1. Introduction
The official authorised VDO Common Rail pump service solution is based on the Hartridge AVM2-PC with HB378
Universal CR Base Kit, HF1130 All Makes Common Rail Pump Test Kit, HF1134 VDO Common Rail Pump Kit
and HF1136 VDO Common Rail Pump Kit (Upgrade), HF1155 APB309 Upgrade Kit for VDO 5WS40565 (If
required) and the HF1158 VDO CR Pump Supplementary Kit (LION) fitted to the test bench.
The pumps that are now covered as part of the official authorised VDO Common Rail pump service solution are:
Please Note: - The example test plans issued in TIB195/07 are not part of the official authorised VDO Common
Rail pump service solution.
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 1 of 8
Each pump requires specific Hartridge tooling which is detailed below in the Pump fitting section; each pump
must be fitted in accordance with this.
2. Pump Fitting
New parts added are in Bold
DV4TD_5WS40008
VDO Configuration
3 4
DW10TD_5WS40018
VDO Configuration
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 2 of 8
DW10B_5WS40019
VDO Configuration
3
4
1 Mounting APB316 Mounting Plate
ADC298
Service Drive Unit
2 Coupling X39-800-300-
Tang Drive Plate
031Z
3 Supply ALP323 10mm QR Adaptor
NGD 3.0_5WS40064
VDO Configuration
3 4
1 Mounting APB250/1 Mounting Plate
LYNX_5WS40094
VDO Configuration
3
Mounting Plate
5 1 Mounting APB299
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 3 of 8
K9K_EU4_5WS40153
VDO Configuration
4
LION V6_5WS40157
VDO Configuration
3 4
ADC298
Service Drive Unit
2 Coupling X39-800-300-
Tang Drive Plate
031Z
3 Supply ALP334 QR Adaptor
5
7 Cable A086E950 Pump Cable – VDO 1
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 4 of 8
LION V8_5WS40254
VDO Configuration
4
5 APB242 Mounting Plate
1 Mounting
APB250/3 50mm Spigot Adaptor
6 ADC307 Coupling
+ +
2 Coupling ADC312 Bolt
+ +
ADC313 Spacer
3 Supply ALP323 10mm QR Adaptor
LION V6 UG_5WS40273
VDO Configuration
5
K9K_EU5_5WS40565
VDO Configuration
6
5
7 Cable A086E950 Pump Cable – VDO 1
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 5 of 8
PUMA_5WS40694
VDO Configuration
3 5
1 Mounting APB349 Mounting Plate
4
ADC298 Service Drive Unit
2 Coupling + +
ADC300 Tang Drive Plate
3 Supply ALP323 10mm QR Adaptor
3 5
1 Mounting APB250_1 Mounting Plate
ADC307 Coupling
+ +
2 Coupling ADC312 Bolt
4
+ +
ADC313 Spacer
3 Supply ALP323 10mm QR Adaptor
6 - - (None)
SPRINT_5WS40905
VDO Configuration
3
5
1 Mounting APB250_1 Mounting Plate
ADC307 Coupling
+ +
2 Coupling ADC312 Bolt
4
+ +
ADC313 Spacer
3 Supply ALP323 10mm QR Adaptor
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 6 of 8
VW_5WS40836 & 5WS40891
VDO Configuration
3
7 1 Mounting APB325_2 Mounting Plate
5
6 - - (None)
Pump Cable – VDO 1
7 Cable A086E950
(FCV/VCV only)
Drive Direction R (CW) – viewed from pump drive end
Screws Pump to plate: 3 off M8x35
DV6C_5WS40893
VDO Configuration
FP383 Coupling
4 + +
2 Coupling ADC312 Bolt
+ +
ADC313 Spacer
ALP365 Port Extension (10mm Hose)
3 3 Supply + +
ALP307 8mm QR Adaptor
4 Return ALP307 8mm QR Adaptor
6 - - (None)
DV6C_5WS40894
VDO Configuration
FP383 Coupling
+ +
2 Coupling ADC312 Bolt
+ +
ADC313 Spacer
3 Supply ALP323 10mm QR Adaptor
6 - - (None)
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 7 of 8
3. Technical Information for Testing
AVM2-PC – Fuel Pressure Valve Operation
It is essential that the AVM2-PC Fuel Pressure Supply Valve is capable of maintaining a vacuum.
Prior to testing a VDO Common Rail pump the operation of the AVM2-PC Fuel Pressure Supply Valve must be
checked, using the following method (It is advised that personal protective clothing is worn): -
1. Close fuel pressure valve fully on AVM2-PC facia.
2. Fit ALP323 to the supply hose quick release connector.
3. Ensure that the exit of ALP323 is pointing into the drain area of the AVM2-PC test bench away from the
operator.
4. Turn the fuel on.
5. Monitor the fuel out of the supply pipe through ALP323 no oil should flow.
6. Open fuel pressure valve slowly (max 2 turns) on the AVM2-PC facia check for flow of fuel through
ALP323.
7. Close valve fully and check the fuel flow through ALP323 stops.
8. Turn fuel off.
If the fuel passes through ALP323 when the AVM2-PC valve is fully shut off it is defective and you should contact
your local distributor.
The installation angle of for the each VDO Common Rail pump is very important, each pump must be installed
with cylinder 1 uppermost as shown in the diagram above. In most cases cylinder 1 is located next to PCV
electrical connection / pump return.
TIB 196/6 Issue 8, June 2018 (AT3531) © Hartridge Ltd., 2018 Page 8 of 8