METHOD STATEMENT SUBMITTAL


FROM: Mclaren Construction Ltd. ITO: GHD

Rl!fifrence Number
Subject: Installation of Light Fittings
Project ID Client Ref. MCL-ME-A-MST-000014
M1467 Subcontractor
Note Comments shall be noted on actual drawing, with stamp
Ref. GEMC-ME-A-MST-005
Dlsdpllne:

D Arc"-lt:ectµral D S�ructural • M,l!,P. D External wo_rks Dother (specify ,1...........


Ref.
No. Document Ref. No Rev Title Cont. Status
,, Drawing

. 00
1
Method Statement and Risk Assessment for Installation
I
GEMC-ME-A-MST-005
of Light Fittings
Consultant Review Sign Off Returh-ed tb C:ontractor: Doaume),t Stat\j�
Consultant's
Client Representative Approved Approved as Noted
Name:
Reviewer's
Name: Revise and Submit Records
Name:
Reviewer's
Sign: Final Status/ Representative
Signature

Date: Date: 07-05-2019 Signature: Date:

This section to be completed by revlewer: Consultant's Received Date


Comments:
GHD Global Pty Ltd.
DOCUMENT / DRAWINGS
REVIEW STAMP

Electrical: Status: Approved as Noted A Accepted

) 1.Remove irrelevant documents from method statement. B Accepted as noted


Not Approved - Revise/
C
2.Light Fittings ITP and check list to be provided for review and approval CHECKED BY:
Resubmit
DATE:
Baihram Majeed 07-05-19
Documents receiving an A or B status are considered to
conform with the design intent but does not mean acceptance
of dimensions, sizes or weights, nor does it relieve the
Subcontractor/Consultant from any responsibility for
errors, ommisions and/or compliance with obligations an/or
responsibility of the Contract and/or Consultancy agreement.

I
Baihram Majeed Site Engineer

Name: I Designation: Signature: Com,'nv styt,p & Date


0n behalf of MX;Lar�n Const�uGtlon Ltd.:
Signature: Signature: Signature: ,�c;;,.........
,.._
- � Signature��
/ /l

Safety Manager: Joby John HSQE: Jamie Selway Constr.fcm:m Man":tger:Prabhu Project Nfan�uke Watson
Originate� Genfocus EleGtromechanlcal Contra-ctlng Est, McL Received Date Stamp McL Dlatrlbutlon
Name: Syed Faisl Ahmed Client Others:
Designation
7.02.2019
ME Manager I Consultant J

1 I
Date: Signature Originator
Corrections or comments made receive to submlttals during this review do not rel/eve the contractor from compliance with the requirements of the contract
documents
p

Page 1 of 1 13S%i5ii
I
1

I
McLAREN I GUlr
RELATED
North and South Car Park Connectivity Corridors, and Concourse Link Bridge
Al Maryah Island, Abu Dhabi, United Arab Emirates

METHOD STATEMENT SUBMITTAL


REFERENCE No. : GEMC·ME·A·MST·005 I REV.00 DATE:26-02-2019

Method Statement and Risk Assessment for Installation of Light


SUBJECT: PROJECT No.: M1467
Fittings

TO: McLaren Construction Ltd - Abu Dhabi I FROM: Genfocus Electromechanlcal Contracting EST

n
Dlsclpl/ne :
O Architectural D Structural • M.E.P D Interiors 0 External D Other (state)

DOCUMENT DESIGNATION:

NO.OF
NO. DESCRIPTION/ TITLE DOCUMENT NO. REVISION
COPIES
Method Statement and Risk Assessment for
l GEMC-ME-A-MST-005 00 1
Installation of Light Fittings

FOR SUBCONTRACTOR:
NAME: SYED FAISL AHMED DESIGNATION: MEPMANAGER SIGNATURE:
�� <� 7
CO�IB8CIOB'S ��MMENIS1

w.-
DOCUMENT STATUS:
Approved (Work may proceed)
- Approved with Comments (Work may proceed subject to Incorporation of comments Indicated)
D C - Revise and Resubmit (Work may not proceed need to resubmit)

CONTRACTOR'S REPRESENTATIVE:
NAME: ______ DESIGNATION: _____ SIGNATURE: ______ DATE: ___

Corre,rlons or comments made via submlttals during this review do n from comp/lance with the requirements of
the Conrrucr Documents. -s>

QMS009 {UAE) 01/19 - Rev.13 (AMC)


I GUU
-- ---- --

' McLAREN
RELATED
North and South Car Park Connectivity Corridors, and Concourse Link Bridge
Al Maryah Island, Abu Dhabi, United Arab Emirates

METHOD STATEMENT COMMENTS SHEET FORM


REFERENCE No. GEMC-ME-A-MST-005 I REV. : 00 DATE :26·02-2019
Method Statement and Risk Assessment for
SUBJECT: PROJECT No.: Ml467
lnstallatlon of Light Fittings
Please find enclosed:
No.of
ITEM DRAWING/DOCUMENT NO. REV DESCRIPTION
Coples
Method Statement and Risk Assessment for Installation of
1 1 M1467- GEMC·ME·A·MST·OOS 00
Light Fittings

Review by N11me SI nature D11te Y/N/NA


Project M.in.iger Luke Watson
)
Construction Manager PRABU
HSE Manager Joby John

QA/QC Engineer

Others

This section to be completed by Construction Manager:


D A • Approved oved with Comments D C- Revise & resubmit
Work rnily proceed subject to Incorporate
of commenh indlc;ited

Designation: Signature:

This section to be completed by HSE M1n1aer:


D A- Approved V'B- Approved with Comments 0 C- Revise & resubmit
Work may proceed subject to Incorporate
. .)
Work mal proceed
of comments indlc ted
/p;"
_\
Work may not proceed
Joby John L'tl l,D
Name: f u
Safety Manager
Designation: f
,,, � n_ J\c"x
Sig�\
� "")I\ u I ( )f.
qatt!:
This section to be completed by QA/QC Engineer:
D A • Approved D B - Approved with Comments D C- Revise & resubmit
Work may proceed subject to Incorporate
Work may proceed Work may not proceed
of comments Indicated

Name: Design,ition: Sign.iture: Date:


Originator Subcontractor:
SYED FAISAL AHMED MEPMANAGER . �
t:.
..." ,;
26-Feb-2019
Name: Designation: Signature: Date:

QMS012 (UAE) 01/19- Rev.13 (AMC) Page 1 of 1 Method Statement Comments Sheet Form
, McLAREN
--------�

RAMS EVALUATION SHEET


North and South Car Park Connectivity
Corridors, and Concourse Link Bridge
Project name Project No M1467
Al Maryah Island, Abu Dhabi, United
Arab Emirates
Method Statement and Risk Genfocus
Activity Assessment for Installation of Light Subcontractor Electromechanlcal
Fittings Contracting Est.
Anticipated start Issue/Revision GEMC-ME-A-MST-005
30-04-2019 Rev-00
date number . ·--

Status Comment
These RAMS are deemed to cover th@ requirements of MCL as per the MCL RAMS Pro-Forma (SAF 072) and are
A
suitable for purpose
B All MCL comments n@@d to b@ incorporated Into the RAMS before they can be accepted.

C Not accepted for implementation. Resubmission required.


Please note - ALL comments MUST be Incorporated within the RAMS before It will be accepted for Implementation. once
Status A achieved, It does not relieve the contractor of their contractual obligations and ownership of the RAMS nor
compliance with local /federal laws.
Status Date Received Date Sent

l
A

� ·2,bie?/ ( L') ') n O'-r\ '( (�

'?___b I tY'l-1I f q
,
I I

\� '7J)
I I
I 'T·

For MCL Use ONLY


Appraisal Signatories Position Signature Date

The RAMS documentation submitted by the subcontractor should include the following
RISK ASSESSMENTS Yes• NoO PERSONAL PROTECTIVE EQUIPMENT Yes• NoD
COSHH {MSDS) YesD No• EMERGENCY ARRANGEMENTS Yes• NoD
FULL DESCRIPTION OF METHODOLOGY AND MATERIALS, WASTE REMOVAL
SEQUENCE OF WORK Yes• NoD Yes• NoD
HOUSEKEEPING ANO STORAGE
ACCESS / EGRESS Yes• NoD ENVIRONMENTAL Yes• NoD
OCCUPATIONAL HEALTH Yes• NoD LOGISTICS Yes• NoD
WORK AT HEIGHT Yes• NoD TECHNICAL INFORMATION YesD No.
COMMUNICATION/MANAGEMENT/
PLANT / EQUIPMENT/TOOLS Y@s. No CJ Yes• NoD
TRAINING
PERMITS Yes• NoD DIAGRAMS/CERTIFICATES YesD No•
Please note - referring to the RAMS Pro Forma (SAF 072) wlll assist In what Information Is needed

RAMS Evaluation_ RAMS EVALUATION SHEET


McLAREN

Comments Initials

. )

Continuation Sheets used YesD NoD

RAMS Evaluation_ Page 2 of 2 RAMS EVALUATION SWEET


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS)
----
MCLAREN'

)
Method Statement and Risk Assessment for
Installation of Light Fittings, at AMC Connectivity
Corridors & Concourse Bridge Project, Maryah
Island,
ABUDHABI
Project No-M- 1467

Document Ref No: GEMC-ME-A-MST-005

M@thod Statement Title llnstallatlon of Lleht Flttlnes Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal fApproved By I Revision Date:

SAF-098 (UAE) 09/16 Rev G lof 10 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN
- -----
-

Project name AMC Connoctlvlty Corridors & Concourse Brldee Project PrllJCct No Ml467
Main Contractor Mclaren Construction Ltd. Document No GEMC-ME-A-MST-005
Tltlc/THk Installation of Light Fittings Revl,lon No 00
Document
Date of Issue 23/02/2019 Prc1medBv
Syed Faisal
Duration of
Proposed start date 30/04/2019 task 30 DAYS

Contents
Section A Register of Revisions
Section B Scope of Works to be undertaken:
Section C Location of the Project
Section D Location of the Works to be Undertaken with the Project
Section E Site Access/Egress and Access to the Work Zone
Section F Emergency Contacts Details and Procedures:
Section G McLaren Site Specific HSE Safety Induction:
Section H Welfare facllltles:
Section I Personal Protective Equipment
Section J Plant/Equipment and tools to be Used
Section K Materials To be used.
Section L Communication/Toolbox Talks/Training Requirements:
Section M Works Permits
Section N Environmental and Waste Management:
Section O Programme for the Works:
Section P Housekeeping and Storage:
Section Q Hygiene and cleanliness
Section R Working at Height
Section S Occupational Health
Section T Sequence of Works/Activities

Appendices

Appendix A Site Logistic Plans and Other Design Information Relative to the Works
Appendix B Crisis/Emergency Plan
Appendix C COSHH Assessments and Material Data Sheets (to be provided by Subcontractor)
Appendix D Risk Assessments (to be provided by Subcontractor)
Appendix E Technical Information (to be provided by the Subcontractor)
Appendix F Risk Assessment

Method Statement Title linstallatlon of Light Fittings Doc Ref No: K,EMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: IOO
Prepared By �ycd Faisal jAPProved By I Revision Date:
SAF•098 (UAE) 09/16 Rev G 2 of 19 RISK ASSESSMENT METHOD STATEMENT
r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN i
----- -

Section A - Register of Revisions

Revision D3tC Rn5on for Amondmont Amended By Signature Has this amendment been briefed
No (Name) to the operatives Involved and
have the operatives signed the
register.

This method statement has been prepared In conjunction with the following documents;
1. OSHAD regulation and requirements
2. OHSAD- Code of Practices, HSE Regulations, Technical Guidelines, Mechanisms
3. GR HSE Guidelines and Requirements
4. Federal Environmental Authority Law No 24/1999 and its supplements.
5. Federal Labour Law No 8
6. Articles (3,4,5, 7) Local Law No 21/2005 (Waste Management)
7. McLaren SHE Procedures
8. McLaren's site specific SHEQ Plan (including TMMS, SWMP, EPP).
9. McLaren's Integrated Management System Policy Statement (IMS).

Section B- Scope of Works to be undertaken:


The work Describes the installation activity of light fittings at Concourse Bridge, North and South Connectivity
Corridors.
The following Critical Hazards have been Identified during the preparation of the scope of works, please refer to
the Risk Assessments within Appendix D.

1. Manual Handling Injuries


2. Slip Trips and Falls
3. working at Height/ Ladders
4. Fall from Height
5. Electrical Hazard
6. Struck by Objects
7. Use of ladders
8. Falling objects

Method Statement Title linstallatlon of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �ycd Faisal JApproved By I Revision Date:
SAF•098 (UAE) 09/16 Rev G 3 of 19 RISK ASSESSMENT METHOD STATEMENT
r. GULF­
RELATEO RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN I
-----�

Section c- Location of the Pro ect


Location of the Project;
Our project is located is located AMC CONCOURSE BRIDGE in between Almaryha and Galleria Mall as marked
below.

. )

Method Statement Title !installation of Light Fittings Doc Ref No; GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: Kio
Prepared By �yed Faisal jApproved By I Revision Date:

SAF-098 (UAE} 09/16 Rev G 4 of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN
1

Section D- Location of the Works to be Undertaken within the Project

. )

Method Statement Title installation of Light Fittings Doc Ref No: EMC·ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No:
Prepared By yed Faisal pproved By Revision Date:

SAF-098 (UAE) 09/16 Rev G Sof 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN:
------

Section E- Site Access/Egress and Access to the Work Zone

Entrance to the Site will be from Gate no 1 as per attached drawing.

...,........ . ,
.,_,

4.
j

,-,

ft.AfllDrtf.O{

f3\lltl
A,C,. "fll".1--'IOl-i
- r•.tt111»KNflK.Mi1orr I•
: �·�:�t�,.�fi"''°':t.1
.._"1!!4-0\t,,t1\.'rl

M@thod Statement Title Jinstallatlon of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: IOO
Prnparnd By �yed Faisal JApproved By I Revision Date:

SAF•098 (UAE) 09/16 Rev G 6of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN
-

Section F- Emergency Contacts Details and Procedures:


The following staff from both McLaren and Genfocus will be on site during the execution of the works and will be
responsible for managing the works;
Name Position Company Contact Details
Paul Carlin Operations Director Mclaren 056-1054691
Luke Watson Project manager McLaren 052-1022402
Prabhu Srinivasulu Construction Manager McLaren 050-9709963
Joby John HSE Manager (First Aider) Mclaren 050,6372060
Evangeline Huerto First Aider McLaren 056-1852727
Jijo Mathew Safety Advisor/First Aider McLaren 055-2152903
Ramil Magano OA/QC Engineer (Fire marshal) McLaren 050-2923058
Biju MEP Engineer McLaren 056-8059139
Syed Faisal Ahmed Project Manager Genfocus 056-5465814
Anu Baby Project Engineer Genfocus 0565465807
Prabir Kumar Chattarjee Safety Officer Genfocus 0547937312
Prabir Kumar Chattarjee First Alder Genfocus 0547937312

In case of an Emergency/fire Alarm, all operatives, Staff and Visitors are required to report to the Assembly
Point, which is indicated on the site logistics drawing, as indicated by the symbol below. Where the registers will
be checked to ensure that no one is un-accounted. No one will be allowed to leave the assembly point until the
Emergency response Controller confirms that it is safe to do so.

Assembly Point No·0l (TBA)

Assembly Point No·02 (TBA)

Please refer to the attached Crisis/Emergency Plan, (Appendix B) which is to be implemented where the need
arises.
) The Qualified First Aiders for the Project are listed below, and the first Aid Boxes will be available either in the
Induction/First Aid Room or in the Main Office.
Mclaren: (d1;tails of Fjrst Aiders} Subcontractors(Details of first Aiders l
Joby John- 050-6372060 Syed Faisal Ahmed 056·5465814
Jijo Mathew 055-2152903

Please see below the Emergency contact details

Method Statement Title llnstallatlon of Llsht Flttlnss Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �ycd Faisal fpproved By I Revision Date:
SAF•098 (UAE) 09/16 Rev G i of 19 RISK ASSESSMENT METHOD STATEMENT
r. GUL F
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS)
------
MCLAREN
I

Authority/Company Contact Telephone No.


Mclaren Construction Ltd 04-3417964
Police 999
Ambulance 997
GR Emergency No 058-2864950
AMC Emergency No 056-7459621

Section G- Mclaren Site Specific HSE Safety Induction:


Prior to any works taking place, all Operatives arriving at AMC project will be required to undergo a
Multiplex/Gulf Related safety induction followed by McLaren Site Safety induction, which will be held In the
induction room, by McLaren's HSE Representative or other designated person. Once the operatives have
received the site specific safety induction, they then will be briefed on the contents of this RAMS, by their
respective Site Supervisor, from which they will then be required a sign a RAMS Briefing Register (SAF019 UAE)
confirming that they have been briefed and that they fully understand the RAMS and what Is expected from
(_1 them during the execution of the site works. The Operatives will also be briefed on the Emergency and Security
Procedures for the project, which is also a part of site safety induction programme.
Any operative who will be operating any plant and equipment will be required to produce a copy of their
competenc y certificate/card carried out by an OSHAD approved third party training provider, to enable McLaren
to issue them with the Plant Operators Authorisation (SAF023 UAE).
Section H- Welfare facilities:
Drinking Water-
Clean drinking water will be provided on site (as per approved Logistics plan) and all operatives are to ensure
they take on enough fluids throughout the day.

Comply with Summer Working Requirements.


Rest areas and toilet-
Rest area and toilets are being provided at site and located as per AMC logistics layout plan

Section I- Personal Protective Equipment (PPE)


The Following Personal Protective Equipment must be worn/be available during the execution of the works
activities

Type of PPE Required Yes No


(_) Safety Helmet (as per standards) Yes
Safety Footwear (as per standards) Yes
Eye protection (as per standards) Yes
Gloves (as per standards) Yes
Hi- viz Vests Yes
Overalls (for operatives only) Yes
Ear protection Yes
Face Respirator No
Body Harness Yes
Respiratory masks Yes
Others (other specific requirements)
Please ensure that any specific precautions for PPE as Identified within MSDS/COSHH assessment or any
specific requirements bv sui,plier/manufacturer are to be compiled and adhered to.
M@thod Statement Title !Installation of Light Fittings Doc Ref No: K,EMC-ME-A-MST·00S
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: KJO
Prepared By �yed Faisal IJ\pproved By I Revision Date:
SAF•098 (UAE) 09/16 Rev G Sot 19 RISK ASSESSMENT METHOD STArEMENT
r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN,
I
I

Section J- Plant and Equipment to be Used


It is anticipated that the following hand tool will be used during the execution of the works; other items will also
be Identified on the schedule below;

• Various hand tools


• Tools (Drilling machines, hammer,etc)
• Grinders
• Rubber Padded Ladders

*Note: All relevant competency certificates (as per OHSAD /GR requirements) to be submitted to HSE
Manager/Eng./Advisor prior to start of any activity.
Below schedule to be completed by subcontractor)
Type of Plant/Equipment to be Used Yes No Type of Plant/Equipment to be Used Yes No
Lifting No Cradle No
Mechanical hoist No Excavation shoring No
Mobile elevating working platform No Hand tools Yes
Ladder Yes Electrical tools Yes
Hoist No CAT & Gen Set No
Test Equipment No Ventilation/Extraction Equip No
Task Lighting Yes Pump No
Tubular Scaffolding Yes lifting slings/chains No
Mobile scaffolds Yes Mechanical plant No
Podium Scaffold No Others:

Section K- Materials To be used.


The following Materials will be utilised during the execution of the works, the Material Data sheets being
provided, which will allow the relevant COSHH assessments to be carried out; (See Appendix C)
)
Item Material Description Has MSDS been Has the COSHH
provided and Assessment sheet been
attached? completed and attached?
1 Cable Tray/Trunking N/A N/A
2 GI/PVC Conduits N/A N/A
3 Wires and Armoured cables N/A N/A

Section LP Communication/Tool Box Talks/Training Requirements:


Once the RAMS has been briefed to the workforce, we will also hold Tool Box Talk relative to the work activities
being carried out, these will be conducted by the HSE team, in conjunction with the relevant site supervisors, this
will ensure that the message gets across to the workforce, in their own language, thus avoiding any
misinterpretation of the RAMS/Toolbox Talk.
Method Statement Title !Installation of Light Fittings Doc Ref No: G EMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal !Approved By I Revision Date:
SAF-098 (UAe) 09/16 Rev G 9 of 19 RIS� ASSESSMENT METHOD STATEMENT
r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN [
------

During the Preparation of this RAMS the following training for the staff and operatives has been Identified;
Item Description of Training Has the Training been If not, when will be
completed? (Yes/No) completed(Datel
1 3'0 party training for operative of plant and N/A
equipment
2 i<' party competency card for operators N/A
3 Rigg@rs, Banksman N/A
4 First aid training Yes
s Scaffolding Inspection and erection Yes
*Note: All relevant certificates will be submitted prior to works commencing or during induction. Where the
training has not been carried out, It must do so prior to the works/activities commencing.
()
Section M- Works Permits
The following works permits will be required during the execution of the Works;

Item Description of the Work Permit Permit Issued By Tick onlY applicable
1 Permit to Enter Confined Space McLaren
2 Permit for Lifting Operations. McLaren
3 Permit to Dig McLaren
4 Permit to work Hot cutting or Welding McLaren
5 Permit to Work In Celling Vold McLaren ./
6 Permit for Roof Access McLaren
7 Permit to Work with Ladders, steps McLaren ./
8 Permit to Work at Height McLarnn ./
9 Permit to Work - Electrical above 110V McLaren ./
10 Permit to Work with COSHH Items McLaren
11 Permit to Work at External Face ofThe Building McLaren
12 Permit for Removal of Existing Fall Protections McLaren
13 Permit for Existing MEP Service Isolation McLaren
Any other permits If required to be added

u Section N- Environmental and Waste Management:


During the execution of the project, waste will accumulate. Skips will be provided by McLaren and will be
required to put all waste in the skips provided. All waste will be segregated for recycling as per below sequence
1. Metal
2. Plastic
3. General waste
4. Concrete waste
5. Food waste
6. Hazardous waste
7. Wood Waste
Due to the nature of the works and the actual conditions of the present site, airborne dust will be minimal,
however where necessary the area affected by the installation of the temporary works, the dust will be
suppressed by spraying water.
Drip trays to be placed under plant and generator to catch any excess oil. A Jproved Waste Collection Contractor
Method Stat@mentTitle l!nstallation of Lisht Fittinss Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prnparnd By �yed Faisal jApproved By I Revision Date:

SAF•098 (UAE) 09/16 Rev G 10 of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN

will then remove excess oil from site in oil containers and sent back to store for collection.
Section 0- Programme for the Works.
The works will commence on 30/04/2019 For a duration of 4 weeks, as the works are scheduled, there will be
requirement for additional lighting in the working area.
However if Night shift starts, adequate task lighting will be required.
Section P- Housekeeping and Storage:
Housekeeping will be carried out as and when required and storage of materials will be in an agreed location (as
per approved site logistics plan) within the segregated area and as agreed in subcontractor prestart meeting. The
subcontractor will remove from site.
Section Q- Hygiene and cleanliness:
Hygiene and cleanliness are the upmost requirements for the project. Ali works carried out with AMC Projects
Procedures and requirements.

n Section R- Working at Height


During the preparation of the RAMS, the following activities for working at height have been identified and have
been addressed within the risk assessments within Appendix D.

Item Activity I Risk Assessment Reference I


1 Installation of Light fittings I Refer attached risk assessment I

Section S- Occupatlonal Health


During the preparation of the RAMS, the following Occupational Health Items have been reviewed and
addressed within this Method Statement.
·) Item Description of OH Item Preventative Measures, (see also within the Risk Assessments)
1 Manual handling As much as possible Eliminate the need for manual handling by
using mechanical aid
2 Falling from height Safety harness must be worn and hooked at secured place.
injuries/Fatalities Working at height training to be conducted by supervisor.
3 Cut and laceration Injuries Wearing loose cloths shall be avoided and wearing proper
-�
PPEs .

Method Statement Title llnstallatlon of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal jApproved By I Revision Date:

SAF-098 (UAE) 09/16 Rev G 11 of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN
-----�

Section T- Sequence of Works/Activities


The works will be carried out in the following sequences;
/I
l RAMS to be briefed to all the operatives involved in the work. ../ ./1
2 STARRT card to be prepared by assessing the area of work prior starting the work. /
/
3 Supervisor to ensure all operatives have received Mclaren and Multiplex site basic inductio� /
4 Supervisor to ensure all operatives have adequate PPE for the job Including Full �dy harness/'
5 Supervisor to ensure that the site is clean and ready to start the work. / /
6 Supervisor to ensure adequate tools are provided and advise Site manager if more t9ols are n�ed.
7 Works will be carried out in such a way as to minimize the Impact of the work.
I
I
INSTALLATION OF LIGHT FITTINGS:
All materials received at site store shal spected1 handled and stored upon receipt in accordance
1 '.711
with manufacturer's recommendation.
Site engineer shall ensure th,-411 materials received at site are as per the approved material
2
submittals.

3
The storage area will be clean and free f7 other materials to protect the light fittings against
damage.
Any damage or irregularity In the s7y noted on unpacking will inform to the concerned department
4
as a standard practice.
Site engineer shall check the area/location of installation of light fittings to ensure that all civil
5 activities and other works ch may affect or damage the light fittings after Installation are all
completed. /
1
6 Clean all terminal boxes and wires and make them ready for termination. /
7 Installation shall be carried out using approved shop drawings - latest. /
Suitable type of ladders/scaffolds shall be d at the time of installation depending on the location of
8 /
lights to be fixed.
For the lights to be instaUed in false c g, the locations shall be marked where holes are required and
9 ,
') holes are made using drywall saw.
Supervisors shall refer types of light fittings to be fixed in a particular area/location on the shop
10 ,
drawings. /
11 Fixing of light fittings above pipes, ducts, trays and trunking shall be avoided. / /'
12 Connection between light fittings and celling roses shall be made using heat resistant cable. 1
13 Ceiling roses locations shall be easily accessible. /
14 All light fixtures shall be connected with earthing cable.
I

Method Statement Title l1nstallation of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal jApproved By I Revision Date:

SAF-098 (UA�) 09/16 Rev G 12 of 19 RISK ASSESSMENT METHOD STATEMENT


r. C:.iULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN
-----�

APPENDIX A

Site Logistics Plan

-�

Method Statement Title l1nstallation of Light fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal jApproved By I Revision Date:

SAF-098 (UAE) 09/16 Rev G 13 or 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS} McLAREN
-- ---- - -

n APPENDIX B

CRISIS PLAN

Method Statement Title !Installation of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal jApproved By I Revision Date:

SAF-098 (UAE) 09/16 Rev G 14 of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN

CRISIS PLAN

1. Upon an incident, being discovered the first member of McLaren's staff or the site operative
discovering the incident shall inform the Project Manager and Site HSE team through AMC Project
emergency Contact No-056-7459621.

2. Both the HSE Engineer/advisor and the First Alder are to attend the scene with their mobile. The
project Manager or authorised person waits In office ready to contact relevant emergency
services.

3. Both the HSE Engineer/advisor and the first Aider are to assess th@ situation and put in place the

·.,
relevant systems to end/deal with the emergency.

4. Both the HSE Engineer/advisor and the first Aider are to ensure all trades are gathered at the
assembly point and liaise with supervisor to account for all operatives - no person should leave
site.

5. Either the HSE Engineer/advisor or the first Alder phones the project Manager or site receptionist
and informs him/her of which emergency services are required.

6. The Project Manager calls all relevant McLaren staff.

7. Both the HSE Engineer/advisor and the first Alder waits for the emergency services at scene.

8. Once emergency services arrive, The Project Manager will telephone the relevant authorities, i.e.
the HSE/Client's Safety Advisor/QHSE Manager/McLaren's operations Director.

9. Both the HSE Engineer/advisor and the first Alder keep trades Informed of the situation and
releases trades to return to work or leave site only when emergency services or The Project
Manager instruct that it is safe to do so, and all names of witnesses are recorded.

10. Project Manager or Construction Manager are to arrange for photographs of the scene to be
taken, and If necessary the area to be cordoned.
)
A full Investigation of the Incident is to be carried out, with a written report being submitted the
SHEQ Director, as soon as practicably possible after the incident, including all witness statements,
11. photos of the scene, Induction and method statement records, recommendation to prevent a re­
occurrence and what action has been taken since the incident taking place.

Method Statement Title !installation of Light Fittings Doc Ref No: �EMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: KJO
Prepared By �yed Faisal jApproved By I Revision Date:
SAF-098 (UAE) 09/16 Rev G 15 of 19 RISK ASS�SSMeNT MHHOO STATEMENT
r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN I

APPENDIX C

COSHH ASSESSMENTS AND MSDS

(Not Applicable)

Method Statement Title J1nstallation of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal fApproved By I Revision Date:

SAF-098 (UAE) 09/16 Rev G 16 of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS) McLAREN 1
� ����

APPENDIX- D

RISK ASSESSMENTS

Method Statement Title llnstallatlon of Light Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: 00
Prepared By �yed Faisal jApproved By I Revision Date:

SAF•098 (UAE) 09/16 Rev G 17 of 19 RISK ASSESSMENT METHOD STATEMENT


r. GULF
RELATED RISK ASSESSMENT METHOD STATEMENT (RAMS} McLAREN
-----�
I

') APPENDIX-E

TECHNICAL INFORMATION

Method Statement Title !installation of light Fittings Doc Ref No: K,EMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project Revision No: po
Prnpared By �yed Faisal jApproved By I Revision Date:

SAF•098 (UAE) 09/16 l\cv G 1s of 19 RISK ASSESSMENT METHOD STATEMENT


..
'-' _:J

r. GULF
RE.LATED RISK ASSESSMENT METHOD STATEMENT (RAMS) : McLAREN I
Md project/client logo

Method Statement Title �nstal!ation of Ligiht Fittings Doc Ref No: GEMC-ME-A-MST-005
Project Location: AMC Connectivity Corridors & Concourse Bridge Project 'Revision No: �o
Prepared By �yed Faisal !"-Pproved By l Revision Date:

SAF-098 [UAEI 09/16 Rev G 19oH9 RISK ASSESSMENT METHOD STATEMEITT


-· _j

Document Reference
AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005
- - Rev. No. Rev. Date
I
00 26/02/02019
McLAREN I Tide
Risk Assessment R.ecord Assessed by Sig,iature
Activity: Installation of Light Fittings Safety
OfT!C�
Prabir ,. .K .., .....,--

Base Risk Ranking Residual Rf5k Ranking

I I I �I
CONTROL MEASURES
IDEITTlFIED {','rrtflout Controls) {','rrtt, C.on.trols) Person
ACTIVITY People Involved
Risk Risk Risi: Risk Responsible
J
I
HAZARDS/RISKS
L s s
Score Rating L Score Rating

1) Delivery/ collect[on drivers shall be subject to


Mclaren induction/Training with regards to traffic
management.
2)Ensure exclusion zone is set up a round the
Plant and Traffic preparation work area and all plant movement
movement and checked by supervisor
3) Always use the pedestrian access provided
4) Traffic tight batons shall be p
· rovided for banks
• Hit by reversing man at night
equipment 5) All plant to have a fully trained banks man
Delivering.
unloacfirrig and
• Overhead present a.II times.
storing of Light obstructions 6) No plant to reverse without banks man.
Fittings accessories • Vehicle break OperatiYes 7) Ensure access route are .sufficient and safe to SiteEngJ
materials using down Staff/visitors Medi use. Su:pervisor
4
l
12
foreman.
3 3
pcd:up van and um
3 l
• Propertydamage 8) Do not take rest in or under vehides
unloading by • Collision with 9) Proper barricade and safety signboard
manual handling prnvided on, open elCicava ,tion
other vehicles
and shifting by
• Fragile materia Is 10) All vehides must be fitted with reverse alarm
using paJfet trolley.
• Personal injury / Flashing light.
Acaident due to 11) The work place and all access to re well
poor lighting and ii luminated.
visibi[ity (operation 12) Ensure Handfe with care Label must paste in
at night every fragile boxes.
13) Enforce Speed fimft
14) Ensure all vehides entering the site is
property maintained and reported if found any
defect
15) Ensure materials are secured/tied in pallet

SAF--010 [UAEJ Ol/18 Rev D SP£CIFIC RISKASS!5SMEM Rf:COE!D •iGIUiM


C _)

Document Reference

Rev. No. Rev. Date


AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005
��----

Asses-sed by Signature
00 26/02/02019
McLAREN
1 Risk Assessment Record
Safety
rrtfe

Officer·
Activity: lnstalfation of Light f7rt.tings Prabir J'>f ,,__.....-r-

Base Risk Ranlong Residual Risl. Ranking


CONTROL MEASURES
IDEN!TIAED (Without Control:s) (With Controls) P'erson
ACTIVITY Peopte Involved
HAZARDS/RISKS Rislc Risk Ris J Risk Responsible
s I Score ,1Rating
1 s ISeo :
l
I L I Rating

trol!ey to avoid fall from trolley.


16) Do not ride or horse play with pallettrolfey.

SAF-010 [UAE) O(l/]8 8"' D SPECIRIC RISK ASSSSMENT RECORD •&3511$$


\_, J

Dorument Reference

Rev. No. Rev. Oate


AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005

00
-------

Assess-eel bv I Title
26/02/02019
McLAREN
Ri,sk Assessment Record Sigr,,ature
Activity: Installation of Light fittings Prabir
Safety
I .....,.......,--
Officer

Base Rislc Ranling Residual Risi:. Ranking


ACTIVITY
rDENTIFIED
HAZARDS/RISKS
People tnvolve<:I

L I
s I 1
!Without Controls}

Score Ratirig
Risi: R,sl:
CONTROL MEASURES

L
I I �I
(With Controls)
s ScoreRisk
Rating
Ri:slc
Person
Responsible

l) Eliminate the need for manual handling by


using mechanical ai:d.
2IReduce the werght of a !load to limit force
exertion
31 If unsure of the load weight, check with
supervisor.
S)Ensure prop, er manual handring prooedure
musculoskeleta,I Supervi:sor,
61 rdentify and eliminate sharp edges before any
invotved in work
Manual Handling dfsorders, Hand Operatives Med Foreman ,
2 manual lift
injuries, cut , bruises 4 3 12 ium 7) Carefully handle the Firagile materials 1 3 3 Site Eng.
Sharp edges and
8) Ensure adherence with Slllfficient and
Fragile item.
appropriate PPE.
9) Limit load carrying to 20kg per person
10) Supervisor must make sure while manual
handling foa.d individual task and environment to
be considered to reduce the risk of manual
handling.

SAF-010 [UAEI03/1& Rew D SPECIFIC RISKASSESSMaIT RECCED i&Giihi


L .._/

Docoment Reference
AMC CONCOURSE BRtDGE PROJECT
Rev. Date
GEMC-ME
. -A-MST-005
---- -- Rev. No.
26/02/02019
Signature
00
McLAREN
Risk Assessment Record Assessed by Trtle
1Prabir Safety
Offi<ler
Activity: Installation of Light F-.ttings I '"' r'l..«"'-r-

Base Risk Ranking Residual Risk Ranking


CONTROL MEASURES
ACTIVITY
IDENTIFIED
HA2ARDS/RJSKS
People Involved
l
I I
(W"rthoot Controls)
s Risk I Risk
Score, Rating
L I I �I
(With Controls)
5 Risk Risk
_
Score Rating
Person
Res?(lnsible

l}Ensure· accesses. are keipt clear at a[I ti:mes.


2)Housekeeping to be carried out reg]Jlarty
throughout the day when required
3}Su:pervis.or to ensure operatives are stacking

I Material storing I
Slips, Trips and fall
Poor house f<eep.ing
Operatives
I Staff/storekeeper l
I I I .
materia I neatly and stacks are stable and in a safe
condition
4 Provide adequate righting especially during
Med 1 �
mghthours
II s,pe<viro,,
Foreman,
Site Eng.
3 3 12 4 4
4 ium S} Appropriate space is allowed around storage 1
areas for emplo,� to move a round safely
witfiout the risk being trapped between stacked
materials.
6} Storing Fragile Mate:rials with Handf.e with care
label in boxes.

l} Only tratne<l and authorised �rsonnelto carry out


thetask.
I I I I I I 2} Ensure the PTW fn place.
Work at height
3) Ensure proper working platform wittl complete fall
Fall form height protection
4) Ensure full body hames.s. and 100% Tie of
4 I
Installation of Operatives/Staff/
f

Falling objects S) En.sure the scaffold platform ;:s properly erected S\Jpervis.ors
Light Fittings Visitors
High with "Safe to use" tilg. • Foreman,
using Mobile Others. 16
4 4 4
Over loading and 6) Ensure ,ca,stor wheer& are locked and out rigger in 1 4 Site Eng.
scaffold place.
collapse
I 1 1
7} Hand toor.s must be sewred/tetnerecl
Uneven Floor
8) Do not allow over reaching and leaning from
Access & egress scaffolding J)latfonn.
9) Ensure safe wori:ing load of scaffold'ing as

SAF-010 (UA(l 03/18 lie', 0 SProRIC RISK =.ssMEm m:ORo •Ffi@•


'- _I

Document Reference
GEMC-ME-A-MST-005
Rev.No. Rev.Date
AMC CONCOURSE BRIDGE PROJECT
00 26/02/02019
----�--

McLAREN Assessed by Title


Safety
Risk Assessment Record
Activity:
5-gnature

Officer
Installation of Light fittings Prabir l' ,1..._"-,--

Base Rist Ranlong Residual Risk .Ra"nking


CONTROL MEASURES
ACTIVITY
rDENTIFIED
HAZARDS/RISKS
People rnvolved
L I I I
!Without ContJols}
s Scare Rating
Rist R,st
L
(With Controls)

l 5
IPJ
s �I
Ri�
k Rating
Score
Person
Respon.sible

mentioned in Green Tag.


10} Never leave loose materials on the platform.
11} Must clean the wor area after oomp.letion the jo.b.
12}Ensure safe access tok the worlcfng pbtform
B}Scaffold access must be � from obt,truction
14} Maintain 3 point contact while climbing on
platform.
15} Ensure that Scaffoldir.g fixed in a, plane· su.rfa:c:e.
1) Only right work, off short duration and wOTk in
which the operative· can maintai, n secure hand
and foot hofd can be undertaken form a ladder
2) Never try to· overreach with any ladders
3) Check the ladder is of suitable quality for
industrial use and is in good condition
4) Maintain a minimum ·Of 3 points of contact
with stepladders at all times (feet/thighs/hands)
Falling from height
If possibfe avoid the use of stepladders at a
6 Use oflad,de,r for working height of 2 meters and more. Supervisor
Operatives/ Med
Connection and Working on Uneven Site Eng.
Staff/ 4 3 5) Check. the ladder legs (and stays) are fully 3
Termrnation work ground ium deployed or locked (depending on type) to Foreman,
12 1 3

maintain maximum base dimen, sions and the ste.p


ladder is orientated to provide maximum stability.
Falling objects

6} Stepladders/ladders has to be used on leveted


ground/firm base
7} Ensure· that during using I.adder from the top 2
step is blocked to avoid dimb on that.
8} The ladder secure,ly fixed to prevent slipping
outwards or sideways or securely footed at all
times.

SAF-010 4UAE) 03/lS Rev D SPE.aRC 11B: ASScSSMEfff RECORD •EH@•


(_ ,J

Document Reference
AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005
- � Rev. No. Rev. Date
00 26/02/02019
McLAREN Assessed by Title Signature
Risk Assessment Recoro
Activity: Installation of Li!1it Fittings Prabir
Safety ...._""I.-
{'K :"'1... -..
Offker

Base Risk Ranking Residual Risk Ranking

I I I
CONTRotMEASURES

I I
IDENTIFIED [Wldiout Controls) {Wrth Conb'dls} Person
ACTIVITY People lnvo.lved
HAZARDS/RISKS Ris\ Risk Rislc ii Risk Responsjble
s. $()ore Rating s
Score Rating
L L

9) Person must hold the ladder while another


operative working on it
8) Materials sJ,ould not be placed above the
thread of ladders/step ladders
9) Do not carry any materials in one hand while
dimbing or getting down fTorn radder
10) Emure the area 1.mder the fadder is
barricaded espedally if it is being used in a public
area.
11) Ensure the la:dder is electrical insulated podfu
m type if working in live services

1. Prepare the working area for a good working


condition_
2.A!II workers should wear hi'gh vistbility vest and PPE

I I I I I
Physical injuries,
3.. Ensure that the working area is well-ventilated. Site Engg
Working [n poor Slips, trips & falls,
All personnel in Medi 4. Wear goggles & face masic when wcrling in a dusty
I
I visibility/dust Health effects -eye Supervisors,
the work area um place
7 3 4 12 1 4 4
coooition damag.e/respiratory Foreman
S. TBT conducted by supervisor.
diseases.
6.Firstaide..-and first atd kit available on the site
7) 'Ensure that worll: area m.ust. have !)roper Mrumination
8) Maintain good house keeping
Damaged cable 1) All portable electrical equipment must be PAT
irisulation, tested and color coded. Make sure the test dates
Use of power Sockets. are visible on the equipment. Supeivisor
Operatives
9 I tools such as. , Electrocution I I 3 I 4 I 12 I Med 2)Ensure all power tools 110 volt a,nd maintafned 1 4 4 Foreman
Drill machine·, Electric shock and staff 3) PTW to be obtained, prror to commencing the Site eng.
Short cirwit task
Trip/Fall 4) Damaged industrial sockets and power cabl'es

SAF-010 (UAflOl/18 lie, D SPECIFIC RISK AS'SESSMENT RfCOQD ilG&diHS


(_ J

Doalment Reference
AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005
--- -
Rev.No. Rev. Date
00 26/02/02019
McLAREN
Risk Assessment Record Assessed by Title Signature
Activity: Installation of Light ifittings Safety
Officer
Prabir � '"'l..c.�r-

Base Rksk Ran'king Residual Rislc Ranking

I I I
CONITROL MEASURES
IDENTIFIED !Without Controls} (With Controls) Person

I J
ACTIVITY P-eople Involved
Risl Risl !usk R,slc Responsible
s lScore
HAZARDS/R5KS.
Scare, Rating
s L
Rating
L

Noise must be remov,ed.


Hearing loss 5) Enstire the electrical cabfe is not damaged and
Vibration has not been repaired with insulating tape or
Dust
unsuitable connectors.
6) Ensure cables from power tools shall be
organized so as not to present a tripping hazard
7) Only trained competent operatives to operate
the :power tools.
8) Ensure proper and regular maintenance of
equipment that takes account of noise
9) Ensure proper hearing protection always.
10) Make sure people use the, right tool for the
job and are trained to use it correctly
11} Ensure defective tools that require
maintena,nce is report
: ed for repair or
replaceme11t.
12) Instruct workers to keep their hands warm
and dry, and to not grip a vibrating tool too
tightly,. Workers should allow the tool or machine
to do the work.
13) Ensuring proper job rotatcon and limiting
time operatives working with power tools and
hand tools.
14) use dust mask
Improper sefection 1) Hand too� should be visually inspected for Site Eng.

I
Use of Hand tools of hand tools, Operatives/Staf Med defects, prior to, use. Supervisor
10
and testing kit 3 3 9 1 3 3
Damaged and f ium 2) Never use damaged, blunt or broken toors to Foreman
Defective Hand avoid injury.

SP.F-01!0 (UAEI 03/18 Rev D SPECIFIC RISK ASSESSMENT RECORD 13&1411


"-" J

Document Reference
AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005
Rev.No. Rev. Date

McLAR���I Risk Assessment Record Assessed by


00
Title
26/02/02019
Signature
Activity: Installation of light fittings Prabfr
Safety
Officer
""').. .........�-

l
I I I IRis\l
Base Ristc: Ranking Residual Risk Ranking
CONTROL MEASURES I
IDENTIFIED (Without Controls} (With Controls) Person
ACTIVITY People rnvolved

I
HAZARDS/RISKS Risl: Risi: Risk Responsible
s L s Score Rating
l Score1 Rating

tools 31 Select right tools for righUob


Hand injuries 4) Ensure no Homemade or makeshift tools to be
Pinch point uised at site
Ergonomics 5) Remove from service any tool that shows signs
Repetitive strain of damage or defect
injury 6) Ensure Hand tools are Stored in accordance
with the manufacturer's instructions.
7) Ensure hands are not in direct line offire while
working with hancl tools.
8) Ensure all the testing kits are calibrated from
authorized lab.
9) Ensure appropriate PPE always.
fl Provision for av, ailability of drinking water at
work location.
21 Take rest in frequent interv ; als
3 Arrangement of weHare facility with First Aid.
4.1 Sufficient shaded rest area with adequate
Adverse weather ventilation avai'lable at work locatron Site engg
condition 5) Heat stress awareness training conducted. Supervisor
Heat stress Operatives/
6) aose monitoring of work force Foreman
11 External Work
Personnel ill,heath
Staff 4 4 16 7) Arrangement of Hydrolyte Powder for effective
1 4 4
Personal Injury rehydration solution
8) Ensure adequate Pf>E's
9) In case of High wind Externa'I work will have to
suspend unti I weather is under control.

SAF-010 [lJA� 03/18 � D SPt:CIRIC RISK =ssMENT RECORD •@HISS


L .._.J

Document Reference
AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-0O5
-
Rev.No. Rev.Date
00 2!6/02/02019
McLAREN Assessed by ntle Signature
Risk Assessment Record
Safety
Activity: Installation of Light Fittings Prabir
Officer f°"' ".")..-c. ....-r-

Base Risk Ranking Residua'! Risk Ranking

I I I
CONTROL MEASURES
IDENTIFIED (Without Controls) (Wlllh Contrnls} Person
ACTIVTTY
HAZARDS/RISI<$
People Involved
Risk Risk Risk ii
Risk Responsible
L S Score Rating
L ] 5
I
Score Rating

1) Ensure proper PTW is in place and correct


isolatJion procedure have been carried out (i.e.
LOTO}
Unauthorized 2) Ensure STARRT card is duly filled by responsible
Person person
Contact: with live 3) Ensure Proper RAMS briefing with sign off
services sheet signed by al I involved personnel.
Working near I Inadvertent release 4) Un-Authorized Persons Visible Warning Signs
live services of energy Operatives/Staff/ Must be in p,ace in the work area.
Electrical Hazard all surrounding S) All tools and eq,uipment property pre- Supervisors,

I I I
personnel
12 I I Electrocution working with in 4 5 20 inspect:ed and cofou r coded 1 5 5 • Foreman,
Electric Burn the area 6) Po,st Waming Si� & Caution Tags in the Site Eng.
Short circuit Concern Area.
Fire 7) Visual Inspection Of Cables If Any Damage
Lack of harricade 8) Maintain good housekeeping
and warning signs 9) Ensure proper 'Firefighting equipment rs in
Trip/Fall place and easily accessible.
10) Ensure sufficient and appropriate PPE at all
times
11) Ensure all operatives hands dry and do not
use· wet hand.

I
1) Ensure proper night work permit is obtained
Poor visibirity due to 'I '"""'' ljghtiog system <ho"1dbe io =,k
SiteEn-g.

I I I
Working at night darkness/ poor Place and access must be free from obstructron. • SupervisN
I Operatives/
13 I time illumination 4 4 16 3) Industrial: safe tordhes to be available fo:r 1 4 4 Forema'n
staff
Lone worke,- emergency situations
4) Employees tobe trained and understand
Mclaren Crrses plan,

SP.f-010 (UAEI 03/18 � D SPECIFIC RISK ASSESSMENT RECORD iiGIPii


'- --
Document Reference

Rev.No. Rev.Date
AMC CONCOURSE BRIDGE PROJECT GEMC-ME-A-MST-005

00
---�- -

Assessed by I Title Signature


McLAREN I
26/02/02019

Safety
RiiSk Assessment Record
Prabir
Officer
Activity: rnstallation of Light Fittings
,�J( ...� ....-r--

Bas:e Risk Ranking . .


Residual Risi< Ran�ing
(Without Controls} CONTROL MEASURES
rDENTIFIED (With Controls) Person
ACTIVITY
HAZARDS/RISKS
f>eople rnvolved
L
I I.I_
s Risi< Risk
Score Rating
L
I
5 1- .
Risk: I Risk
SGorel Rating
Responsible

3) Don't allow !one work.er


4) S(Jpervisor must monitor the work area.

-
Approved By: Name PRA:BIR KUMAR Position HSE Signature I ,�)<.. 0--"'-T

SAF-010 4l1Afl 03/18 Rev D SPECIRC RU ASSESSMEN'i RECORD iiiiM&I


MCLAREN

RISK ASSESSMENT & CONTROL GUIDELINES

1. Executing Steps:
1.1. Plannlns
a) Construction and HSE team must ensure that hazard Identification Is complete.
b) Construction and HSE team must prioritize the hazard issues, which are of significant In nature. (It moans that risks have well
established legal requirements, potentially high risks).
c) Construction and HSE team to prepare the risk assessment plan for the priorities identified hazards for these potential high
risks.
1.2. Risk As$essment
Risk is the probability of an event occurring in a given set of circumstances. The 'event' is an el<posure to hazard. The hazard Is the
potential to cause harm. The risk assessment Is the technique of evaluating not Just the likelihood of an event occurring, but also the
outcome will be In terms of Injury, loss, damage or harm.
1.3. Risk Assessment Process
The process of carrying out a risk assessment should be as follows.
1. Identify the hazards.
2. Identify who might be harmed and how.
3. Evaluate the risk and implement the control measures.
4. Record the significant findings.
5. Review the .isses$ment and update if necessary.
1.4. EKamlnatlon of the Hazards and Risk Associated
)> Competent staff must be used In examining the risk associated with the Identified hazard.
i;. Competent staff should examine following aspect to determine the risk Involved:
o Examine the existing control measures In place.
o Identify employees at risk.
o Likelihood of risk.
o Severity
o Risk level and their tolerability.
1.5. Evaluating the risk:
Once the necessary information has been obtained on the hazards encountered by work activities, next stage is to access the risks.
1.5.1. Risk Rating Score
Risk rating score is ;i combin;ition of two factor$.
)> The $everlty of the risk that could Injure persons or cause damage to plant.
)> The likelihood of the risk that It could happen (Probability),

RISK RATING = LIKELIHOOD X SEVERITY


NOTE: Each activity has to be assessed for the risk value for determining the level of Severity and likelihood are mentioned In the table
below.
J SEVERITY

LIKELIHOOD

RISK LEVEL;

Medium

SAF-010 (UAEI 03/18 Rev C SP£CIFIC RISK ASSESSMENT RECORD -