Electric Power / Controls VARIABLE SPEED DRIVES
MODELS 3250, 3260

GENERAL DESCRIPTION
The Lab-Volt Variable Speed Drives enable students to Speed, Maximum Speed, Acceleration, IR Compensation
develop competence in operating and troubleshooting a (Regulation), and Current Limit by means of five po-
control system that includes industrial type drives. The tentiometers located on the main circuit board. The
trainers are designed to work with the Lab-Volt 3100 speed of the motor is adjusted by the means of a potenti-
and 8000 series controls and motors, as well as most ometer located on the faceplate of the drive or an insu-
commercial motors. Courseware includes Operation lated voltage source of 0 to 12 V dc.
Manual and Project Job Sheets addressing set up and
operation of the drive and its controls. Model 3260 AC Variable Speed Drive
The Model 3260 AC Variable Speed Drive uses the latest
Model 3250 DC Variable Speed Drive solid state PWM technology to control a 3-phase squirrel
This is an industrial type drive whose power circuitry is cage induction motor. A keypad and an LCD screen allow
composed of a half bridge with two thyristors and modification and visualization of many different parame-
two diodes. A full wave field voltage is provided for shunt ters, such as min/max speed, acceleration/deceleration
wound motors. The drive includes controls for Minimum time, torque, etc.

(732) 938-2000 / 800-LAB-VOLT, FAX: (732) 774-8573, E-MAIL: us@labvolt.com


(418) 849-1000 / 800-LAB-VOLT, FAX: (418) 849-1666, E-MAIL: ca@labvolt.com
INTERNET: http: //www.labvolt.com
is under
data sheetSPEED
ThisVARIABLE revision. Please,
DRIVES
contact
MODELS 3250,(services@labvolt.ca
Services 3260 )
ordering
before The this
V/Hz output equipment.
characteristic is user-selectable for The AC Variable Speed Drive is available in two
constant torque, pump, or fan applications. Up to eight versions: Models 3260-1 and 3260-2. Model 3260-1
preset speeds may be programmed. requires 120-V, 60 Hz power available from any standard
Speed can be controlled using either the digital key- wall outlet. This single-phase option is not available for
pad or the analog input on the front panel of the module. 220 V and 240 V, 50 Hz, line supplies. Model 3260-2
requires three-phase supply. The three-phase supply is
applied at the 4-mm banana jacks on the front panel of
the module.

ADDITIONAL EQUIPMENT REQUIRED TO PERFORM THE EXERCISES IN MANUAL 76097


QTY DESCRIPTION MODEL NUMBER
1 Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8134
1 DC Motor/Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8211
1 Three-Phase Synchronous Motor/Generator1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8241
2 Resistive Load1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8311
1 DC Voltmeter/Ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8412
1 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8821
1 Prony Brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8913
1 Inertia Wheel2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8915
1 Speed Sensor / Tachometer or Digital Tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8931/8920
1 Timing Belt1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8942
1 Connection Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8951
1 Insulated, variable-voltage (0-5 V) DC Power Supply3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –

ADDITIONAL EQUIPMENT REQUIRED TO PERFORM THE EXERCISES IN MANUAL 76098


QTY DESCRIPTION MODEL NUMBER
1 Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8134
1 Four-Pole Squirrel-Cage Induction Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8221
1 AC Voltmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8426
1 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8821
1 Speed Sensor / Tachometer or Digital Tachometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8931/8920
1 Connection Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8951

NOTE: Projects may also be performed using the Lab-Volt 3100 series Industrial Controls and/or equipment from other manufacturers with equivalent equipment
specifications and characteristics. The trainer will drive any motor of proper type and rating.

SPECIFICATIONS
Model 3250 – DC Variable Speed Drive 120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
Ratings Input Power Requirement 120 V – 13 A – AC 220 V – 13 A – AC 240 V – 13 A – AC
Output Voltage 0-90 V – DC 0-165 V – DC 0-180 V – DC
Field Voltage 100 V – DC 180 V – DC 200 V – DC
Maximum Field Current 1 A – DC
Rated Output Current 10.8 A
Control Method Phase Control
Physical Characteristics Dimensions (H x W x D) 30 x 28 x 34 cm (11.7 x 10.9 x 13.3 in)
Net Weight 5.5 kg (12 lb)
1
Can be used to replace the Prony brake, Model 8913, in Exercise 4.
2
Used in Exercise 6 only.
3
Used in Exercise 7 only.
This data sheet is under revision. Please,
contact Services (services@labvolt.ca )
before ordering this equipment.
SPECIFICATIONS (cont'd)
Model 3260 – AC Variable Speed Drive 120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
Ratings Input Power Requirement (3260-2) 120/208 V – 3.8 A 220/380 V – 2.3 A TBE4
Input Power Requirement (3260-1) 120 V, 9 A – 60 Hz N/A N/A
Maximum Output Voltage 120/208 V – 3 ~ 220/380 V – 3 ~ TBE
Rated Output Current 4A 2.2 A TBE
Output Frequency 0.1 to 400 Hz TBE
Carrier Frequency 9.2 kHz TBE
Control Method Sine wave PWM TBE
Analog Inputs Type Speed
Level 0-5 V – DC
Physical Characteristics Dimensions (H x W x D) 365 x 260 x 330 (14.4 x 10.2 x 13.0)
3260-10 3260-20
Net Weight 7.3 kg (16 lb) 6.4 kg (14 lbs)

COURSEWARE
ORDERING NUMBER5
Manual Skills - Student
DC Variable Speed Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76097-20
AC Variable Frequency Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76098-20

Manual Skills - Teacher


DC Variable Speed Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76097-30
AC Variable Frequency Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76098-30

TOPIC COVERAGE
DC Variable Speed Drive (76097-20) AC Variable Frequency Drive (76098-20)
– Trainer Familiarization – Trainer Familiarization
– Maximum Speed Trimpot Adjustment – Maximum Speed Control Characteristics
Characteristics – Minimum Speed Control Characteristics
– Minimum Speed Trimpot Adjustment Characteristics – Acceleration Control Characteristics
– Speed Regulation Trimpot Adjustment – Deceleration Control Characteristics
Characteristics – Boost Control Characteristics
– Current Limit Trimpot Adjustment Characteristics – System Configuration
– Acceleration Trimpot Adjustment Characteristics
– Remote Control Characteristics
– System Configuration

4
TBE = To be established
5
Various versions are available. Refer to Ordering Numbers section.
is under
data sheetSPEED
ThisVARIABLE revision. Please,
DRIVES
contact
MODELS 3250,(services@labvolt.ca
Services 3260 )
before
ORDERING this equipment.
orderingNUMBERS
MODEL 120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
NUMBER ENGLISH FRENCH SPANISH ENGLISH FRENCH SPANISH ENGLISH
3250 3250-10 3250-11 3250-12 3250-15 3250-16 3250-17 3250-1A
3260-1 3260-10 3260-11 3260-12 N/A N/A N/A N/A
3260-2 3260-20 3260-21 3260-22 3260-25 3260-25 3260-26 TBE
8134 8134-20 8134-20 8134-20 8134-20 8134-20 8134-20 8134-20
8211 8211-00 8211-01 8211-02 8211-05 8211-06 8211-07 8211-0A
8221 8221-00 8221-01 8221-02 8221-05 8221-06 8221-07 8221-0A
8241 8241-00 8241-01 8241-02 8241-05 8241-06 8241-07 8241-0A
8311 8311-00 8311-01 8311-02 8311-05 8311-06 8311-07 8311-0A
8412 8412-00 8412-01 8412-02 8412-05 8412-06 8412-07 8412-05
8426 8426-00 8426-01 8426-02 8426-05 8426-06 8426-07 8426-05
8821 8412-20 8821-21 8821-22 8412-25 8821-26 8821-27 8821-2A
8913 8913-00 8913-01 8913-02 8913-10 8913-11 8913-12 8913-10
8915 8915-00 8915-01 8915-02 8915-00 8915-01 8915-02 8915-00
8920 8920-40 8920-40 8920-40 8920-40 8920-40 8920-40 8920-40
8931 8931-00 8931-01 8931-02 8931-00 8931-01 8931-02 8931-00
8942 8942-00 8942-00 8942-00 8942-00 8942-00 8942-00 8942-00
8951 8951-00 8951-00 8951-00 8951-00 8951-00 8951-00 8951-00
Table 1. Equipment Ordering Numbers

120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz


ENGLISH FRENCH SPANISH ENGLISH FRENCH SPANISH ENGLISH
76097-20 TBE6 TBE TBE TBE TBE TBE
76097-30 TBE TBE TBE TBE TBE TBE
76098-20 TBE TBE TBE TBE TBE TBE
76098-30 TBE TBE TBE TBE TBE TBE
Table 2. Courseware Ordering Numbers

6
TBE= To be established

Reflecting Lab-Volt's commitment to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility
has received the ISO 9001 certification.

Lab-Volt reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Lab-Volt recognizes all product
names used herein as trademarks or registered trademarks of their respective holders. © Lab-Volt 2004. All rights reserved.