1) INTRODUCTION:
The thermal behavior during Isomerization Reaction was studied in a reaction
calorimeter for Mangalam Organics Limited., Mumbai.
2) EXPERIMENTAL:
i) RC1:
Mettler make AP 01 500 ml capacity all glass reactor equipped with a pitch blade
type down flow agitator, jacketed with controlled temperature circulator, addition
funnel, condenser and the probes.
ii) Experiment:
1) 200 gm of freshly distilled Alpha pinene and 1.2 gm of Activated Catalyst charged to
the reactor at RT.
2) Then Reaction Mass was heated at 50°C.
3) Then Reaction Mass was heated at 155°C
4) Then Reaction Mass was maintained for 120 minutes.
Contd….2
These results are valid only for the sample tested. The test results reported are valid under the stated conditions of
measurements. This report may not be reproduced, except in full. Any correction invalidates this report
Intertek India Pvt. Ltd.
Safety Testing Laboratory
nd
F Wing, 2 Floor, Tex Centre,
Chandivali Farm Road, Off saki
vihar road, Andheri (East),
Mumbai 400 072
Tel. +9122 42450203 / 206
4) HEAT OF REACTION:
a. The overall heat evolved during maintaining for 120 minutes is 37.224 KJ
(exotherm) for 0.201 Kg of reaction mass i.e 185.194 KJ/Kg of
reaction mass.
Contd….3
These results are valid only for the sample tested. The test results reported are valid under the stated conditions of
measurements. This report may not be reproduced, except in full. Any correction invalidates this report
Intertek India Pvt. Ltd.
Safety Testing Laboratory
nd
F Wing, 2 Floor, Tex Centre,
Chandivali Farm Road, Off saki
vihar road, Andheri (East),
Mumbai 400 072
Tel. +9122 42450203 / 206
5) CONCLUSION:
ii) The Maximum Heat Generation Rate during maintaining for 120 minutes
is 132.94 W/Kg of reaction mass. The Maximum Temperature Synthesis
of Reaction (MTSR) during maintaining for 120 minutes is 276°C.
These results are valid only for the sample tested. The test results reported are valid under the stated conditions of
measurements. This report may not be reproduced, except in full. Any correction invalidates this report
Intertek India Pvt. Ltd.
Safety Testing Laboratory
nd
F Wing, 2 Floor, Tex Centre,
Chandivali Farm Road, Off saki
vihar road, Andheri (East),
Mumbai 400 072
Tel. +9122 42450203 / 206
7) COMMENTS:
Authorized Signatory
Mr. Avinash Kamble
Technical Manager
Safety Testing Laboratory
Prepared & Checked Intertek India
These results are valid only for the sample tested. The test results reported are valid under the stated conditions of
measurements. This report may not be reproduced, except in full. Any correction invalidates this report
Annexure-I
Experiment: Mangalam- Isomerization Reaction
Started: November 15, 2018 12:06 Author: INTERTEKCP-RC1\admin
1 Chemistry
2 Setup
RC1e Description
Device RC1e
Reactor AP01-0.5-3w Glass
Cover Cover PTFE AP01-0.5
Stirrer Pitch blade down
Calibration Heater Cal. heater, 5 W
Tr sensor Tr
RD10 Description
Name : Dist Set
Output : V1
Distillation FCE ID : Reflux divider
Set Temp. Diff. : Temp. Difference sensor on A2
Vapor Temp : Pt100 on A1
3 Calorimetric Calculations
Integral Results
Start End
Trend Name Integral Baseline Type ∆Tad
Time Time
qr_hf Maintained for 2hrs. 01:54:29 03:59:28 37.224 kJ Proportional To Conversion 121.13 K
Various Parameters
qr definition qr_hf = qflow_hf - qc + qaccu + qdos
qdos averaged yes
cpi at 200 ml 12.31 J/K
cpi at 500 ml 23.25 J/K
Reactor Time Constant 15 s
∆Tad calculation Use mr and cpr at the end of the integral