16.55 9.90 ACCEPTABLE
619 -2.12 46.26 17.96 17.02 ACCEPTABLE
620 -1.60 45.72 17.29 33.77 ACCEPTABLE
621 -1.70 45.30 17.25 2.14 ACCEPTABLE
622 -0.73 43.48 15.84 2.16 ACCEPTABLE
623 -0.45 43.21 15.50 2.14 ACCEPTABLE
624 -1.36 44.54 16.71 2.16 ACCEPTABLE
625 -0.82 44.03 16.06 4.52 ACCEPTABLE
626 -1.01 43.75 16.17 2.16 ACCEPTABLE
627 -1.53 44.93 16.98 2.15 ACCEPTABLE
628 -0.99 44.38 16.31 7.61 ACCEPTABLE
629 -1.43 46.26 18.23 2.16 ACCEPTABLE
630 -0.88 45.66 17.52 9.55 ACCEPTABLE
631 -367.41 892.85 934.94 42.34 ACCEPTABLE
632 -1.21 45.30 17.25 2.13 ACCEPTABLE
633 -1.10 45.78 17.60 8.90 ACCEPTABLE
634 -1.34 45.29 17.06 10.70 ACCEPTABLE
635 -1.77 46.89 18.62 12.09 ACCEPTABLE
636 -1.29 46.22 17.94 13.24 ACCEPTABLE
637 -1.47 46.18 18.09 2.15 ACCEPTABLE
638 -0.61 44.67 16.80 3.36 ACCEPTABLE
639 -1.25 45.68 17.71 2.16 ACCEPTABLE
640 -0.89 45.30 17.25 5.48 ACCEPTABLE
641 -0.98 45.06 17.27 2.17 ACCEPTABLE
642 -1.17 44.92 16.79 7.01 ACCEPTABLE
643 -1.82 45.94 17.72 8.15 ACCEPTABLE
644 -1.46 45.57 17.27 18.09 ACCEPTABLE
645 -1.53 45.30 17.25 2.14 ACCEPTABLE
646 -0.88 44.05 16.27 2.15 ACCEPTABLE
647 -0.69 43.87 16.05 2.14 ACCEPTABLE
648 -1.31 44.80 16.89 2.15 ACCEPTABLE
649 -0.95 44.44 16.45 4.33 ACCEPTABLE
650 -1.07 44.24 16.50 2.16 ACCEPTABLE
651 -1.42 45.05 17.07 2.15 ACCEPTABLE
652 -1.06 44.68 16.62 5.77 ACCEPTABLE
653 -1.36 45.93 17.90 2.16 ACCEPTABLE
654 -0.99 45.54 17.43 6.61 ACCEPTABLE
655 -365.78 883.14 925.35 44.33 ACCEPTABLE
656 -1.21 45.30 17.25 2.13 ACCEPTABLE
657 -1.14 45.62 17.49 5.84 ACCEPTABLE
658 -1.30 45.30 17.13 7.05 ACCEPTABLE
659 -1.58 46.34 18.14 3.40 ACCEPTABLE
660 -1.26 45.90 17.70 7.10 ACCEPTABLE
661 -1.38 45.89 17.80 2.14 ACCEPTABLE
662 -0.81 44.88 16.95 3.37 ACCEPTABLE
663 -1.24 45.55 17.56 2.15 ACCEPTABLE

37
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
664 -0.99 45.30 17.25 4.37 ACCEPTABLE
665 -1.06 45.14 17.26 2.16 ACCEPTABLE
666 -1.18 45.05 16.94 5.46 ACCEPTABLE
667 -1.61 45.72 17.56 3.38 ACCEPTABLE
668 -1.38 45.48 17.26 10.05 ACCEPTABLE
669 -1.43 45.30 17.25 2.13 ACCEPTABLE
670 -1.36 45.62 17.49 4.62 ACCEPTABLE
671 -1.52 45.30 17.13 4.59 ACCEPTABLE
672 -1.80 46.34 18.14 4.39 ACCEPTABLE
673 -1.48 45.90 17.70 5.87 ACCEPTABLE
674 -1.60 45.89 17.80 2.15 ACCEPTABLE
675 -1.03 44.88 16.95 2.14 ACCEPTABLE
676 -1.46 45.55 17.56 2.16 ACCEPTABLE
677 -1.21 45.30 17.25 2.13 ACCEPTABLE
678 -1.28 45.14 17.26 2.16 ACCEPTABLE
679 -1.40 45.05 16.94 3.25 ACCEPTABLE
680 -1.83 45.72 17.56 4.58 ACCEPTABLE
681 -1.60 45.48 17.26 9.99 ACCEPTABLE
682 -1.65 45.30 17.25 2.14 ACCEPTABLE
683 -1.20 44.45 16.58 2.14 ACCEPTABLE
684 -1.08 44.33 16.43 2.14 ACCEPTABLE
685 -1.50 44.97 17.01 2.15 ACCEPTABLE
686 -1.26 44.73 16.71 2.13 ACCEPTABLE
687 -1.18 45.04 16.93 5.47 ACCEPTABLE
688 -1.34 44.73 16.58 6.99 ACCEPTABLE
689 -1.62 45.73 17.57 3.38 ACCEPTABLE
690 -1.30 45.31 17.13 7.72 ACCEPTABLE
691 -1.43 45.30 17.24 2.14 ACCEPTABLE
692 -0.86 44.32 16.42 2.13 ACCEPTABLE
693 -1.29 44.98 17.01 2.14 ACCEPTABLE
694 -1.04 44.73 16.71 3.35 ACCEPTABLE
695 -1.11 44.58 16.73 2.15 ACCEPTABLE
696 -1.23 44.48 16.41 4.55 ACCEPTABLE
697 -1.66 45.14 17.00 2.12 ACCEPTABLE
698 -1.59 45.47 17.24 9.01 ACCEPTABLE
699 -1.75 45.14 16.88 13.73 ACCEPTABLE
700 -2.03 46.18 17.90 14.47 ACCEPTABLE
701 -1.72 45.75 17.45 18.56 ACCEPTABLE
702 -1.83 45.73 17.56 5.79 ACCEPTABLE
703 -1.25 44.72 16.70 2.12 ACCEPTABLE
704 -1.68 45.39 17.30 2.13 ACCEPTABLE
705 -1.44 45.14 17.00 4.37 ACCEPTABLE
706 -1.50 44.97 17.00 2.15 ACCEPTABLE
707 -1.63 44.89 16.70 6.72 ACCEPTABLE
708 -2.07 45.56 17.31 12.12 ACCEPTABLE
709 -1.83 45.32 17.01 19.65 ACCEPTABLE
710 -1.88 45.14 17.00 4.55 ACCEPTABLE
711 -1.43 44.29 16.33 2.13 ACCEPTABLE
712 -1.30 44.17 16.18 2.12 ACCEPTABLE
713 -1.72 44.80 16.75 2.13 ACCEPTABLE
714 -1.48 44.56 16.46 3.34 ACCEPTABLE
715 -1.55 44.41 16.48 2.14 ACCEPTABLE
716 -1.80 44.97 16.88 2.13 ACCEPTABLE

38
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
717 -1.56 44.73 16.58 4.56 ACCEPTABLE
718 -1.76 45.56 17.43 3.36 ACCEPTABLE
719 -1.52 45.31 17.12 6.57 ACCEPTABLE
720 -364.70 876.70 919.00 44.04 ACCEPTABLE
721 -1.66 45.14 17.00 2.12 ACCEPTABLE
722 -1.62 45.36 17.16 6.77 ACCEPTABLE
723 -1.72 45.14 16.92 9.37 ACCEPTABLE
724 -1.91 45.83 17.59 9.36 ACCEPTABLE
725 -1.70 45.54 17.30 10.31 ACCEPTABLE
726 -1.78 45.53 17.37 4.56 ACCEPTABLE
727 -1.39 44.86 16.80 2.13 ACCEPTABLE
728 -1.68 45.30 17.20 2.14 ACCEPTABLE
729 -1.52 45.14 17.00 3.25 ACCEPTABLE
730 -1.55 45.03 17.00 2.14 ACCEPTABLE
731 -1.64 44.97 16.80 5.54 ACCEPTABLE
732 -1.93 45.42 17.21 8.14 ACCEPTABLE
733 -1.77 45.26 17.01 13.01 ACCEPTABLE
734 -1.80 45.14 17.00 4.54 ACCEPTABLE
735 -1.50 44.57 16.55 2.13 ACCEPTABLE
736 -1.42 44.49 16.45 2.11 ACCEPTABLE
737 -1.37 44.69 16.60 3.24 ACCEPTABLE
738 -1.48 44.49 16.36 4.33 ACCEPTABLE
739 -1.66 45.14 17.00 2.12 ACCEPTABLE
740 -1.45 44.87 16.72 4.57 ACCEPTABLE
741 -1.53 44.86 16.80 2.13 ACCEPTABLE
742 -1.15 44.22 16.26 2.13 ACCEPTABLE
743 -1.44 44.65 16.65 2.13 ACCEPTABLE
744 -1.28 44.49 16.45 3.34 ACCEPTABLE
745 -1.32 44.39 16.46 2.14 ACCEPTABLE
746 -1.40 44.33 16.25 3.33 ACCEPTABLE
747 -1.69 44.76 16.64 2.11 ACCEPTABLE
748 -1.64 44.97 16.80 5.54 ACCEPTABLE
749 -1.75 44.76 16.56 9.28 ACCEPTABLE
750 -1.93 45.43 17.21 9.46 ACCEPTABLE
751 -1.72 45.15 16.92 10.57 ACCEPTABLE
752 -1.81 45.14 17.00 4.54 ACCEPTABLE
753 -1.42 44.49 16.44 2.11 ACCEPTABLE
754 -1.71 44.92 16.84 2.12 ACCEPTABLE
755 -1.55 44.76 16.64 3.23 ACCEPTABLE
756 -1.59 44.65 16.65 2.13 ACCEPTABLE
757 -1.67 44.60 16.44 4.52 ACCEPTABLE
758 -1.96 45.03 16.84 8.11 ACCEPTABLE
759 -1.80 44.87 16.64 11.04 ACCEPTABLE
760 -1.83 44.76 16.64 3.22 ACCEPTABLE
761 -1.54 44.20 16.20 2.12 ACCEPTABLE
762 -1.45 44.12 16.10 2.12 ACCEPTABLE
763 -1.73 44.54 16.48 2.13 ACCEPTABLE
764 -1.57 44.38 16.29 2.11 ACCEPTABLE
765 -1.62 44.28 16.30 2.13 ACCEPTABLE
766 -1.78 44.65 16.56 2.13 ACCEPTABLE
767 -1.62 44.49 16.36 3.23 ACCEPTABLE
768 -1.76 45.03 16.92 2.13 ACCEPTABLE
769 -1.60 44.87 16.72 3.35 ACCEPTABLE

39
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
770 -356.70 828.50 871.46 46.01 ACCEPTABLE
771 -356.56 828.50 871.46 46.00 ACCEPTABLE
772 -1.69 44.76 16.64 2.11 ACCEPTABLE
773 -1.66 44.90 16.74 4.55 ACCEPTABLE
774 -1.73 44.76 16.58 6.79 ACCEPTABLE
775 -1.85 45.20 17.02 5.45 ACCEPTABLE
776 -1.71 45.02 16.83 7.93 ACCEPTABLE
777 -1.77 45.01 16.88 3.34 ACCEPTABLE
778 -1.51 44.58 16.51 2.12 ACCEPTABLE
779 -1.70 44.87 16.77 2.12 ACCEPTABLE
780 -1.59 44.76 16.64 3.23 ACCEPTABLE
781 -1.62 44.69 16.64 2.12 ACCEPTABLE
782 -1.68 44.65 16.51 3.32 ACCEPTABLE
783 -1.87 44.94 16.77 5.72 ACCEPTABLE
784 -1.76 44.83 16.64 8.09 ACCEPTABLE
785 -1.79 44.76 16.64 3.22 ACCEPTABLE
786 -1.59 44.39 16.34 2.11 ACCEPTABLE
787 -1.53 44.33 16.28 2.12 ACCEPTABLE
788 -1.72 44.61 16.54 2.12 ACCEPTABLE
789 -1.61 44.51 16.40 2.11 ACCEPTABLE
790 -1.58 44.65 16.50 4.56 ACCEPTABLE
791 -1.65 44.51 16.34 6.68 ACCEPTABLE
792 -1.77 44.95 16.77 4.52 ACCEPTABLE
793 -1.63 44.76 16.58 6.70 ACCEPTABLE
794 -1.69 44.76 16.64 2.11 ACCEPTABLE
795 -1.43 44.33 16.27 2.11 ACCEPTABLE
796 -1.62 44.62 16.53 2.12 ACCEPTABLE
797 -1.51 44.51 16.40 3.34 ACCEPTABLE
798 -1.54 44.44 16.41 2.12 ACCEPTABLE
799 -1.60 44.40 16.27 3.34 ACCEPTABLE
800 -1.79 44.69 16.53 4.50 ACCEPTABLE
801 -1.68 44.58 16.40 6.91 ACCEPTABLE
802 -1.71 44.51 16.40 2.11 ACCEPTABLE
803 -1.51 44.14 16.11 2.12 ACCEPTABLE
804 -1.45 44.09 16.04 2.12 ACCEPTABLE
805 -1.64 44.37 16.30 2.11 ACCEPTABLE
806 -1.53 44.26 16.17 2.11 ACCEPTABLE
807 -1.50 44.40 16.27 3.33 ACCEPTABLE
808 -1.57 44.26 16.11 4.32 ACCEPTABLE
809 -1.69 44.69 16.53 4.53 ACCEPTABLE
810 -1.55 44.51 16.35 5.72 ACCEPTABLE
811 -1.61 44.51 16.40 2.11 ACCEPTABLE
812 -1.35 44.08 16.05 2.12 ACCEPTABLE
813 -1.54 44.37 16.30 2.11 ACCEPTABLE
814 -1.43 44.26 16.17 3.22 ACCEPTABLE
815 -1.46 44.19 16.18 2.12 ACCEPTABLE
816 -1.52 44.15 16.04 3.22 ACCEPTABLE
817 -1.71 44.44 16.30 4.31 ACCEPTABLE
818 -1.60 44.33 16.16 6.59 ACCEPTABLE
819 -1.63 44.26 16.17 2.11 ACCEPTABLE
820 -1.43 43.90 15.89 2.11 ACCEPTABLE
821 -1.37 43.85 15.82 2.11 ACCEPTABLE
822 -1.56 44.12 16.07 2.11 ACCEPTABLE

40
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
823 -1.45 44.02 15.94 2.11 ACCEPTABLE
824 -1.48 43.95 15.95 2.12 ACCEPTABLE
825 -1.59 44.19 16.12 2.11 ACCEPTABLE
826 -1.49 44.08 15.99 3.32 ACCEPTABLE
827 -1.57 44.44 16.35 2.12 ACCEPTABLE
828 -1.47 44.33 16.22 3.33 ACCEPTABLE
829 -354.31 814.57 857.74 46.28 ACCEPTABLE
830 -356.19 825.52 868.53 46.33 ACCEPTABLE
831 -354.21 814.57 857.74 46.00 ACCEPTABLE
832 -1.53 44.26 16.17 2.11 ACCEPTABLE
833 -1.51 44.35 16.24 3.33 ACCEPTABLE
834 -1.55 44.26 16.13 4.32 ACCEPTABLE
835 -1.64 44.54 16.41 3.31 ACCEPTABLE
836 -1.54 44.42 16.29 3.34 ACCEPTABLE
837 -1.58 44.42 16.32 2.11 ACCEPTABLE
838 -1.56 44.51 16.39 3.34 ACCEPTABLE
839 -1.61 44.42 16.28 3.22 ACCEPTABLE
840 -1.69 44.71 16.56 4.53 ACCEPTABLE
841 -1.59 44.59 16.44 4.42 ACCEPTABLE
842 -1.63 44.59 16.48 2.12 ACCEPTABLE
843 -1.46 44.30 16.24 2.11 ACCEPTABLE
844 -1.59 44.49 16.41 2.12 ACCEPTABLE
845 -1.52 44.42 16.32 3.34 ACCEPTABLE
846 -1.53 44.37 16.32 2.12 ACCEPTABLE
847 -1.57 44.35 16.23 3.22 ACCEPTABLE
848 -1.70 44.54 16.41 3.32 ACCEPTABLE
849 -1.63 44.47 16.32 4.30 ACCEPTABLE
850 -1.64 44.42 16.32 2.11 ACCEPTABLE
851 -1.51 44.17 16.13 2.12 ACCEPTABLE
852 -1.48 44.14 16.08 2.11 ACCEPTABLE
853 -1.60 44.33 16.25 2.11 ACCEPTABLE
854 -1.53 44.26 16.17 2.11 ACCEPTABLE
855 -1.55 44.21 16.17 2.12 ACCEPTABLE
856 -1.62 44.37 16.29 2.11 ACCEPTABLE
857 -1.55 44.30 16.20 3.33 ACCEPTABLE
858 -1.61 44.54 16.44 2.11 ACCEPTABLE
859 -1.54 44.47 16.35 3.34 ACCEPTABLE
860 -351.93 801.96 845.34 45.52 ACCEPTABLE
861 -1.58 44.42 16.32 2.11 ACCEPTABLE
862 -1.57 44.48 16.36 3.23 ACCEPTABLE
863 -1.60 44.42 16.29 3.34 ACCEPTABLE
864 -1.65 44.61 16.48 2.10 ACCEPTABLE
865 -1.64 44.67 16.53 3.23 ACCEPTABLE
866 -1.67 44.61 16.46 5.70 ACCEPTABLE
867 -1.72 44.80 16.64 4.54 ACCEPTABLE
868 -1.66 44.72 16.56 4.53 ACCEPTABLE
869 -1.68 44.72 16.59 3.21 ACCEPTABLE
870 -1.57 44.53 16.42 2.12 ACCEPTABLE
871 -1.66 44.66 16.54 2.11 ACCEPTABLE
872 -1.61 44.61 16.48 3.23 ACCEPTABLE
873 -1.62 44.58 16.48 2.11 ACCEPTABLE
874 -1.64 44.56 16.42 2.11 ACCEPTABLE
875 -1.73 44.69 16.54 4.29 ACCEPTABLE

41
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
876 -1.68 44.64 16.48 4.53 ACCEPTABLE
877 -1.69 44.61 16.48 3.31 ACCEPTABLE
878 -1.60 44.44 16.35 2.12 ACCEPTABLE
879 -1.58 44.42 16.32 2.11 ACCEPTABLE
880 -1.66 44.55 16.43 2.11 ACCEPTABLE
881 -1.62 44.50 16.38 2.11 ACCEPTABLE
882 -1.63 44.47 16.38 2.11 ACCEPTABLE
883 -1.68 44.58 16.46 2.11 ACCEPTABLE
884 -1.63 44.53 16.40 2.11 ACCEPTABLE
885 -1.67 44.69 16.56 2.11 ACCEPTABLE
886 -1.62 44.64 16.50 2.11 ACCEPTABLE
887 -352.15 802.87 846.22 45.81 ACCEPTABLE
888 -352.98 807.68 850.96 45.80 ACCEPTABLE
889 -352.11 802.87 846.22 45.33 ACCEPTABLE
890 -1.37 42.05 14.07 2.09 ACCEPTABLE

42
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name : Stability Analysis Stage - analysis : 1 - 1


Description : Stability Analysis

[3

[3

[3
7

3
34.20
33.00

30.00

27.00

24.00

21.00

4
18.00
40.00]
40.00]

15.00
[12.55;
[11.80;

6
62

12.00
[6.76; 34.00]

9.00
5
1

29.60]
29.60]
[2.23; 28.60]

6.00
29.60]
[3.07;
[2.23;
40.00]

2
[0.00;40.00]

[-5.50; 29.60] [-0.60; 29.60]


[1.73;
23 2 4

3.00
[-1.37; 42.05]

31
2
56
[-0.60;

2
415

0.00
3

3
1

[-5.50; 28.60]

-3.00
[-7.92; 29.60]
3
2
1
2

-6.00
1

-9.00

-12.00

-15.00
4
5

-18.00

-21.00
[-28.50; 29.60]
[-28.50; 28.60]

-24.00

-27.00
1
1

-28.50

43
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Input data (Stage of construction 2)


Geological profile and assigned soils
Position information
Terrain elevation = 40.00 m
Geological profile and assigned soils
Thickness of layer Depth Altitude
No. Assigned soil Pattern
t [m] z [m] [m]

1 6.00 0.00 .. 6.00 40.00 .. 34.00 Existing

2 - 6.00 ..  34.00 .. - LIMESTONE

Foundation
Type of foundation : input parameters of contact base-soil
Parameters
Friction coefficient base-soil  = 0.50
Cohesion base-soil a = 100.00 kPa
Terrain profile
Terrain behind the structure is flat.

Water influence
GWT behind the structure lies at a depth of 10.40 m
GWT in front of the structure lies at a depth of 10.40 m
Subgrade at the heel is permeable.
Hydraulic gradient = 0.00
The evolution of tensile cracks is considered in the analyses. Depth of cracks is 0.10 m.

Input surface surcharges


Surcharge Mag.1 Mag.2 Ord.x Length Depth
No. Action
new change [kN/m2] [kN/m2] x [m] l [m] z [m]
1 Yes permanent 20.00 on terrain
No. Name
1 Surcharge Load 20kPa
Resistance on front face of the structure
Resistance on front face of the structure: passive
Soil on front face of the structure - Earth Fill
Angle of friction struc.-soil  = 46.00 °
Soil thickness in front of structure h = 1.00 m
Terrain in front of structure is flat.

Settings of the stage of construction


Design situation : permanent
The wall is free to move. Active earth pressure is therefore assumed.

Verification No. 1 (Stage of construction 2)


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079

44
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11

45
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] overtur. sliding stress
Weight - wall 0.00 -4.11 474.35 5.30 1.000 1.000 1.350
FF resistance -56.26 -0.46 -58.26 0.00 1.000 1.000 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000 1.000 1.350
Active pressure 235.60 -2.98 101.73 7.73 1.350 1.350 1.350
Water pressure 0.00 -11.40 0.00 7.73 1.000 1.000 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350 1.350 1.350
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.350 1.350 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000 1.000 1.350
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 4284.14 kNm/m
Overturning moment Movr = 1320.16 kNm/m
Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 1111.62 kN/m
Active horizontal force Hact = 345.43 kN/m
Wall for slip is SATISFACTORY

Overall check - WALL is SATISFACTORY

Maximum stress in footing bottom : 148.67 kPa

Bearing capacity of foundation soil (Stage of construction 2)


Design load acting at the center of footing bottom
Moment Norm. force Shear Force Eccentricity Stress
No.
[kNm/m] [kN/m] [kN/m] [–] [kPa]
1 -1846.86 1149.71 325.74 0.000 148.67
2 -1201.86 898.91 345.43 0.000 116.24
Service load acting at the center of footing bottom
Moment Norm. force Shear Force
No.
[kNm/m] [kN/m] [kN/m]
1 -1368.04 851.64 241.29
Dimensioning No. 1 (Stage of construction 2)
Wall stem check - front vertical reinf.
Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079

46
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11

47
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - front vertical reinf. - MEd
Wall check at the construction joint 5.20 m from the wall crest
Hi = 59.28 kPa
MEd = 0.03 * Hi * H1 * l / 4 * b = 0.03 * 59.28 * 10.40 * 4.00 / 4 * 1.00 = 18.50 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.57 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 0.86 m = xmax
Ultimate moment MRd = 4716.61 kNm > 18.50 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - front vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 52.20 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93

48
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure behind the structure - partial results


Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000

49
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - back vertical reinf. - MEd
Wall check at the construction joint 10.40 m from the wall crest
Hi = 59.28 kPa
MEd = 0.03 * Hi * H1 * l * b = 0.03 * 59.28 * 10.40 * 4.00 * 1.00 = 73.95 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 2.33 m
Reinforcement ratio  = 0.35 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 1.40 m = xmax
Ultimate moment MRd = 7746.39 kNm > 73.95 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 52.20 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - front horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355

50
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Layer Thickness  d cd  d Ka Comment


No. [m] [°] [°] [kPa] [kN/m3] [°]
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000

51
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - front horizontal reinf.
pi = 26.10 kPa
MEd = 1 / 20 * pi * l2 = 1 / 20 * 26.10 * 4.002 = 217.16 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.17 % > 0.17 % = min
Position of neutral axis x = 0.06 m < 0.87 m = xmax
Ultimate shear force VRd = 4887.88 kN > 542.89 kN = VEd
Ultimate moment MRd = 15328.55 kNm > 217.16 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - back horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02

52
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Water pressure distribution


Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -56.26 -0.46 -58.26 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 235.60 -2.98 101.73 7.73 1.000
Water pressure 0.00 -11.40 0.00 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - back horizontal reinf.
pi = 26.10 kPa
MEd = 1 / 12 * pi * l2 = 1 / 12 * 26.10 * 4.002 = 361.93 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.17 % > 0.17 % = min
Position of neutral axis x = 0.06 m < 0.87 m = xmax
Ultimate shear force VRd = 4887.88 kN > 542.89 kN = VEd
Ultimate moment MRd = 15328.55 kNm > 361.93 kNm = MEd
Cross-section is SATISFACTORY.

53
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Wall jump check - bottom reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00

54
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Pressure profile due to surcharge - Surcharge Load 20kPa


Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -56.26 -0.46 -58.26 0.00 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.350
Active pressure 235.60 -2.98 101.73 7.73 1.350
Water pressure 0.00 -11.40 0.00 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.350
Wall jump check - bottom reinf.
j1 = 148.67 kPa
MEd = 1 / 12 * j1 * l2 = 1 / 12 * 148.67 * 4.002 = 971.31 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate shear force VRd = 1676.48 kN > 1456.96 kN = VEd
Ultimate moment MRd = 3212.47 kNm > 971.31 kNm = MEd
Cross-section is SATISFACTORY.

Wall jump check - top reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 10.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 10.00 0.00 101.39 70.43 -72.93

55
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure behind the structure - partial results


Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 10.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 0.00 0.00 0.00 0.00
2.41 43.36 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 22.95 20.80 9.70
6.00 108.00 0.00 22.95 20.80 9.70
3
10.40 187.20 0.00 51.07 46.29 21.58
10.40 187.20 0.00 51.18 48.94 14.96
4
11.40 197.20 0.00 54.78 52.39 16.02
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00
5 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -56.26 -0.46 -58.26 0.00 1.350

56
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.350
Active pressure 235.60 -2.98 101.73 7.73 1.350
Water pressure 0.00 -11.40 0.00 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.350
Wall jump check - top reinf.
j1 = 148.67 kPa
MEd = 1 / 20 * j1 * l2 = 1 / 20 * 148.67 * 4.002 = 582.79 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate shear force VRd = 1676.48 kN > 1456.96 kN = VEd
Ultimate moment MRd = 3212.47 kNm > 582.79 kNm = MEd
Cross-section is SATISFACTORY.

Buttress check
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.95 9.46 25.00 15.00 18.00 17.00 0.435
2 4.05 9.46 25.00 15.00 18.00 17.00 0.435
3 4.40 9.46 25.00 15.00 18.00 17.00 0.435
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
1.95 35.10 0.00 0.00 0.00 0.00
1.95 35.10 0.00 0.00 0.00 0.00
2
6.00 108.00 0.00 31.68 28.36 14.12
6.00 108.00 0.00 31.68 28.36 14.12
3
10.40 187.18 0.00 66.09 59.17 29.45
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 1.95 0.00 0.00
3 6.00 0.00 0.00
4 10.40 0.00 0.00

57
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Pressure profile due to surcharge - Tensile crack


Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 7.78 3.87
2 1.95 7.78 3.87
3 6.00 7.78 3.87
4 10.40 7.78 3.87
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] moment norm.force shear for.
Weight - wall 0.00 -4.18 366.01 0.82 1.350 1.350 1.000
Active pressure 249.95 -2.82 124.41 1.86 1.350 1.350 1.350
Water pressure 0.00 -10.40 0.00 0.60 1.000 1.000 1.000
Tensile crack 0.05 -10.33 0.00 0.60 1.350 1.000 1.350
Surcharge Load 20kPa 70.07 -4.51 40.28 1.47 1.350 1.350 1.350
Buttress check
Wall check at the construction joint 10.40 m from the wall crest
Shear reinf. - 2 profile 16.0 mm; distance 200.0 mm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 0.60 m
Cross-section height = 7.23 m
Reinforcement ratio  = 0.19 % > 0.17 % = min
Position of neutral axis x = 0.31 m < 4.42 m = xmax
Ultimate shear force VRd = 14096.07 kN > 1987.60 kN = VEd
Ultimate moment MRd = 24623.00 kNm > 6513.01 kNm = MEd
Cross-section is SATISFACTORY.

Slope stability analysis


Input data
Project
Settings
(input for current task)
Stability analysis
Earthquake analysis : Standard
Verification methodology : Safety factors (ASD)
Safety factors
Permanent design situation
Safety factor : SFs = 1.50 [–]

58
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Interface
Coordinates of interface points [m]
No. Interface location
x z x z x z
1 -28.50 29.60 -5.50 29.60 -0.60 29.60
-0.60 40.00 0.00 40.00 11.80 40.00
34.20 40.00

2 0.00 40.00 1.73 29.60 2.23 29.60

3 -5.50 28.60 2.23 28.60 2.23 29.60


3.07 29.60 6.76 34.00 11.80 40.00

4 6.76 34.00 34.20 34.00

5 -28.50 28.60 -5.50 28.60 -5.50 29.60

6 2.23 28.60 3.07 29.60

Soil parameters - effective stress state


ef cef 
No. Name Pattern
[°] [kPa] [kN/m3]

1 Earth Fill 25.00 15.00 18.00

2 Existing 30.00 15.00 18.00

Soil parameters - uplift


sat s n
No. Name Pattern
[kN/m3] [kN/m3] [–]

1 Earth Fill 20.00

2 Existing 19.00

59
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Soil parameters - total stress state


cu 
No. Name Pattern
[kPa] [kN/m3]

1 LIMESTONE 100.00 24.00

2 Concrete 500.00 24.00

Soil parameters
Earth Fill
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 25.00 °
Cohesion of soil : cef = 15.00 kPa
Saturated unit weight : sat = 20.00 kN/m3

LIMESTONE
Unit weight :  = 24.00 kN/m3
Stress-state : total
Cohesion of soil : cu = 100.00 kPa

Concrete
Unit weight :  = 24.00 kN/m3
Stress-state : total
Cohesion of soil : cu = 500.00 kPa

Existing
Unit weight :  = 18.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 30.00 °
Cohesion of soil : cef = 15.00 kPa
Saturated unit weight : sat = 19.00 kN/m3

Rigid bodies

No. Name Sample
[kN/m3]

1 Wall material 24.00

Assigning and surfaces


Coordinates of surface points [m] Assigned
No. Surface position
x z x z soil
1 34.20 34.00 34.20 40.00
Existing
11.80 40.00 6.76 34.00

60
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Coordinates of surface points [m] Assigned


No. Surface position
x z x z soil
2 3.07 29.60 6.76 34.00
Earth Fill
11.80 40.00 0.00 40.00
1.73 29.60 2.23 29.60

3 -5.50 28.60 2.23 28.60


Wall material
2.23 29.60 1.73 29.60
0.00 40.00 -0.60 40.00
-0.60 29.60 -5.50 29.60

4 -5.50 28.60 -5.50 29.60


Earth Fill
-28.50 29.60 -28.50 28.60

5 3.07 29.60 2.23 29.60


Earth Fill
2.23 28.60

6 2.23 28.60 -5.50 28.60


LIMESTONE
-28.50 28.60 -28.50 23.60
34.20 23.60 34.20 34.00
6.76 34.00 3.07 29.60

Surcharge
Location Origin Length Width Slope Magnitude
No. Type Type of action
z [m] x [m] l [m] b [m]  [°] q, q1, f, F q2 unit
1 strip permanent on terrain x = 0.00 l = 34.20 0.00 20.00 kN/m2
Surcharges

No. Name

1 Surcharge Load 20kPa


Water
Water type : GWT
Coordinates of GWT points [m]
No. GWT location
x z x z x z
-28.50 29.60 1.73 29.60 34.20 29.60

Tensile crack
Tensile crack not input.
Earthquake
Earthquake not included.

61
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Settings of the stage of construction


Design situation : permanent
Results (Stage of construction 1)
Analysis 1
Circular slip surface
Slip surface parameters
x= -1.64 [m] 1 = -26.26 [°]
Center : Angles :
z= 42.81 [m] 2 = 79.00 [°]
Radius : R= 14.73 [m]
The slip surface after optimization.
Slope stability verification (Bishop)
Sum of active forces : Fa = 1098.34 kN/m
Sum of passive forces : Fp = 2039.85 kN/m
Sliding moment : Ma = 16178.61 kNm/m
Resisting moment : Mp = 30047.06 kNm/m
Factor of safety = 1.86 > 1.50
Slope stability ACCEPTABLE
Optimization of circular slip surface (Bishop)
Center Radius
No. FS Verification
x [m] z [m] R [m]
1 -0.59 40.10 15.69 2.11 ACCEPTABLE
2 -0.59 40.10 15.69 2.11 ACCEPTABLE
3 -0.59 40.10 15.69 2.11 ACCEPTABLE
4 13.89 69.66 32.66 417911058.12 ACCEPTABLE
5 -4.32 63.69 39.72 2.46 ACCEPTABLE
6 -2.09 52.44 32.15 2.23 ACCEPTABLE
7 -13.05 40.10 15.69 77.14 ACCEPTABLE
8 -4.44 64.27 40.16 2.48 ACCEPTABLE
9 -0.59 40.10 15.69 2.11 ACCEPTABLE
10 -29.24 164.42 135.10 31.15 ACCEPTABLE
11 -10.73 88.61 59.40 23.73 ACCEPTABLE
12 -3.36 55.05 30.71 2.30 ACCEPTABLE
13 -1.82 48.54 26.64 2.18 ACCEPTABLE
14 7.72 40.10 15.69 17.95 ACCEPTABLE
15 -12.13 48.61 20.79 38.15 ACCEPTABLE
16 -11.48 48.12 19.99 38.11 ACCEPTABLE
17 -8.90 40.10 15.69 10.69 ACCEPTABLE
18 -3.24 54.53 30.35 2.28 ACCEPTABLE
19 -324.09 623.19 670.51 65.31 ACCEPTABLE
20 -315.78 623.19 670.51 29.33 ACCEPTABLE
21 -0.59 40.10 15.69 2.11 ACCEPTABLE
22 -9.29 74.38 45.58 68.08 ACCEPTABLE
23 -0.76 55.10 26.19 68.85 ACCEPTABLE
24 -2.59 49.65 25.16 2.19 ACCEPTABLE
25 -1.57 45.86 22.97 2.14 ACCEPTABLE
26 4.95 40.10 15.69 2.46 ACCEPTABLE
27 -8.60 46.59 19.32 41.24 ACCEPTABLE
28 -3.38 42.31 13.14 88.04 ACCEPTABLE
29 -6.13 40.10 15.69 2.54 ACCEPTABLE
30 -2.41 48.98 24.73 2.17 ACCEPTABLE
31 -349.33 764.58 808.59 51.59 ACCEPTABLE
32 -466.07 1521.83 1559.71 33.67 ACCEPTABLE

62
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
33 -343.79 764.58 808.59 32.17 ACCEPTABLE
34 -0.59 40.10 15.69 2.11 ACCEPTABLE
35 -5.08 56.53 29.04 2.36 ACCEPTABLE
36 0.17 47.81 20.19 1.99 ACCEPTABLE
37 2.92 50.28 22.10 33.37 ACCEPTABLE
38 -0.57 45.72 16.68 72.03 ACCEPTABLE
39 -11.58 90.54 60.94 25.14 ACCEPTABLE
40 -4.81 70.60 41.00 23.23 ACCEPTABLE
41 -2.34 59.69 31.68 2.24 ACCEPTABLE
42 6.77 40.17 15.71 17.92 ACCEPTABLE
43 -0.19 52.51 25.89 2.17 ACCEPTABLE
44 3.86 47.81 20.19 25.95 ACCEPTABLE
45 1.86 45.68 21.39 2.14 ACCEPTABLE
46 1.20 42.33 14.09 31.84 ACCEPTABLE
47 -7.11 57.25 28.12 25.40 ACCEPTABLE
48 -5.62 55.40 25.81 25.33 ACCEPTABLE
49 -3.52 47.81 20.19 2.10 ACCEPTABLE
50 -0.93 41.00 16.06 2.08 ACCEPTABLE
51 -2.32 44.66 18.03 2.06 ACCEPTABLE
52 1.80 41.16 13.34 25.65 ACCEPTABLE
53 -1.39 56.54 29.04 2.22 ACCEPTABLE
54 3.02 50.03 21.90 32.26 ACCEPTABLE
55 -367.37 869.49 911.88 45.68 ACCEPTABLE
56 -445.53 1374.32 1412.80 36.82 ACCEPTABLE
57 -363.68 869.49 911.88 34.78 ACCEPTABLE
58 0.17 47.81 20.19 1.99 ACCEPTABLE
59 1.64 50.42 22.21 28.53 ACCEPTABLE
60 -0.62 47.17 18.40 73.36 ACCEPTABLE
61 -5.50 67.75 38.55 68.44 ACCEPTABLE
62 -1.56 58.81 29.56 70.94 ACCEPTABLE
63 -1.53 55.43 27.51 2.14 ACCEPTABLE
64 4.61 42.61 16.84 11.39 ACCEPTABLE
65 -0.10 50.98 24.00 2.12 ACCEPTABLE
66 2.63 47.81 20.19 19.23 ACCEPTABLE
67 1.44 46.20 20.75 2.11 ACCEPTABLE
68 0.69 44.35 16.23 23.99 ACCEPTABLE
69 -4.55 53.75 25.00 69.32 ACCEPTABLE
70 -2.56 51.35 22.04 71.68 ACCEPTABLE
71 -2.29 47.81 20.19 2.03 ACCEPTABLE
72 -0.65 43.49 17.33 2.03 ACCEPTABLE
73 2.00 41.52 14.40 14.30 ACCEPTABLE
74 0.25 41.14 16.12 2.09 ACCEPTABLE
75 -1.52 45.78 18.76 2.02 ACCEPTABLE
76 1.25 43.15 15.40 19.35 ACCEPTABLE
77 -0.88 53.40 25.87 2.14 ACCEPTABLE
78 2.01 49.44 21.43 24.39 ACCEPTABLE
79 -376.01 943.51 985.02 33.83 ACCEPTABLE
80 -373.55 943.51 985.02 29.33 ACCEPTABLE
81 0.17 47.81 20.19 1.99 ACCEPTABLE
82 1.03 49.85 21.75 18.80 ACCEPTABLE
83 -0.44 47.65 19.18 31.93 ACCEPTABLE
84 -3.06 58.89 30.14 67.46 ACCEPTABLE
85 -0.57 54.06 25.27 69.00 ACCEPTABLE

63
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
86 -0.98 52.75 24.92 2.09 ACCEPTABLE
87 3.15 44.29 17.80 4.60 ACCEPTABLE
88 -0.02 49.94 22.74 2.09 ACCEPTABLE
89 1.81 47.81 20.19 11.85 ACCEPTABLE
90 1.10 46.63 20.43 2.09 ACCEPTABLE
91 0.47 45.56 17.58 14.79 ACCEPTABLE
92 -2.93 51.65 23.21 24.58 ACCEPTABLE
93 -1.36 49.78 20.93 71.52 ACCEPTABLE
94 -1.47 47.81 20.19 2.00 ACCEPTABLE
95 1.36 42.07 15.93 2.06 ACCEPTABLE
96 2.37 41.16 14.82 2.12 ACCEPTABLE
97 -0.42 45.04 18.27 2.01 ACCEPTABLE
98 1.38 43.46 16.15 7.24 ACCEPTABLE
99 0.38 42.95 17.03 2.04 ACCEPTABLE
100 -0.97 46.49 19.25 2.00 ACCEPTABLE
101 0.88 44.60 16.90 11.22 ACCEPTABLE
102 -0.53 51.43 23.87 2.08 ACCEPTABLE
103 1.38 48.95 21.05 16.00 ACCEPTABLE
104 0.17 47.81 20.19 1.99 ACCEPTABLE
105 0.70 49.28 21.31 12.42 ACCEPTABLE
106 -0.26 47.81 19.58 15.13 ACCEPTABLE
107 -1.80 54.46 26.06 13.90 ACCEPTABLE
108 -0.18 51.61 23.18 24.17 ACCEPTABLE
109 -0.60 51.04 23.27 2.05 ACCEPTABLE
110 2.17 45.44 18.53 2.08 ACCEPTABLE
111 0.03 49.24 21.89 2.06 ACCEPTABLE
112 1.26 47.81 20.19 8.02 ACCEPTABLE
113 0.83 46.97 20.28 2.06 ACCEPTABLE
114 0.35 46.33 18.46 9.62 ACCEPTABLE
115 -1.88 50.32 22.13 1.98 ACCEPTABLE
116 -1.59 52.43 23.87 48.19 ACCEPTABLE
117 -2.45 50.47 21.74 70.92 ACCEPTABLE
118 -4.30 58.44 29.55 68.53 ACCEPTABLE
119 -2.62 55.14 26.22 69.70 ACCEPTABLE
120 -2.80 54.18 25.83 15.58 ACCEPTABLE
121 0.27 47.53 19.99 2.00 ACCEPTABLE
122 -1.95 51.77 23.85 2.06 ACCEPTABLE
123 -0.79 50.32 22.13 6.17 ACCEPTABLE
124 -1.02 49.11 21.80 2.05 ACCEPTABLE
125 -1.78 48.84 20.40 28.55 ACCEPTABLE
126 -4.14 53.38 24.68 71.94 ACCEPTABLE
127 -3.13 52.10 23.14 73.19 ACCEPTABLE
128 -2.97 50.32 22.13 11.41 ACCEPTABLE
129 -0.74 45.44 18.17 1.99 ACCEPTABLE
130 -0.10 44.77 17.37 1.97 ACCEPTABLE
131 0.54 45.87 18.14 6.61 ACCEPTABLE
132 -0.43 44.64 16.60 9.29 ACCEPTABLE
133 -1.88 50.32 22.13 1.98 ACCEPTABLE
134 -0.28 47.84 19.61 15.13 ACCEPTABLE
135 -0.82 47.53 19.99 2.00 ACCEPTABLE
136 1.82 42.76 16.11 2.06 ACCEPTABLE
137 -0.27 46.08 18.97 2.01 ACCEPTABLE
138 0.99 44.77 17.37 3.15 ACCEPTABLE

64
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
139 0.45 44.18 17.74 2.04 ACCEPTABLE
140 0.13 43.39 15.75 4.19 ACCEPTABLE
141 -2.04 46.81 18.82 1.95 ACCEPTABLE
142 -1.61 48.43 20.07 17.27 ACCEPTABLE
143 -2.48 46.73 18.18 52.71 ACCEPTABLE
144 -4.17 53.47 24.76 72.08 ACCEPTABLE
145 -2.52 50.62 21.87 71.75 ACCEPTABLE
146 -2.89 50.08 21.94 7.81 ACCEPTABLE
147 0.01 44.51 17.19 1.97 ACCEPTABLE
148 -2.15 48.15 20.44 2.03 ACCEPTABLE
149 -0.95 46.81 18.82 1.93 ACCEPTABLE
150 -0.52 48.43 20.07 18.34 ACCEPTABLE
151 -1.39 46.73 18.18 51.91 ACCEPTABLE
152 -3.08 53.47 24.76 69.90 ACCEPTABLE
153 -1.43 50.62 21.87 69.58 ACCEPTABLE
154 -1.80 50.08 21.94 1.98 ACCEPTABLE
155 1.10 44.51 17.19 3.06 ACCEPTABLE
156 -1.06 48.15 20.44 2.00 ACCEPTABLE
157 0.14 46.81 18.82 10.32 ACCEPTABLE
158 -0.23 45.97 18.89 2.01 ACCEPTABLE
159 -0.80 45.43 17.18 13.69 ACCEPTABLE
160 -3.04 49.21 20.70 40.05 ACCEPTABLE
161 -1.97 48.02 19.22 72.74 ACCEPTABLE
162 -2.04 46.81 18.82 1.95 ACCEPTABLE
163 0.02 42.77 15.73 1.98 ACCEPTABLE
164 0.68 42.16 14.98 1.97 ACCEPTABLE
165 -1.27 44.93 17.48 1.96 ACCEPTABLE
166 -0.08 43.84 16.05 6.18 ACCEPTABLE
167 -0.62 43.37 16.47 1.98 ACCEPTABLE
168 -1.67 45.90 18.15 1.96 ACCEPTABLE
169 -0.45 44.67 16.62 9.86 ACCEPTABLE
170 -1.44 49.15 21.20 1.99 ACCEPTABLE
171 -0.21 47.66 19.47 13.36 ACCEPTABLE
172 -390.16 1030.89 1071.54 33.07 ACCEPTABLE
173 -389.06 1030.89 1071.54 30.20 ACCEPTABLE
174 -0.95 46.81 18.82 1.93 ACCEPTABLE
175 -0.68 47.92 19.67 11.86 ACCEPTABLE
176 -1.25 46.80 18.42 20.98 ACCEPTABLE
177 -2.30 50.95 22.47 29.32 ACCEPTABLE
178 -1.21 49.21 20.70 37.98 ACCEPTABLE
179 -1.52 48.96 20.86 1.96 ACCEPTABLE
180 0.42 45.27 17.71 1.96 ACCEPTABLE
181 -1.03 47.70 19.90 1.98 ACCEPTABLE
182 -0.22 46.81 18.82 7.01 ACCEPTABLE
183 -0.45 46.22 18.83 1.99 ACCEPTABLE
184 -0.85 45.89 17.73 8.38 ACCEPTABLE
185 -2.34 48.40 20.05 16.30 ACCEPTABLE
186 -1.58 47.56 19.02 46.73 ACCEPTABLE
187 -1.68 46.81 18.82 1.94 ACCEPTABLE
188 -0.25 43.97 16.60 1.95 ACCEPTABLE
189 0.18 43.55 16.09 1.94 ACCEPTABLE
190 -1.17 45.58 17.93 1.95 ACCEPTABLE
191 -0.37 44.80 16.93 4.04 ACCEPTABLE

65
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
192 -0.68 44.39 17.11 1.97 ACCEPTABLE
193 -1.43 46.21 18.38 1.95 ACCEPTABLE
194 -0.62 45.36 17.33 6.18 ACCEPTABLE
195 -1.28 48.35 20.39 1.97 ACCEPTABLE
196 -0.46 47.38 19.25 9.64 ACCEPTABLE
197 -0.95 46.81 18.82 1.93 ACCEPTABLE
198 -0.78 47.57 19.40 7.96 ACCEPTABLE
199 -1.16 46.82 18.56 9.59 ACCEPTABLE
200 -1.82 49.45 21.13 9.61 ACCEPTABLE
201 -1.10 48.35 20.01 12.95 ACCEPTABLE
202 -1.33 48.23 20.17 1.95 ACCEPTABLE
203 -0.04 45.78 18.07 1.94 ACCEPTABLE
204 -1.00 47.41 19.54 1.96 ACCEPTABLE
205 -0.46 46.81 18.82 5.21 ACCEPTABLE
206 -0.60 46.40 18.81 1.98 ACCEPTABLE
207 -0.89 46.20 18.09 6.84 ACCEPTABLE
208 -1.87 47.86 19.63 5.21 ACCEPTABLE
209 -1.36 47.29 18.92 19.17 ACCEPTABLE
210 -1.44 46.81 18.82 1.93 ACCEPTABLE
211 -0.46 44.84 17.26 1.94 ACCEPTABLE
212 -0.18 44.56 16.91 1.94 ACCEPTABLE
213 -1.10 46.00 18.23 1.95 ACCEPTABLE
214 -0.57 45.45 17.54 2.89 ACCEPTABLE
215 -0.74 45.13 17.61 1.96 ACCEPTABLE
216 -1.27 46.41 18.52 1.94 ACCEPTABLE
217 -0.73 45.83 17.82 5.15 ACCEPTABLE
218 -1.17 47.82 19.86 1.95 ACCEPTABLE
219 -0.62 47.20 19.11 7.43 ACCEPTABLE
220 -0.95 46.81 18.82 1.93 ACCEPTABLE
221 -0.84 47.32 19.21 5.23 ACCEPTABLE
222 -1.09 46.83 18.65 6.89 ACCEPTABLE
223 -1.52 48.52 20.31 3.07 ACCEPTABLE
224 -1.04 47.81 19.58 8.63 ACCEPTABLE
225 -1.20 47.75 19.71 1.94 ACCEPTABLE
226 -0.34 46.12 18.31 1.94 ACCEPTABLE
227 -0.99 47.21 19.30 1.95 ACCEPTABLE
228 -0.63 46.81 18.82 3.92 ACCEPTABLE
229 -0.71 46.53 18.80 1.96 ACCEPTABLE
230 -0.91 46.41 18.34 5.18 ACCEPTABLE
231 -1.56 47.51 19.35 1.92 ACCEPTABLE
232 -1.47 48.08 19.79 10.23 ACCEPTABLE
233 -1.71 47.54 19.20 15.95 ACCEPTABLE
234 -2.16 49.32 20.94 18.75 ACCEPTABLE
235 -1.68 48.58 20.19 20.67 ACCEPTABLE
236 -1.83 48.50 20.29 4.17 ACCEPTABLE
237 -0.94 46.78 18.80 1.93 ACCEPTABLE
238 -1.59 47.91 19.83 1.94 ACCEPTABLE
239 -1.24 47.51 19.35 4.15 ACCEPTABLE
240 -1.30 47.20 19.29 1.95 ACCEPTABLE
241 -1.53 47.11 18.87 6.99 ACCEPTABLE
242 -2.19 48.25 19.93 12.77 ACCEPTABLE
243 -1.85 47.86 19.46 22.58 ACCEPTABLE
244 -1.88 47.51 19.35 1.92 ACCEPTABLE

66
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
245 -1.19 46.08 18.19 1.93 ACCEPTABLE
246 -1.01 45.89 17.95 1.91 ACCEPTABLE
247 -0.89 46.37 18.30 5.18 ACCEPTABLE
248 -1.14 45.89 17.77 4.86 ACCEPTABLE
249 -1.56 47.51 19.35 1.92 ACCEPTABLE
250 -1.09 46.83 18.65 6.89 ACCEPTABLE
251 -1.26 46.78 18.80 1.94 ACCEPTABLE
252 -0.41 45.24 17.48 1.93 ACCEPTABLE
253 -1.05 46.28 18.42 1.94 ACCEPTABLE
254 -0.69 45.89 17.95 3.00 ACCEPTABLE
255 -0.78 45.64 17.96 1.95 ACCEPTABLE
256 -0.97 45.50 17.47 3.86 ACCEPTABLE
257 -1.61 46.55 18.44 1.91 ACCEPTABLE
258 -1.51 47.08 18.84 6.29 ACCEPTABLE
259 -1.75 46.56 18.27 12.64 ACCEPTABLE
260 -2.19 48.26 19.93 13.95 ACCEPTABLE
261 -1.71 47.55 19.21 15.51 ACCEPTABLE
262 -1.87 47.49 19.34 1.92 ACCEPTABLE
263 -0.99 45.86 17.93 1.92 ACCEPTABLE
264 -1.64 46.94 18.91 1.94 ACCEPTABLE
265 -1.29 46.55 18.44 1.90 ACCEPTABLE
266 -1.19 47.08 18.84 8.55 ACCEPTABLE
267 -1.43 46.56 18.27 12.65 ACCEPTABLE
268 -1.87 48.26 19.93 13.66 ACCEPTABLE
269 -1.39 47.55 19.21 15.14 ACCEPTABLE
270 -1.55 47.49 19.34 1.91 ACCEPTABLE
271 -0.67 45.86 17.93 1.92 ACCEPTABLE
272 -1.32 46.94 18.91 1.93 ACCEPTABLE
273 -0.97 46.55 18.44 5.18 ACCEPTABLE
274 -1.04 46.27 18.42 1.94 ACCEPTABLE
275 -1.25 46.16 17.96 6.25 ACCEPTABLE
276 -1.91 47.24 18.97 9.33 ACCEPTABLE
277 -1.56 46.86 18.51 18.28 ACCEPTABLE
278 -1.61 46.55 18.44 1.91 ACCEPTABLE
279 -0.94 45.20 17.36 1.92 ACCEPTABLE
280 -0.76 45.01 17.13 1.91 ACCEPTABLE
281 -1.38 46.00 18.03 1.92 ACCEPTABLE
282 -1.03 45.63 17.58 3.87 ACCEPTABLE
283 -1.12 45.39 17.59 1.93 ACCEPTABLE
284 -1.50 46.28 18.24 1.92 ACCEPTABLE
285 -1.14 45.90 17.77 5.15 ACCEPTABLE
286 -1.44 47.22 19.13 1.93 ACCEPTABLE
287 -1.08 46.82 18.64 7.40 ACCEPTABLE
288 -375.62 941.04 982.57 33.85 ACCEPTABLE
289 -375.30 941.04 982.57 33.41 ACCEPTABLE
290 -1.29 46.55 18.44 1.90 ACCEPTABLE
291 -1.22 46.90 18.71 6.31 ACCEPTABLE
292 -1.38 46.56 18.33 6.89 ACCEPTABLE
293 -1.67 47.67 19.41 7.38 ACCEPTABLE
294 -1.35 47.21 18.94 9.00 ACCEPTABLE
295 -1.47 47.18 19.03 1.91 ACCEPTABLE
296 -0.88 46.09 18.10 1.92 ACCEPTABLE
297 -1.31 46.81 18.76 1.92 ACCEPTABLE

67
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
298 -1.07 46.55 18.44 4.89 ACCEPTABLE
299 -1.12 46.36 18.42 1.93 ACCEPTABLE
300 -1.27 46.29 18.12 6.26 ACCEPTABLE
301 -1.70 47.01 18.79 5.07 ACCEPTABLE
302 -1.47 46.76 18.48 11.65 ACCEPTABLE
303 -1.51 46.55 18.44 1.91 ACCEPTABLE
304 -1.05 45.64 17.70 1.91 ACCEPTABLE
305 -0.93 45.51 17.55 1.91 ACCEPTABLE
306 -1.35 46.19 18.17 1.91 ACCEPTABLE
307 -1.11 45.94 17.86 4.08 ACCEPTABLE
308 -1.17 45.76 17.86 1.93 ACCEPTABLE
309 -1.43 46.37 18.30 1.91 ACCEPTABLE
310 -1.19 46.11 17.99 4.08 ACCEPTABLE
311 -1.39 46.99 18.90 1.92 ACCEPTABLE
312 -1.15 46.73 18.57 5.20 ACCEPTABLE
313 -1.29 46.55 18.44 1.90 ACCEPTABLE
314 -1.25 46.79 18.62 4.91 ACCEPTABLE
315 -1.35 46.56 18.37 5.19 ACCEPTABLE
316 -1.54 47.29 19.08 3.03 ACCEPTABLE
317 -1.33 46.98 18.77 5.22 ACCEPTABLE
318 -1.41 46.97 18.83 1.91 ACCEPTABLE
319 -1.02 46.24 18.21 1.91 ACCEPTABLE
320 -1.30 46.72 18.65 1.91 ACCEPTABLE
321 -1.15 46.55 18.44 3.01 ACCEPTABLE
322 -1.18 46.42 18.42 1.92 ACCEPTABLE
323 -1.27 46.38 18.23 4.88 ACCEPTABLE
324 -1.56 46.86 18.67 3.02 ACCEPTABLE
325 -1.41 46.69 18.46 6.29 ACCEPTABLE
326 -1.43 46.55 18.44 1.90 ACCEPTABLE
327 -1.39 46.79 18.62 3.92 ACCEPTABLE
328 -1.49 46.56 18.37 4.11 ACCEPTABLE
329 -1.68 47.29 19.08 3.01 ACCEPTABLE
330 -1.47 46.98 18.77 4.12 ACCEPTABLE
331 -1.55 46.97 18.83 1.91 ACCEPTABLE
332 -1.16 46.24 18.21 1.91 ACCEPTABLE
333 -1.44 46.72 18.65 1.92 ACCEPTABLE
334 -1.29 46.55 18.44 1.90 ACCEPTABLE
335 -1.32 46.42 18.42 1.92 ACCEPTABLE
336 -1.41 46.38 18.23 2.90 ACCEPTABLE
337 -1.70 46.86 18.67 1.90 ACCEPTABLE
338 -1.66 47.11 18.86 8.12 ACCEPTABLE
339 -1.77 46.87 18.60 10.04 ACCEPTABLE
340 -1.96 47.62 19.33 9.55 ACCEPTABLE
341 -1.75 47.31 19.01 11.08 ACCEPTABLE
342 -1.82 47.29 19.07 4.09 ACCEPTABLE
343 -1.42 46.55 18.43 1.90 ACCEPTABLE
344 -1.71 47.03 18.88 1.91 ACCEPTABLE
345 -1.56 46.86 18.67 3.02 ACCEPTABLE
346 -1.58 46.72 18.65 1.92 ACCEPTABLE
347 -1.69 46.69 18.46 6.23 ACCEPTABLE
348 -1.98 47.17 18.91 8.44 ACCEPTABLE
349 -1.82 47.00 18.70 11.63 ACCEPTABLE
350 -1.84 46.86 18.67 3.00 ACCEPTABLE

68
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
351 -1.53 46.23 18.15 1.91 ACCEPTABLE
352 -1.45 46.14 18.05 1.90 ACCEPTABLE
353 -1.74 46.61 18.48 1.91 ACCEPTABLE
354 -1.58 46.44 18.27 1.90 ACCEPTABLE
355 -1.54 46.68 18.45 6.25 ACCEPTABLE
356 -1.64 46.45 18.20 9.00 ACCEPTABLE
357 -1.83 47.18 18.91 8.29 ACCEPTABLE
358 -1.62 46.88 18.60 11.13 ACCEPTABLE
359 -1.70 46.86 18.67 1.90 ACCEPTABLE
360 -1.31 46.14 18.04 2.90 ACCEPTABLE
361 -1.59 46.61 18.48 1.91 ACCEPTABLE
362 -1.44 46.44 18.27 3.90 ACCEPTABLE
363 -1.47 46.31 18.25 1.92 ACCEPTABLE
364 -1.57 46.27 18.06 5.14 ACCEPTABLE
365 -1.86 46.75 18.50 7.99 ACCEPTABLE
366 -1.70 46.58 18.30 11.15 ACCEPTABLE
367 -1.72 46.44 18.27 1.90 ACCEPTABLE
368 -1.41 45.82 17.77 1.90 ACCEPTABLE
369 -1.33 45.74 17.66 1.90 ACCEPTABLE
370 -1.62 46.19 18.09 1.91 ACCEPTABLE
371 -1.46 46.03 17.88 2.89 ACCEPTABLE
372 -1.49 45.91 17.87 1.91 ACCEPTABLE
373 -1.67 46.32 18.18 1.90 ACCEPTABLE
374 -1.51 46.15 17.97 4.08 ACCEPTABLE
375 -1.65 46.74 18.57 1.90 ACCEPTABLE
376 -1.49 46.56 18.36 4.10 ACCEPTABLE
377 -1.58 46.44 18.27 1.90 ACCEPTABLE
378 -1.55 46.60 18.39 4.11 ACCEPTABLE
379 -1.62 46.45 18.22 7.29 ACCEPTABLE
380 -1.75 46.93 18.69 6.83 ACCEPTABLE
381 -1.61 46.73 18.49 7.13 ACCEPTABLE
382 -1.66 46.72 18.53 1.90 ACCEPTABLE
383 -1.40 46.24 18.12 3.00 ACCEPTABLE
384 -1.59 46.55 18.41 1.90 ACCEPTABLE
385 -1.48 46.44 18.27 2.90 ACCEPTABLE
386 -1.50 46.35 18.26 1.91 ACCEPTABLE
387 -1.57 46.33 18.13 4.09 ACCEPTABLE
388 -1.76 46.64 18.42 6.22 ACCEPTABLE
389 -1.66 46.53 18.29 8.05 ACCEPTABLE
390 -1.68 46.44 18.27 1.90 ACCEPTABLE
391 -1.47 46.02 17.93 1.90 ACCEPTABLE
392 -1.42 45.97 17.86 1.90 ACCEPTABLE
393 -1.61 46.28 18.15 1.90 ACCEPTABLE
394 -1.50 46.16 18.01 2.90 ACCEPTABLE
395 -1.52 46.08 18.00 1.90 ACCEPTABLE
396 -1.64 46.36 18.21 1.90 ACCEPTABLE
397 -1.54 46.24 18.07 2.90 ACCEPTABLE
398 -1.62 46.64 18.47 1.90 ACCEPTABLE
399 -1.59 46.80 18.59 3.92 ACCEPTABLE
400 -1.66 46.65 18.42 6.22 ACCEPTABLE
401 -1.79 47.13 18.90 5.15 ACCEPTABLE
402 -1.65 46.93 18.69 6.85 ACCEPTABLE
403 -1.70 46.92 18.74 1.90 ACCEPTABLE

69
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
404 -1.44 46.43 18.31 1.90 ACCEPTABLE
405 -1.63 46.76 18.61 1.90 ACCEPTABLE
406 -1.52 46.64 18.47 2.91 ACCEPTABLE
407 -1.54 46.55 18.46 1.91 ACCEPTABLE
408 -1.61 46.52 18.33 2.91 ACCEPTABLE
409 -1.80 46.85 18.63 6.25 ACCEPTABLE
410 -1.70 46.73 18.49 7.00 ACCEPTABLE
411 -1.72 46.64 18.47 1.90 ACCEPTABLE
412 -1.51 46.22 18.13 1.90 ACCEPTABLE
413 -1.45 46.16 18.06 1.90 ACCEPTABLE
414 -1.65 46.48 18.35 1.90 ACCEPTABLE
415 -1.54 46.36 18.21 1.89 ACCEPTABLE
416 -1.51 46.52 18.33 3.90 ACCEPTABLE
417 -1.58 46.37 18.16 4.95 ACCEPTABLE
418 -1.71 46.85 18.63 5.15 ACCEPTABLE
419 -1.57 46.65 18.43 6.26 ACCEPTABLE
420 -1.62 46.64 18.47 1.90 ACCEPTABLE
421 -1.36 46.16 18.06 1.90 ACCEPTABLE
422 -1.55 46.47 18.35 1.90 ACCEPTABLE
423 -1.44 46.36 18.21 2.90 ACCEPTABLE
424 -1.46 46.27 18.20 1.91 ACCEPTABLE
425 -1.53 46.25 18.07 4.09 ACCEPTABLE
426 -1.72 46.56 18.36 4.07 ACCEPTABLE
427 -1.62 46.45 18.22 7.29 ACCEPTABLE
428 -1.64 46.36 18.21 1.90 ACCEPTABLE
429 -1.43 45.95 17.88 1.90 ACCEPTABLE
430 -1.38 45.89 17.81 1.90 ACCEPTABLE
431 -1.57 46.20 18.09 1.90 ACCEPTABLE
432 -1.46 46.09 17.95 2.90 ACCEPTABLE
433 -1.48 46.00 17.94 1.90 ACCEPTABLE
434 -1.60 46.28 18.15 1.90 ACCEPTABLE
435 -1.50 46.17 18.01 3.00 ACCEPTABLE
436 -1.58 46.56 18.41 1.90 ACCEPTABLE
437 -1.48 46.44 18.27 2.90 ACCEPTABLE
438 -368.11 895.18 937.25 35.02 ACCEPTABLE
439 -368.01 895.18 937.25 33.38 ACCEPTABLE
440 -1.54 46.36 18.21 1.89 ACCEPTABLE
441 -1.52 46.47 18.29 4.10 ACCEPTABLE
442 -1.57 46.36 18.18 2.91 ACCEPTABLE
443 -1.65 46.68 18.49 1.90 ACCEPTABLE
444 -1.56 46.55 18.35 4.07 ACCEPTABLE
445 -1.59 46.54 18.38 1.90 ACCEPTABLE
446 -1.42 46.23 18.11 1.90 ACCEPTABLE
447 -1.55 46.44 18.30 1.90 ACCEPTABLE
448 -1.48 46.36 18.21 1.89 ACCEPTABLE
449 -1.49 46.30 18.20 1.90 ACCEPTABLE
450 -1.53 46.28 18.12 2.90 ACCEPTABLE
451 -1.66 46.49 18.31 2.89 ACCEPTABLE
452 -1.59 46.42 18.22 3.00 ACCEPTABLE
453 -1.60 46.36 18.21 1.89 ACCEPTABLE
454 -1.47 46.08 17.99 1.90 ACCEPTABLE
455 -1.43 46.05 17.94 1.90 ACCEPTABLE
456 -1.56 46.25 18.13 1.90 ACCEPTABLE

70
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
457 -1.49 46.18 18.04 1.90 ACCEPTABLE
458 -1.50 46.12 18.03 1.90 ACCEPTABLE
459 -1.58 46.31 18.17 1.90 ACCEPTABLE
460 -1.51 46.23 18.08 1.89 ACCEPTABLE
461 -1.49 46.34 18.16 4.10 ACCEPTABLE
462 -1.54 46.23 18.05 2.90 ACCEPTABLE
463 -1.62 46.55 18.36 3.01 ACCEPTABLE
464 -1.53 46.42 18.22 4.10 ACCEPTABLE
465 -1.56 46.41 18.25 1.90 ACCEPTABLE
466 -1.39 46.10 17.98 3.00 ACCEPTABLE
467 -1.52 46.31 18.17 1.90 ACCEPTABLE
468 -1.45 46.23 18.08 3.00 ACCEPTABLE
469 -1.46 46.17 18.07 1.90 ACCEPTABLE
470 -1.50 46.15 17.99 3.00 ACCEPTABLE
471 -1.63 46.36 18.18 1.89 ACCEPTABLE
472 -1.56 46.29 18.09 4.09 ACCEPTABLE
473 -1.57 46.23 18.08 1.90 ACCEPTABLE
474 -1.44 45.96 17.86 1.90 ACCEPTABLE
475 -1.40 45.92 17.81 1.90 ACCEPTABLE
476 -1.53 46.12 18.00 1.90 ACCEPTABLE
477 -1.46 46.05 17.91 2.89 ACCEPTABLE
478 -1.47 45.99 17.90 1.90 ACCEPTABLE
479 -1.55 46.18 18.04 1.90 ACCEPTABLE
480 -1.48 46.10 17.95 3.00 ACCEPTABLE
481 -1.54 46.36 18.21 1.89 ACCEPTABLE
482 -1.47 46.28 18.12 2.90 ACCEPTABLE
483 -368.44 897.17 939.21 35.06 ACCEPTABLE
484 -368.37 897.17 939.21 33.46 ACCEPTABLE
485 -1.51 46.23 18.08 1.89 ACCEPTABLE
486 -1.50 46.30 18.13 4.09 ACCEPTABLE
487 -1.53 46.23 18.06 2.90 ACCEPTABLE
488 -1.58 46.44 18.26 1.90 ACCEPTABLE
489 -1.52 46.36 18.17 3.90 ACCEPTABLE
490 -1.54 46.35 18.20 1.89 ACCEPTABLE
491 -1.43 46.14 18.01 3.00 ACCEPTABLE
492 -1.51 46.28 18.14 1.90 ACCEPTABLE
493 -1.47 46.23 18.08 3.00 ACCEPTABLE
494 -1.48 46.19 18.08 1.91 ACCEPTABLE
495 -1.51 46.18 18.02 2.90 ACCEPTABLE
496 -1.59 46.32 18.15 3.00 ACCEPTABLE
497 -1.54 46.27 18.09 3.00 ACCEPTABLE
498 -1.55 46.23 18.08 1.90 ACCEPTABLE
499 -1.46 46.05 17.93 1.89 ACCEPTABLE
500 -1.44 46.02 17.90 1.90 ACCEPTABLE
501 -1.52 46.16 18.03 1.90 ACCEPTABLE
502 -1.47 46.11 17.97 1.89 ACCEPTABLE
503 -1.48 46.07 17.96 1.90 ACCEPTABLE
504 -1.54 46.19 18.05 1.90 ACCEPTABLE
505 -1.49 46.14 17.99 1.89 ACCEPTABLE
506 -1.53 46.32 18.17 1.90 ACCEPTABLE
507 -1.48 46.27 18.11 2.90 ACCEPTABLE
508 -367.41 891.41 933.52 35.05 ACCEPTABLE
509 -368.27 896.55 938.60 34.94 ACCEPTABLE

71
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
510 -367.37 891.41 933.52 34.99 ACCEPTABLE
511 -10.53 100.55 71.73 64.41 ACCEPTABLE
512 -1.95 60.14 36.03 2.36 ACCEPTABLE
513 8.67 51.29 27.73 2.63 ACCEPTABLE
514 1.10 45.30 33.33 2.26 ACCEPTABLE
515 4.57 56.42 33.70 2.37 ACCEPTABLE
516 1.55 42.60 32.56 2.33 ACCEPTABLE
517 1.77 41.29 32.26 2.38 ACCEPTABLE
518 -0.78 47.87 23.68 2.13 ACCEPTABLE
519 -2.10 64.42 43.58 2.38 ACCEPTABLE
520 11.68 47.85 23.67 18.82 ACCEPTABLE
521 1.10 45.29 33.32 2.26 ACCEPTABLE
522 -13.24 47.87 23.68 18.98 ACCEPTABLE
523 12.98 43.15 21.25 19.78 ACCEPTABLE
524 -0.78 47.87 23.68 2.13 ACCEPTABLE
525 -32.95 220.75 191.36 29.98 ACCEPTABLE
526 -14.45 126.91 97.55 23.70 ACCEPTABLE
527 -3.55 68.06 43.63 2.53 ACCEPTABLE
528 -1.83 59.14 37.02 2.32 ACCEPTABLE
529 7.53 47.87 23.68 2.58 ACCEPTABLE
530 0.74 45.78 29.69 2.21 ACCEPTABLE
531 -15.20 69.84 41.22 29.25 ACCEPTABLE
532 -13.34 67.17 38.02 28.73 ACCEPTABLE
533 -9.09 47.87 23.68 2.69 ACCEPTABLE
534 -7.66 42.75 21.09 2.52 ACCEPTABLE
535 -3.20 66.25 42.21 2.48 ACCEPTABLE
536 7.68 47.33 23.36 2.59 ACCEPTABLE
537 -427.81 1227.89 1267.13 48.69 ACCEPTABLE
538 -419.50 1227.89 1267.13 28.83 ACCEPTABLE
539 -0.78 47.87 23.68 2.13 ACCEPTABLE
540 5.57 44.96 22.09 2.36 ACCEPTABLE
541 -1.30 45.31 18.11 2.00 ACCEPTABLE
542 -30.08 153.24 124.46 30.36 ACCEPTABLE
543 -16.34 97.40 68.78 24.88 ACCEPTABLE
544 -4.51 61.28 33.65 2.42 ACCEPTABLE
545 -1.89 51.86 26.27 2.20 ACCEPTABLE
546 4.24 45.31 18.11 22.64 ACCEPTABLE
547 0.47 43.36 21.34 2.15 ACCEPTABLE
548 -11.45 56.98 27.73 31.55 ACCEPTABLE
549 -14.99 60.96 32.99 30.69 ACCEPTABLE
550 -6.84 45.31 18.11 24.99 ACCEPTABLE
551 -5.21 41.19 15.73 2.36 ACCEPTABLE
552 -3.52 57.70 30.69 2.33 ACCEPTABLE
553 3.62 46.86 19.20 25.58 ACCEPTABLE
554 -1.30 45.31 18.11 2.00 ACCEPTABLE
555 2.07 46.12 18.67 12.52 ACCEPTABLE
556 -1.75 43.18 14.42 80.43 ACCEPTABLE
557 -10.63 78.49 49.01 25.77 ACCEPTABLE
558 -4.33 62.32 32.80 23.60 ACCEPTABLE
559 -3.52 55.44 27.89 2.24 ACCEPTABLE
560 -1.76 49.75 23.57 2.14 ACCEPTABLE
561 2.39 45.31 18.11 11.61 ACCEPTABLE
562 0.08 43.78 19.99 2.10 ACCEPTABLE

72
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
563 -7.91 52.70 23.89 26.60 ACCEPTABLE
564 -5.56 50.12 20.55 27.50 ACCEPTABLE
565 -4.99 45.31 18.11 4.67 ACCEPTABLE
566 -3.97 42.73 16.52 2.17 ACCEPTABLE
567 -2.79 53.09 26.03 2.19 ACCEPTABLE
568 1.80 46.81 19.16 14.86 ACCEPTABLE
569 -355.31 810.18 853.42 40.87 ACCEPTABLE
570 -351.62 810.18 853.42 31.25 ACCEPTABLE
571 -1.30 45.31 18.11 2.00 ACCEPTABLE
572 0.53 46.92 19.24 3.18 ACCEPTABLE
573 -1.87 44.52 16.07 35.88 ACCEPTABLE
574 -6.06 61.58 32.68 68.54 ACCEPTABLE
575 -2.26 53.98 25.01 70.95 ACCEPTABLE
576 -2.81 51.82 24.35 2.15 ACCEPTABLE
577 2.96 40.75 15.53 2.21 ACCEPTABLE
578 -1.64 48.31 21.77 2.10 ACCEPTABLE
579 1.16 45.31 18.11 2.01 ACCEPTABLE
580 -0.26 44.16 19.20 2.08 ACCEPTABLE
581 -0.63 41.96 14.32 1.90 ACCEPTABLE
582 1.27 43.11 15.07 28.01 ACCEPTABLE
583 -0.98 40.88 12.11 86.15 ACCEPTABLE
584 -5.58 56.14 26.96 72.54 ACCEPTABLE
585 -1.71 49.26 20.00 72.95 ACCEPTABLE
586 -2.26 47.74 19.85 1.99 ACCEPTABLE
587 -0.97 44.48 17.57 2.01 ACCEPTABLE
588 1.83 41.96 14.32 24.27 ACCEPTABLE
589 0.36 41.11 15.70 2.07 ACCEPTABLE
590 -4.83 45.54 16.86 79.23 ACCEPTABLE
591 -2.82 43.79 14.43 82.98 ACCEPTABLE
592 -3.09 41.96 14.32 4.15 ACCEPTABLE
593 -2.38 40.50 13.48 2.02 ACCEPTABLE
594 -1.70 46.33 18.82 2.00 ACCEPTABLE
595 1.35 42.96 14.97 27.55 ACCEPTABLE
596 -367.49 881.70 923.93 39.27 ACCEPTABLE
597 -365.03 881.70 923.93 32.28 ACCEPTABLE
598 -0.63 41.96 14.32 1.90 ACCEPTABLE
599 0.44 43.13 15.08 20.65 ACCEPTABLE
600 -0.99 41.49 12.99 51.33 ACCEPTABLE
601 -3.51 49.89 21.16 73.14 ACCEPTABLE
602 -1.04 46.17 17.37 75.01 ACCEPTABLE
603 -1.74 45.69 17.86 1.95 ACCEPTABLE
604 -0.88 43.66 16.49 1.97 ACCEPTABLE
605 1.01 41.96 14.32 16.82 ACCEPTABLE
606 0.09 41.34 15.16 2.03 ACCEPTABLE
607 -0.19 40.09 12.10 19.02 ACCEPTABLE
608 -3.46 44.41 15.99 36.76 ACCEPTABLE
609 -1.85 42.99 14.08 84.07 ACCEPTABLE
610 -2.27 41.96 14.32 1.95 ACCEPTABLE
611 -1.82 41.02 13.77 1.97 ACCEPTABLE
612 -1.35 44.77 17.22 1.96 ACCEPTABLE
613 0.65 42.69 14.79 19.20 ACCEPTABLE
614 -326.13 658.80 705.12 37.71 ACCEPTABLE
615 -324.49 658.80 705.12 32.71 ACCEPTABLE

73
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
616 -0.63 41.96 14.32 1.90 ACCEPTABLE
617 0.02 42.88 14.91 14.44 ACCEPTABLE
618 -0.91 41.74 13.48 20.95 ACCEPTABLE
619 -2.41 46.73 18.34 24.64 ACCEPTABLE
620 -0.79 44.55 16.10 35.35 ACCEPTABLE
621 -1.38 44.39 16.62 1.93 ACCEPTABLE
622 1.30 40.23 13.35 5.17 ACCEPTABLE
623 -0.81 43.11 15.77 1.95 ACCEPTABLE
624 0.46 41.96 14.32 10.76 ACCEPTABLE
625 -0.11 41.52 14.84 1.99 ACCEPTABLE
626 -0.37 40.74 12.85 11.61 ACCEPTABLE
627 -2.53 43.61 15.42 14.31 ACCEPTABLE
628 -1.36 42.58 14.06 52.17 ACCEPTABLE
629 -1.72 41.96 14.32 1.92 ACCEPTABLE
630 -1.10 40.68 13.58 1.97 ACCEPTABLE
631 -1.43 41.35 13.96 1.94 ACCEPTABLE
632 -0.13 40.31 12.60 10.79 ACCEPTABLE
633 -1.11 43.79 16.21 1.93 ACCEPTABLE
634 0.21 42.48 14.65 12.55 ACCEPTABLE
635 -351.68 803.35 846.70 34.61 ACCEPTABLE
636 -0.63 41.96 14.32 1.90 ACCEPTABLE
637 -0.22 42.63 14.74 10.05 ACCEPTABLE
638 -0.83 41.86 13.78 12.06 ACCEPTABLE
639 -1.77 44.95 16.80 3.99 ACCEPTABLE
640 -0.70 43.60 15.41 14.09 ACCEPTABLE
641 -1.13 43.55 15.82 1.91 ACCEPTABLE
642 0.65 40.82 13.65 3.11 ACCEPTABLE
643 -0.76 42.73 15.29 1.93 ACCEPTABLE
644 0.10 41.96 14.32 7.56 ACCEPTABLE
645 -0.27 41.65 14.64 1.97 ACCEPTABLE
646 -0.47 41.16 13.34 8.01 ACCEPTABLE
647 -1.90 43.07 15.04 1.88 ACCEPTABLE
648 -1.59 43.94 15.65 17.26 ACCEPTABLE
649 -2.14 42.96 14.53 36.42 ACCEPTABLE
650 -3.16 46.41 17.91 41.27 ACCEPTABLE
651 -2.08 44.95 16.40 55.38 ACCEPTABLE
652 -2.46 44.86 16.73 9.34 ACCEPTABLE
653 -0.57 41.83 14.24 1.91 ACCEPTABLE
654 -2.00 43.84 16.02 1.93 ACCEPTABLE
655 -1.17 43.07 15.04 5.00 ACCEPTABLE
656 -1.46 42.67 15.25 1.95 ACCEPTABLE
657 -1.78 42.27 14.06 14.94 ACCEPTABLE
658 -3.22 44.29 15.90 31.09 ACCEPTABLE
659 -2.46 43.57 14.98 78.96 ACCEPTABLE
660 -2.63 43.07 15.04 9.09 ACCEPTABLE
661 -1.26 40.79 13.38 1.94 ACCEPTABLE
662 -0.82 40.43 12.92 1.92 ACCEPTABLE
663 -2.14 42.07 14.39 1.95 ACCEPTABLE
664 -1.33 41.41 13.50 1.88 ACCEPTABLE
665 -0.96 42.11 13.95 13.33 ACCEPTABLE
666 -1.53 41.29 12.97 26.99 ACCEPTABLE
667 -2.52 44.35 15.95 28.68 ACCEPTABLE
668 -1.44 43.03 14.59 37.04 ACCEPTABLE

74
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
669 -1.86 42.99 14.99 1.89 ACCEPTABLE
670 -0.02 40.30 12.85 3.98 ACCEPTABLE
671 -1.45 42.14 14.43 1.92 ACCEPTABLE
672 -0.60 41.41 13.50 8.73 ACCEPTABLE
673 -0.94 41.10 13.81 1.95 ACCEPTABLE
674 -1.18 40.65 12.56 10.32 ACCEPTABLE
675 -2.61 42.47 14.20 21.35 ACCEPTABLE
676 -1.82 41.80 13.31 48.49 ACCEPTABLE
677 -2.06 41.41 13.50 2.93 ACCEPTABLE
678 -1.62 40.57 13.00 1.94 ACCEPTABLE
679 -1.85 41.00 13.25 1.92 ACCEPTABLE
680 -0.99 40.32 12.36 9.69 ACCEPTABLE
681 -1.66 42.58 14.72 1.90 ACCEPTABLE
682 -0.79 41.78 13.73 11.51 ACCEPTABLE
683 -334.40 704.91 750.11 36.13 ACCEPTABLE
684 -333.67 704.91 750.11 34.81 ACCEPTABLE
685 -1.33 41.41 13.50 1.88 ACCEPTABLE
686 -1.10 41.89 13.81 8.94 ACCEPTABLE
687 -1.47 41.35 13.15 15.72 ACCEPTABLE
688 -2.10 43.29 15.05 14.07 ACCEPTABLE
689 -1.39 42.46 14.18 18.85 ACCEPTABLE
690 -1.69 42.45 14.48 1.88 ACCEPTABLE
691 -0.46 40.67 13.06 3.05 ACCEPTABLE
692 -1.41 41.90 14.12 1.90 ACCEPTABLE
693 -0.84 41.41 13.50 5.87 ACCEPTABLE
694 -1.06 41.19 13.70 1.93 ACCEPTABLE
695 -1.23 40.91 12.87 7.43 ACCEPTABLE
696 -2.19 42.12 13.96 12.00 ACCEPTABLE
697 -1.64 41.66 13.36 23.29 ACCEPTABLE
698 -1.82 41.41 13.50 1.89 ACCEPTABLE
699 -0.92 40.03 12.53 1.93 ACCEPTABLE
700 -1.53 40.86 13.17 1.92 ACCEPTABLE
701 -0.97 40.42 12.58 4.65 ACCEPTABLE
702 -1.22 40.26 12.83 1.94 ACCEPTABLE
703 -1.68 41.14 13.34 1.91 ACCEPTABLE
704 -1.10 40.68 12.73 5.94 ACCEPTABLE
705 -1.55 42.18 14.30 1.88 ACCEPTABLE
706 -0.97 41.66 13.66 7.90 ACCEPTABLE
707 -1.33 41.41 13.50 1.88 ACCEPTABLE
708 -1.18 41.74 13.71 7.00 ACCEPTABLE
709 -1.43 41.38 13.27 8.93 ACCEPTABLE
710 -1.84 42.63 14.50 6.95 ACCEPTABLE
711 -1.36 42.09 13.94 9.42 ACCEPTABLE
712 -1.57 42.10 14.15 1.87 ACCEPTABLE
713 -1.43 42.46 14.39 4.98 ACCEPTABLE
714 -1.67 42.07 13.93 8.91 ACCEPTABLE
715 -2.09 43.39 15.22 9.03 ACCEPTABLE
716 -1.61 42.82 14.63 11.00 ACCEPTABLE
717 -1.81 42.83 14.83 1.88 ACCEPTABLE
718 -0.99 41.59 13.83 1.89 ACCEPTABLE
719 -1.62 42.44 14.57 1.90 ACCEPTABLE
720 -1.25 42.10 14.15 2.91 ACCEPTABLE
721 -1.38 41.94 14.26 1.91 ACCEPTABLE

75
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
722 -1.51 41.76 13.72 3.75 ACCEPTABLE
723 -2.15 42.60 14.48 9.04 ACCEPTABLE
724 -1.78 42.28 14.07 14.46 ACCEPTABLE
725 -1.89 42.10 14.15 1.88 ACCEPTABLE
726 -1.28 41.10 13.42 1.91 ACCEPTABLE
727 -1.08 40.94 13.22 1.90 ACCEPTABLE
728 -1.70 41.71 13.90 1.90 ACCEPTABLE
729 -1.32 41.40 13.50 1.88 ACCEPTABLE
730 -1.47 41.26 13.63 1.92 ACCEPTABLE
731 -1.80 41.91 14.03 1.90 ACCEPTABLE
732 -1.42 41.58 13.61 2.81 ACCEPTABLE
733 -1.72 42.63 14.70 1.89 ACCEPTABLE
734 -1.34 42.28 14.27 3.94 ACCEPTABLE
735 -324.96 652.22 698.71 38.39 ACCEPTABLE
736 -324.63 652.22 698.71 37.02 ACCEPTABLE
737 -1.57 42.10 14.15 1.87 ACCEPTABLE
738 -1.48 42.34 14.31 2.91 ACCEPTABLE
739 -1.64 42.08 14.00 3.92 ACCEPTABLE
740 -1.91 42.94 14.84 4.86 ACCEPTABLE
741 -1.59 42.58 14.46 6.66 ACCEPTABLE
742 -1.73 42.58 14.60 1.88 ACCEPTABLE
743 -1.18 41.76 13.93 1.89 ACCEPTABLE
744 -1.61 42.32 14.43 1.89 ACCEPTABLE
745 -1.35 42.10 14.15 1.86 ACCEPTABLE
746 -1.26 42.34 14.31 4.97 ACCEPTABLE
747 -1.42 42.08 14.00 6.00 ACCEPTABLE
748 -1.69 42.94 14.84 3.83 ACCEPTABLE
749 -1.37 42.58 14.46 6.57 ACCEPTABLE
750 -1.51 42.58 14.60 1.87 ACCEPTABLE
751 -0.96 41.76 13.93 1.88 ACCEPTABLE
752 -1.39 42.32 14.43 1.88 ACCEPTABLE
753 -1.13 42.10 14.15 3.93 ACCEPTABLE
754 -1.22 41.99 14.22 1.90 ACCEPTABLE
755 -1.31 41.87 13.87 3.75 ACCEPTABLE
756 -1.74 42.44 14.37 2.90 ACCEPTABLE
757 -1.49 42.22 14.09 8.97 ACCEPTABLE
758 -1.57 42.10 14.15 1.87 ACCEPTABLE
759 -1.15 41.42 13.65 1.89 ACCEPTABLE
760 -1.02 41.31 13.51 1.88 ACCEPTABLE
761 -1.44 41.84 13.99 1.90 ACCEPTABLE
762 -1.19 41.63 13.71 2.90 ACCEPTABLE
763 -1.28 41.53 13.79 1.90 ACCEPTABLE
764 -1.50 41.97 14.07 1.89 ACCEPTABLE
765 -1.25 41.75 13.79 2.81 ACCEPTABLE
766 -1.45 42.45 14.52 1.87 ACCEPTABLE
767 -1.20 42.22 14.23 4.68 ACCEPTABLE
768 -336.15 712.86 757.89 37.39 ACCEPTABLE
769 -1.35 42.10 14.15 1.86 ACCEPTABLE
770 -1.29 42.26 14.26 2.90 ACCEPTABLE
771 -1.40 42.09 14.05 3.94 ACCEPTABLE
772 -1.58 42.66 14.61 1.86 ACCEPTABLE
773 -1.52 42.84 14.73 4.95 ACCEPTABLE
774 -1.63 42.65 14.52 6.96 ACCEPTABLE

76
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
775 -1.81 43.24 15.09 6.93 ACCEPTABLE
776 -1.60 42.99 14.84 8.63 ACCEPTABLE
777 -1.69 43.00 14.92 2.89 ACCEPTABLE
778 -1.32 42.42 14.45 1.87 ACCEPTABLE
779 -1.60 42.81 14.80 1.87 ACCEPTABLE
780 -1.44 42.66 14.61 2.91 ACCEPTABLE
781 -1.49 42.58 14.65 1.88 ACCEPTABLE
782 -1.56 42.51 14.42 4.71 ACCEPTABLE
783 -1.84 42.90 14.77 6.92 ACCEPTABLE
784 -1.68 42.75 14.58 10.13 ACCEPTABLE
785 -1.72 42.66 14.61 1.86 ACCEPTABLE
786 -1.44 42.18 14.25 1.88 ACCEPTABLE
787 -1.35 42.10 14.15 1.86 ACCEPTABLE
788 -1.63 42.48 14.49 1.87 ACCEPTABLE
789 -1.47 42.33 14.30 2.91 ACCEPTABLE
790 -1.52 42.25 14.34 1.88 ACCEPTABLE
791 -1.68 42.57 14.55 1.87 ACCEPTABLE
792 -1.51 42.42 14.36 2.91 ACCEPTABLE
793 -1.65 42.90 14.86 1.87 ACCEPTABLE
794 -1.48 42.75 14.67 3.77 ACCEPTABLE
795 -335.27 709.11 754.22 36.94 ACCEPTABLE
796 -1.58 42.66 14.61 1.86 ACCEPTABLE
797 -1.54 42.78 14.69 2.81 ACCEPTABLE
798 -1.61 42.65 14.55 4.76 ACCEPTABLE
799 -1.73 43.04 14.93 4.84 ACCEPTABLE
800 -1.59 42.88 14.76 4.76 ACCEPTABLE
801 -1.65 42.88 14.82 1.86 ACCEPTABLE
802 -1.61 43.00 14.90 2.92 ACCEPTABLE
803 -1.68 42.87 14.76 4.92 ACCEPTABLE
804 -1.80 43.27 15.15 4.90 ACCEPTABLE
805 -1.66 43.10 14.97 5.77 ACCEPTABLE
806 -1.72 43.11 15.03 2.89 ACCEPTABLE
807 -1.48 42.72 14.71 1.86 ACCEPTABLE
808 -1.66 42.98 14.95 1.87 ACCEPTABLE
809 -1.55 42.88 14.82 2.82 ACCEPTABLE
810 -1.59 42.82 14.84 1.88 ACCEPTABLE
811 -1.64 42.78 14.69 2.89 ACCEPTABLE
812 -1.82 43.04 14.93 4.90 ACCEPTABLE
813 -1.72 42.94 14.80 5.82 ACCEPTABLE
814 -1.75 42.88 14.82 1.86 ACCEPTABLE
815 -1.55 42.55 14.57 1.87 ACCEPTABLE
816 -1.50 42.50 14.51 1.87 ACCEPTABLE
817 -1.68 42.76 14.74 1.87 ACCEPTABLE
818 -1.58 42.66 14.61 1.86 ACCEPTABLE
819 -1.61 42.60 14.63 1.88 ACCEPTABLE
820 -1.72 42.82 14.78 1.87 ACCEPTABLE
821 -1.61 42.72 14.65 1.86 ACCEPTABLE
822 -1.69 43.04 14.99 1.87 ACCEPTABLE
823 -1.58 42.94 14.86 2.92 ACCEPTABLE
824 -335.88 711.72 756.78 36.66 ACCEPTABLE
825 -337.66 721.77 766.61 37.33 ACCEPTABLE
826 -335.78 711.72 756.78 36.47 ACCEPTABLE
827 -1.65 42.88 14.82 1.86 ACCEPTABLE

77
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
828 -1.63 42.96 14.88 2.92 ACCEPTABLE
829 -1.67 42.88 14.78 3.93 ACCEPTABLE
830 -1.75 43.14 15.04 3.90 ACCEPTABLE
831 -1.66 43.03 14.92 3.93 ACCEPTABLE
832 -1.70 43.03 14.96 1.86 ACCEPTABLE
833 -1.53 42.77 14.75 1.87 ACCEPTABLE
834 -1.66 42.95 14.91 1.87 ACCEPTABLE
835 -1.59 42.88 14.82 1.86 ACCEPTABLE
836 -1.61 42.84 14.83 1.87 ACCEPTABLE
837 -1.64 42.81 14.73 1.86 ACCEPTABLE
838 -1.62 42.89 14.79 3.92 ACCEPTABLE
839 -1.66 42.81 14.69 5.76 ACCEPTABLE
840 -1.74 43.07 14.95 4.89 ACCEPTABLE
841 -1.65 42.96 14.83 5.76 ACCEPTABLE
842 -1.69 42.96 14.87 2.88 ACCEPTABLE
843 -1.52 42.70 14.66 1.86 ACCEPTABLE
844 -1.65 42.88 14.81 1.86 ACCEPTABLE
845 -1.58 42.81 14.73 2.82 ACCEPTABLE
846 -1.60 42.77 14.74 1.87 ACCEPTABLE
847 -1.63 42.74 14.65 3.83 ACCEPTABLE
848 -1.76 42.92 14.80 4.90 ACCEPTABLE
849 -1.68 42.85 14.72 6.94 ACCEPTABLE
850 -1.70 42.81 14.73 2.89 ACCEPTABLE
851 -1.57 42.59 14.56 1.87 ACCEPTABLE
852 -1.54 42.56 14.52 2.82 ACCEPTABLE
853 -1.66 42.73 14.67 1.87 ACCEPTABLE
854 -1.59 42.66 14.59 2.91 ACCEPTABLE
855 -1.61 42.62 14.60 1.87 ACCEPTABLE
856 -1.68 42.77 14.70 2.88 ACCEPTABLE
857 -1.61 42.70 14.62 2.82 ACCEPTABLE
858 -1.67 42.92 14.84 1.86 ACCEPTABLE
859 -1.60 42.85 14.76 3.92 ACCEPTABLE
860 -338.14 723.92 768.72 37.52 ACCEPTABLE
861 -338.08 723.92 768.72 37.41 ACCEPTABLE
862 -1.64 42.81 14.73 1.86 ACCEPTABLE
863 -1.62 42.86 14.77 3.93 ACCEPTABLE
864 -1.66 42.81 14.70 4.92 ACCEPTABLE
865 -1.71 42.98 14.87 3.89 ACCEPTABLE
866 -1.65 42.91 14.80 5.59 ACCEPTABLE
867 -1.67 42.91 14.82 3.93 ACCEPTABLE
868 -1.56 42.74 14.68 1.86 ACCEPTABLE
869 -1.65 42.86 14.79 1.86 ACCEPTABLE
870 -1.60 42.81 14.73 2.82 ACCEPTABLE
871 -1.61 42.78 14.74 1.87 ACCEPTABLE
872 -1.63 42.76 14.67 3.92 ACCEPTABLE
873 -1.72 42.88 14.78 3.89 ACCEPTABLE
874 -1.67 42.84 14.72 5.58 ACCEPTABLE
875 -1.68 42.81 14.73 1.86 ACCEPTABLE
876 -1.60 42.66 14.62 1.86 ACCEPTABLE
877 -1.57 42.64 14.59 1.86 ACCEPTABLE
878 -1.66 42.75 14.69 1.86 ACCEPTABLE
879 -1.61 42.71 14.64 1.86 ACCEPTABLE
880 -1.62 42.69 14.65 1.86 ACCEPTABLE

78
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Center Radius
No. FS Verification
x [m] z [m] R [m]
881 -1.67 42.78 14.71 2.88 ACCEPTABLE
882 -1.62 42.74 14.65 3.83 ACCEPTABLE
883 -1.66 42.88 14.81 1.86 ACCEPTABLE
884 -1.61 42.84 14.75 3.93 ACCEPTABLE
885 -336.97 717.72 762.65 37.33 ACCEPTABLE
886 -337.77 722.20 767.03 37.41 ACCEPTABLE
887 -336.93 717.72 762.65 37.25 ACCEPTABLE
888 -1.64 42.81 14.73 1.86 ACCEPTABLE

79
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name : Stability Analysis Stage - analysis : 1 - 1


Description : Stability Analysis

[3

[3

[3
7

3
34.20
33.00

30.00

27.00

24.00

21.00

4
18.00
40.00]
1

40.00]

15.00
[12.82;
[11.80;

6
6 2

12.00
[6.76; 34.00]

9.00
5
1

29.60]
29.60]
[2.23; 28.60]

6.00
29.60]
[3.07;
[2.23;
40.00]

2
[0.00;40.00]

[-5.50; 29.60] [-0.60; 29.60]


[1.73;
23 2 4

3.00
31
2
[-1.64; 42.81]

56
[-0.60;

2
41
5

20.00 0.00
3

3
1

[-5.50; 28.60]

-3.00
[-8.16; 29.60]
3
2
1
2

-6.00
1

-9.00

-12.00

-15.00
4
5

-18.00

-21.00
[-28.50; 29.60]
[-28.50; 28.60]

-24.00

-27.00
1
1

-28.50

80
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Input data (Stage of construction 3)


Geological profile and assigned soils
Position information
Terrain elevation = 40.00 m
Geological profile and assigned soils
Thickness of layer Depth Altitude
No. Assigned soil Pattern
t [m] z [m] [m]

1 6.00 0.00 .. 6.00 40.00 .. 34.00 Existing

2 - 6.00 ..  34.00 .. - LIMESTONE

Foundation
Type of foundation : input parameters of contact base-soil
Parameters
Friction coefficient base-soil  = 0.50
Cohesion base-soil a = 100.00 kPa
Terrain profile
Terrain behind the structure is flat.

Water influence
GWT behind the structure lies at a depth of 0.00 m
GWT in front of the structure lies at a depth of 10.40 m
Subgrade at the heel is permeable.
Hydraulic gradient = 0.00
The evolution of tensile cracks is considered in the analyses. Depth of cracks is 0.10 m.

Input surface surcharges


Surcharge Mag.1 Mag.2 Ord.x Length Depth
No. Action
new change [kN/m2] [kN/m2] x [m] l [m] z [m]
1 No No permanent 20.00 on terrain
No. Name
1 Surcharge Load 20kPa
Resistance on front face of the structure
Resistance on front face of the structure: passive
Soil on front face of the structure - Earth Fill
Angle of friction struc.-soil  = 46.00 °
Soil thickness in front of structure h = 1.00 m
Terrain in front of structure is flat.

Settings of the stage of construction


Design situation : permanent
The wall is free to move. Active earth pressure is therefore assumed.

Verification No. 1 (Stage of construction 3)


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079

81
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11

82
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] overtur. sliding stress
Weight - wall 0.00 -4.11 474.35 5.30 1.000 1.000 1.350
FF resistance -44.38 -0.49 -45.95 0.00 1.000 1.000 1.350
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.000 1.000 1.350
Active pressure 244.81 -2.98 105.57 7.73 1.350 1.350 1.350
Water pressure 592.80 -4.13 90.13 7.73 1.350 1.350 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350 1.350 1.350
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.350 1.350 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000 1.000 1.350
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 4419.77 kNm/m
Overturning moment Movr = 4672.69 kNm/m
Wall for overturning is NOT SATISFACTORY

Check for slip


Resisting horizontal force Hres = 718.16 kN/m
Active horizontal force Hact = 1170.37 kN/m
Wall for slip is NOT SATISFACTORY

Overall check - WALL is NOT SATISFACTORY

Maximum stress in footing bottom : 282.00 kPa

Bearing capacity of foundation soil (Stage of construction 3)


Design load acting at the center of footing bottom
Moment Norm. force Shear Force Eccentricity Stress
No.
[kNm/m] [kN/m] [kN/m] [–] [kPa]
1 1555.34 1139.69 1154.84 0.176 227.76
2 2059.25 924.37 1170.37 0.288 282.00
Service load acting at the center of footing bottom
Moment Norm. force Shear Force
No.
[kNm/m] [kN/m] [kN/m]
1 1152.10 844.21 855.44
Dimensioning No. 1 (Stage of construction 3)
Wall stem check - front vertical reinf.
Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079

83
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11

84
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -44.38 -0.49 -45.95 0.00 1.000
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.000
Active pressure 244.81 -2.98 105.57 7.73 1.000
Water pressure 592.80 -4.13 90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - front vertical reinf. - MEd
Wall check at the construction joint 5.20 m from the wall crest
Hi = 161.22 kPa
MEd = 0.03 * Hi * H1 * l / 4 * b = 0.03 * 161.22 * 10.40 * 4.00 / 4 * 1.00 = 50.30 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.57 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 0.86 m = xmax
Ultimate moment MRd = 4716.61 kNm > 50.30 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - front vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 157.86 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32

85
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure behind the structure - partial results


Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000

86
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
FF resistance -44.38 -0.49 -45.95 0.00 1.000
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.000
Active pressure 244.81 -2.98 105.57 7.73 1.000
Water pressure 592.80 -4.13 90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - back vertical reinf. - MEd
Wall check at the construction joint 10.40 m from the wall crest
Hi = 161.22 kPa
MEd = 0.03 * Hi * H1 * l * b = 0.03 * 161.22 * 10.40 * 4.00 * 1.00 = 201.11 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 2.33 m
Reinforcement ratio  = 0.35 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 1.40 m = xmax
Ultimate moment MRd = 7746.39 kNm > 201.11 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 157.86 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - front horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355

87
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Layer Thickness  d cd  d Ka Comment


No. [m] [°] [°] [kPa] [kN/m3] [°]
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -44.38 -0.49 -45.95 0.00 1.000
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.000
Active pressure 244.81 -2.98 105.57 7.73 1.000

88
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Water pressure 592.80 -4.13 90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - front horizontal reinf.
pi = 78.93 kPa
MEd = 1 / 20 * pi * l2 = 1 / 20 * 78.93 * 4.002 = 656.71 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.17 % > 0.17 % = min
Position of neutral axis x = 0.06 m < 0.87 m = xmax
Ultimate shear force VRd = 4887.88 kN > 1641.76 kN = VEd
Ultimate moment MRd = 15328.55 kNm > 656.71 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - back horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19

89
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Layer Start [m] Z W Pressure Hor. comp. Vert. comp.


No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -44.38 -0.49 -45.95 0.00 1.000
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.000
Active pressure 244.81 -2.98 105.57 7.73 1.000
Water pressure 592.80 -4.13 90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - back horizontal reinf.
pi = 78.93 kPa
MEd = 1 / 12 * pi * l2 = 1 / 12 * 78.93 * 4.002 = 1094.51 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m

90
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Reinforcement ratio  = 0.17 % > 0.17 % = min


Position of neutral axis x = 0.06 m < 0.87 m = xmax
Ultimate shear force VRd = 4887.88 kN > 1641.76 kN = VEd
Ultimate moment MRd = 15328.55 kNm > 1094.51 kNm = MEd
Cross-section is SATISFACTORY.

Wall jump check - bottom reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00

91
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Pressure profile due to surcharge - Tensile crack


Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -44.38 -0.49 -45.95 0.00 1.350
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.350
Active pressure 244.81 -2.98 105.57 7.73 1.350
Water pressure 592.80 -4.13 90.13 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.350
Wall jump check - bottom reinf.
j1 = 303.68 kPa
MEd = 1 / 12 * j1 * l2 = 1 / 12 * 303.68 * 4.002 = 1984.03 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate moment MRd = 3212.47 kNm > 1984.03 kNm = MEd
Cross-section must be reinforced by shear reinforcement with minimal area of 3257.2 mm2/m.
Cross-section is SATISFACTORY.

Wall jump check - top reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 1.61 -46.00 4.079

92
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 1.61 0.00 67.17 46.66 -48.32
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.36 0.00 25.00 15.00 18.39 25.00 0.355
2 3.64 0.00 25.00 15.00 18.39 25.00 0.355
3 4.40 0.00 25.00 15.00 18.39 25.00 0.355
4 1.00 0.00 25.00 15.00 18.39 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.36 43.36 23.58 0.00 0.00 0.00
2.36 43.36 23.58 0.00 0.00 0.00
2
6.00 110.32 60.00 23.77 21.55 10.05
6.00 110.32 60.00 23.77 21.55 10.05
3
10.40 191.23 104.00 52.50 47.58 22.19
10.40 191.23 104.00 52.63 50.33 15.39
4
11.40 209.61 0.00 59.25 56.66 17.32
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.36 23.58 3.93
3 6.00 60.00 10.00
4 10.40 104.00 17.33
5 10.40 104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.36 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11

93
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -44.38 -0.49 -45.95 0.00 1.350
Weight - earth wedge 0.00 -7.30 142.13 6.96 1.350
Active pressure 244.81 -2.98 105.57 7.73 1.350
Water pressure 592.80 -4.13 90.13 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Surcharge Load 20kPa 62.15 -4.77 33.32 7.73 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.350
Wall jump check - top reinf.
j1 = 303.68 kPa
MEd = 1 / 20 * j1 * l2 = 1 / 20 * 303.68 * 4.002 = 1190.42 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate moment MRd = 3212.47 kNm > 1190.42 kNm = MEd
Cross-section must be reinforced by shear reinforcement with minimal area of 3257.2 mm2/m.
Cross-section is SATISFACTORY.

Buttress check
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.91 9.46 25.00 15.00 18.39 17.00 0.435
2 4.09 9.46 25.00 15.00 18.39 17.00 0.435
3 4.40 9.46 25.00 15.00 18.39 17.00 0.435
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
1.91 35.10 19.09 0.00 0.00 0.00
1.91 35.10 19.09 0.00 0.00 0.00
2
6.00 110.32 60.00 32.69 29.27 14.57
6.00 110.32 60.00 32.69 29.27 14.57
3
10.40 191.20 103.99 67.84 60.74 30.23

94
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Water pressure distribution


Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 1.91 19.09 3.18
3 6.00 60.00 10.00
4 10.40 103.99 17.33
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 7.78 3.87
2 1.91 7.78 3.87
3 6.00 7.78 3.87
4 10.40 7.78 3.87
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] moment norm.force shear for.
Weight - wall 0.00 -4.18 366.01 0.82 1.350 1.350 1.000
Active pressure 257.81 -2.83 128.33 1.86 1.350 1.350 1.350
Water pressure 540.67 -3.47 90.11 1.76 1.350 1.350 1.350
Tensile crack 0.05 -10.33 0.00 0.60 1.350 1.000 1.350
Surcharge Load 20kPa 70.29 -4.52 40.28 1.47 1.350 1.350 1.350
Buttress check
Wall check at the construction joint 10.40 m from the wall crest
Shear reinf. - 2 profile 16.0 mm; distance 200.0 mm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 0.60 m
Cross-section height = 7.23 m
Reinforcement ratio  = 0.19 % > 0.17 % = min
Position of neutral axis x = 0.31 m < 4.42 m = xmax
Ultimate shear force VRd = 14096.07 kN > 5395.42 kN = VEd
Ultimate moment MRd = 24623.00 kNm > 17978.69 kNm = MEd
Cross-section is SATISFACTORY.

Input data (Stage of construction 4)


Geological profile and assigned soils
Position information
Terrain elevation = 40.00 m
Geological profile and assigned soils

95
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Thickness of layer Depth Altitude


No. Assigned soil Pattern
t [m] z [m] [m]

1 6.00 0.00 .. 6.00 40.00 .. 34.00 Existing

2 - 6.00 ..  34.00 .. - LIMESTONE

Foundation
Type of foundation : input parameters of contact base-soil
Parameters
Friction coefficient base-soil  = 0.50
Cohesion base-soil a = 100.00 kPa
Terrain profile
Terrain behind the structure is flat.

Water influence
GWT behind the structure lies at a depth of 10.40 m
GWT in front of the structure lies at a depth of 0.00 m
Subgrade at the heel is permeable.
Hydraulic gradient = -5.20
The evolution of tensile cracks is considered in the analyses. Depth of cracks is 0.10 m.

Input surface surcharges


Surcharge Mag.1 Mag.2 Ord.x Length Depth
No. Action
new change [kN/m2] [kN/m2] x [m] l [m] z [m]
1 No No permanent 20.00 on terrain
No. Name
1 Surcharge Load 20kPa
Resistance on front face of the structure
Resistance on front face of the structure: passive
Soil on front face of the structure - Earth Fill
Angle of friction struc.-soil  = 46.00 °
Soil thickness in front of structure h = 1.00 m
Terrain in front of structure is flat.

Settings of the stage of construction


Design situation : permanent
The wall is free to move. Active earth pressure is therefore assumed.

Verification No. 1 (Stage of construction 4)


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53

96
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure behind the structure - partial results


Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] overtur. sliding stress
Weight - wall 0.00 -4.11 474.35 5.30 1.000 1.000 1.350

97
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.


[kN/m] z [m] [kN/m] x [m] overtur. sliding stress
FF resistance -129.94 -0.39 -134.56 0.00 1.000 1.000 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000 1.000 1.350
Active pressure 233.88 -3.00 101.20 7.73 1.350 1.350 1.350
Water pressure -592.80 -4.13 -90.13 7.73 1.000 1.000 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350 1.350 1.350
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.350 1.350 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000 1.000 1.350
Verification of complete wall
Check for overturning stability
Resisting moment Mres = 3782.33 kNm/m
Overturning moment Movr = -1155.41 kNm/m
Wall for overturning is SATISFACTORY

Check for slip


Resisting horizontal force Hres = 1035.65 kN/m
Active horizontal force Hact = -323.38 kN/m
Wall for slip is SATISFACTORY

Overall check - WALL is SATISFACTORY

Maximum stress in footing bottom : 119.52 kPa


Soil in front of the structure heel is washed away due to water flow!
The analysis assumes a zero increment of stress Z.

Bearing capacity of foundation soil (Stage of construction 4)


Design load acting at the center of footing bottom
Moment Norm. force Shear Force Eccentricity Stress
No.
[kNm/m] [kN/m] [kN/m] [–] [kPa]
1 -5113.64 924.32 -576.34 0.000 119.52
2 -3621.19 731.76 -323.38 0.000 94.62
Service load acting at the center of footing bottom
Moment Norm. force Shear Force
No.
[kNm/m] [kN/m] [kN/m]
1 -3787.88 684.68 -426.92
Dimensioning No. 1 (Stage of construction 4)
Wall stem check - front vertical reinf.
Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53

98
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure behind the structure - partial results


Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000

99
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
FF resistance -129.94 -0.39 -134.56 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 233.88 -3.00 101.20 7.73 1.000
Water pressure -592.80 -4.13 -90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - front vertical reinf. - MEd
Wall check at the construction joint 5.20 m from the wall crest
Hi = 55.83 kPa
MEd = 0.03 * Hi * H1 * l / 4 * b = 0.03 * 55.83 * 10.40 * 4.00 / 4 * 1.00 = 17.42 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 1.47 m
Reinforcement ratio  = 0.57 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 0.86 m = xmax
Ultimate moment MRd = 4716.61 kNm > 17.42 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - front vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 52.10 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355

100
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Layer Thickness  d cd  d Ka Comment


No. [m] [°] [°] [kPa] [kN/m3] [°]
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -129.94 -0.39 -134.56 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 233.88 -3.00 101.20 7.73 1.000

101
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Name Fhor App.Pt. Fvert App.Pt. Design


[kN/m] z [m] [kN/m] x [m] coefficient
Water pressure -592.80 -4.13 -90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - back vertical reinf. - MEd
Wall check at the construction joint 10.40 m from the wall crest
Hi = 55.83 kPa
MEd = 0.03 * Hi * H1 * l * b = 0.03 * 55.83 * 10.40 * 4.00 * 1.00 = 69.65 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 2.33 m
Reinforcement ratio  = 0.35 % > 0.17 % = min
Position of neutral axis x = 0.10 m < 1.40 m = xmax
Ultimate moment MRd = 7746.39 kNm > 69.65 kNm = MEd
Cross-section is SATISFACTORY.

Wall stem check - back vertical reinf. - VEd


Wall check at the construction joint 0.00 m from the wall crest
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 1.00 m
Cross-section height = 0.60 m
Ultimate shear force VRd = 387.38 kN > 52.10 kN = VEd
Cross-section is SATISFACTORY.

Wall stem check - front horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360

102
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure distribution behind the structure (without surcharge)


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -129.94 -0.39 -134.56 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 233.88 -3.00 101.20 7.73 1.000
Water pressure -592.80 -4.13 -90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000

103
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Wall stem check - front horizontal reinf.


pi = -26.05 kPa
MEd = 1 / 20 * pi * l2 = 1 / 20 * -26.05 * 4.002 = -216.74 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Fibers loaded in tension are on the front side of the cross-section, the cross-section cannot be checked
using this program.

Wall stem check - back horizontal reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00

104
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.000
FF resistance -129.94 -0.39 -134.56 0.00 1.000
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.000
Active pressure 233.88 -3.00 101.20 7.73 1.000
Water pressure -592.80 -4.13 -90.13 7.73 1.000
Tensile crack 0.05 -11.33 0.00 7.73 1.000
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.000
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.000
Wall stem check - back horizontal reinf.
pi = -26.05 kPa
MEd = 1 / 12 * pi * l2 = 1 / 12 * -26.05 * 4.002 = -361.23 kNm
Reinforcement and dimensions of the cross-section
52 prof. 25.0 mm, cover 50.0 mm
Cross-section width = 10.40 m
Cross-section height = 1.47 m
Fibers loaded in tension are on the front side of the cross-section, the cross-section cannot be checked
using this program.

Wall jump check - bottom reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079

105
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Passive pressure distribution on front face of the structure


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11

106
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -129.94 -0.39 -134.56 0.00 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.350
Active pressure 233.88 -3.00 101.20 7.73 1.350
Water pressure -592.80 -4.13 -90.13 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.350
Wall jump check - bottom reinf.
j1 = 119.52 kPa
MEd = 1 / 12 * j1 * l2 = 1 / 12 * 119.52 * 4.002 = 780.89 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate shear force VRd = 1676.48 kN > 1171.34 kN = VEd
Ultimate moment MRd = 3212.47 kNm > 780.89 kNm = MEd
Cross-section is SATISFACTORY.

Wall jump check - top reinf.


Passive pressure on front face of the structure - partial results
Layer Thickness  d cd  d Kp Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.00 0.00 25.00 15.00 62.00 -46.00 4.079
Passive pressure distribution on front face of the structure
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 60.59 42.09 -43.59
1
1.00 62.00 0.00 313.52 217.79 -225.53
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 2.41 0.00 25.00 15.00 18.00 25.00 0.355
2 3.59 0.00 25.00 15.00 18.00 25.00 0.355
3 4.40 0.00 25.00 15.00 18.00 25.00 0.355
4 1.00 0.00 25.00 15.00 -42.00 17.00 0.360

107
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Active pressure distribution behind the structure (without surcharge)


Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
2.41 43.36 -24.09 0.00 0.00 0.00
2.41 43.36 -24.09 0.00 0.00 0.00
2
6.00 108.00 -60.00 22.95 20.80 9.70
6.00 108.00 -60.00 22.95 20.80 9.70
3
10.40 187.20 -104.00 51.07 46.29 21.58
10.40 187.20 -104.00 51.18 48.94 14.96
4
11.40 187.20 0.00 51.18 48.94 14.96
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 2.41 -24.09 -4.02
3 6.00 -60.00 -10.00
4 10.40 -104.00 -17.33
5 10.40 -104.00 0.00
6 11.40 0.00 0.00
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 6.44 3.00
2 2.41 6.44 3.00
3 6.00 6.44 3.00
4 10.40 6.44 3.00
5 10.40 6.89 2.11
6 11.40 6.89 2.11
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Design
[kN/m] z [m] [kN/m] x [m] coefficient
Weight - wall 0.00 -4.11 474.35 5.30 1.350
FF resistance -129.94 -0.39 -134.56 0.00 1.350
Weight - earth wedge 0.00 -7.30 255.84 6.96 1.350
Active pressure 233.88 -3.00 101.20 7.73 1.350
Water pressure -592.80 -4.13 -90.13 7.73 1.350
Tensile crack 0.05 -11.33 0.00 7.73 1.350
Surcharge Load 20kPa 61.90 -4.75 33.32 7.73 1.350
Surcharge Load 20kPa 0.00 -11.40 44.67 6.62 1.350

108
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Wall jump check - top reinf.


j1 = 119.52 kPa
MEd = 1 / 20 * j1 * l2 = 1 / 20 * 119.52 * 4.002 = 468.53 kNm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 4.90 m
Cross-section height = 1.00 m
Reinforcement ratio  = 0.18 % > 0.17 % = min
Position of neutral axis x = 0.04 m < 0.58 m = xmax
Ultimate shear force VRd = 1676.48 kN > 1171.34 kN = VEd
Ultimate moment MRd = 3212.47 kNm > 468.53 kNm = MEd
Cross-section is SATISFACTORY.

Buttress check
Active pressure behind the structure - partial results
Layer Thickness  d cd  d Ka Comment
No. [m] [°] [°] [kPa] [kN/m3] [°]
1 1.95 9.46 25.00 15.00 18.00 17.00 0.435
2 4.05 9.46 25.00 15.00 18.00 17.00 0.435
3 4.40 9.46 25.00 15.00 18.00 17.00 0.435
Active pressure distribution behind the structure (without surcharge)
Layer Start [m] Z W Pressure Hor. comp. Vert. comp.
No. End [m] [kPa] [kPa] [kPa] [kPa] [kPa]
0.00 0.00 0.00 0.00 0.00 0.00
1
1.95 35.10 -19.50 0.00 0.00 0.00
1.95 35.10 -19.50 0.00 0.00 0.00
2
6.00 108.00 -60.00 31.68 28.36 14.12
6.00 108.00 -60.00 31.68 28.36 14.12
3
10.40 187.18 -103.99 66.09 59.17 29.45
Water pressure distribution
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 1.95 -19.50 -3.25
3 6.00 -60.00 -10.00
4 10.40 -103.99 -17.33
Pressure profile due to surcharge - Tensile crack
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 0.00 0.00
2 0.10 1.00 0.00
3 0.10 0.00 0.00
Pressure profile due to surcharge - Surcharge Load 20kPa
Point Depth Hor. comp. Vert. comp.
No. [m] [kPa] [kPa]
1 0.00 7.78 3.87

109
[GEO5 - Cantilever Wall | version 5.2019.79.0 | hardware key 5 / 10 | Copyright © 2019 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Peruding Azman, Ooi & Rao Sdn Bhd 11.4m HEIGHT BUTTRESS RC WALL ANALYSIS AND DESIGN
PERUNDING AZMAN, OOI & RAO / DR. OUTLET STRUCTURE BUTTRESS RC WALL

Point Depth Hor. comp. Vert. comp.


No. [m] [kPa] [kPa]
2 1.95 7.78 3.87
3 6.00 7.78 3.87
4 10.40 7.78 3.87
Forces acting on construction
Name Fhor App.Pt. Fvert App.Pt. Coeff. Coeff. Coeff.
[kN/m] z [m] [kN/m] x [m] moment norm.force shear for.
Weight - wall 0.00 -4.18 366.01 0.82 1.350 1.350 1.000
Active pressure 249.95 -2.82 124.41 1.86 1.350 1.350 1.350
Water pressure -540.67 -3.47 -90.11 1.76 1.000 1.000 1.000
Tensile crack 0.05 -10.33 0.00 0.60 1.350 1.000 1.350
Surcharge Load 20kPa 70.07 -4.51 40.28 1.47 1.350 1.350 1.350
Buttress check
Wall check at the construction joint 10.40 m from the wall crest
Shear reinf. - 2 profile 16.0 mm; distance 200.0 mm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 0.60 m
Cross-section height = 7.23 m
Fibers loaded in tension are on the front side of the cross-section, the cross-section cannot be checked
using this program.

Buttress check - MEd


Wall check at the construction joint 0.00 m from the wall crest
Shear reinf. - 2 profile 16.0 mm; distance 200.0 mm
Reinforcement and dimensions of the cross-section
10 prof. 32.0 mm, cover 50.0 mm
Cross-section width = 0.60 m
Cross-section height = 1.10 m
Reinforcement ratio  = 1.30 % > 0.17 % = min
Position of neutral axis x = 0.31 m < 0.64 m = xmax
Ultimate moment MRd = 3181.47 kNm > 0.00 kNm = MEd
Cross-section is SATISFACTORY.

110