Sei sulla pagina 1di 14

GGS-000406-01E

November 2015

iPASOLINK VR 2
SPECIFICATION

NEC Corporation
7-1, Shiba 5-Chome, Minato-Ku, Tokyo 108-8001, Japan

2016-04-20 Avea
GGS-000406-01E

© 2015 by NEC Corporation

GGS-000406-01E
Printed in Japan

2016-04-20 Avea
CONTENTS –i–

iPASOLINK VR2
SPECIFICATION

CONTENTS

1. INTERFACES 1-1

1.1 iPASOLINK VR2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1


1.1.1 Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1.2 Main Card (MC-SV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 Location of Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

2. SPECIFICATION 2-1

2.1 Interface Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


2.1.1 Ethernet Traffic Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.2 E1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.3 Radio Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.4 DCN Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.5 Other Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Supported Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1 Radio Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.2 TDM Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.3 ETH Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.2.4 Management Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.5 Synchronization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.6 Performance Monitor and Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.3 Traffic Interface Specifications and Standards . . . . . . . . . . . . . . . . . . 2-6
2.3.1 1000BASE-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

3. SYSTEM PERFORMANCES 3-1

3.1 Power Consumption and Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

IPASOLINK VR2: SPECIFICATION GGS-000406-01E


September 2015

2016-04-20 Avea
– ii/END – CONTENTS

3.2 Power Line Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1


3.3 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.3.1 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.3.2 Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.4 Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

GGS-000406-01E IPASOLINK VR2: SPECIFICATION

2016-04-20 Avea
INTERFACES 1-1

1. INTERFACES

1.1 iPASOLINK VR2 Overview

1.1.1 Front View

1.1.2 Main Card (MC-SV)

PWR1 PWR2

IPASOLINK VR2: SPECIFICATION GGS-000406-01E

2016-04-20 Avea
1-2/END INTERFACES

1.2 Location of Terminals

➀➁
➂ ➄ ➆ ➇ 11 12 13 14 15 16

➃ ➅ ➈ ➉

Ref. # Indication Element Description

➀ Grounding Screw Grounding terminal.

➁ IF1 TNC Connector IF Terminal connecting to the Outdoor Unit (ODU); SYS1

IF2 TNC Connector IF Terminal connecting to the Outdoor Unit (ODU); SYS2

➂ EOW Pin Jack Orderwire Terminal

➃ MEM USB Type-A Connecting terminal for USB memory device. (Supporting
a memory device only.)

➄ CLK D-Sub Connector (Optional) Terminal for Clock Signal input/output. (15 pins)

➅ 2M IN/OUT MDR Connector E1 Traffic Signal Input/Output

➆ LCT RJ-45 Connector Ethernet port for connecting WebLCT. (Supporting 10/
100BASE-TX; Auto-Negotiation, Auto-MDI/MDIX.)

➇ NMS RJ-45 Connector Terminal for connecting to DCN Network upstream.


(Supporting 10/100BASE-TX; Auto-Negotiation,
Auto-MDI/MDIX)

➈ NE/1 RJ-45 Connector Two-Way Use: Terminal for connecting DCN Network
downstream., or traffic Ethernet signal input/output Port 1.
(Supporting 10/100/1000BASE-TX; Auto-Negotiation,
Auto-MDI/MDIX)

➉ 2 RJ-45 Connectors Traffic Ethernet signal input/output Port 2 to Port 4.


(Supporting 10/100/1000BASE-TX; Auto-Negotiation,
11 3 Auto-MDI/MDIX)
12 4
13 5 SFP Module Ports Traffic Ethernet Signal 1000BASE-SX/LX
14 6
15 PWR1 DK3100 Power Input Terminal for IDU. SELV, –48 V DC. PWR 2 is
an optional.
16 PWR2 (SELV PWR)

GGS-000406-01E IPASOLINK VR2: SPECIFICATION

2016-04-20 Avea
SPECIFICATION 2-1

2. SPECIFICATION

2.1 Interface Capacity

iPASOLINK VR2 supports various interfaces conforming to the ITU-T Standards


and IEEE Standards:

2.1.1 Ethernet Traffic Interfaces


INTERFACE SPEC CONNECTOR SUPPORTING CARD

1000BASE-SX/LX/CWDM 1.25 Gbps LC (SFP Module) 2 ports per IDU


[802.3]

10/100/1000BASE-T/TX (TX) 123 Mbps RJ-45 3 ports per IDU


(T) 10 Mbps

2.1.2 E1 Interface
INTERFACE SPEC CONNECTOR SUPPORTING CARD

HDB-3 [G.703] 16 × E1 (2.048 Mbps) MDR68 1 port per IDU


75 ohms, 120 ohms (selectable)

2.1.3 Radio Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

IF (IDU-ODU Interface) –48 V DC, TX IF, RX IF, TNC 2 ports per IDU
ODU SV

2.1.4 DCN Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

10/100BAE-T/TX (TX) 125 Mbps RJ-45 1 (LCT) port per IDU


(T) 10 Mbps
1 (NMS) port per IDU

1 (NE/1) port per IDU. This port can be used


as the traffic Ethernet by choice

IPASOLINK VR2: SPECIFICATION GGS-000406-01E

2016-04-20 Avea
2-2 SPECIFICATION

2.1.5 Other Interfaces


INTERFACE SPEC CONNECTOR DESCRIPTION

Oderwire Headset 4-Wire Voice Channel Pin Jack 1 (EOW) port per IDU

External Storage USB Type-A Female 1 (MEM) port per IDU.

GGS-000406-01E IPASOLINK VR2: SPECIFICATION

2016-04-20 Avea
SPECIFICATION 2-3

2.2 Supported Functions

iPASOLINK VR2 supports the following functions:

2.2.1 Radio Functions

Functions Supported Items

Channel Separation 7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz

Modulation 9 Modulation Schemes are changeable: QPSK, 16-QAM, 32-QAM,


64-QAM, 128-QAM, 256-QAM, 512-QAM, 1024-QAM, 2048-QAM

Configuration 1+0 Up to 2 systems per IDU

1+1 SWG Up to 1 Switch Groups per IDU

2 × RTA Group Up to 1 configurations per IDU

1+0 XPIC Group Up to 1 configurations per IDU

2.2.2 TDM Functions

Functions Supported Items

Crossconnect Terminal Point On-Board E1 Up to 16 per IDU


(E1 Channel)
On-Board MODEM Up to 152 per IDU

Crossconnect Capacity E1 Channel 2-Way Up to 160 per IDU (2 × MODEM-152CH


+ 1 × E1-16CH  2)

IPASOLINK VR2: SPECIFICATION GGS-000406-01E

2016-04-20 Avea
2-4 SPECIFICATION

2.2.3 ETH Functions

Functions Supported Items

VLAN VLAN ID Up to 4094 per IDU

C-Bridge Instance Up to 16 per IDU

Customer Bridge (in C-


Up to 15 per C-Bridge Instance
Bridge Instance)

VLAN Swap Up to 256 per IDU

FDB All Entries


Up to 32K per IDU
(Dynamic + Static)

Static Entries Up to 256 per IDU

Filter Ingress Filter Up to 16 per IDU

Egress Filter Up to 16 per IDU

Filter Rules (L2/L3) Up to 512 per IDU

QoS (VLAN Based) VLAN Group Up to 8 per IDU

Up to 4095 VLANs per VLAN Group

Priority Shaper Up to 8 per IDU

Mapping Table Up to 16 per IDU

QoS (Port Based) Classification Profile Up to 16 per IDU

Policer Policer Instance Up to 256 per IDU

Policer Rate Profiler Up to 64 per IDU

ETH OAM MEG Instances Up to 128 per IDU

MEP Instances Up to 128 per IDU

Peer MEP Up to 32 per IDU

Ethernet Ring Ring Index Up to 16 per IDU

RSTP/MSTP MSTI Up to 4 per Instances

Link Aggregation LAG Member Up to 8 per LAG

LAG Instance Up to 8 per IDU

GGS-000406-01E IPASOLINK VR2: SPECIFICATION

2016-04-20 Avea
SPECIFICATION 2-5

2.2.4 Management Plane


Functions Supported Items

Inband Management VLAN Inband Interface Up to 4 per IDU

NMS Management VLAN NMS Port Up to 4 per IDU

Software Bridge Software Bridge ID Up to 8 per IDU

User Account User Account Up to 100 per IDU

ARP ARP Cache Up to 1024 per IDU

Static ARP Up to 256 per IDU

Routing Static Route Up to 128 per IDU

NTP NTP Server Up to 4 per IDU

DHCP DHCP Server Up to 3 per IDU

DHCP Relay Up to 4 per IDU

SNMP SNMP Community Up to 10 IDU

SNMP Trap Up to 3 per IDU

RADIUS RADIUS Server Up to 3 per IDU

2.2.5 Synchronization
Functions Supported Items

Timing Source Up to 3 per IDU

PTP Port Entry Up to 8 Physical Ports per IDU

Master Entry Up to 5 Physical Ports per IDU

2.2.6 Performance Monitor and Logs


Functions Supported Items

Log History Log Command, Event, Alarm


Up to 8,000 items per system

PM 15-Min History (Instance)

1-Day History (Instance)

VLAN Counter Up to 256 per IDU

IPASOLINK VR2: SPECIFICATION GGS-000406-01E

2016-04-20 Avea
2-6/END SPECIFICATION

2.3 Traffic Interface Specifications and Standards

2.3.1 1000BASE-X
ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

1000BASE-SX 1000BASE-LX

Nominal Bit Rate 1250 Mbit/s

Coding Method 8B/10B

Transmitter at Reference Point S

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm

SMSR 0.85 dB (RMS) 4 dB (RMS)

Maximum Mean Launched Power 0 dBm –3 dBm

Minimum Mean Launched Power –9.5 dBm –11 dBm

Minimum Extinction Ratio (dB) 9 dB or more 9 dB or more

Receiver at Reference Point R

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm

Maximum Mean Launched Power –17 dBm –19 dBm

Minimum Mean Launched Power –0 dBm –3 dBm

Others

Target Distance 550 m 5 km

Type of Fiber Cable MMF: GI Cable SMF: SI Cable


(Core/Clad dia.: 50/125 µm) (Core/Clad dia.: 9/125 µm)

Connector LC Connector using SFP

GGS-000406-01E IPASOLINK VR2: SPECIFICATION

2016-04-20 Avea
SYSTEM PERFORMANCES 3-1

3. SYSTEM PERFORMANCES

3.1 Power Consumption and Size

Ref. POWER DIMENSIONS


OBJECT WEIGHT DESCRIPTION
# CONSUMPTION [W × H × D] mm

1 IDU 56 W 483 × 44 × 230 3 kg (approx.)

MC-SV 51 W★ 384 × 30 × 215 0.8 kg Main Card; Class 1 Product

2 CLK-CV 001 3W 70 × 30 × 85 0.1 kg Used on MC-SV Card

CLK-CV 002 1W 70 × 30 × 85 0.1 kg

3 SFP 1W 14 × 10 × 57 0.015 kg GbE

★: The value does not include that of SFP/SFP+ modules.

3.2 Power Line Requirements


Condition Requirements

Input Voltage Range –48 V DC (–40.5 to –57 V DC)


ETSI EN 300 132-2

Connector 4-Pin, 3.81 mm Pitch [1-178288-4]

IPASOLINK VR2: SPECIFICATION GGS-000406-01E

2016-04-20 Avea
3-2/END SYSTEM PERFORMANCES

3.3 Environmental Conditions

3.3.1 Temperature

Condition Requirements

Operating –5 to +50°C
Reference: –5 to+45°C by ETSI EN 300 019-1-3
Class 3.1E in the EU market

Transportation –40 to +70°C (ETSI EN 300 019-1-2 Class 2.3)

Storage –25 to +55°C (ETSI EN 300 019-1-1 Class 1.2)

3.3.2 Humidity

Condition Requirements

Operating Up to 95% (at +50°C, no condensing)


Reference: ETSI EN 300 019-1-3 Class 3.1E in the
EU market

Transportation ETSI 300 019-1-2 Class 2.3

Storage ETSI 300 019-1-1 Class 1.2

3.4 Others
Cateogry Standards

EMC Conforms to ETSI EN 301 489-1, ETSI EN 301 489-4,


EN 55022, EN 55024, Class A

LVD Conforms to EN 60950-1, IEC 60950-1, UL 60950, EN


50385

Spectrum Conforms to ETSI EN 302 217-2-2

GGS-000406-01E IPASOLINK VR2: SPECIFICATION

2016-04-20 Avea

Potrebbero piacerti anche