Building Standards
and Guidelines By Gary Madaras
2. Limit occupant noise The use of STC indicates that demising 3. Limit exterior environmental
transmission between walls extend vertically from slab to slab and noise transmission
interior rooms. all penetrations are sealed airtight. Relying on into the building.
Construct rooms, including slabs, walls, a modular acoustic ceiling alone – for exam- Construct the building’s envelope, includ-
windows, doors and penetrations so that ple, when the wall stops at the ceiling and ing the roof, façade, windows and doors,
they limit the amount of occupant noise that does not completely block off the plenum – so that they limit the amount of exterior
transmits between rooms. cannot provide the levels of isolation required environmental noise that transmits into
Key interior sound blocking metrics in the by the standards and guidelines. A modular, occupied rooms.
standards and guidelines: acoustic ceiling does not have enough mass Key exterior sound blocking metrics in the
• STC (Sound Transmission Class) – The to block sound. The lights, air devices and standards and guidelines:
sound blocking capacity of a wall or other other elements also result in noise leaks, OITC (Outdoor Indoor Transmission
assembly. worsening performance. For these reasons, Class) – The sound blocking capacity of
• NIC (Noise Isolation Class) – The total CAC (Ceiling Attenuation Class) is not a part a roof, window, building façade or façade
sound blocking capacity between two of most standards and guidelines. component.
rooms as measured in the field after con- Glass wall systems and windows should OITC values required for the building shell
struction is complete. be limited in size and insulated and/or vary greatly based on the use of the building
Most standards and guidelines require laminated to increase their sound blocking and the noise levels on and around the site.
sound isolation levels of STC/NIC 40, 45 capacity. Doors should swing, not slide, and OITC values range from 35-40 for a relatively
or 50+. have full perimeter seals. quiet site up to 60 for a very noisy site.
1. Having an STC rating for wall construction typically indicates that the wall is full height from slab to
slab. Note that CAC (Ceiling Attenuation Class), a measure of a ceiling panel’s blocking capacity is not
typically in acoustic standards and guidelines. Using a suspended, modular, acoustic ceiling alone to
block sound does not meet the expected level of sound privacy performance between rooms.
2. Values are for ceilings and are minimums. Additional absorption on walls also may be required.
3. Guidelines for Design and Construction of Hospitals and Outpatient Facilities, 2014 edition.
4. NRCs of all surfaces are used to calculate a minimum room average absorption coefficient.
5. Core CHPS metrics. Regional versions of the CHPS criteria, e.g. NE-CHPS v3, may be more stringent.
6. Assumes a relatively quiet project site.
Higher OITC values can result from more offices, corridors, waiting rooms and lob-
massive exterior wall and roof construction bies may have higher values (NC-40).
and selecting acoustically rated window or Complying with the background noise
curtainwall systems. levels in the standards and guidelines
relates mostly to the design of the building
4. Limit noise levels generated system themselves. However, having sound
by building mechanical, absorption inside occupied rooms can help
electrical and plumbing to decrease perceived background noise.
systems inside occupied rooms. The summary table on the opposite page
Design the building systems appropriately, should assist with understanding these
select quiet equipment and include noise and four categories for acoustics criteria in
vibration control measures to limit the back- building standards and guidelines.
ground noise levels.
Key system noise control metrics in the stan- Gary Madaras, PhD, Assoc. AIA, leads
dards and guidelines: Optimized Acoustics™ at ROCKFON and rep-
• NC (Noise Criterion) – Building system back- resents the company as a CISCA member.
ground noise level classification. He also is a full member of the Acoustical
• dBA or dBC (weighted decibels) – broad- Society of America and chairs the society’s
band sound level that is either A-weighted or Healthcare Acoustics Subcommittee; a
C-weighted to better represent how people member of the Institute of Noise Control
hear sound. Engineering and a member of the Canadian
NC values for most rooms vary between Acoustics Association. Learn more at
NC-25 (quiet) to NC-35 (normal). Some open www.OptimizedAcoustics.com.