© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 1
SmartForce Features
Introduction
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 2
SmartForce Features and Attachments
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 3
SmartForce Features and Attachments
Threshold
Maximum
Visual Feature Available on Movement for Velocity
placement
Multi-tooth
All four upper 0.5mm of
Extrusion Incisor extrusion 0.25 mm / stage
incisors extrusion
Attachment
Absolute extrusion
Extrusion ±
0.1 mm + crown
crown tipping ±
tipping + > 5 deg
rotation
rotation
Optimized
Upper lateral 0.25 mm / stage or
Multi-Plane OR 2 degrees / stage
incisors Rotation > 5 deg
Attachment
+ intrusion
Rotation with
intrusion or
Rotation > 5 deg +
extrusion
extrusion
Movement
Threshold
Maximum
Visual Feature Available on Movement for Velocity
placement
Precision Bite
Ramps*
(* are not SmartForce
features per se, but Disocclude the
Upper incisors NA NA
can be prescribed by the
Provider, and
posterior teeth
are placed depending on
compatibility
with other features)
Threshold
Maximum
Visual Feature Available on Movement for Velocity
placement
Rotation 5 degrees
Optimized Rotation +/-
Upper and lower in either direction 0.25 mm / stage or
Multi-plane intrusion or 2 degrees / stage
molars with or without
Attachment extrusion
extrusion/intrusion
Conventional attachments can be prescribed in addition or in lieu to any other attachment or SmartForce
feature placed by default (depending on compatibility).
2 mm 1 mm 2 mm 1 mm 1.25 mm
Attachments interface
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 15
SmartForce Protocols
Invisalign SmartForce Features per Tooth & Movement Programmed default placement rules
Lingual Root
Rotation Extrusion Intrusion M/D Root Tip Retention
Torque
Single Buccal Power
Upper Optimized Ridge feature or
Lingual Pressure Optimized Root
Central n/a Extrusion (single
Area Control
n/a Dual Buccal + Lingual
Incisors and multi-tooth) Power Ridge feature for
LRT + Retraction
Single Buccal Power
Upper Optimized Optimized Support Ridge feature or
Optimized Lingual Pressure Optimized Root
Lateral Multiplane
Extrusion (single
Area Control
(Individual Central or Canine Dual Buccal + Lingual
and multi-tooth) Intrusion) Power Ridge feature for
Incisors
LRT + Retraction
Optimized Optimized
U/L Molars Multiplane Extrusion
n/a n/a n/a n/a
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 16
SmartForce Protocols
Pressure areas are placed lingually and are compatible with buccal attachments and buccal Power Ridge features.
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 17
SmartForce Placement Protocols – Placement Hierarchy per Tooth
• P1: Multi-tooth Optimized Extrusion – when all four • P1: Multi-tooth Optimized Extrusion – when all four
incisors are extruding incisors are extruding
• P3: Optimized Extrusion (individual) • P3: Optimized Multiplane (rotation & rotation with
intrusion or extrusion)
• P4: Power Ridge feature for Lingual Root Torque
• P3: Optimized Extrusion (individual)
Note: Pressure areas are placed lingually and are compatible with buccal attachments and buccal Power Ridge features.
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 18
SmartForce Placement Protocols – Placement Hierarchy per Tooth
• P1: Optimized Extrusion (individual) • P1: Optimized Retraction (for bicuspid space closure)
• P2: Power Ridge feature for Lingual Root Torque • P2: Optimized Root Control
Note: Pressure areas are placed lingually and are compatible with buccal attachments and buccal Power Ridge features.
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 19
SmartForce Placement Protocols – Placement Hierarchy per Tooth
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 20
Placement per Clinical Solution
First Bicuspid Extractions –
Maximum or Moderate
Anchorage
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 23
Placement per Clinical Solution Open Bite Correction
Lower Incisors:
• Optimized Extrusion
(individual)
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 24
Default Protocols
• For certain Invisalign treatments, conventional attachments will be placed by default1 (unless otherwise specified in
Clinical Preferences or in the Prescription Form), sometimes in combination with Optimized Attachments in
another teeth.
• Providers may request attachments when aligner retentiveness is a concern. Attachments for aligner retention are
NOT offered by default.
1The Invisalign default protocols are used to create the initial ClinCheck Treatment Plan, based on the Invisalign Provider’s prescription.
However, the final treatment plan remains the responsibility of the Invisalign Provider and should be reviewed carefully and modified as
necessary before the ClinCheck Treatment Plan is approved.
Molars:
• Conventional Vertical
Rectangular attachment
Bicuspid:
• Optimized Root Control
Attachment
Canines:
• Optimized Root Control
Attachment
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 26
Placement per Clinical Solution Lower Incisor Extraction
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 27
SmartForce Placement Protocols
Common reasons why attachments may not be placed
• There isn’t a default attachment defined for a given tooth movement programmed.
• A preference has not been set to place an attachment on a given tooth movement.
• Movement threshold triggers attachment placement, but another attachment has a higher priority.
• Due to feature conflict (i.e. Precision Cut and attachment don’t fit together).
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 28
SmartForce Placement Protocols
Common reasons why attachments may not be placed
• Movement threshold triggers attachment placement, but there is another feature that isn't compatible.
• Movement threshold triggers attachment placement, but there isn't enough space/clinical
crown/collision/pinching/gingiva.
• Backup attachments alternatives can be used, based on internal protocol or Doctor preferences
© 2017 Align Technology, Inc. All rights reserved. Confidential – For Internal Use Only 29