Sei sulla pagina 1di 1


Laboratorium Pengujian

CERTIFICATE OF ANALYSIS
Correspondence Reference Number 36-2017
Manufacture Date May, 2017
Product Name Portland Composite Cement
Desa Baruga
NRP 201-019-090567
Kecamatan Standard Requirements SNI 7064 : 2014
Bantimurung
Test Parameter Unit Requirements Results
Maros 90561
Sulfur trioxide, SO3 % Max 4.0 1.62
SulSel Fineness, Air Permeability Test m2/kg Min 280 420
Autoclave expansion % Max 0.80 0.11
Time of setting, Vicat test :
Telephone - Initial set minutes Min 45 151
- Final set minutes Max 375 265
0 800 1 805034 Compressive strength :
- 3 days kg/cm2 Min 130 176
- 7 days kg/cm2 Min 200 235
- 28 days kg/cm2 Min 280 326
False set, final penetration % Min 50 84.62
Air content of mortar % volume Max 12 2.75
Note :
Specific gravity 3.05 g/cm3
Facimile Approval by,

0411-372234

-------------------------------------
Andi Asman Setiawan
E-mail QA & QC Division Head
Sample reported June, 14th 2017
customercare@
semenbosowa. The above results relate only to the items tested. This reports shall not be reproduced, without the written
approval by Quality Assurance & Quality Control Division Head.
co.id