METAL-CLAD SWITCHGEAR

TYPE ZS1

ABB EJF, a.s.


A A

B D 7 B D 7

1 1

3 3
2
2

5 4 5 4

6 C 6 C

ZS1 switchgear panel for 12 kV, 25 kA ZS1 switchgear panel for 25 kV, 25 kA

2
ZS1
Metal-clad air-insulated
medium voltage switchgear

with draw-out vacuum circuit-breakers


12 kV, ... 4000 A, ....50 kA
17.5 kV, ... 4000 A, ....40 kA
25 kV, ... 2500 A, ....25 kA

ZS1 The switchgear system for vacuum circuit-breakers

ZS1 The switchgear system with built-in safety

P as it is completely metalclad and partitioned.


P as the low voltage section is completely separated from the
high voltage sections.
P as quick-make earthing switches are used for earthing and
short-circuiting.
P as the operation of all equipment, including off-circuit and
inphase current checks, is carried out with closed front panel
door.
P as simple but effective interlocking prevents operator errors.
P as the cable terminal connections are easily visible through the
front panel door.
P as the panels are type-tested to DIN VDE 0670 Part 6
and IEC 60298.
P as tested according to DIN VDE 0670, part 601 (Pehla
quideline No. 4) and IEC 60298 Appendix AA.

ZS1 The switchgear system with built-in high availability


P as the tightly sealed enclosure protects the equipment from
ingress of contamination and vermin.
P as the vacuum circuit-breaker is maintenance-free.
P as an exchange of the circuit-breaker is very simple.
A Busbar compartment P as the test and auxility wiring fits into liberally dimensioned
B Circuit-breaker ducts and is easily accessible.
compartment P as plenty of space is available, allowing easy and fast cable
C Cable termination
connection.
compartment
D Low voltage
compartment
ZS1 The switchgear system with built-in flexibility
1 Busbar P as it fitted with standard measuring transformers as well as
2 Tulip contact sensor.
3 Circuit-breaker
4 Earthing switch P as all conventional types of cable terminations can be used.
5 Current transformer
P as up to six cables per phase can be fitted to the equipment.
6 Voltage transformer
7 Bay control and
protection unit REF542
ZS1 The application-orientated switchgear system.

3
ZS1: simple, robust construction

The factory-assembled, type tested The rigid enclosures of the


switchgear panels of type ZS1 for switchgear panels consist of steel
12 kV to 25 kV rated voltage are sheet with folded edges bolted
metalclad, air-insulated and together. Modern manufacturing
subdivided into part-compartments methods, e. g. the use of CNC
for busbars, machine tools, guarantee high
circuit-breaker, dimensional accuracy, thus
cable termination connections and facilitating final assembly at site. The
low voltage equipment. sheet steel used for the switchgear
The three high voltage compart- panels is aluminium galvanized. To
ments are fitted with separate ensure an attractive appearance, the
pressure relief facilities discharging in doors are coated with an
an upward direction. electrophoretic primer and then
stove enamelled. An allround impact-
ZS switchgear panels contain resistant surface and a good degree
withdrawable parts to accommodate of corrosion protection are thus
the relevant switching devices. achieved.

These can be fitted either with


vaccum circuit-breakers type VD4 ZS1: quickly installed
and VM1, or with vacuum contactors
up to 12 kV. The factory-assembled switchgear
panels are erected side-by-side at
The withdrawable part technology is site to form switchboards. A
retained in panels for bus beseframe laid in or on the floor is
sectionalisation using curcuit- recommended for speedier and
breakers and in metering panels. easier allignment. The new type of View into the busbar compartment
busbar system can be installed in a
The circuit-breaker unit can be very short time. Tubes with D-shaped
moved inside its compartment, crossections are fitted in sections It provides a direct connection to the
between the service position and the from panel to panel. This type of tee-offs without the use of terminal
test/isolation position, whilst the busbar combines high dynamic and clamps. Higher rated currents are
panel door remain closed. The unit is dielectric strengh with good heat conducted by two tubes with semi-
interlocked with the panel in both dissipation and a favourable ratio of circular cross-section in parallel. It is
positions. The auxiliary feed remains load carrying capacity to cross- also possible to provide partitions
connected in the test position via the sectional area. with bushings between adjacent
plug connections, so that the switch panels.
be tested mechanically.

Circuit-breaker compartment (door open),


breaker module in service position Breaker module in test/isolation position

4
The cable sealing ends can be
observed at any time through the
window in the door.

ZS1: safe operation and testing

It was always possible to operate


switchgear on site with closed panel
doors by one method or another. The
ZS-system offers more:
Without opening the door

P the draw-out unit is moved


into the service position or
into the test/isolation
position,
P the circuit-breaker is closed
and opened,
P the earthing switch is closed
and opened.
Cable
termination
compartment All these operations are mechanically
with threefold and eletrically, and all contact
cable
connection settings interlocked with each other
can be checked on mechanical
position indicators through
observation windows.
ZS1: spacious cable termination compartment. Since the horizontal All operations can naturally be
compartment partition between the cable carried out by motor operated
termination comparment and the mechanisms. The switchgear panel
The compact maintenance-free circuit-breaker compartment can be can, in that case, be operated
design of the busbar and circuit- removed very easily, as many as six entirely by remote control.
breaker compartments allows almost cables per phase can be connected,
50% of the switchgear panel volume depending on the panel type.
to be used as the cable termination

ZS1 circuit-breaker compartment after the breaker module has been Metalic shutters opened for checking of the contact pins in the
removed, fixed contact pins are covered by metal shutters and the circuit-breakers compartment
compartment is protected

5
The low voltage compartment is
encased separately from the high
voltage section. Since it varies in
height, there is sufficient space
available for all the required meters,
protective relays, push-buttons etc.

It is preferable to use the universal,


microprocessor-based bay control
and protection unit REF542 in place
of conventional secondary systems.
All the secondary systems functions
such as switching, controlling,
signalling, protection, measurement
and monitoring are performed by a
single device. As a result, the time
and work expended on project The bay control
planning, installation, commissioning and protection unit
REF542 in the front
and stocks are significantly reduced. door of the low voltage
All the functions of the REF542 are compartment
programmed specifically for the
application and subjected to
permanent self-monitoring. The bay the interlocks have been released. connections, are equipped with
control and protection unit REF542 is When the module reaches the capacitive voltage dividers, which are
in this case an integral part of the isolated position, steel shutters connected to sockets fitted to the
ZS1 switchgear system, and is type automatically cover the tulip contact panel door. The off-circuit condition
tested together with the panel. apertures, and so the circuit-breaker can be verified at any time with plug-
Trouble-free integration of the compartment is protected and in indicators appropriate to the
REF542 in a higher level automation partitioned off from the busbar and particular indication system.
system provides full remote control cable termination compartments.
capability for the ZS1 switchgear. A testing and earthing withdrawable
The steel stutters can also be module is available for currents and
A switchgear installation ZS1 with secured individually to prevent voltage tests. No timeconsuming
REF542 is known as an opening by unauthorized persons. All dismantling in the cable termination
Intelligent Switch Module (ISM), operations required in normal service compartment is necessary for cable
as a switchgear with brain. including off-circuit an in-phase DC or fault location testing as the
current checks are carried out with connecting bars between cable
For replacement purposes, the the panel door closed. The current connection terminal and transformer
circuit-breaker modules can easily be transformers or cast resin insulators can be deteached.
moved out onto a service truck after (whichever are fitted) on the cable

Withdrawable module with vaccum circuit-breaker VM1, 12 kV Withdrawable module with vacuum circuit-breaker VD4, 25 kV

6
TECHNICAL DATA
Rated voltage kV 7.2 12 17.5 25

Insulation VDE/IEC, List 2

Rated power-frequncy withstand voltage kV 20 28 38 50

Rated lightning impulse withstand voltage kV 60 75 95 125

Rated short-circuit breaking current kA .... 50 .... 50 ..... 40 ..... 25


of the circuit-breaker

Rated short time current 3s kA .... 50 .... 50 ..... 40 ..... 25

Rated peak withstand current kA .....125 ...125 ...100 .... 63

Rated current of the busbar A .... 4000 .... 4000 .... 4000 ...2500

1)2) 1)2) 1)2)


Rated current of the tee-offs A ...4000 ...4000 ...4000 ...20003)

4)
Protection class of the casing IP4X

Protection class with the circuit-breaker


compartment door open IP2X

Site altitude m m 1000

Ambient temperature:

Maximum °C + 40

Maximum 24-hour average °C + 35

Minimum °C - 5

DIMENSIONS

Height mm 2200 2200 2200 22005)

Depth mm 13007) 1300 7)


1300 7)
1500

Width:
Tee-off current up to 1250 A m 31.5 kA mm 650 650 650 800 6)

Tee-off current up to 1250 A > 31.5 kA mm 800 800 – –


Tee-off current above 1250 A mm 1000 1000 1000 1000

1) 4000 A/40 °C, with fan cooling


2) 3150 A/40 °C, with natur cooling
3) 2500A, with fan cooling
4) IP55 with reduced current ratings
5) 2325 mm optional
6) 1000 mm to special order
7) 1350 mm when foot-note 1) and 2) apply

7
A 357-292-I/1999

Data and ilustrations without engagement. We reserve the right


to make changes in the course of technical development.

ABB EJF, a.s. Tel.: +420 5 43152465, 43152482


Vídeňská 117 +420 5 43211256
658 67 Brno Fax: +420 5 43152451
Czech Republic +420 5 43152192