Sei sulla pagina 1di 13

Description and Maximum

Voltage power Price (COP) Installation type


brand (Kw)
CHARGE Point CT400 220 6-12 21'000.000 Cable type
Evlink (Schneider) 220 3-22 23'000.000 Cable type
Wattstation (GE) 220 15 33'000.000 Wireless

DIMENSIONING OF ELECTRICAL CHARGES, FOR 10 POINT STATIONS OF ELECTRICAL CHARGI


Points within the station Medium Charge (kW) Slow Charge (kW)
1 8
2 8
3 8
4 8
5 8
6 8
7 4
8 4
9
10
Total kW 60

Purchase Value kWh


Price (COP) $316

OBJECT POWER [W]


ELECTRIC SOCKET 400
LED TYPE BULBS 20

Station chargers
Common areas
Outdoor lighting
Total
STATIONS OF ELECTRICAL CHARGING
Motorcycles and Cycles

2
2
60

Sales Value AC kWh Vehicle Charge Value


$632 $31,600

QUANTITY
10
50

60kW
4kW
1kW
65kW
Power Power
Position Circuit Type Function Origin Purpose [W] factor
1-2 P-101 Biphasic EV Charger Power TD EVSE-01 8000 0.9
3-4 P-102 Biphasic EV Charger Power TD EVSE-02 8000 0.9
5-6 P-103 Biphasic EV Charger Power TD EVSE-03 8000 0.9
7-8 P-104 Biphasic EV Charger Power TD EVSE-04 8000 0.9
9-10 P-105 Biphasic EV Charger Power TD EVSE-05 8000 0.9
11-12 P-106 Biphasic EV Charger Power TD EVSE-06 8000 0.9
13 P-107 Monophase EV Charger Power TD EVSE-07 4000 0.9
14 P-108 Monophase EV Charger Power TD EVSE-08 4000 0.9
15 P-109 Monophase EV Charger Power TD EVSE-09 2000 0.9
16 P-110 Monophase EV Charger Power TD EVSE-10 2000 0.9
17 P-111 Monophase Shots (4 per breaker) TD TS 1000 0.9
18 P-112 Monophase Shots (4 per breaker) TD TS 1000 0.9
19 P-113 Monophase Shots (4 per breaker) TD TS 1000 0.9
20 P-114 Monophase Shots (4 per breaker) TD TS 1000 0.9
21 P-115 Monophase Illumination TD TS 1000 0.9
TOTAL (W) 65000
TOTAL (kVA) 72.22

CHARACTERISTICS DISTRIBUTION BOARD


Voltage [Vac] 220
Phases 3
No. Threads 5
No. Circuits 1
VA 71578.9
Voltage [Vac] 227.5
Power (3No.3/0+1/0N+2T)AWG
Main switch 3x250A
Power Origin General Table
%Reg 2,4%
Phases Breaker
Voltage [Vac] Caliber AWG-THNW 90°
L1[A] L2[A] L3[A] [A]
220 22.1 22.1 2x30 (2No.10+14T)AWG
220 23.4 23.4 2x30 (2No.10+14T)AWG
220 23.4 23.4 2x30 (2No.10+14T)AWG
220 23.4 23.4 2x30 (2No.10+14T)AWG
220 23.4 23.4 2x30 (2No.10+14T)AWG
220 23.4 23.4 2x30 (2No.10+14T)AWG
220 40.4 1x40 (1No.8+10N+12T)AWG
220 40.4 1x40 (1No.8+10N+12T)AWG
220 20.2 1x30 (1No.10+14N+14T)AWG
220 20.2 1x30 (1No.14+14N+14T)AWG
220 10.1 1x20 (1No.14+14N+14T)AWG
220 10.1 1x20 (1No.14+14N+14T)AWG
220 10.1 1x20 (1No.14+14N+14T)AWG
220 10.1 1x20 (1No.14+14N+14T)AWG
220 10.1 1x20 (1No.14+14N+14T)AWG
Power Power
Position Circuit Type Function Origin Purpose [W] factor
P-100 P-100 Triphasic General Rush Regulator TD 68000

CHARACTERISTICS DISTRIBUTION BOARD


Voltage [Vac] 220
Phases 3
No. Threads 5
No. Circuits 1
VA 71578.9
Voltage [Vac] 227.5
Power (3No.3/0+1/0N+2T)AWG
Main switch 3x250A
Power Origin General Table
%Reg 2,4%
Phases Breaker Caliber AWG-THNW 90°
Voltage [Vac]
L1[A] L2[A] L3[A] [A]
220 152.8 142.7 154.0 235.1 (3No.3/0+1/0N+2T)AWG
Circuit Type Function Origin Purpose Conductor

P-101 Biphasic EV Charger Power TD EVSE-01 3X10AWG

P-102 Biphasic EV Charger Power TD EVSE-02 3X10AWG

P-103 Biphasic EV Charger Power TD EVSE-03 3X10AWG

P-104 Biphasic EV Charger Power TD EVSE-04 3X10AWG

P-105 Biphasic EV Charger Power TD EVSE-05 3X10AWG

P-106 Biphasic EV Charger Power TD EVSE-06 3X10AWG

P-107 Monophase EV Charger Power TD EVSE-07 3X8AWG

P-108 Monophase EV Charger Power TD EVSE-08 3X8AWG

P-109 Monophase EV Charger Power TD EVSE-09 3X10AWG

P-110 Monophase EV Charger Power TD EVSE-10 3X10AWG

P-111 Monophase Shots (4 per breaker) TD TS 3X14AWG

P-112 Monophase Shots (4 per breaker) TD TS 3X14AWG

P-113 Monophase Shots (4 per breaker) TD TS 3X14AWG

P-114 Monophase Shots (4 per breaker) TD TS 3X14AWG

P-115 Monophase Reservation TD TS 3X14AWG

P-115 Monophase Illumination TD TS 3X14AWG

3No.3/0+1/0+
P-100 Three-phase General Rush TG TD 1No2AWG
CABLE GROUP DUCT OCCUPATION
Observations AREA AREA DUCT AREA (%)
(mm2) (mm2) (mm2)

ST-C "Enchanted" 108.4


(CENTELSA 201560)
217 1'' 556 39%
ST-C "Enchanted" 108.4
(CENTELSA 201560)

ST-C "Enchanted" 108.4


(CENTELSA 201560)
217 1'' 556 39%
ST-C "Enchanted" 108.4
(CENTELSA 201560)

ST-C "Enchanted" 108.4


(CENTELSA 201560)
217 1'' 556 39%
ST-C "Enchanted" 108.4
(CENTELSA 201560)
ST-C "Enchanted" 196.3
(CENTELSA 201562)
393 1'' 556 71%
ST-C "Enchanted" 196.3
(CENTELSA 201562)
ST-C "Enchanted" 108.4
(CENTELSA 201558)
217 1'' 556 39%
ST-C "Enchanted" 108.4
(CENTELSA 201558)
ST-C "Enchanted" 58.1
(CENTELSA 201552)
116 1'' 556 21%
ST-C "Enchanted" 58.1
(CENTELSA 201552)
ST-C "Enchanted" 58.1
(CENTELSA 201552)
116 1'' 556 21%
ST-C "Enchanted" 58.1
(CENTELSA 201552)
ST-C "Enchanted" 58.1 58 1'' 556 10%
(CENTELSA 201552)
ST-C "Enchanted" 58.1 58 1'' 556 10%
(CENTELSA 201552)

Soldaflex Flexible Cable 1151.2 2165 2'' 4761 45%


110
electric
sockets
Number of chargers 2 2 2 2 (motor
cycles
Length (m) 5 10 15 20 and
25
Caliber 10 10 10 8 bikes)
10

Type Biphasic Biphasic Biphasi


c Monophase
Monophase

Drop (%) 0.352 0.703 1.05 1.78 3.52

Hours Total
Maximum Voltage of
Equipment daily Quantity Power
power [W] [V] use [W]

Medium Charge 8000 220 12 6 48000


Slow Charge 4000 110 12 2 8000

Motorcycles and Cycles Charges 2000 110 12 2 4000

Common areas 4000 110 8 1 4000


illumination 1000 110 12 1 1000

Calculation of solar energy required


Site radiation [kWh /m2 /d] 4.82
Overall performance parameter of the installation 0.84
Coefficient of losses due to battery performance 0.05
Converter loss coefficient 0.05
Coefficient of miscellaneous losses (Joule effect, conductors, etc.) 0.05
Daily self-discharge coefficient 0.01
Number of days of installation autonomy 1.00
Daily battery discharge depth 0.70
Total daily energy solar system [w-h] 764000.00
Total energy required [w-h] 905289.89
Battery calculation
Number of days of installation autonomy 1.00
Battery voltage [V] 24.00
Discharge depth 0.70
Battery bank capacity for the Type I housing system [A-h] 53886.30
Individual battery capacity [A-h] 250.00
Total number of batteries for the solar system for cold chains 215.55
Calculation of inverters and controllers
Maximum current of the chosen panel [A] 8.27
Panel short circuit current chose [A] 8.81
Number of panels to install 685.00
System working voltage [V] 24.00
Controller Current [A] 5658.53
Controller and inverter power [W] 135804.77

Solar panels
Peak panel power [Wp] 305.00
Number of solar system panels for housing Type I 685.00

Sizing Installation Area [m2]


Solar Panel Area 1.94
Required Area 1324.96
Monophase

Total Daily
Energy [Wh]

576000
96000

48000

32000
12000
IN USE
Consumption # of Consumption Consumption/d CO2 in gr
Appliance (W/h)/ Elysium W/h / Elysium ay (9am-7pm; (produced/h)/
appliance Appliance Appliances 10 h) Appliance
Computers 300 20 6000 60000 234
Consoles 185 10 1850 18500 234

Virtual-reality 17,8 10 178 1780 100


simulators

Lights 15 500 7500 75000 39


(illumination)
Fridges 849 4 2547 25470 2500
Blender 300 4 1200 12000 200
TOTAL 1649 548 19275 192750 3307
WITHOUT USING
Consumption # of Consumption Consumption/d CO2 in Kg
Appliance (W/h)/ Elysium W/h / Elysium ay (7:30pm- (produced/month)/
appliance Appliance Appliances 8:30am; 13 h) Appliance
Computers 4 20 80 20 30.3
Consoles 0,22 10 2,2 10 30.3

Virtual-reality 0,15 10 1,5 10 20


simulators

Lights 3 500 1500 500 2


(illumination)

Fridges 849 4 3396 4 2500


Blender 0 4 0 4 0
TOTAL 856 548 4976 548 2582.6
IN USE
CO2
(produced)
/day
46800
23400

10000

195000

100000
8000
383200
WITHOUT USING

CO2/year
(produced)

363.6
363.6

240

24

30000
0
30991.2