Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
M
LIVE LOAD = 0.5 T/ m 2
4.90
TOTAL LOAD (Wu) 0.995 T/ m 2
d) Concrete Grade =M 25
Ly=
e) Grade of steel= Fe 500
From Table 26 of IS: 456 -2000,Moment Factors & subsequently Moments and reinf. are obtained as below:
Spacing
Moments pt required Ast Reqd. Dia of provided Spacing
Dir. Location Moment Factors Mu/bd2 provided
(T-M/M run) (%) (mm2) reinforcement reqd(mm)
(mm)
Suppt. axs = 0.043 axs.w.lx2 = 1.42 0.83 0.20 259.38 8 193.7 125.00
X-Dir
Span a =
x
m
0.032 axm.w.lx2 = 1.06 0.61 0.15 191.26 8 262.7 150.00
Suppt. ay =
s
0.037 ays.w.lx2 = 1.22 0.71 0.17 221.39 8 227 125.00
Y-Dir
Span aym = 0.028 aym.w.lx2 = 0.92 0.54 0.13 166.37 8 302 150.00
CHECK FOR SERVICABILITY
pt Provided = 0.26 %
fs = 166 N/Sqmm.
Where,
Effective Span (Lx) = centre to centre dist. of support = 4.70 M
Mod Factor= depending on pt provided = 2.00
Therefore,
dreqd. = 90.38 mm.<Provided OK
TYPICAL DESIGN OF FIRST FLOOR SLAB
Slab Panel Mkd. S1
Lx= Data
4.83 M a) Ly/Lx = 1.03
b) Edge Condition: Two adjucent edge Discontinuous.
M
LIVE LOAD = 0.5 T/ m 2
4.95
TOTAL LOAD (Wu) 0.995 T/ m 2
d) Concrete Grade =M 25
Ly=
e) Grade of steel= Fe 500
From Table 26 of IS: 456 -2000,Moment Factors & subsequently Moments and reinf. are obtained as below:
Spacing
Moments pt required Ast Reqd. Dia of provided Spacing
Dir. Location Moment Factors Mu/bd2 provided
(T-M/M run) (%) (mm2) reinforcement reqd(mm)
(mm)
Suppt. axs = 0.053 axs.w.lx2 = 1.84 1.07 0.26 340.60 8 147.51 125.00
X-Dir
Span a =
x
m
0.04 axm.w.lx2 = 1.39 0.81 0.19 254.14 8 197.7 150.00
Suppt. ay =
s
0.047 ays.w.lx2 = 1.63 0.95 0.23 299.99 8 168 125.00
Y-Dir
Span aym = 0.035 aym.w.lx2 = 1.22 0.71 0.17 221.39 8 227 150.00
CHECK FOR SERVICABILITY
pt Provided = 0.26 %
fs = 220 N/Sqmm.
Where,
Effective Span (Lx) = centre to centre dist. of support = 4.83 M
Mod Factor= depending on pt provided = 2.00
Therefore,
dreqd. = 92.79 mm.<Provided OK
TYPICAL DESIGN OF RCC WALL
The Rcc wall is to be Designed as Vertical Slab panel on which earth pressure as Super Dead load and Surcharge as Live load is acting
M
LIVE LOAD = 0.5 T/ m 2
5.57
TOTAL LOAD (Wu) 3.525 T/ m 2
d) Concrete Grade =M 25
Ly=
From Table 26 of IS: 456 -2000,Moment Factors & subsequently Moments and reinf. are obtained as below:
Spacing
Moments pt required Ast Reqd. Dia of provided Spacing
Dir. Location Moment Factors Mu/bd2 provided
(T-M/M run) (%) (mm2) reinforcement reqd(mm)
(mm)
Suppt. axs = 0.063 axs.w.lx2 = 4.81 0.96 0.23 517.44 12 218.47 150.00
X-Dir
Span a =
x
m
0.047 axm.w.lx2 = 3.59 0.72 0.17 380.80 12 296.9 150.00
Suppt. ays = 0.037 ays.w.lx2 = 2.83 0.56 0.13 297.92 10 264 150.00
Y-Dir
Span a =
y
m
0.028 ay .w.lx =
m 2
2.14 0.43 0.10 224.00 10 351 150.00
CHECK FOR SERVICABILITY
pt Provided = 0.34 %
fs = 147 N/Sqmm.
Where,
Effective Span (Lx) = centre to centre dist. of support = 3.80 M
Mod Factor= depending on pt provided = 1.00
Therefore,
dreqd. = 146.15 mm.<Provided OK
EARTH PRESSURE
HEIGHT OF RETAINING WALL 4 M
ANGLE OF INTERNAL FRICTION(ǿ) 30 DEGREE
ACTIVE EARTH PRESSURE COEFFICIENT((1-SIN(ǿ))/(1+SIN(ǿ)))
0.333538
EARTH PRESSURE AT BASE DUE TO BACKFILL 2.401472 T/M2 UNIT WEIGHT OF SO 1.8
T/M3
TYPICAL DESIGN OF ROOF FLOOR SLAB (S1)
Slab Panel Mkd. S1
Lx= OUTER PANEL IN BETWEEN GRID A-B&3-4
3.96 M a) Ly/Lx = 1.41
b) Edge Condition: Two adjacent edges discontinuous
M
LIVE LOAD = 0.15 T/ m 2
5.57
TOTAL LOAD (Wu) 0.708 T/ m 2
d) Concrete Grade =M 25
Ly=
e) Grade of steel= Fe 500
From Table 26 of IS: 456 -2000,Moment Factors & subsequently Moments and reinf. are obtained as below:
Spacing
Moments pt required Ast Reqd. Dia of provided Spacing
Dir. Location Moment Factors Mu/bd2 provided
(T-M/M run) (%) (mm2) reinforcement reqd(mm)
(mm)
Suppt. axs = 0.075 axs.w.lx2 = 1.25 0.85 0.21 248.05 8 202.54 200.00
X-Dir
Span a =
x
m
0.056 ax .w.lx =
m 2
0.93 0.64 0.15 182.71 8 275 200.00
Suppt. ay =
s
0.047 ays.w.lx2 = 0.78 0.53 0.13 152.46 8 330 200.00
Y-Dir
Span aym = 0.035 aym.w.lx2 = 0.58 0.40 0.09 112.53 8 447 200.00
TYPICAL DESIGN OF ROOF FLOOR SLAB (S1)
CHECK FOR SERVICABILITY
pt Provided = 0.21 %
fs = 211 N/Sqmm.
Where,
Effective Span (Lx) = centre to centre dist. of support = 3.96 M
Mod Factor= depending on pt provided = 1.30
Therefore,
dreqd. = 117.16 mm.<Provided OK