Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
COMMUNICATIONS
Digital Outputs Modbus RS232, Modbus RS485, Modbus TCP/IP (optional) RS 485
ProTechTM Family of
Ethernet Tape-Based (903)
USB
Analyzers
Digital Inputs 4 dry contact, 4 wet
Analog Inputs 2 x 4-20 mA, user scalable, loop or self powered
Analog Outputs 6 x 4-20 mA, user scalable, loop powered
Relays 6 x SPDT relays, 5 amps @ 30 VDC or 8 amps @ 120/240 VAC
Please note: we work continuously to improve the performance of our products – all specifications are ©2015 Galvanic Applied Sciences, Inc.
subject to change without notice. BR5200 | June 2015 www.galvanic.com ⎜info@galvanic.com ⎜toll-free:+1.866.252.8470 ⎜+1.403.252.8470
Look Inside ... Choose the ProTech analyzer that’s right for your Selected Industries &
specific application needs Applications
Ultra-high-sensitivity, lowest total cost of operation – the Galvanic continues to lead the way in innovative, cost-effec-
ProTech family of tape-based analyzers can improve both tive tape-based analyzer systems
~~Chemical
quality – and economics PROTECH H2S/TS ANALYZER W D1 D2
Precision Optical Encoder ~40 CFR 60 Subpart Ja
The ProTech system’s optical encoder en- H2S over-range capability flare gas emissions
Galvanic has been a long-time leader in tape-based analyzers, and con- ~ ~ ~
sures exact spacing between stains and monitoring
tinues to innovate, designing and building cost-effective systems that 5 ppb sensitivity level ~ ~ ~
keeps track of tape usage. ~~Food & Beverage
optimize performance in the harshest monitoring environments. Gal- ASTM D4084-94 & D4323-84 ~ ~ ~
vanic’s ProTech analyzers deliver fast, extremely sensitive and accurate Advanced Digital ~Food-grade CO2
Total Sulfur capability (ASTM D4468-95) ~ ~
analysis of H2S and total sulfur, arsine, phosphine, or phosgene, depend- Sensor ~~Natural Gas Pipeline
CSA Class 1, Div 1, Groups B,C & D, T3 ~
An advanced digital sensor puts the AD ~Custody transfer
ing on which analyzer you choose. CSA Class 1, Div 2, Groups B,C & D, T3
right at the measurement point, eliminating ~ ~
~Odorant monitoring
Rugged and reliable, ProTech analyzers are capable of very low detection limits and noise associated with transmiting analog Multi-stream capability ~ ~
outperform all other analytical methods in the critical application range of 0 to 15 signals. ~~Natural Gas
Solor power option (not available with Total Sulfur option) ~ ~ ~
Processing
ppmv. Whether you’re on site or around the globe, you can rest assured. With easy
remote-access capability and fast, accurate analyte-specific measurement – you ~40 CFR 60 Subpart Ja
Proprietary Membrane Humidifier
have all you need to monitor critical parameter levels to improve product quality PROTECH ARSINE ANALYZER W D1 D2 flare gas emissions
The ProTech system’s proprietary membrane monitoring
and lower costs, ensure pipeline, equipment, and public safety, or meet regulatory 5 ppb sensitivity level
humidifier reduces dead volume for faster ~ ~ ~
and contractual compliance targets. Galvanic’s ProTech analyzers are interference ~NG plant inlet/outlet
response times. CSA Class 1, Div 1, Groups B,C & D, T3 ~
free and are not matrix dependent. The low total cost of ownership marks the Pro- gas
Tech series as the highest-value tape-based analyzers on the market today. CSA Class 1, Div 2, Groups B,C & D, T3 ~
External-Keypad-Driven Display ~NG sweetening
Multi-stream capability ~ ~
An intrinsically safe external keypad allows
~~Oil & Refining /
the user to configure and monitor the ana-
Flexible, headache-free Petrochemical
lyzer without declassifying the area – a fea-
installation & operation ture unique to Galvanic systems. It provides
PROTECH PHOSPHINE ANALYZER W D1 D2 ~40 CFR 60 Subpart Ja
Galvanic analyzers custom-configured at 5 ppb sensitivity level
flare gas emissions
full menu access for the high-resolution dis- ~ ~ ~
the factory to integrate seamlessly into your monitoring
play, enabling at-a-glance status and results. CSA Class 1, Div 1, Groups B,C & D, T3
existing infrastructure. Galvanic’s expert ~
~Catalyst protection
support team will calibrate one analyzer or CSA Class 1, Div 2, Groups B,C & D, T3 ~
~Feedstock/fuel gas
dozens to your exact specifications, mim- Dual Redundant Power Supplies & Multi-stream capability ~ ~ monitoring
icking sample conditioning and outputs of Optional Ethernet Connection
your current system, as required. ~~Pharmaceutical
Unparalleled flexibility enables ProTech analyz-
PROTECH PHOSGENE ANALYZER W D1 D2 ~Stack emissions for
ers to be configured to meet any application
Retire old analyzers individually as neces- reporting
need. Dual redundant power supplies (located 5 ppb sensitivity level ~ ~ ~
sary, or start an entire new line in the most
inside the analyzer) allow the unit to be run on ~Industrial hygiene /
cost-effective way possible – Galvanic makes CSA Class 1, Div 1, Groups B,C & D, T3 ~
either AC or DC power, or to have back up DC worker safety
it easy to standardize your training pro- CSA Class 1, Div 2, Groups B,C & D, T3 ~
power; optional Ethernet connection allows users
tocols, operating procedures, and service ~Organic synthesis –
to connect the analyzer on a local area network for remote opera- Multi-stream capability ~ ~
processes at all your facilities worldwide. phosgene
tion and troubleshooting.