Sei sulla pagina 1di 44

LVP 03 T A

Replaces: LVP 02 T A - LVP 04 T E

Variable displacement axial piston pumps,


Modification from former edition

LVP series
DISPLACEMENTS for open circuit
MAX SPEED
From 1.74 in3/rev
(28,49 cm3/rev) 3000 min-1
To 5.37 in3/rev
(87,90 cm3/rev)

PRESSURE
Max. continuous 4060 psi
(280 bar)
Max. intermittent 4568 psi
APPLICATION
(315 bar)
Mediun, high pressure
Max. peak 5075 psi
(350 bar) SECTOR
Mobile / Industrial
Edition: 03/01.2007

l Energy savings. Variable displacement axial piston pumps with


swash plate design.
l Low noise emission. LVP pumps are ideally suited for medium and
l Operational flexibility. high pressure open circuit applications.
They are available with a wide range of control
l Wide range of controls. options to regulate the pumps displacement.
The drive shaft is designed for both radial and
l Short response time. axial loads. The pumps are also available with a
l Drive shaft bearing suitable for through drive option to have multiple pumps
radial and axial loads. able to supply several hydraulic systems.

*D0015420*
Plata 3000

GENERAL INFORMATIONS / INSTRUCTIONS

1 - Pump body
2 - Swash plate
3 - Piston
4 - Cylinders block
5 - Cover
6 - Retaining plate
7 - Counterbalancing spring
8 - Piston guide plate

INSTALLATION
Check that the maximum coupling eccentricity stays within
0.0098 in (0,25 mm) to reduce shaft loads due to misalignment.
It is advised to use a flexible coupling suitable to absorb even-
tual rotational shock. For applications with axial and radial loads
exceeding published standards, consult our sales department.
DIRECTION OF ROTATION The direction of rotation of the pump must agree with the prime
Clockwise or anti-clockwise defined looking at the drive shaft. mover rotation. Before installation, the case of the pump must
be filled with fluid.
HYDRAULIC FLUID
LINES
Mineral oil based hydraulic fluid HL or HLP type conforming to
DIN 51524 and fire resistant fluids HF type in according to the The lines must have a major diameter which is at least as large
technical data shown in the tables on page 4. The system sho- as the diameter of pump ports, and must be perfectly sealed. To
uld be designed to prevent aeration of the hydraulic fluid. reduce loss of power, the lines should be as short as possible,
reducing the sources of hydraulic resistance (elbow, throttling,
FLUID VISCOSITY gate valves, etc.) to a minimum. A length of flexible tubing is re-
The fluid viscosity range for optimal use of LVP pump is betwe- commended to reduce the transmission of vibrations.
en 77 and 163 SSU (15 and 35 cSt). Before connecting the lines, remove any plugs and make sure
Functional limit conditions are: that the lines are perfectly clean.
max.: 6818 SSU (1500 cSt) at start up at -13 °F (-25 °C) with Check that the drain line is dimensioned in a way to guarantee a
straight and short inlet line. case pressure lower than 22 psi (1,5 bar) absolute.
min.: 58 SSU (10 cSt) at maximum temperature of 194 °F The drain line must be connected directly (no filter, no valves,
(90 °C) no oil cooler) to the tank and must terminate below the oil level.
Check that the dimensions of the suction line guarantee a pres-
FILTRATION sure equal or superior to 24 in Hg (0,8 bar). Inlet pressure less
To ensure the optimal performance and the maximum life to the than 24 in Hg (0,8 bar) could cause an increase of noise emis-
pump, the hydraulic fluid must have and maintain a fluid conta- sion, decreasing pump performance and a reduction of its life
mination within the values shown in the table below. expectancy.

STARTING UP
Working pressure Dp<2030 2030<Dp<3045 Dp>3045
› 03/01.2007

psi (bar)
Check that all connections are secure and that the entire
(140) (140) (210) (210)
system is completely clean. Add oil to the tank always using a fil-
Contamination ter. Bleed the air from the circuit to help the filing. Turn on the
class NAS 1638 9 8 7
system for a few moments at minimum speed, then bleed the
Contamination circuit again and check the level of oil in the tank. Gradually in-
class ISO 4406:1999 20/18/15 19/17/14 18/16/13
crease the pressure and speed of rotation up to the pre-set ope-
Achieved with filter rating levels, which must stay within the stated limits as speci-
ß 10 (c) ³75 according 10 mm 10 mm 10 mm fied in the catalogue.
to ISO 16889

Casappa recommends to use its own


production filters:

2 004 D037-001
Plata 3000

MOUNTING POSITIONS

Standard pump is available with the D2 drain hole open and D1 D2


plugged.
Before installation fill the pump with hydraulic oil for at least 3/4
of the volume keeping it in horizzontal position.
The pump can be mounted in a horizontal or vertical position.
The highest of the case drain ports must be used to keep the re-
quired filling oil.
The pump can be located above the oil level if the absolute pres-
sure at the inlet port stays within the stated limits.
With exception of pump mounted below the oil level, we recom-
mend to interpose a baffle plate between inlet and drain line.
To reduce further noise emission, we recommend that the
pump be mounted below the oil level and avoid suction lines
with sharp restrictions.
D1

HORIZONTAL MOUNTING VERTICAL MOUNTING

D2
Arrangement inside the tank. Arrangement inside the tank.
D2
Minimum oil level equal or above the Minimum oil level equal or above the
pump mounting face. pump mounting face.
IN A ³ 7.874 in (200 mm) A A ³ 7.874 in (200 mm)
IN
A

Arrangement inside the tank. Arrangement inside the tank.


D2 D2
Minimum oil level below the pump Minimum oil level below the pump
mounting face. mounting face.
B

Min. inlet pressure= 24 in Hg Min. inlet pressure= 24 in Hg


B

(0,8 bar abs.) (0,8 bar abs.)


C

IN
B £ 31.4961 in (800 mm) B £ 31.4961 in (800 mm)
IN
C

C = 7.874 in (200 mm) C = 7.874 in (200 mm)

D2
Arrangement outside the tank D2 Arrangement outside the tank
above oil level. above oil level.
Min. inlet pressure= 24 in Hg Min. inlet pressure= 24 in Hg
B

(0,8 bar abs.) (0,8 bar abs.)


B

B £ 31.4961 in (800 mm) B £ 31.4961 in (800 mm)


C = 7.874 in (200 mm) C = 7.874 in (200 mm)
C

IN
C

IN
› 03/01.2007
C

IN
D2 Arrangement outside the tank
below oil level.
C = 7.874 in (200 mm)

IN= inlet line - D1= drain line - A= min. distance between the line - B+C= permissible suction height - C= line immersion depth

D037-001 004 3
Plata 3000

TECHNICAL DATA

Technical data with mineral oil

HL or HLP mineral oil based hydraulic fluid to DIN 51524 LVP 30 LVP 48 LVP 75 LVP 90
3 3
Max. displacement (theor.) Vmax in /rev (cm /rev) 1.77 (29) 2.81 (46) 4.45 (73) 5.36 (87,9)
in Hg (bar abs.) min. 24 (0.8)
Inlet pressure
psi (bar abs.) max. 363 (25)
continuous 4060 (280) 4060 (280) 4060 (280) 3625 (250)
Max. outlet pressure pmax psi (bar) intermittent 4568 (315) 4568 (315) 4568 (315) 4060 (280)
peak 5075 (350) 5075 (350) 5075 (350) 4568 (315)
Max. drain line pressure psi (bar abs.) 22 (1,5)
Max. speed nmax min - 1 @ V m a x (1) 3000 2600 2200 1850
@ nmax 23 (87) 31.6 (119,6) 42.4 (160,6) 43 (162,6)
Max. delivery (theor.) US gpm (l/min) @ 1800 min - 1 13.8 (52,2) 21.9 (82,8) 34.7 (131,4) 41.8 (158,2)
@ 1500 min - 1 11.5 (43,5) 18.2 (69) 28.9 (109,5) 34.8 (131,9)
@ nmax 54.4 (40,6) 74.8 (55,8) 100.4 (74,9) 90.9 (67,8)
Max. power (theor.)
(Dp = pmax cont.) HP (kW) @ 1800 min - 1 32.7 (24,4) 51.7 (38,6) 82.1 (61,3) 88.3 (65,9)
@ 1500 min - 1 27.2 (20,3) 43.1 (32,2) 68.5 (51,1) 73.6 (54,9)
@ p m a x cont. 1144 (129,2) 1814 (205) 2879 (325,3) 3096 (349,8)
Max. torque (theor.) lbf in (Nm) @ 1450 psi
409 (46,2) 648 (73,2) 1028 (116,2) 1238 (139,9)
(100 bar)
Moment of inertia ft 2 lbs (kgm 2 ) 0.05 (0,002) 0.07 (0,003) 0.19 (0,008) 0.19 (0,008)
Fill capacity US gallons (l) 0.18 (0,7) 0.24 (0,9) 0.40 (1,5) 0.40 (1,5)
Mass (without oil) lbs (kg) 39.69 (18) 52.92 (24) 72.77 (33) 72.77 (33)
Seals N= Buna V= Viton
min. -13 (-25) 14 (-10)
Operating temperature °F (°C) max. cont. 176 (80) 230 (110)
max. peak 212 (100) 257 (125)

(1) = with an inlet pressure of 14.5 psi (1 bar abs)


Reducing the displacement or increasing the inlet pressure the max. speed change. See table at page 5.
For different working conditions, please consult our sales department.

Technical data restrictions with fire resistant fluid

Water - glycol (35 ¸ 55 % of water) - HFC LVP 30 LVP 48 LVP 75 LVP 90


continuous 2465 (170)
Max. outlet pressure pmax psi (bar) intermittent 2683 (185)
peak 2900 (200)
Max. speed nmax min - 1 @ V m a x (1) 2100 2000 1700 1700
Seals N= Buna V= Viton
min. 0
Operating temperature °F (°C)
max. 194 (90)
Life bearing % 75
› 03/01.2007

Phosphate ester - HFD LVP 30 LVP 48 LVP 75 LVP 90


continuous 2900 (200)
Max. outlet pressure pmax psi (bar) intermittent 3190 (220)
peak 3480 (240)
Max. speed nmax min - 1 @ V m a x (1) 2100 2000 1700 1700
Seals V= Viton
min. 14 (-10)
Operating temperature °F (°C)
max. 122 (50)
Life bearing % 90

4 004 D037-001
Plata 3000

TECHNICAL DATA

Design calculations for pump

Q US gpm (l/min) Flow


M lbf in (Nm) Torque
P HP (kW) Power Q= V • h v • n • 10 -3 (l/min)
3 3
V in /rev (cm /rev) Displacement
Dp • V
n min-1 Speed M= (Nm)
62,83 • h m
Dp psi (bar) Pressure
Dp • V • n
hv = hv (V,Dp, n) Volumetric efficiency P= (kW)
600 • 1000• h t
hm= hm (V,Dp, n) Mechanical efficiency

ht = hv • hm Overall efficiency

Max. permissible loading on drive shaft

External load position LVP 30 LVP 48 LVP 75 LVP 90

F a x Axial force lbf (N) 225 (1000) 337 (1500) 450 (2000) 450 (2000)

F r a d Radial force @ L/2 lbf (N) 337 (1500) 337 (1500) 675 (3000) 675 (3000)

% Variation of the max. speed in relation of the inlet pressure and/or displacement reduction

Inlet
Displacement %
pressure
psi (bar abs.) 65 70 80 90 100
12 (0,8) 120 115 105 97 90
of the max. speed

13 (0,9) 120 120 110 103 95


% Variation
› 03/01.2007

14.5 (1,0) 120 120 115 107 100


17 (1,2) 120 120 120 113 106
20 (1,4) 120 120 120 120 112
23 (1,6) 120 120 120 120 117
29 (2,0) 120 120 120 120 120

Example 1 Example 2
Displacement: 100 % Displacement: 80 %
Speed: 100 % Inlet pressure: 14.5 psi (1,0 bar abs.)
Inlet pressure: 14.5 psi (1,0 bar abs.) Speed: 115 %

D037-001 004 5
Plata 3000

OPERATING CURVES / TECHNICAL DATA

Delivery / power (max. displacement)


Each curve has been obtained at 122 °F (50 °C), using oil with viscosity 164 SSU (36 cSt) at 104 °F (40 °C) and at these speed:
(1) 1500 min-1 (3) 3000 min-1 (5) 2200 min-1
(2) 1800 min-1 (4) 2600 min-1

LVP 30 LVP 48

LVP 75 LVP 90

› 03/01.2007

6 004 D037-001
Plata 3000

NOISE LEVEL CURVES

Qmax For each curve the sound pressure has been measured in a
semi-anechoic chamber at 122 °F (50 °C), using oil with
Qmin viscosity 164 SSU (36 cSt) at 104 °F (40 °C).
Distance from microphone to pump = 39.37 in (1 m)
Measuring error = ± 2 dB (A)

LVP 30 LVP 48

-1

m in -1
00 in
30 00
m
26
-1
in
0 0m -1
15 i n
00m
15

LVP 75 LVP 90

-1

m in
00
22
-1
in
› 03/01.2007

m
00
18
-1 -1

m in m in
00 00
15 15

D037-001 004 7
Plata 3000

VERSION WITH SIDE PORTS - DIMENSIONS LVP 30

PORTS Optional:
E: Max. displacement limiter (l)
IN OUT
D1, D2 F: Min. displacement limiter (l)
SAE 3000 SAE 6000 (l) One turn of screw changes
Nominal size pump displacement by approximately
Drain port
1" 1/4 3/4" 0.09 in3/rev (1,5 cm3/rev)

Dimensions at page 18
› 03/01.2007

Screws tightening torque Nm (lbf in)

V V1
±1 ±7
10 (80 ¸ 97) 70 (558 ¸ 682)

8 004 D037-002
Plata 3000

VERSION WITH REAR PORTS - DIMENSIONS LVP 30

PORTS Optional:
E: Max. displacement limiter (l)
IN OUT
D1, D2 F: Min. displacement limiter (l)
SAE 3000 SAE 6000 (l) One turn of screw changes
Nominal size pump displacement by approximately
Drain port
1" 1/4 3/4" 0.09 in3/rev (1,5 cm3/rev)

Dimensions at page 18
› 03/01.2007

Screws tightening torque Nm (lbf in)

V V1
±1 ±7
10 (80 ¸ 97) 70 (558 ¸ 682)

D037-002 004 9
Plata 3000

VERSION WITH SIDE PORTS - DIMENSIONS LVP 48

PORTS Optional:
E: Max. displacement limiter (l)
IN OUT
D1, D2 F: Min. displacement limiter (l)
SAE 3000 SAE 6000 (l) 1 One turn of screw changes
Nominal size pump displacement by approximately
Drain port
1" 1/2 1" 0.13 in3/rev (2,2 cm3/rev)

Dimensions at page 18
› 03/01.2007

Screws tightening torque Nm (lbf in)

V V1
±1 ±10
10 (80 ¸ 97) 100 (797 ¸ 974)

10 004 D037-002
Plata 3000

VERSION WITH REAR PORTS - DIMENSIONS LVP 48

PORTS Optional:
E: Max. displacement limiter (l)
IN OUT
D1, D2 F: Min. displacement limiter (l)
SAE 3000 SAE 6000 (l) One turn of screw changes
Nominal size pump displacement by approximately
Drain port
1" 1/2 1" 0.13 in3/rev (2,2 cm3/rev)

Dimensions at page 18
› 03/01.2007

Screws tightening torque Nm (lbf in)

V V1
±1 ±10
10 (80 ¸ 97) 100 (797 ¸ 974)

D037-002 004 11
Plata 3000

VERSION WITH SIDE PORTS - DIMENSIONS LVP 75 - 90

PORTS Optional:
E: Max. displacement limiter (l)
IN OUT
D1, D2 F: Min. displacement limiter (l)
SAE 3000 SAE 6000 (l) One turn of screw changes
Nominal size pump displacement by approximately
Drain port
2" 1" 1/4 0.24 in3/rev (3.9 cm3/rev)

Dimensions at page 18
› 03/01.2007

Screws tightening torque Nm (lbf in)

V V1
±1 ±13
10 (80 ¸ 97) 130 (1036 ¸ 1266)

12 004 D037-002
Plata 3000

VERSION WITH REAR PORTS - DIMENSIONS LVP 75 - 90

PORTS Optional:
E: Max. displacement limiter (l)
IN OUT
D1, D2 F: Min. displacement limiter (l)
SAE 3000 SAE 6000 (l) One turn of screw changes
Nominal size pump displacement by approximately
Drain port
2" 1" 1/4 0.24 in3/rev (3.9 cm3/rev)

Dimensions at page 18
› 03/01.2007

Screws tightening torque Nm (lbf in)

V V1
±1 ±13
10 (80 ¸ 97) 130 (1036 ¸ 1266)

D037-002 004 13
Plata 3000

DRIVE SHAFTS

SAE “B” SPLINE 04 SAE “B” STRAIGHT 32


Mounting face refer to flange code S5 Mounting face refer to flange code S5

Ext. Involute Spline ANSI B 92.1


with major diameter modified
13 teeth - 16/32 Pitch - 30 deg
Flat Root - Side fit - Class 5

SAE “BB” SPLINE 05 SAE “BB” STRAIGHT 33


Mounting face refer to flange code S5 Mounting face refer to flange code S5

Ext. Involute Spline ANSI B92.1


with major diameter modified
15 teeth - 16/32 Pitch - 30 deg
Flat Root - Side fit - Class 5

SAE “C” SPLINE 06 SAE “C” STRAIGHT 34


Mounting face refer to flange code S7 Mounting face refer to flange code S7 › 03/01.2007

Ext. Involute Spline ANSI B92.1


with major diameter modified
14 teeth - 12/24 Pitch - 30 deg
Flat Root - Side fit - Class 5

14 004 D037-002
Plata 3000

DRIVE SHAFTS

STRAIGHT Ø 22 68 STRAIGHT Ø 25 69
Mounting face refer to flange code Z1 Mounting face refer to flange code Z1

STRAIGHT Ø 32 70
Mounting face refer to flange code Z2
03/01.2007

D037-002 004 15
Plata 3000

MOUNTING FLANGES AND TABLE OF COMPATIBILITY

SAE “B” 2 HOLES S5 SAE “C” 2 HOLES S7


Conforms to SAE J744 Conforms to SAE J744

DRIVE SHAFTS DRIVE SHAFTS


See page 14 See page 14
Pump Pump
type
04 32 05 33 type
06 34

LVP 30 X X LVP 75 X X
LVP 48 X X X LVP 90 X X
X Available combination X Available combination
› 03/01.2007

16 004 D037-002
Plata 3000

MOUNTING FLANGES AND TABLE OF COMPATIBILITY

ISO Ø 100 Z1 ISO Ø 125 Z2


Conforms to ISO 3019/2 Feb88 Conforms to ISO 3019/2 Feb88

DRIVE SHAFTS DRIVE SHAFTS


See page 15 See page 15
Pump Pump
type
68 69 type
70

LVP 30 X LVP 75 X
LVP 48 X LVP 90 X
X Available combination X Available combination
› 03/01.2007

D037-002 004 17
Plata 3000

PORTS SIZES

LOAD SENSING
INLET / OUTLET PORTS DRAIN PORTS
PORT
PORTS Split Split Gas SAE Gas SAE
TYPE SSM SSS BSPP ODT (l) BSPP ODT (l)
Pump type IN OUT IN OUT D1 - D2 D1 - D2 X X

LVP 30 MD QB SD VB GD OB GA 03

LVP 48 ME QC SE VC GD OC GA 03

LVP 75 MF QD SF VD GE OC GA 03

LVP 90 MF QD SF VD GE OC GA 03

(l) Available only with inlet and outlet ports type Split SSS.

Tightening torque for low pressure side port

Tightening torque for high pressure side port [values obtained at 5075 psi (350 bar)]

SAE FLANGED PORTS J518 SSM


Metric thread ISO 60° conforms to ISO/R 262

INLET PORTS - IN (SAE 3000 STANDARD PRESSURE)

A B C D
Nominal
CODE size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
32 58,7 30,2 M 10 20 + 1
MD 1" 1/4 ¾
(1.2598) (2.3110) (1.1890) 28 (1.1024) (177 ¸ 186)
38,1 69,9 35,7 M 12 30 + 2 , 5
ME 1" 1/2 ¾
(1.5000) (2.7520) (1.4055) 26 (1.0236) (266 ¸ 288)
51 77,8 42,9 M 12 30 + 2 , 5
MF 2" ¾
(2.0079) (3.0630) (1.6890) 25 (0.9843) (266 ¸ 288)

OUTLET PORTS - OUT (SAE 6000 HIGH PRESSURE)


› 03/01.2007

A B C D
Nominal
CODE size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
19 50,8 23,8 M 10 45 + 2 , 5
QB 3/4" ¾
(0.7480) (2.0000) (0.9370) 24 (0.9449) (398 ¸ 420)
25,4 57,2 27,8 M 12 70 + 5
QC 1" ¾
(1.0000) (2.2520) (1.0945) 26 (1.0236) (620 ¸ 664)
32 66,7 31,8 M 14 60 + 5
QD 1" 1/4 ¾
(1.2598) (2.6260) (1.2520) 23 (0.9055) (531 ¸ 575)

18 004 D037-003
Plata 3000

PORTS SIZES

Tightening torque for low pressure side port

Tightening torque for high pressure side port [values obtained at 5075 psi (350 bar)]

SAE FLANGED PORTS J518 SSS


American straight thread UNC-UNF 60° conforms to ANSI B 1.1

INLET PORTS - IN (SAE 3000 STANDARD PRESSURE)

A B C D
Nominal
CODE size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
32 58,7 30,2 7/16-14 UNC-2B 25 + 1
SD 1" 1/4 ¾
(1.2598) (2.3110) (1.1890) 28 (1.1024) (221 ¸ 230)
38,1 69,9 35,7 1/2-13 UNC-2B 30 + 2 , 5
SE 1" 1/2 ¾
(1.5000) (2.7520) (1.4055) 26 (1.0236) (266 ¸ 288)
51 77,8 42,9 1/2-13 UNC-2B 30 + 2 , 5
SF 2" ¾
(2.0079) (3.0630) (1.6890) 25 (0.9843) (266 ¸ 288)

OUTLET PORTS - OUT (SAE 6000 HIGH PRESSURE)

A B C D
Nominal
CODE size mm mm mm Thread Nm Nm
(in) (in) (in) Depth mm (in) (lbf in) (lbf in)
19 50,8 23,8 3/8-16 UNC-2B 45 + 2 , 5
VB 3/4" ¾
(0.7480) (2.0000) (0.9370) 24 (0.9449) (398 ¸ 420)
25,4 57,2 27,8 7/16-14 UNC-2B 65 + 5
VC 1" ¾
(1.0000) (2.2520) (1.0945) 20 (0.7874) (575 ¸ 620)
32 66,7 31,8 1/2-13 UNC-2B 60 + 5
VD 1" 1/4 ¾
(1.2598) (2.6260) (1.2520) 23 (0.9055) (531 ¸ 575)
› 03/01.2007

D037-003 004 19
Plata 3000

PORTS SIZES

Tightening torque for low pressure side port

Tightening torque for high pressure side port [values obtained at 5075 psi (350 bar)]

GAS STRAIGHT THREAD PORTS BSPP


British standard pipe parallel (55°) conforms to UNI - ISO 228

Nominal
ÆB ÆC D E
CODE size
A
mm mm mm mm Nm Nm
(in) (in) (in) (in) (lbf in) (lbf in)
8,75 12 35 + 1
GA (X) 1/8" G 1/8 ¾ ¾ ¾
(0.3444) (0.4724) (133 ¸ 142)
36 19 1 20 + 1
GD (l) 1/2" G 1/2 ¾ ¾
(1.4173) (0.7480) (0.0394) (177 ¸ 186)
38 24,5 1 30 + 2 , 5
GE (l) 3/4" G 3/4 ¾ ¾
(1.4961) (0.9646) (0.0394) (266 ¸ 288)
(X) = Load sensing port
(l) = Drain port

SAE STRAIGHT THREAD PORTS J514 ODT


American straight thread UNC-UNF 60° conforms to ANSI B 1.1

Nominal
ÆB ÆC D E
CODE size
A
mm mm mm mm Nm Nm
› 03/01.2007

(in) (in) (in) (in) (lbf in) (lbf in)


9,5 35 + 1
03 (X) 1/4" 7/16" - 20 UNF - 2B ¾ ¾ ¾ ¾
(0.3740) (133 ¸ 142)
33 17,5 1 20 + 1
OB (l) 1/2" 3/4" - 16 UNF - 2B ¾ ¾
(1.2992) (0.6890) (0.0394) (177 ¸ 186)
38 20,5 1 30 + 2 , 5
OC (l) 5/8" 7/8" - 14 UNF - 2B ¾ ¾
(1.4961) (0.8071) (0.0394) (266 ¸ 288)
(X) = Load sensing port
(l) = Drain port

20 004 D037-003
Plata 3000

PRESSURE COMPENSATOR RP

Regulates the pump displacement automatically to equal the flow


requirement of the system while maintaining the pre-adjusted
pressure.

Pressure Standard
Compensator setting range setting
type
psi psi
(bar) (bar)

290 ¸ 5075 4060


RP0
(20 ¸ 350) (280)

OPERATING CURVES

Curves have been obtained at the speed of


1500 min-1and oil temperature 122 °F (50 °C).

RESPONSE TIME

Pump t1 t2
type
› 03/01.2007

ms ms

LVP 30 31 19

LVP 48 44 20
Swashplate

LVP 75 50 25
angle

LVP 90 53 28

D037-004 004 21
Plata 3000

MOUNTING POSITIONS AND DIMENSIONS (pressure compensator) RP

Side ports

Anti-clockwise rotation Clockwise rotation

Rear ports

Anti-clockwise rotation Clockwise rotation

› 03/01.2007

Pump A
type
mm (in)

LVP 30 114 (4.488)

LVP 48 123 (4.843)

LVP 75 136 (5.354)

LVP 90 136 (5.354)

NOTES: For different mounting positions, please consult our sales department.

22 004 D037-004
Plata 3000

FLOW COMPENSATOR (Load-sensing) LS

LS0 - LS2 Hydraulic circuits


Regulates the pump displacement to maintain a constant (load
independent) pressure drop across a flow metering device. In
the standard version the flow compensator is combined with
pressure compensator.

Differential
Standard
Flow pressure
Pressure setting
compensator setting range
type compensator
psi psi
(bar) (bar)

LS0
145 ¸ 580 203
LS2 (u) RP0
(10 ¸ 40) (14)
LS3 (l)
(u): For remote control Y is plugged.
(l): For internal control and remote pressure control.

Pilot flow » 0.34 ¸ 0.40 US gpm (1,3 ¸ 1,5 l/min)

In standard setting conditions 203 psi (14 bar) the stand-by pres-
sure is 232± 29 psi (16± 2 bar).

LS3 Hydraulic circuits


OPERATING CURVES

Curves have been obtained at the speed of


1500 min-1and oil temperature 122 °F (50 °C).
› 03/01.2007

Curve at variable speed TECHNICAL DATA

Pump DQ max
type
US gpm (l/min)

LVP 30 0.24 (0,9)

LVP 48 0.45 (1,7)

LVP 75 0.66 (2,5)

LVP 90 0.66 (2,5)

D037-004 004 23
Plata 3000

MOUNTING POSITIONS AND DIMENSIONS (flow compensator) LS

Side ports

Anti-clockwise rotation Clockwise rotation

Rear ports

Anti-clockwise rotation Clockwise rotation

› 03/01.2007

Pump A B
type
mm (in) mm (in)

LVP 30 144 (5.669) 100 (3.937)

LVP 48 153 (6.024) 109 (4.291)

LVP 75 165 (6.496) 122 (4.803)

LVP 90 165 (6.496) 122 (4.803)

X: Load sensing port. Dimension on page 18

NOTES: For different mounting positions, please consult our sales department.

24 004 D037-004
Plata 3000

TORQUE LIMITER RN

Regulates the pump displacement according to the system pres-


RN0 - Standard
sure, to maintain the pre-adjusted torque value and protect the
prime mover from overload. To have the best torque limiter regula-
tion, the pre-adjusted absorbed torque has to be higher than the
value shown in the following table.

Pump type LVP 30 LVP 48 LVP 75 LVP 90

Min. torque lbf in 381 602 1000 1168


(Nm) (43) (68) (113) (132)
Min. power HP 9 14.3 23.9 27.7
(at 1500 min -1 ) (kW) (6,7) (10,7) (17,8) (20,7)

For lower torque setting values, the regulator limits the maximum
working pressure to a value lower than the standard setting for the
pressure regulator [4060 psi (280 bar)].

When ordering the torque limiter please specify the requested


value of torque [eg. 620 lbf in (70 Nm)] or the requested power
[eg. 13.4 HP (10 kW) at 1500 min-1].

RN1 - Inernal pilot

OPERATING CURVES

This curve has been obtained at the speed of 1500 min-1 and oil
temperature 122 °F (50 °C).

Tehoretical
power
› 03/01.2007

D037-004 004 25
Plata 3000

MOUNTING POSITIONS AND DIMENSIONS (torque limiter) RN

Side ports

Anti-clockwise rotation Clockwise rotation

Pump A B C D
› 03/01.2007

type
mm (in) mm (in) mm (in) mm (in)

LVP 30 144 (5.669) 100 (3.937) 104 (4.094) 211 (8.307)

LVP 48 153 (6.024) 109 (4.291) 111 (4.370) 235 (9.252)

LVP 75 165 (6.496) 122 (4.803) 120 (4.724) 258 (10.157)

LVP 90 165 (6.496) 122 (4.803) 120 (4.724) 258 (10.157)

X: Load sensing port. Dimension on page 18

NOTES: For different mounting positions, please consult our sales department.

26 004 D037-004
Plata 3000

MOUNTING POSITIONS AND DIMENSIONS (torque limiter) RN

Rear ports

Anti-clockwise rotation Clockwise rotation

Pump A B C D
› 03/01.2007

type
mm (in) mm (in) mm (in) mm (in)

LVP 30 144 (5.669) 100 (3.937) 104 (4.094) 211 (8.307)

LVP 48 153 (6.024) 109 (4.291) 111 (4.370) 235 (9.252)

LVP 75 165 (6.496) 122 (4.803) 120 (4.724) 258 (10.157)

LVP 90 165 (6.496) 122 (4.803) 120 (4.724) 258 (10.157)

X: Load sensing port. Dimension on page 18

NOTES: For different mounting positions, please consult our sales department.

D037-004 004 27
Plata 3000

UNLOADING VALVE U ..

NC (normally closed) NA (normally open)

With the valve NC type (normally closed), energi- With the valve NA type (normally open), energi-
zing the solenoid valve the displacement is reset zing the solenoid valve the pump is sent to the
and the pump is unloaded. maximum displacement.

Notes
Unloading valve can be supplied only with
pressure compensator RP.

Voltages available

Regulator
Arrangement Volt
type

U1 NC 12 V D.C.

U2 NC 24 V D.C.
› 03/01.2007

U3 NC 24 V A.C.

U6 NA 12 V D.C.

U7 NA 24 V D.C.

U8 NA 24 V A.C.

28 004 D037-004
Plata 3000

DIGITAL INTEGRATED DRIVERS DES..

New digital drivers, integrated to the pump, realize combined


DES Hydraulic circuits
closed loop controls of pressure, flow and maximum power limi-
tation. These controls provide fast dynamics and fine regula-
tions directly commanded from PC or from the machine control-
ler. They are also available with an optional sequence module
that allows the circuit to operate with minimum pressure (close
to zero). A remote pressure transducer must be installed on the
system and its feedback has to be interfaced to the pump digital
driver. If the real pressure value in the system (measured by the
pressure transducer) remains below the respective reference
signal provided by the machine controller, the digital driver re-
gulates in closed loop the pump swash plate position according
to the flow reference signal. When the real pressure becomes
close to the respective reference signal, the driver automatically
perfoms the closed loop control of the pressure.
The digital control ensures high performance regulating flow
and pressure linearity, better flow knee and internal leakage
compensation.

DESR Hydraulic circuits

DES Basic version, without sequence module and without


pressure transducer which has to be installed on the
outlet line and wired to the 12 poles connectors of the
integral digital electronics.

DESR Version with sequence module RES which grant a mi-


nimum piloting pressure [261 psi (18 bar)] when the
actual pressure falls below that value. Without
pressure transducer.

Technical data for digital electronic drivers

Driver section

Format Sealed box on the valve - Protection: IP67 DIN 40050 - Insulation: VDE0110
Electromagnetic compatibility (EMC) Emission: EN 50081-2 - Immunity: EN 50082-2
Max power consumption 0.07 HP (50 W)
Current supplied to solenoid Imax = 3,3 A square wave PWM type
› 03/01.2007

Analog input signal impedance Voltage signal Ri > 50 KW


Operating temperature -4 °F ¸ +140 °F (-20 °C ¸ +60 °C) [storage -4 °F ¸ +158 °F (-20 °C ¸ +70 °C)]
Alarm messages Electronic overcurrent and overtemperature
Pressure control by P.I.D. - Rapid solenoid excitation and switching off - Output to
Features solenoids protected against accidental short circuits - Feedback cable break produ-
ces an inhibition of the driver, zeroing the current to the solenoid

Note

For functional parameters of the digital valves as the bias, scale, ramp and linearization of the regulation characteristic, please
consult our sales department.

D037-004 004 29
Plata 3000

MOUNTING POSITIONS AND DIMENSIONS (digital integrated drivers) DES

Side ports

Clockwise rotation

For anti-clockwise rotation, please consult our sales department.

Pump A B C D
type
mm (in) mm (in) mm (in) mm (in)

LVP 30 146,5 (5.7677) 246 (9.6850) 103,5 (4.0748) 253 (9.9606)

LVP 48 153 (6.0236) 246 (9.6850) 103,5 (4.0748) 262 (10.3150)

LVP 75 161,5 (6.3583) 246 (9.6850) 103,5 (4.0748) 274,5 (10.8071)

LVP 90 161,5 (6.3583) 246 (9.6850) 103,5 (4.0748) 274,5 (10.8071)


› 03/01.2007

NOTES: For different mounting positions, please consult our sales department.

30 004 D037-004
Plata 3000

MOUNTING POSITIONS AND DIMENSIONS (digital integrated drivers) DESR

Side ports

Clockwise rotation

For anti-clockwise rotation, please consult our sales department.

Pump A B C D E
type
mm (in) mm (in) mm (in) mm (in) mm (in)

LVP 30 146,5 (5.7677) 246 (9.6850) 103,5 (4.0748) 253 (9.9606) 262,5 (10.3346)

LVP 48 153 (6.0236) 246 (9.6850) 103,5 (4.0748) 262 (10.3150) 299 (11.7717)

LVP 75 161,5 (6.3583) 246 (9.6850) 103,5 (4.0748) 274,5 (10.8071) 337 (13.2677)

LVP 90 161,5 (6.3583) 246 (9.6850) 103,5 (4.0748) 274,5 (10.8071) 337 (13.2677)
› 03/01.2007

NOTES: For different mounting positions, please consult our sales department.

D037-004 004 31
Plata 3000

MULTIPLE PUMPS

Through drive
PLATA 3000 through drive axial piston pumps offer the flexibility to obtain different groups able to supply several hydraulic systems.
The operating characteristics of each assembled pumps are the same as the corresponding single pumps according to the following
conditions:
1) Do not exceed the maximum transmissible torque.
2) The maximum rotational speed is that of the lowest rated speed of the single unit incorporated.

M lbf in (Nm) Torque


V 3 3
in /rev (cm /rev) Displacement Dp • V
M= [Nm]
62,83• h m
Dp psi (bar) Pressure

hm= hm (V,Dp, n) Mechanical efficiency

Note: The torque absorbed from the shaft of the first pump results from the sum of the torques due to all single stages.
The achieved value must not exceed the maximum torque limit given for the shaft of the first pump.

A B (l) C D E
Pump
type mm mm Flanged mm mm mm
Code
(in) (in) for (in) (in) (in)
145 77 SAE A AS1 213 183 222
LVP 30 (5.709) (3.031) SAE B AS5 (8.386) (7.205) (8.740)
169 82 SAE A AS1 242 206 251
LVP 48
› 03/01.2007

(6.654) (3.228) SAE B AS5 (9.528) (8.110) (9.882)


99 SAE A AS1 291
192 (3.898) SAE B AS5 276 235 (11.445)
LVP 75 (7.559) 104 (10.866) (9.252) 296
SAE C AS7
(4.094) (11.654)
99 SAE A AS1 291
192 (3.898) SAE B AS5 276 235 (11.445)
LVP 90 (7.559) 104 (10.866) (9.252) 296
SAE C AS7
(4.094) (11.654)

Overall dimensions: the same as the single pumps.


Ports dimensions on page 18. - Screws are supplied with the first pump.
(l) Cover kit are available to obtain single pumps starting from front sections of multiple pumps. Dimensions on page 40.

32 004 D037-005
Plata 3000

INTERMEDIATE FLANGES LVP 30

SAE “A” 2 HOLES AS1


SAE J744 Jul88

COUPLINGS LVP 30

SAE “A” SPLINE 03


Available with flange code AS1

ANSI B 92.1a-1976
class 6 - 9 teeth
16/32 D.P. - ang=30°
flat root - side fit
Second pump side

MAX 100 Nm (885 lbf in)

SAE “A” STRAIGHT 31


Available with flange code AS1
03/01.2007

SAE “A” Straight

Second pump side

MAX 60 Nm (531 lbf in)

D037-005 004 33
Plata 3000

INTERMEDIATE FLANGES LVP 30

SAE “B” 2 HOLES AS5


SAE J744 Jul88

COUPLINGS LVP 30

SAE “B” SPLINE 04


Available with flange code AS5

ANSI B 92.1a-1976
class 6 - 13 teeth
16/32 D.P. - ang=30°
flat root - side fit
Second pump side

MAX 135 Nm (1195 lbf in)

SAE “B” STRAIGHT 32


Available with flange code AS5
03/01.2007

SAE “B” Straight

Second pump side

MAX 145 Nm (1283 lbf in)

34 004 D037-005
Plata 3000

INTERMEDIATE FLANGES LVP 48

SAE “A” 2 HOLES AS1


SAE J744 Jul88

COUPLINGS LVP 48

SAE “A” SPLINE 03


Available with flange code AS1

ANSI B 92.1a-1976
class 6 - 9 teeth
16/32 D.P. - ang=30°
flat root - side fit
Second pump side

MAX 135 Nm (1195 lbf in)

SAE “A” STRAIGHT 31


Available with flange code AS1
03/01.2007

SAE “A” Straight

Second pump side

MAX 60 Nm (531 lbf in)

D037-005 004 35
Plata 3000

INTERMEDIATE FLANGES LVP 48

SAE “B” 2 HOLES AS5


SAE J744 Jul88

COUPLINGS LVP 48

SAE “B” SPLINE 04 SAE “BB” SPLINE 05


Available with flange code AS5 Available with flange code AS5

ANSI B 92.1a-1976 ANSI B 92.1a-1976


class 6 - 13 teeth class 6 - 15 teeth
16/32 D.P. - ang=30° 16/32 D.P. - ang=30°
flat root - side fit flat root - side fit
Second pump side Second pump side

MAX 250 Nm (2213 lbf in) MAX 250 Nm (2213 lbf in)

SAE “B” STRAIGHT 32 SAE “BB” STRAIGHT 33


Available with flange code AS5 Available with flange code AS5
03/01.2007

SAE “B” Straight SAE “BB” Straight


MAX 145 Nm (1283 lbf in) Second pump side MAX 240 Nm (2124 lbf in) Second pump side

36 004 D037-005
Plata 3000

INTERMEDIATE FLANGES LVP 75 - 90

SAE “A” 2 HOLES AS1


SAE J744 Jul88

COUPLINGS LVP 75 - 90

SAE “A” SPLINE 03


Available with flange code AS1

ANSI B 92.1a-1976
class 6 - 9 teeth
16/32 D.P. - ang=30°
flat root - side fit
Second pump side

MAX 135 Nm (1195 lbf in)

SAE “A” STRAIGHT 31


Available with flange code AS1
› 03/01.2007

SAE “A” Straight

Second pump side

MAX 60 Nm (531 lbf in)

D037-005 004 37
Plata 3000

INTERMEDIATE FLANGES LVP 75 - 90

SAE “B” 2 HOLES AS5


SAE J744 Jul88

COUPLINGS LVP 75 - 90

SAE “B” SPLINE 04 SAE “BB” SPLINE 05


Available with flange code AS5 Available with flange code AS5

ANSI B 92.1a-1976 ANSI B 92.1a-1976


class 6 - 13 teeth class 6 - 15 teeth
16/32 D.P. - ang=30° 16/32 D.P. - ang=30°
flat root - side fit flat root - side fit
Second pump side Second pump side

MAX 330 Nm (2921 lbf in) MAX 400 Nm (3540 lbf in)

SAE “B” STRAIGHT 32 SAE “BB” STRAIGHT 33


Available with flange code AS5 Available with flange code AS5
› 03/01.2007

SAE “B” Straight SAE “BB” Straight


MAX 145 Nm (1283 lbf in) MAX 240 Nm (2124 lbf in)
Second pump side Second pump side

38 004 D037-005
Plata 3000

INTERMEDIATE FLANGES LVP 75 - 90

SAE “C” 2 HOLES AS7


SAE J744 Jul88

COUPLINGS LVP 75 - 90
SAE “C” SPLINE 06
Available with flange code AS7

ANSI B 92.1a-1976
class 6 - 14 teeth
12/24 D.P. - ang=30°
flat root - side fit
Second pump side

MAX 440 Nm (3894 lbf in)

SAE “C” STRAIGHT 34


Available with flange code AS7
› 03/01.2007

SAE “C” Straight

Second pump side

MAX 495 Nm (4381 lbf in)

D037-005 004 39
Plata 3000

FRONT SECTION KIT COVER

Cover kit is available to obtain single pumps starting from the front sections of multiple pumps. Before closing the intermediate flange
check that the couplig has been removed.

1 2 3
Kit part break down

1 - Seal
2 - Flange
3 - Screws

V1

Screws tightening torque Nm (lbf in)

V
V1
LVP 30 LVP 48 LVP 75 - LVP 90
±7 ±10 ±13 ±1
70 (558 ¸ 682) 100 (797 ¸ 974) 130 (1036 ¸ 1266) 20 (159 ¸ 195)

Pump A B D F
type
mm (in) mm (in) Flanged for Code mm (in) mm (in) Kit code
› 03/01.2007

SAE A AS1 13,4 (0.5276) 62082200


LVP 30 145 (5.709) 77 (3.031) 183 (7.205)
SAE B AS5 14,5 (0.5709) 62082300
SAE A AS1 13,4 (0.5276) 62082200
LVP 48 169 (6.654) 82 (3.228) 206 (8.110)
SAE B AS5 14,5 (0.5709) 62082300
SAE A AS1 13,4 (0.5276) 62082200
99 (3.898)
LVP 75 192 (7.559) SAE B AS5 235 (9.252) 14,5 (0.5709) 62082300
104 (4.094) SAE C AS7 17 (0.6693) 62082400
SAE A AS1 13,4 (0.5276) 62082200
99 (3.898)
LVP 90 192 (7.559) SAE B AS5 235 (9.252) 14,5 (0.5709) 62082300
104 (4.094) SAE C AS7 17 (0.6693) 62082400

Overall dimensions: the same as the single pumps.


Ports dimensions on page 18.

40 004 D037-005
Plata 3000

HOW TO ORDER SINGLE PUMPS

1 2 3 4 5 6 7 8 9 10
Drive Mounting Ports Ports Additional
Pump type Rotation – shaft flange
– position IN/OUT
– Seals – Regulators – options
Fluid

LVP 30 S – 04 S5 – L MD/QB – N – RP0 – E ...

1 Pump type (max displacement) CODE Seals 7


CODE
in3/rev cm3/rev N Buna (standard)
1.74 29 LVP 30 V Viton
2.76 46 LVP 48
4.38 73 LVP 75 CODE Regulators 8
5.36 87,9 LVP 90 Pressure compensator - setting range
RP0 290 - 5075 psi (20 - 350 bar) (a)
2 Rotation CODE LS0 Flow compensator (b)
LS2 Flow compensator for remote control (b)
Anti-clockwise S
LS3 Flow compensator for internal control (b)
Clockwise D
RN0 Torque limiter - standard
RN1 Torque limiter - internal pilot
3 Drive shaft CODE
DES Pressure and flow digital regulator (c)
SAE “B” spline (13 teeth) 04 Pressure and flow digital regulator
SAE “B” straight 32 DESR with sequence module RES (c)
Straight Æ 22 68
SAE “BB” spline (15teeth) 05 CODE Additional options (d) 9
SAE “BB” straight 33 Without additional options (no code)
Straight Æ 25 69 E Max. displacement limiter (e)
SAE “C” spline (14 teeth) 06 F Min. displacement limiter (e)
SAE “C” straight 34 G Min. and max. displacement limiter (e)
Straight Æ 32 70 U.. Unloading valve (f)

4 Mounting flange CODE CODE Fluid 10


SAE “B” 2 holes S5 Mineral oil (no code)
ISO Æ 100 Z1 HF fire resistant fluid
SAE “C” 2 holes S7 H (please consult our sales department)
ISO Æ 125 Z2
a) Standard setting 4060 psi (280 bar).
5 Ports position CODE
b) Differential pressure standard setting 203 psi
Side L
(14 bar) - Setting range 145 - 580 psi (10 - 40 bar).
Rear P
c) For more informations, please consult our sales
6 Inlet/outlet ports CODE department.
d) For additional options, please consult our sales
SAE FLANGED PORTS METRIC THREAD (SSM) department.
Nominal size
Pump type Inlet IN Outlet OUT e) Max. up to 50% of the displacement.
SAE 3000 SAE 6000 f) For voltages availability please see page 28.
LVP 30 1"1/4 3/4" MD/QB
› 03/01.2007

LVP 48 1"1/2 1" ME/QC


LVP 75 2" 1"1/4 MF/QD
LVP 90 2" 1"1/4 MF/QD
SAE FLANGED PORTS UNC THREAD (SSS)
Nominal size
Pump type Inlet IN Outlet OUT
SAE 3000 SAE 6000
LVP 30 1"1/4 3/4" SD/VB
LVP 48 1"1/2 1" SE/VC
LVP 75 2" 1"1/4 SF/VD
LVP 90 2" 1"1/4 SF/VD

D037-007 004 41
Plata 3000

HOW TO ORDER MULTIPLE PUMPS

1 2 3 4 5 6 7 8 9 10 11 12
Pump Rota- Drive Mounting Ports Ports Regula- Addition. Interm. Cou-
type tion – shaft flange
– position IN/OUT
– Seals – tors
– options Fluid – flange pling

LVP 30 S* – 04 S5 – L MF/QD – N# – RP0 – E ... – AS5 04 /


Front section

LVP 30 S# – 04 S5 – L MD/QB – N – LS2 – E ...


Rear section

1 Pump type (max displacement) CODE Seals 7


3 3
CODE
in /rev cm /rev N Buna (standard)
1.74 29 LVP 30 V Viton
2.76 46 LVP 48
4.38 73 LVP 75 CODE Regulators 8
5.36 87,9 LVP 90 Pressure compensator - setting range
RP0 290 - 5075 psi (20 - 350 bar) (b)
2 Rotation CODE LS0 Flow compensator (c)
LS2 Flow compensator for remote control (c)
Anti-clockwise S
LS3 Flow compensator for internal control (c)
Clockwise D
RN0 Torque limiter - standard
RN1 Torque limiter - internal pilot
3 Drive shaft CODE
DES Pressure and flow digital regulator (d)
SAE “B” spline (13 teeth) 04 Pressure and flow digital regulator
SAE “B” straight 32 DESR with sequence module RES (d)
Straight Æ 22 68
SAE “BB” spline (15teeth) 05 CODE Additional options (e) 9
SAE “BB” straight 33 Without additional options (no code)
Straight Æ 25 69 E Max. displacement limiter (f-g)
SAE “C” spline (14 teeth) 06 F Min. displacement limiter (f-g)
SAE “C” straight 34 G Min. and max. displacement limiter (f-g)
Straight Æ 32 70 U.. Unloading valve (h)

4 Mounting flange CODE CODE Fluid 10


SAE “B” 2 holes S5 ... Mineral oil (no code)
ISO Æ 100 Z1 HF fire resistant fluid
SAE “C” 2 holes S7 H (please consult our sales department)
ISO Æ 125 Z2
CODE Intermediate flange 11
5 Ports position CODE AS1 SAE “A” 2 holes
Side L AS5 SAE “B” 2 holes
Rear (a) P AS7 SAE “C” 2 holes

6 Inlet/outlet ports CODE CODE Coupling 12


SAE FLANGED PORTS METRIC THREAD (SSM) 03 SAE “A” spline (9 teeth)
31 SAE “A” straight
Nominal size
Pump type Inlet IN Outlet OUT 04 SAE “B” spline (13 teeth)
SAE 3000 SAE 6000 32 SAE “B” straight
LVP 30 1"1/4 3/4" MD/QB 05 SAE “BB” spline (15 teeth)
LVP 48 1"1/2 1" ME/QC 33 SAE “BB” straight
LVP 75 2" 1"1/4 MF/QD 06 SAE “C” spline (14 teeth)
› 03/01.2007

LVP 90 2" 1"1/4 MF/QD 34 SAE “C” straight


SAE FLANGED PORTS UNC THREAD (SSS) a) Not available for front sections.
Nominal size b) Standard setting 4060 psi (280 bar).
Pump type Inlet IN Outlet OUT
SAE 3000 SAE 6000 c) Differential pressure standard setting 203 psi
LVP 30 1"1/4 3/4" SD/VB (14 bar) - Setting range 145 - 580 psi (10 - 40 bar).
LVP 48 1"1/2 1" SE/VC d) For more informations, please consult our sales
LVP 75 2" 1"1/4 SF/VD department.
LVP 90 2" 1"1/4 SF/VD e) For additional options, please consult our sales
department.
* For multiple pumps, the rotation code letter is added f) Max. up to 50% of the displacement.
at the end of the complete ordering code.
g) LVP30 con flangia AS5, LVP75 e LVP90 con
# Omit code only if ordering assembled multiple flangia AS7 non sono disponibili.
pumps.
h) For voltages availability please see page 28.

42 004 D037-007
Plata 3000

ORDER EXAMPLE

SINGLE PUMPS

Standard pump LVP 30 S-04 S5-L MD/QB-N-LS2

Pump with special features LVP 30 S-04 S5-L MD/QB-N-LS2-E H

ASSEMBLED MULTIPLE PUMPS

Standard double pump LVP 30-04 S5-L MD/QB-RP0-AS5 04 / 30-04 S5-L MD/QB-N-LS2 S

Double pump with special features LVP 75-06 S7-L MF/QD-RP0-E H-AS5 04 / 30-04 S5-L MD/QB-N-LS2 S

Double pump with different series pumps LVP 30-04 S5-L MD/QB-RP0-E-AS1 03 / PLP20.4-03 S1-L EA/EA-N S

INDIVIDUAL SECTIONS

Front section LVP 30 S-04 S5-L MD/QB-N-RP0-AS5 04

Rear section LVP 30 S-04 S5-L MD/QB-N-LS2


03/01.2007

Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed
without notice.

D037-007 004 43
Casappa:
Fluid Power Design
at 360°
Gear pumps.
High performace, low noise.

Variable displacement axial piston pumps,


for open circuit.

Fixed displacement bent axis piston pumps,


for truck applications.

Cast iron gear pumps and


motors of three part construction.

Cast iron gear pumps,


for truck applications.

Cast iron gear pumps and


motors of two part construction.

Gear pumps and


motors in aluminium.

Double acting hydraulic hand pumps


with or without reservoir.

Filters : suction filters, return filters, in line filters spin-on


type, for medium and high pressure filters.

CASAPPA S.p.A. - Parma - Italy - Tel.: + 39 0521 304111 - Fax: + 39 0521 804600
CASAPPA Corp. - Batavia, IL 60510 U.S.A. - Phone: 630 761-0041 - Fax: 630 761-0048
CASAPPA GmbH - Plüderhausen - Germany - Tel.: + 49 (0)7181 989830 - Fax: + 49 (0)7181 989831
CASAPPA SARL - La Rochelle - France - Tel.: + 33 (0)5 46372433 - Fax: + 33 (0)5 46423907
www.casappa.com
e-mail: info@casappa.com