Sei sulla pagina 1di 1

ELEVACION FRONTAL DE LA ESTRUCTURA ARMADO DE ACERO EN LA ESTRUCTURA

CAPUCHON DE VENTEO COLUMNA


F´c = 210 kg/cm2

ARMADO DE ACERO DE LOSA MACIZA


.40 2.20 .40
NIV. PARADA

1.00
2Ø5/8 2Ø5/8
FILTRO DE ESCALERA

PLANO DE TANQUE ELEVADO Y

.30

.30
SEDIMENTOS DE GATO

NIV. ARRANQUE 2Ø5/8 2Ø5/8


VALVULA TUBERIA DE

CISTERNA ESCALA: 1/25


FLOTADOR
IMPULSION
CONTROL
Ø 1 1/2" Fº GDO.
1.00

AUTOMATICO
DE NIVEL

PVC SAP Ø1/2"


VALVULA CON FILTRO

HACIA LOS SERVICIOS


VOL.= 1.00 m3 2Ø5/8 2Ø5/8
.20

2Ø5/8 2Ø5/8
A A

2.40

2.40
1.60
2Ø5/8 2Ø5/8

2Ø5/8 2Ø5/8
1.60

Especificaciones Tecnicas

.25

.30

.30
2Ø5/8 2Ø5/8
CONCRETO ARMADO:
.25

2Ø5/8 2Ø5/8
COLUMNAS TANQUE CISTERNA : 210 kg/m2 .40 2.20 .40
VIGAS, LOSAS, TANQUE ELEVADO: 210 kg/cm2
CONCRETO ARMADO:
ARMADURA DE LOZA MACIZA

2.50
ACERO SIDER - PERU : 4,200 kg/m2 2Ø5/8 2Ø5/8
ESC 1/25
TERRENO: 2Ø5/8 2Ø5/8
2.50

RESISTENCIA DEL TERRENO


CALICATA 1 : 2.35 kg/cm2

8.51
CALICATA 2 : 2.06 kg/cm2 CORTE A-A

.25
INDICACIONES
8.51

Ø 1/2" @ 0.20
UTILIZAR MORTERO: CEMENTO-ARENA, PROPORCION 1:5 , EN MUROS PORTANTES 2Ø5/8 2Ø5/8
.25

UTILIZAR LADRILLO MACIZO 2Ø5/8 2Ø5/8

DESENCOFRAR EL TECHO ALIGERADO POR LO MENOS A LOS 28 DIAS DE VACEADO Ø 1/2" @ 0.20
COMO MINIMO, Y CURAR DURANTE UNA SEMANA.

2.30
2Ø5/8 2Ø5/8

2Ø5/8 2Ø5/8
ARMADURA DE LOZA MACIZA
CUADRO DE COLUMNAS CUADRO DE VIGAS ESC 1/25
2.30

TIPO TIPO

0.25
0.30

ARMADURA ARMADURA

.25
0.25

0.40

CUADRO DE DOBLECES LONGITUDES MINIMAS DE ACERO


.25

1.16
FIERROS FIERROS 2Ø5/8 2Ø5/8

+0.00 NPT DIAMETRO D (cm.) L (cm.)


TRANSLAPE
TAPON Ø3/8",1@.05,4@.10, Ø3/8",1@.05,5@.10, 2Ø5/8
Ø ANCLAJE
2Ø5/8
1/4 " 4.00 10.00
ESTRIBOS ESTRIBOS
2@.15,RTO.@.20 C/E. 5@.15,RTO.@.25 C/E.
1/4" .30 .30
1.16

ELECTROBOMBA
3/8 " 6.00 15.00 3/8" .30 .40
0.10

2 HP

1/2 " 8.00 20.00 1/2" .40 .55


5/8 " 10.00 25.00 5/8" .55 .70
3/4" 1.00 .70
2Ø5/8 2Ø5/8
1.98

2Ø5/8 2Ø5/8

.65
PROYECTO
ADICIONAL DE OBRA "CREACION DE LA CASA DEL ADULTO
.50

VOL.= 2.00 m3 MAYOR EN EL DISTRITO DE SANTA BARBARA DE CARHUACAYA


.08

PLANO
TANQUE ELEVADO Y CISTERNA LAMINA
DEPARTAMENTO ESCALA

PROVINCIA
JUNIN

YAULI
FECHA
INDICADA
TEC
JULIO. 2019
CONSULTOR
1.65 1.20 1.65 DISTRITO
SBC
DIGITADO
PvH O1
ING. PAUL R. ACOSTA SANTIVAÑEZ CIP.167328
ARCHIVO
OF. REAL
OFICINA: CALLE ARICA 510 SAN JERONIMO DE TUNAN -HUANCAYO