Sei sulla pagina 1di 1

Reda Pump Performance Curve

REDA Production Systems S6000N The formula for (Low Discharge Pressure) is incorrect, it
538 Series * - 113 Stage(s) - 2917 RPM - 50 Hz state:
should
Rev. Fluid Specific Gravity 0.88
(Pump Head + Pump Intake @ maximum rate of
psi B.E.P."ROR")Hp Eff
Recommended Operating Range
Q = 5016
For Example: H = 1559.42
3,500 P = 182.30 700 70%
Normal intake pressureE==1200 PSI
72.99
Pump output pressure at maximum ROR = ~1000 PSI
3,000 600 60%
The starting value that should be = 2200 PSI
Having the Low Discharge Pressure alarm set to this value
would keep the pump out of the up-thrust condition
2,500 500 50%
Running at lower flows would increase pressure on the
system avoiding any trips unless the intake pressure on
2,000 the well came down overall 400 40%

1,500 300 30%

1,000 200 20%

500 100 10%

0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000


Capacity - Barrels per Day