R K TECHNOLOGY LAB (A NABL Scope Laboratory For Calibration)

Add:. 109/9A Saket Nagar Habibganj


Bhopal – 462024
Tel:. 0755-4266841 Mobile:.+919926609307
Email:. rktechlab@gmail.com

CALIBRATION CERTIFICATE

Certificate no. RKTL/911/05/2019 Sheet 1 of 1


Date of receipt : 08.11.2019 Calibration on : 10.11.2019
Recommended date
Service request no : RKTL/450/2019 for next calibration : 10.11.2020
Calibration for : M/s K C Enterprises Type of equipment : Vernier caliper
61 -A, Sector-F, Industrial Area,
Govindpura, Bhopal

01. Identification on UUC* (Unit under calibration):


a) Manufactured by : Kristeel d) Range : 0 to 150 mm
b) Type : Stainiess Hardened e) Resolution : 0.02mm
c) Serial no. : Not mentioned f) Calibrated range : 1.00 to 130.00 mm
d) Identificatio no. : KC-VC-02 g) Declared accuracy : Not declared

02. Standard & major equipment (s):


Standard (s) & Uncertainty of Tracebility
Range
equipments measurement Cert. No.
Slip Gauges 0.5 mm to 0 to 10 mm : ± 0.20 µm BCL/SG/84401
(Mitutoyo) S. No. 979954 100 mm 50 to 100 mm : ±0.40 µm
with Accessories
T H E S T A N D A R D S U S E D A R E T R A C E A B L E TO N A T I O N A L S T A N D A R D S
03. Calibration results:

Standard
UUC*
Sl. No. Unit value value Correction
(average)

a. mm 1.00 1.000 0.000


b. mm 2.02 2.020 0.000
c. mm 10.24 10.240 0.000
d. mm 21.46 21.460 0.000
e. mm 51.68 51.680 0.000
f. mm 101.80 101.801 0.001
g. mm 120.00 120.001 0.001
h. mm 130.00 130.001 0.001
Parallelism of external measuring faces : 5 µm
The values have been rounded off as per IS:2-1960 wherever applicable.

Environmental condition (s) : Temperature (20±1)°C : Relative humidity (50±5%)RH


04. Remarks:
a) The correction is postive except when indicated otherwise. It has to be algebraically added to the UUC* value in
order to get standard value.
b) Expanded uncertainty of measurement (Stated above), corresponds to a confidence level of 95.45% taking coverage
factor k = 2.00
c) Calibration procedure RKTL/WI/10
d) Referto IS : 3651 (Part - II) - 1985 for specified accuracy.
Calibrated by Authorisation
LAB
ation)
ibganj
462024
609307
ail.com

Validity

11.02.2020

Expanded
uncertainty

±0.002 mm
on
R K TECHNOLOGY LAB ( A NABL Scope Laboratory for Calibration)
Add:. 109/9A Saket Nagar Habibganj
Bhopal – 462024
Tel:. 0755-4266841 Mobile:.+919926609307
Email:. rktechlab@gmail.com

CALIBRATION CERTIFICATE
Certificate no. RKTL/581/05/2016 Sheet 1 of 1
Date of receipt : 15.10.2016 Calibration on : 25.10.2016
Recommended date
Service request no : RKTL/118/2016 for next calibration : 25.10.2016
Calibration for : M/s K C Enterprises Type of equipment : Micrometer (Out Side)
61 -A, Sector-F, Industrial Area,
Govindpura, Bhopal

01. Identification on UUC* (Unit under calibration):


a) Manufactured by : Mitutoyo d) Range : 0 to 25 mm
b) Type : External e)Resolution : 0.01mm
c) Serial no. : 76250715 f) Calibrated range : 1.00 to 25.00 mm
d) Identificatio no. : KC-MM-01 g) Declared accuracy : Not declared

02. Standard & major equipment (s):


Standard (s) & Uncertainty of Tracebility
Range Validity
equipments measurement Cert. No.
Slip Gauges 0.5 mm to 0 to 10 mm : ± 0.20 µm BCL/SG/84401 11.02.2017
(Mitutoyo) S. No. 979954 100 mm 50 to 100 mm : ±0.40 µm
with Accessories
T H E S T A N D A R D S U S E D A R E T R A C E A B L E TO N A T I O N A L S T A N D A R D S
03. Calibration results:

Standard
UUC* Expanded
Sl. No. Unit value value Correction uncertainty
(average)

a. mm 1.00 1.000 0.000


b. mm 2.50 2.500 0.000
c. mm 5.10 5.100 0.000
d. mm 7.70 7.701 -0.001
e. mm 10.30 10.301 -0.001
f. mm 12.90 12.901 -0.001 ±0.010 mm
g. mm 15.00 15.001 -0.001
h. mm 17.60 17.601 -0.001
i mm 20.70 20.699 0.001
j mm 22.80 22.799 0.001
k mm 25.00 24.999 0.001
Flatness of measuring faces should be flat
The values have been rounded off as per IS:2-1960 wherever applicable.

Environmental condition (s) : Temperature (20±1)°C : Relative humidity : (50±5%)RH

04. Remarks:
a) The correction is postive except when indicated otherwise. It has to be algebraically added to the
UUC* value inuncertainty
order to getofstandard value.(Stated above), corresponds to a confidence level of 95.45%
b) Expanded measurement
taking coverage factor k = 2.00
c) Calibration procedure RKTL/WI/15
d) Referto IS : 2967 for specified accuracy.

Calibrated by Authorisation
B
R K TECHNOLOGY LAB (We Comitted To Serve You Better)
Add:. 109/9A Saket Nagar Habibganj
Bhopal – 462024
Tel:. 0755-4266841 Mobile:.+919926609307
INVOICE Email:. rktechlab@gmail.com

Pan No :- ARIPM8789R Date : 14/12/2019

Bill No:.1108/2019
: M/s K C Enterprises Your W.O. No.
61 -A, Sector-F, Industrial Area, Date
Govindpura, Bhopal Challan No
Date

NO. Description QTY RATE AMOUNT


1 Vernier Calliper 0- 150mm 1 250 250
2 Measuring Tape 3mtr 1 450 450

Sub Total 700.0


Visiting charge 0.0
)In Words : Seven Hundred
Less Advance 0.0
Rupees Only.
Net Amount Due 700.0

E & O.E.
1 Requested to pay amount cash or Demand Draft/Cheque in favor of
RK Technology Lab at Bhopal only. For
2 Interst @ 24% will be charged on overdue bills. R.K. Technology Lab
3 We reserve the rights to recover any tax. Duty or other levy application
to this transaction rights under Government enactment from you, if not
charged in this bill. Authorized Signatory
R K TECHNOLOG (A NABL Scope Laboratory for
Add:. 109/9A Saket Naga
Bho
Tel:. 0755-4266841 Mobile:.+91
Email:. rktechlab

CALIBRATION CERTIFICATE

Certificate no. RKTL/911/05/2019 Sheet 1 of 1


Date of receipt : 08.11.2019 Calibration on : 10.11.2019
Recommended date
Service request no : RKTL/450/2019 for next calibration : 10.11.2020
Calibration for : M/s K C Enterprises Type of equipment : Measuring Ta
61 -A, Sector-F, Industrial Area,
Govindpura, Bhopal

01. Identification on UUC* (Unit under calibration):


a) Manufactured by : Scot d) Range : 0 to 3 mtr.

b) Model no. : Not Mentioned e) Resolution : 1 mm

c) Serial no. : Not Mentioned f) Calibrated range : 1 to 3000mm.

d) Identificatio no. : KCE/MT/01 g) Declared accuracy : Not declared

02. Standard & major equipment (s):


Standard (s) & Uncertainty of Tracebility
Range
equipments measurement Cert. No.
Steel Scale 0 to 1000mm ± 0.24 mm BCL/SG/4406
with Accessories

T H E S T A N D A R D S U S E D A R E T R A C E A B L E TO N A T I O N A L S T A N D A R D S
03. Calibration results:
UUC* Standard value
Sl. No. Unit Correction
value (average)

a. mm 0 - 1000 1000.01 0.01

b. mm 1000 - 2000 1000.02 0.02

c. mm 2000 - 3000 1000.02 0.02

The values have been rounded off as per IS:2-1960 wherever applicable.

Environmental condition (s) : Temperature (20±1)°C Relative humidity: (50±5%)RH

04. Remarks:
a) The correction is postive except when indicated otherwise. It has to be algebraically added to the UUC* value in order to get
standard value.
b) Expanded uncertainty of measurement (Stated above), corresponds to a confidence level of 95.45% taking coverage factor k =
2.00
c) Calibration procedure RKTL/WI/24
d) Refer to report before use.
Calibrated by Authorisation
GY LAB
y for Calibration)
Nagar Habibganj
Bhopal – 462024
:.+919926609307
hlab@gmail.com

0
ng Tape

mm.

red

Validity

11.02.2020

RDS

Expanded
uncertainty

±0.010 mm

%)RH