PROTECH SPECIFICATIONS Galvanic Applied Sciences Inc. solves


PERFORMANCE critical process-analysis and measure-
Zero drift +/- 2% F.S ment problems for customers world-
Span Drift +/- 2% F.S. wide with our full line of rugged,
Accuracy +/- 1% F.S. for ranges 1 to 50 ppm fit-for-purpose gas- and liquid-mea-
+/- 1.25% F.S. for ranges > 50 ppm surement systems. We engineer all of
+/- 1.5% F.S for ranges 0.5 to 1 ppm
our systems and components to deliver
+/- 2.5% F.S. for ranges < 0.5 ppm
uncompromising accuracy, reliability,
Repeatability +/- 1% F.S. for ranges 1 to 50 ppm
and long-term value to users, even in
+/- 1.25% F.S. for ranges > 50 ppm
+/- 1.5% F.S for ranges 0.5 to 1 ppm the most-challenging process environ-
+/- 2.5% F.S. for ranges < 0.5 ppm ments. That’s why multinationals and
Sensitivity 1% F.S. small companies alike turn to us again
Linearity +/- 2% F.S. and again – they count on our atten-
Response time: 30 seconds to alarm (excluding sample system) tion to detail, applications know-how,
and exacting quality standards. We
ENVIRONMENT
work with customers to tailor each sys-
Ambient temperature 0°C to 50°C (32°F to 122°F)
tem to meet their site-specific process
Dimensions H2S: 686 mm W x 838 mm H x 318 mm D (27” W x 33” H x 12.5” D)
With TS option: 686 mm W x 1219 mm H x 318 mm D ( 27” W x 48 “ H x requirements and to provide unpar-
12.5 D) alleled support through installation,
Weight H2S Div 1: 27.2 kg (60 lbs) training, and long-term product main-
H2S Div 2: 20.4 kg (45 lbs) tenance. A private company headquar-
TS Div 1: 36.3 kg (80 lbs)
TS Div 2: 29.4 kg (65 lbs) tered in Calgary, AB, Canada, with a
facility in Lowell, MA, USA, Galvanic
UTILITIES
supports a global network of dedicat-
Power & H2S:10-32 VDC, 10 watts + 1.5 watts per solenoid
consumption H2S: 90-240 VAC, 50/60 Hz, 10 watts + 17 watts per solenoid ed sales and service engineers, as well
TS: 90-240 VAC, 50/60 Hz, 250 watts + 17 watts per solenoid as value-added distributors to serve
Sample flow 100 cc/min, 1 Barg (0.21 SCFH, 15 psig) the needs of customers.
Gas requirements TS Option: Hydrogen 180 cc/min, 1 Barg (0.38 SCFH, 15 psig)

COMMUNICATIONS
Digital Outputs Modbus RS232, Modbus RS485, Modbus TCP/IP (optional) RS 485
ProTechTM Family of
Ethernet Tape-Based (903)
USB
Analyzers
Digital Inputs 4 dry contact, 4 wet
Analog Inputs 2 x 4-20 mA, user scalable, loop or self powered
Analog Outputs 6 x 4-20 mA, user scalable, loop powered
Relays 6 x SPDT relays, 5 amps @ 30 VDC or 8 amps @ 120/240 VAC

APPROVALS & CERTIFICATIONS


CSA (C, CUS) Class 1 Division 1, Groups BCD
CSA (C, CUS) Class 1 Division 2, Groups BCD
ATEX Zone 1
CE

Please note: we work continuously to improve the performance of our products – all specifications are ©2015 Galvanic Applied Sciences, Inc.
subject to change without notice. BR5200 | June 2015 www.galvanic.com ⎜info@galvanic.com ⎜toll-free:+1.866.252.8470 ⎜+1.403.252.8470
Look Inside ... Choose the ProTech analyzer that’s right for your Selected Industries &
specific application needs Applications
Ultra-high-sensitivity, lowest total cost of operation – the Galvanic continues to lead the way in innovative, cost-effec-
ProTech family of tape-based analyzers can improve both tive tape-based analyzer systems
~~Chemical
quality – and economics PROTECH H2S/TS ANALYZER W D1 D2
Precision Optical Encoder —~40 CFR 60 Subpart Ja
The ProTech system’s optical encoder en- H2S over-range capability flare gas emissions
Galvanic has been a long-time leader in tape-based analyzers, and con- ~ ~ ~
sures exact spacing between stains and monitoring
tinues to innovate, designing and building cost-effective systems that 5 ppb sensitivity level ~ ~ ~
keeps track of tape usage. ~~Food & Beverage
optimize performance in the harshest monitoring environments. Gal- ASTM D4084-94 & D4323-84 ~ ~ ~
vanic’s ProTech analyzers deliver fast, extremely sensitive and accurate Advanced Digital —~Food-grade CO2
Total Sulfur capability (ASTM D4468-95) ~ ~
analysis of H2S and total sulfur, arsine, phosphine, or phosgene, depend- Sensor ~~Natural Gas Pipeline
CSA Class 1, Div 1, Groups B,C & D, T3 ~
An advanced digital sensor puts the AD —~Custody transfer
ing on which analyzer you choose. CSA Class 1, Div 2, Groups B,C & D, T3
right at the measurement point, eliminating ~ ~
—~Odorant monitoring
Rugged and reliable, ProTech analyzers are capable of very low detection limits and noise associated with transmiting analog Multi-stream capability ~ ~
outperform all other analytical methods in the critical application range of 0 to 15 signals. ~~Natural Gas
Solor power option (not available with Total Sulfur option) ~ ~ ~
Processing
ppmv. Whether you’re on site or around the globe, you can rest assured. With easy
remote-access capability and fast, accurate analyte-specific measurement – you —~40 CFR 60 Subpart Ja
Proprietary Membrane Humidifier
have all you need to monitor critical parameter levels to improve product quality PROTECH ARSINE ANALYZER W D1 D2 flare gas emissions
The ProTech system’s proprietary membrane monitoring
and lower costs, ensure pipeline, equipment, and public safety, or meet regulatory 5 ppb sensitivity level
humidifier reduces dead volume for faster ~ ~ ~
and contractual compliance targets. Galvanic’s ProTech analyzers are interference —~NG plant inlet/outlet
response times. CSA Class 1, Div 1, Groups B,C & D, T3 ~
free and are not matrix dependent. The low total cost of ownership marks the Pro- gas
Tech series as the highest-value tape-based analyzers on the market today. CSA Class 1, Div 2, Groups B,C & D, T3 ~
External-Keypad-Driven Display —~NG sweetening
Multi-stream capability ~ ~
An intrinsically safe external keypad allows
~~Oil & Refining /
the user to configure and monitor the ana-
Flexible, headache-free Petrochemical
lyzer without declassifying the area – a fea-
installation & operation ture unique to Galvanic systems. It provides
PROTECH PHOSPHINE ANALYZER W D1 D2 —~40 CFR 60 Subpart Ja
Galvanic analyzers custom-configured at 5 ppb sensitivity level
flare gas emissions
full menu access for the high-resolution dis- ~ ~ ~
the factory to integrate seamlessly into your monitoring
play, enabling at-a-glance status and results. CSA Class 1, Div 1, Groups B,C & D, T3
existing infrastructure. Galvanic’s expert ~
—~Catalyst protection
support team will calibrate one analyzer or CSA Class 1, Div 2, Groups B,C & D, T3 ~
—~Feedstock/fuel gas
dozens to your exact specifications, mim- Dual Redundant Power Supplies & Multi-stream capability ~ ~ monitoring
icking sample conditioning and outputs of Optional Ethernet Connection
your current system, as required. ~~Pharmaceutical
Unparalleled flexibility enables ProTech analyz-
PROTECH PHOSGENE ANALYZER W D1 D2 —~Stack emissions for
ers to be configured to meet any application
Retire old analyzers individually as neces- reporting
need. Dual redundant power supplies (located 5 ppb sensitivity level ~ ~ ~
sary, or start an entire new line in the most
inside the analyzer) allow the unit to be run on —~Industrial hygiene /
cost-effective way possible – Galvanic makes CSA Class 1, Div 1, Groups B,C & D, T3 ~
either AC or DC power, or to have back up DC worker safety
it easy to standardize your training pro- CSA Class 1, Div 2, Groups B,C & D, T3 ~
power; optional Ethernet connection allows users
tocols, operating procedures, and service —~Organic synthesis –
to connect the analyzer on a local area network for remote opera- Multi-stream capability ~ ~
processes at all your facilities worldwide. phosgene
tion and troubleshooting.