Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Monitoring Systems
Engineering
&
Design
a technical solution to
meet every need…
Cemtek Environmental Inc.
3041 S. Orange Ave.
Santa Ana, CA 92707
800-400-0200
www.cemteks.com
© 2014 Cemtek Environmental, Inc.
Fractional Distillation and
Chemical Processing CEMS
Most units utilized in fractional distillation and chemical processing
utilize heaters burning refinery and/or natural gas and require CEMS.
Process heaters may utilize Selective Catalytic Reduction (SCR) for
NOX control.
Data Acquisition
How will CEMS data be handled and stored?
Data Acquisition System (DAS) for data handling
and storage.
DCS to handle CEMS data NOX & O2 CEMS on refinery heater
Co-mingling of data issues with stack mounted NH3 measurement
Most refinery processes subject to 40CFR Part 60 using TDL (tunable diode laser)
compliance. Some processes may be large enough to be
subject to 40CFR Part 75, requiring data substitution
routines.
Cogeneration Plant
© 2014 Cemtek Environmental, Inc.
Cogeneration Plant CEMS
Cogeneration Plant
© 2014 Cemtek Environmental, Inc.
Cogeneration Plant CEMS
Data Acquisition
Stand alone data acquisition system (DAS) typically
utilized for data manipulation and storage.
System may be subject to 40CFR Part 60 or 40CFR
Part 75, depending on the amount of power sold to the
grid.
Hydrogen Plant
© 2014 Cemtek Environmental, Inc.
Hydrogen Plant CEMS
Data Acquisition
How will CEMS data be handled and stored?
Data Acquisition System (DAS) for data handling
and storage.
DCS to handle CEMS data
Co-mingling of data issues
Most refinery processes subject to 40CFR Part 60
compliance. Some processes may be large enough to be
subject to 40CFR Part 75, requiring data substitution
routines.
Most Sulfur Recovery Units (SRU) exhaust waste acid gas through a
Tail Gas Incinerator or Caustic Scrubber and require CEMS.
Tail Gas Incinerator and Caustic Scrubber CEMS are the most difficult
refinery CEMS applications due to variable fuel compositions and wide
range of expected emissions.
CEMS Design Considerations
Data Acquisition
How will CEMS data be handled and stored?
Data Acquisition System (DAS) for data handling
and storage.
DCS to handle CEMS data
Co-mingling of data issues
Most refinery processes subject to 40CFR Part 60
compliance. Some processes may be large enough to be
subject to 40CFR Part 75, requiring data substitution
routines.
Refinery Flare
CEMS Design Considerations Continued
Flare CEMS
Wide range of sulfur emissions.
Location of monitoring equipment outside of radiation zone.
Worker safety while working with % level gases.
Stack flow measurement required, typically on flare gas header. (Mass emissions reporting)
© 2014 Cemtek Environmental, Inc.
Flare CEMS
CEMS Shelter
Sample Probe
Foundation
Access Platform
Utility Connections
Hot Tap Probe Port
Plant Communications
Flashback Seal
Drum Flare Stack
Liquid Knockout Drum
© 2014 Cemtek Environmental, Inc.
Flare CEMS
Refinery
Projects
a technical solution to
meet every need…
Cemtek Environmental Inc.
3041 S. Orange Ave.
Santa Ana, CA 92707
800-400-0200
www.cemteks.com
© 2014 Cemtek Environmental, Inc.
Cemtek Environmental
Refinery Experience
Cemtek Environmental
Bronze Safety Award Recipient
2007 & 2008
SCAQMD Refinery
RECLAIM CEMS
Application
Cemtek supplied a new CEMS for monitoring sulfur recovery unit tail gas
incinerator emissions. The new CEMS was integrated into the existing Class 1,
Div 2 CEMS shelter measuring NOX, SO2, CO, wet & dry O2, and stack flow.
Also provided was a custom built, 18 foot multi-point heated probe for
© 2014 Cemtek Environmental, Inc. measurement of a stratified stack.
Cemtek Environmental
Refinery Experience
Northwest Refinery Gas Chromatograph Application
SCAQMD Refinery
RECLAIM CEMS
Application
SCAQMD Refinery
RECLAIM CEMS
Application
SCAQMD Refinery
RECLAIM CEMS
Application
Southwest Refinery O2
Process Monitoring
Application
Southwest Refinery O2
Process Monitoring
Application