Sei sulla pagina 1di 6

ISOLATED FOOTING OF SQUARE TYPE FOOTING NO:

DATE
GIVEN DATA:-
VERTICAL LOAD - 238
SIDE (a) OF COLUMN- (LONGER SIDE) 0.38
SIDE (b) OF COLUMN (SHORTER SIDE) 0.23
SAFE BEARING CAPACITY OF SOIL 250
CALCULATION OF AREA OF FOOTING& CHECK FOR ITS SAFTY:-
LOAD ON COLUMN 261.8
AREA REQUIRED FOR FOOTING 1.0472
SIDE OF FOOTING 1.0233279044
REQUIRED SIDE OF FOOTING 1.03
NET FACTORED UPWARD PRESSURE 370.1574135168
SAFETY CHECK FOR UPWARD PRESSURE ITS SAFE

CALCULATION OF BENDING MOMENT:-


AREA SUFFERED BY BENDING PER M 0.4
C.G OF FORCE 0.2
BENDING MOMENT 29.6125930813
ASSUMED DEPTH,D 340
DIA OF STEEL WHICH IS BEING USED 10
COVER FOOTING 50
EFFECTIVE DEPTH OF FOOTING,Def 275
COMPRESSIVE STRENGTH OF CONCRETE,Fck 20
TENSILE STRENGHTH OF STEEL,Fy 500
AREA OF STEEL REQUIRED FOR FOOTING,ASTreq 203.2701362566
SPACING REQUIRED FOR STEEL 386.1856023007
SPACING PROVIDED FOR STEEL 200
NO. OF BARS PROVIDED FOR FOOTING 7
AREA OF STEEL PROVIDED ,AST prov 549.5

CHECK FOR ONE WAY SHEAR

PERCENTAGE OF STTEL,Pt 0.16


SHEAR STRESS,Ԏc 0.28
VALUE OF K 1
THE PERMISSIBLE SHEAR STRESS-Ԏc*k 0.28
SHEAR FORCE OF CONCRETE,Vconc 79.31
EXTERNAL SHEAR FORCE, V u 47.6577669903
SAFTY CHECK FOR ONE WAY SHEAR FORCE ITS SAFE
NOMINAL SHEAR STRESS,Ԏv 0.1682533698
SAFTY CHECK FOR ONE WAY SHEAR STRESS ITS SAFE

CHECK FOR TWO WAY SHEAR/ PUNCHING SHEAR

PUNCHING SHEAR AREA 0.730125


PUNCHING SHEAR FORCE 270.261181544
PERIMETER OF TWO WAY SHEAR 2.32
NOMINAL SHEAR STRESS ,Ԏv 0.4236068676
SHEAR STRESS,Ԏc 1.1180339887
VALUE OF Ks 1
THE PERMISSIBLE SHEAR STRESS-Ԏc*Ks 1.1180339887
SAFTY CHECK FOR TWO WAY SHEAR STRESS ITS SAFE
RESULT:-
HENCE PROVIDE SPACING OF 200 mm
DIAMETER OF STEEL AS 10 mm
25.10.2016

KN 325 238.333333333
m
m
Kn/m^2

KN
m^2
m f in
m 3.3792650919 3 4.5511811024
kn/m^2

m^2/M
KN/M
kNm/M
mm 13.3858267717
mm
mm
mm
N/mm^2
N/mm^2 DESIGN SHEAR STRENGTH OF CONCRETE Ԏc, N/mm^2
mm^2/M 100Ast/bd CONCRETE GRADE
mm M15 M20 M25 M30
mm 1 2 3 4 5
<=.15 0.28 0.28 0.29 0.29
mm2 0.25 0.35 0.36 0.36 0.36
0.5 0.46 0.48 0.49 0.49
0.75 0.54 0.56 0.57 0.57
1 0.6 0.62 0.64 0.64
% 1.25 0.64 0.67 0.7 0.7
N/mm^2 1.5 0.68 0.72 0.74 0.74
1.75 0.71 0.75 0.78 0.78
N/mm^2 2 0.71 0.79 0.82 0.82
KN 2.25 0.71 0.81 0.85 0.85
KN 2.5 0.71 0.82 0.88 0.88
2.75 0.71 0.82 0.9 0.9
N/mm^2 3=< 0.71 0.82 0.92 0.92

m^2
KN
m
N/mm^2
N/mm^2

N/mm^2

BOTHWAYS 7.874015748
Ԏc, N/mm^2

M35 M40& above


6 7
0.29 0.3
0.37 0.38
0.5 0.51
0.59 0.6
0.67 0.68
0.73 0.74
0.78 0.79
0.82 0.84
0.86 0.88
0.9 0.92
0.93 0.95
0.96 0.98
0.99 1.01
DESIGN SHEAR STRENGTH OF CONCRETE Ԏc, N/mm^2
100Ast/bd CONCRETE GRADE
M15 M20 M25 M30 M35 M40& above
1 2 3 4 5 6 7
<=.15 0.28 0.28 0.29 0.29 0.29 0.3
0.25 0.35 0.36 0.36 0.36 0.37 0.38
0.5 0.46 0.48 0.49 0.49 0.5 0.51
0.75 0.54 0.56 0.57 0.57 0.59 0.6
1 0.6 0.62 0.64 0.64 0.67 0.68
1.25 0.64 0.67 0.7 0.7 0.73 0.74
1.5 0.68 0.72 0.74 0.74 0.78 0.79
1.75 0.71 0.75 0.78 0.78 0.82 0.84
2 0.71 0.79 0.82 0.82 0.86 0.88
2.25 0.71 0.81 0.85 0.85 0.9 0.92
2.5 0.71 0.82 0.88 0.88 0.93 0.95
2.75 0.71 0.82 0.9 0.9 0.96 0.98
3=< 0.71 0.82 0.92 0.92 0.99 1.01