Sei sulla pagina 1di 4

Enter liquid head 2248 mm

Enter the density of fluid 1000 kg/m3

Dimension of panel
Diameter of panel 2248 mm
Thickness of panel, tp 6 mm

Spacing of stiffeners
Width of spacing 570 mm
Length of spacing 570 mm
Size of stiffener
Thickness of stiifener 6 mm
Width of stiifener 50 mm

Length of panel considered in strength calculation, l 192 mm


(Minimum of stiffener spacing or 32 x tp)

Material Properties
MOC of Panel SA/IS 2062 Gr.EB 250
MOC of stiffener SA/IS 2062 Gr.EB 250

Yield stress of panel 250 N/mm2


Yield stress of stiffener 250 N/mm2

Allowable bending stress of panel 167.5 N/mm2


Allowable bending stress of stiffener 167.5 N/mm2

Calculations

1) Hydrostatic press. on the panel, Pn 0.0221 N/mm2

2) Bending Moment on the stiffener + panel composite 510505 N.mm

3) Calculation of C.G. for composite


Description Area y h Ah2 I
Panel 1152 3 5.79 38555 3456
Stiffener 300 31 -22.21 148050 62500
Summation 1452 Itotal

Centre of gravity from Inside of Panel, CG 8.79 mm

4) Stresses induced

Stress in Panel 17.76 N/mm2 d= 0.6299

Stress in Stiffener 95.44 N/mm2 y= 0.12


5) Shear load, V 3582 N V= 165.65

6) Size of weld required

Size of weld envisaged 5 mm


Enter number of welds 2

Required weld leg size 0.002748 inch I= 0.60678


(Considering E7018 Rod)

Required size of weld 0.069791 mm


Itotal = I + Ah2
42011
210550
252561 mm4

inch

inch
lb

inch4