Sei sulla pagina 1di 1

A CONSTRUCTION LJS 12/11/2014

B REVISED AS PER LATEST ARCHITECT DRAWING LJS 12/01/2017


R3

1K
2525

2525
LOWER LEVEL LAYOUT PLAN - DP STAIRCASE UPPER LEVEL LAYOUT PLAN - DP STAIRCASE
SCALE 1 : 30 SCALE 1 : 30

300
200 THK SLAB CASTED
75 150 75 15mm THK NON SHRINK GROUT
1200 3050 40 220 40 16mm THK BASE PLATE

BASE PLATE TO BE SEALED

40
300 x 300 x 16mm THK WITH NON SHRINK GROUT

200
75
M.S PLATE

110
150 x 150 x 6mm THK SHS
SHS 150x150x6mm

250
300

150
100
FULL STRENGTH WELD ADDITIONAL BEAM TO BE CONSTRUCTED TO
BUTT WELDING
RECEIVE STEEL SHS DUE TO LEVEL CAN'T MEET

110
ALL BOLTS TO BE TACK WELD 230
UPPER FLOOR
FFL DETAIL 'A'

75

40
GRADE 8.8 BOLT

150
HILTI HIT-HY 200-R with HIT-V
75mm SET INTO RC WALL SHS 150x150x6mm 150
OR APPLIED EQUIVALENT

SECTION 2-2
DETAIL 'B' SCALE 1:5 DETAIL 'A' - DP STAIRCASE
SCALE 1 : 10

300
3300

75 150 75
40 220 40

40
300 x 300 x 16mm THK

75
M.S PLATE

110
150 x 150 x 6mm THK SHS
16mm THK BASE PLATE 15mm THK NON SHRINK GROUT
300

150

LOWER FLOOR
FFL DETAIL 'C' FULL STRENGTH WELD
110

75
ALL BOLTS TO BE TACK WELD
150x150x6mm THK SHS
75

RESIDENTIAL
40

GRADE 8.8 BOLT


HILTI HIT-HY 200-R with HIT-V RC WALL STEEL STAIRCASE DETAILS & SECTION (TYPE DP)
75mm SET INTO RC WALL
OR APPLIED EQUIVALENT

SECTION 3-3 DETAIL 'B' - DP STAIRCASE JURUTERA PERUNDING TEKADMAJU SDN BHD
SCALE 1:5 E-5-27, IOI Boulevard,
SCALE 1 : 10
Jalan Kenari 5, Bandar Puchong Jaya,
SECTION 1-1 47170 Puchong,
Selangor Darul Ehsan, Malaysia.
DP STAIRCASE Tel : 603 - 8075 6565
SCALE 1 : 30 500 Fax : 603 - 8071 5868
50 200 200 50
BUTT WELDING
40 210 210 40

150
SHS 150x150x6mm
40

150
75

500 x 300 x 16mm THK


M.S PLATE

SHS 150x150x6mm
150 x 150 x 6mm THK SHS END CAP
300

220
150

FULL STRENGTH WELD 50mm THK FINISHES (TO ARCHI)

ALL BOLTS TO BE TACK WELD


125

75

150
THIS DRAWING OR ANY PART OF IT SHALL NOT BE REPRODUCED IN ANY FORM
75

WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER.


40

GRADE 8.8 BOLT


CONTRACTOR MUST CHECK ALL DIMENSIONS ON SITE. ANY DISCREPANCIES
HILTI HIT-HY 200-R with HIT-V
75mm SET INTO RC BEAM MUST BE REPORTED IMMEDIATELY TO THE ENGINEER BEFORE PROCEEDING
RC BEAM 15mm THK NON SHRINK GROUT
OR EQUIVALENT CHOO/MEZA/TC LJS
MAI/NIK/AMI C/JPT/JP039/
SECTION 4-4 DETAIL 'C' - DP STAIRCASE FOR CONSTRUCTION AUG 2013
SCALE 1:5 SCALE 1 : 10
C/JPT/JP039/S/R/SC/DP(ST)/DT/001 B