Building Component Catalogue with Level

of Development Specification (LOD)


Version 3.1 / September 2016
Foreword

The building component catalogue has been in use in many of internal use and for our partners. However, we would like
our building projects and also by external parties, e.g. to make it available to the industry. It may be used by
Københavns Ejendomme1. At the back of the catalogue a and be an inspiration to the construction industry as long
Model Progress Specification (MPS) is available. This describes as the source is scknowledged.
the needed information for each building element at a given
time in the project process. We welcome comments and suggestions for
improvements. The catalogue is continuously updated,
The motivation for this catalogue derives from the great while we use.
challenge in use of BIMs where it often is unclear what
Inquiries regarding this building component catalogue
information must be provided at a certain milestones. The
should be addressed to vdc@mth.dk.
catalogue has found inspiration in Level of Development
(LOD), developed by the American Institute of Architects Fully or partly reuse of this catalogue is only allowed after
(AIA). written approval from MT Højgaard. Contact MT Højgaard
vdc@mth.dk.
The building component catalogue will be integrated with a
Danish, Norwegian, American and English standard as soon as
it is available in a condition suitable for the implementation in
construction.

The purpose is:


• To assist project participants in our construction
projects to define the content to be included in a BIM
delivery, and to get a clear picture of the contents of a BIM
delivery.
• To help design managers and BIM coordinators in MT
Højgaard to communicate the information to be includede
in a BIM model at a given time.
• To provide a reference for contracts and project’s BIM
strategy.

The building component catalogue including a specification for


level of information, is targeted for MT Højgaard projects for

1
ICT-agreement – For projects with estimated value at or above DKK 20
million excl. VAT. Version 2.5, Københavns Ejendomme, 22-05-2014

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FOREWORD 2


Reading guide

This building component catalogue describes how MT Illustration: Displays the guiding geometry of the object
Højgaard defines the geometri (LOD, Level of Development) at a given level of information.
for the selected building parts and specifies suggestions for
properties (LOI, Level of Information) of the individual LOD: Describes the geometry in words.
building components. More properties can be added as needed
or building components can be the inspiration for another. LOI: Describes the properties that an object has at a
given LOD level. Properties of a building element at a
LOD is increasing, where LOD100 represents the lowest level given LOD level are the described characteristics including
and LOD500 represents the highest level. the properties from the previous LOD level. This means
that the previous properties are included automatically.
This building component catalogue is a reference book that
can be used together with the Model Progress Specification In general, definitions of systems describe where
(MPS) in relation to milestones (e.g. preliminary design, components are included such as drains on a sewer where
detailed design, as built). Firstly described are the properties the drains level of level is defined at an additional LOD
relevant to calculation, scheduling and energy calculations. building card.

This building component catalogue is primarily used in


construction, and civil works projects. This catalogue is also
published in Danish, Norwegian, German and Icelandic.

For each building component on the different levels of


development three aspects of a given building component is
described: illustration, LOD (geometry) and LOI (properties).

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - READING GUIDE 3


Table of Contents

Terrain .........................................................8  Staircase, steel ........................................... 46 


Levelling/gradings .........................................9  Utility ........................................................ 48 
Excavation for foundations ............................ 10  Pipe services, terrain ................................... 49 
Excavation for pipes ..................................... 11  Water-carrying installations (heating, drainage
Road and railway ......................................... 12  (rainwater/sewage), domestic water, cooling and
Road and railway equipment ......................... 13  sprinkling) ................................................. 50 
Dam .......................................................... 14  Air born installations.................................... 51 
Existing pipework ........................................ 15  Ventilation ................................................. 52 
Drainage .................................................... 16  Electricity................................................... 53 
Room ......................................................... 18  Low voltage (CTS & IT and data communication,
Roof .......................................................... 19  security, personal security access security) ..... 54 
Light Facade ............................................... 20  Sample of Model Progression Specification ...... 55 
Heavy Facade ............................................. 21 
Light Interior Walls ...................................... 22 
Floor .......................................................... 23 
Ceiling ....................................................... 24 
Elevator ..................................................... 25 
Door .......................................................... 26 
Window ...................................................... 27 
Foundation, concrete element ........................ 29 
Foundation, insitu ........................................ 30 
Slab – terrain, insitu .................................... 31 
Concrete slab, element ................................. 32 
Concrete slab, insitu .................................... 33 
Light slab, steel ........................................... 34 
Concrete Beam, element............................... 35 
Concrete Beam, insitu .................................. 36 
Concrete Wall, element ................................ 37 
Concrete Wall, insitu .................................... 38 
Concrete Column, element ............................ 39 
Concrete Column, insitu................................ 40 
Frame ........................................................ 41 
Steel Beam ................................................. 42 
Steel Column .............................................. 43 
Staircase, insitu........................................... 44 
Staircase, element ....................................... 45 

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - TABLE OF CONTENTS 4


Basic definition of Information Levels (Level of Development – LOD and LOI)

LOD 100 LOD 200 LOD 300


Corresponding to information level 1 according to Corresponding to information level 2 according to Corresponding to information level 3 according to
Københavns Ejendomme2. Københavns Ejendomme. Københavns Ejendomme.

Definition Definition Definition


Object (or structure) is graphically represented in the Object (or structure) is graphically represented as a Object (or structure) is graphically represented as a
model by symbols (e.g. by a line or surface) or generic object with approximate quantities, sizes, specific object representing quantities, sizes,
generic (i.e. dimensions and quantities are not dimensions, location and orientation. The function of dimensions, locationand orientation. Object’s overall
defined). This represents the overall geometric the objects are described. function, performance and material are described.
expression of the object and the relations to its At this point, the model will be divided into a number
surroundings. of discipline models.

Possible use Possible use Possible use


Overall energy considerations, price calculation on m2 Scheduling, safety planning, calculation based on Production scheduling, calculation based on geometric
or m3 (e.g. parking house for 300 cars), risk analysis areas (floors, facades, roofs, and functional areas), or function specific objects (m2 terrain slab, m2 facing
to determine the geometrical design and layout of product preparation, risk analysis, clash detection and wall, number of skylights, meter railing), list of parts
construction site including site huts, access roads and energy calculations. and clash detection.
crane location.
Liability Liability
Liability Typical architects and consulting engineers. Typical architects and consulting engineers.
Typical architect.

2
According to ICT-agreement – For projects with estimated value at or
above DKK 20 million excl. VAT. Version 2.54, Københavns Ejendomme,
22-05-2014

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE 5


Basic definition of Information Levels (Level of Development - LOD)

LOD 350 LOD 400 LOD 500


Corresponding to information level 4 according to Corresponding to information level 5 according to
Københavns Ejendomme Københavns Ejendomme

Definition Definition Definition


Object (or structure) is graphically represented as a Object (or structure) is graphically represented, Object’s (or structure’s) quantities, sizes, dimensions,
supplier-specific object with quantities, sizes, possibly as a supplier-specific object with quantities, location and orientation is confirmed on site (as built).
dimensions, location and orientation. sizes, dimensions, location and orientation.
Objects are detailed at connections with other building Objects are detailed for fabrication, assembly, Possible use
components. prefabrication, and contains also installation Post-calculation for confirmation, registration of
“Manufacturer/supplier” concerns information about information. deficiencies and part lists.
the suppliers products including, data sheet
specifications, color codes, warranty period, intervals Possible use Liability
for maintenance and inspection, lifespan, etc. Prefabrication, list of parts and the specific assembly Typical contractor, but can be by the responsible for
or installation planning. discipline model.
Possible use
Production scheduling, calculation based on Liability
production parts, components and production material Typical subcontractor or system supplier for
(m3 concrete, level of reinforcement, formwork, cast- prefabrication.
in items), list of parts, clash detection (coordination of
design and system deliveries).

Liability
Typical architects and consulting engineers.

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE 6


Infrastructure

Terrain 
Levelling/gradings 
Excavation for foundations 
Excavation for pipes 
Road and railway 
Road and railway equipment 
Dam 
Existing pipework 
Drainage 

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - INFRASTRUCTURE 7


Terrain

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD


Existing terrain is displayed as Existing terrain is displayed as Existing terrain is displayed as Existing terrain is displayed as
a 2D surface with a reference a 3D surface, based on manual a 3D surface created by a a 3D surface created by a
point (elevation) which is points measured by total network of measured points network of points measured
average for the area. station or rover. Points are from e.g. an overflight or laser e.g. an overflight or by laser
measured in height/depth and scan. scanning. Lower layers of soil
LOI for each 10/20 meters. such as clay, chalk, sand etc.
Type LOI are displayed as independent
Surface name LOI Type 3D surfaces with data from
Elevation Type Surface name measured drill samples.
Layer name Surface name Elevation
Elevation Layer name LOI
Layer name Classification Type
Classification Surface name
Elevation
Layer name
Classification

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - TERRAIN 8


Levelling/gradings

LOD 100 LOD200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD


2D levelling surface. Levelling with vertical Levelling with gradient to other Accurate levelling with gradient
connection to other surface. surface. to other surface.
LOI
Type LOI LOI LOI
Surface name Type Type Type
Elevation Surface name Surface name Surface name
Layer name Elevation Elevation Elevation
Layer name Layer name Layer name
Classification Classification Classification
Slope signature Slope signature

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LEVELLING/GRADINGS 9


Excavation for foundations

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD


Rough excavation as a surface Rough excavation as a surface Excavation for foundations as a Excavation for foundations with
to a fixed level. to a fixed level with connection 3D surface with vertical walls. sloped walls.
to existing terrain.
LOI LOI LOI
Type LOI Type Type
Surface name Type Surface name Surface name
Elevation Surface name Elevation Elevation
Layer name Elevation Layer name Layer name
Layer name Slope signature Slope signature
Slope signature Classification Classification
Classification

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - EXCAVATION FOR FOUNDATIONS 10


Excavation for pipes

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD


Rough excavation along line. Rough excavation along 3D Excavation for pipe with a 3D- Excavation for pipe with
object. plan excavating surface. excavating surface connected
LOI to other surface.
Type LOI LOI
Elevation Type Type LOI
Slope Elevation Elevation Type
Layer name Slope Slope Elevation
Layer name Layer name Slope
Classifiaction Classifiaction Layer name
Surface name Classification
Slope signature Surface name
Layer, name of surface, level. Slope signature
Corridor name

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - EXCAVATION FOR PIPES 11


Road and railway

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Centerline of road and/or 2D surface specifying road Top surface (3D) with Top and planum surfaces with Kerb stones, road structure
railway (2D). and/or railway layout. connection to terrain. gradients to terrain. with layouts, ditches with
slopes to terrain.
LOI LOI LOI LOI
Type Type Type Type LOI
Dimensions Dimensions Dimensions Dimensions Type
Layer name Layer name Layer name Layer name Dimensions
Elevation Elevation Elevation Layer name
Classification Classification Classification Elevation
Surface name Surface name Classification
Slope signature Slope signature Surface name
Slope signature
Corridor name

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ROAD AND RAILWAY 12


Road and railway equipment

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Specification of the location of Specification, as a volume, of 3D geometry of road- and 3D geometry of road- and Manufacturer specific details
road- and railway equipment. the location of road- and railway equipment. railway equipment with are modelled as joints.
railway equipment. invisible/hidden geometry such
LOI LOI as foundations. LOI
Type LOI Type Type
Layer name Type Layer name LOI Layer name
Layer name Classification Type Classification
Classification Layer name
Classification

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ROAD AND RAILWAY EQUIPMENT 13


Dam

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Centre line of dam. Location of where the dam is Top surface with connection to Dam structure including the Dam structure including the
placed. the existing terrain. layer structure. layer structure and equipment.
LOI –
Type LOI LOI LOI LOI
Dimensions Type Type Type Type
Stationing lines Dimensions Dimensions Dimensions Dimensions
Layer name Elevations Elevations Elevations Elevations
Stationing lines Stationing lines Stationing lines Stationing lines
Layer name Layer name Layer name Layer name
Classification Classification Classification Classification
Surface name Surface name Surface name
Corridor or grading name Corridor or grading name Corridor or grading name
Slope signature Slope signature Slope signature

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - DAM 14


Existing pipework

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Approximately location of pipes Approximately location of pipes Approximate location including Actual dimensions, location and Accurate geometry, including
as 2D lines. as 3D lines. slope and size of main design. Materials, capacity and thickness of materials and pipe
distribution route and service systems may be represented in lengths. Location of valves.
LOI LOI pipelines. the model. Materials, capacity and systems
Type Type must be represented in the
Dimensions Dimensions LOI LOI model.
Elevation Elevation Type Type
Slope Slope Dimensions Dimensions LOI
Layer name Layer name Elevation Elevation Type
Classification Slope Slope Dimensions
Layer name Layer name Elevation
Classification Classification Slope
Layer name
Classification

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - EXISTING PIPEWORK 15


Drainage

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Approximately location of pipes Approximate location and size Approximate location and size Actual dimensions, location and Accurate geometry, including
as lines. of main distribution routes and of main distribution route and design. thickness of materials and pipe
service pipelines. service pipelines with joints. lengths. Materials, capacity and
LOI LOI systems must be represented
Type LOI LOI Type in the Model.
Dimensions LType Type Dimensions
Layer name Dimensions Dimensions Layer name LOI
Layer name Layer name Classification Type
Classification Classification Elevation Dimensions
Elevation Elevation Slope Layer name
Slope Slope Classification
Elevation
Slope
Material
System name
Capacity

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - DRAINAGE 16


Architect

Room 
Roof 
Light Facade 
Heavy Facade 
Light Interior Walls 
Floor 
Ceiling 
Elevator 
Door 
Window 

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ARCHITECT 17


Room

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Physical room/space partitioning The rooms contain: Suspended ceilings including Suspended ceilings including Suspended ceilings including
by function. Glazed elements/windows tiles and floors are added with tiles and floors are added with tiles and floors are added with
Door openings (if relevant). Doors/hatches thickness. thickness. thickness.
Connections. Stairs
Landings LOI LOI LOI
LOI Fixed furniture/equipment Type Type Type
Type Sanitary Name Name Name
Name Suspended ceiling Function Function Function
Function Dimensions (approx.) Dimensions (approx.)
Dimensions (approx.)
Dimensions (approx.) LOI Classification Classification
Classification
Type Person capacity Person capacity
Person capacity
Name Room number Room number
Room number
Function Audio requirements Audio requirements
Dimensions (approx.) Insulation requirements Insulation requirements Audio requirements
Classification Fire requirements Fire requirements Insulation requirements
Person capacity Functional requirements Functional requirements Fire requirements
Room number Functional requirements
Audio requirements
Insulation requirements
Fire requirements
Functional requirements

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ROOM 18


Roof

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The roof's location is Size, exact shape and location. Building roof in layers (e.g. The roof contains, depending All assembly components and
represented either by the Approximate location, size and roofing, insulation and on the type, reinforcement. The details are modelled. It includes
external surface geometry and orientation of openings. concrete) with external different layers are modelled. internal supporting elements
shape or by a geometric dimensions. Opening dimensions and (as laths) or reinforcement
placeholder with an LOI Openings for windows, doors locations are accurate. details.
approximate geometry. Type and larger ducts are
Dimensions determined. LOI LOI
LOI Elevations Type Type
Type Classification LOI Dimensions Dimensions
Dimensions (approx.) Type Elevations Elevations
Dimensions Classification Classification
Elevations Material Material
Classification Structural system Structural system
Material U-value U-value
Structural system Weight Weight
U-value Surfaces Surfaces
Weight Manufacturer/supplier

MT HØJGAARD A/S -BUILDING COMPONENT CATALOGUE - ROOF 19


Light Facade

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The facade’s location is Size, exact shape and location. The structure of the roof is The roof contains, depending All assembly components and
represented either by the Approximate location of holes modelled in layers (eg. roofing on the type reinforcement. The details are modelled. It
external surface geometry and and openings. felt, insulation and concrete), different layers are modeled. includes laths and reglar or
shape or by a geometric external dimensions. Hole dimensions and location reinforcement details.
placeholder with an LOI Holes for windows, doors and are accurate.
approximate geometry. Type larger penetrations are LOI
Dimensions specified. LOI A Type
LOI Elevation Type Dimensions
Type Classification LOI Dimensions Elevation
Dimensions (approx.) Type Elevation Classification
Dimensions Classification Materia
Elevation Materia Structure
Classification Structure U-value
Materia U-value Weight
Structure Weight Surfaces
U-value Surfaces Manufacturere/supplier
Weight

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LIGHT FACADE 20


Heavy Facade

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The facade’s location is 3D geometry that describes the The wall is modelled with layers Buildable detailed construction All assembly components and
represented either by the approximate size, shape and at precise external dimensions. of the wall. details are modelled in 3D. It
external surface geometry (2D- location including size and Openings for windows, doors The different layers are includes studs, reglar and
plane) and shape or by a orientation of openings. and larger penetrations are modelled. fittings.
geometric placeholder with an determined. Openings’ dimensions and
approximate geometry. LOI locations are accurate. LOI
Type LOI Type
LOI Dimensions Type LOI Dimensions
Type Elevation Dimensions Type Elevation
Dimensions (approx.) Elevation Dimensions
Classification Classification
Insulation thickness Classification Elevation Insulation thickness
Bearing/non-bearing Insulation thickness Classification Bearing/non-bearing
Bearing/non-bearing Insulation thickness Material
Material Bearing/non-bearing Weight
Weight Material U-value
U-value Weight Surface
Surfaces U-value Manufacturer/supplier
Surface

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - HEAVY FACADE 21


Light Interior Walls

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Interior wall’s location is 3D geometry that describes the The structure of the wall is Buildable detailed construction of All assembly components and
represented either by a surface approximate dimensions, shape modelled with layers (e.g. the wall. details are modelled in 3D. This
geometry (2D-planes) and and location. insulation and gypsum boards) Walls contain, depending on the includes internal supporting
shape or by a geometric Approximate location, size and at precise dimensions. type, reinforcement. The elements as laths, rules and
placeholder with an orientation of openings and Openings for windows, doors different layers are modelled. such as gypsum board, or
approximate geometry. holes. and larger penetrations are Openings’ dimensions and reinforcement details and
exact and fixed. locations are accurate. connections.
LOI LOI
Type Type LOI LOI LOI
Dimensions (approx.) Dimensions Type Type Type
Elevations Dimensions Dimensions Dimensions
Classification Elevations Elevations Elevations
Bearing/non-bearing Classifications Classifications Classifications
Bearing/non-bearing Bearing/non-bearing Bearing/non-bearing
Material Material Material
U-value U-value U-value
Audio requirements Audio requirements Audio requirements
Weight Weight Weight
Fire (performance) Fire (performance) Fire (performance)
Sound (performance) Sound (performance) Sound (performance)
Insulation (performance) Insulation (performance) Insulation (performance)
Surfaces Surfaces
Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LIGHT INTERIOR WALLS 22


Floor

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The floor's location is Size, exact shape and location. The construction of floor in Buildable detailed structure of All assembly components and
represented either by the Approximate location, size and layers with precise external the floor. details are modelled in 3D.
surface geometry (2D-planes) orientation of openings and dimensions. The floor contains, depending This includes possibly internal
and form or through a holes. Openings for larger on the type, reinforcement. The supporting elements as joists.
geometric placeholder with an penetrations are fixed. different layers are modelled.
approximate geometry. LOI Openings’ dimensions and LOI
Type LOI locations are accurate. Type
LOI Dimensions Type Dimensions
Type Elevation Dimensions LOI Elevation
Dimensions (approx.) Elevation Type
Classification Classification
Classification Dimensions U-value
U-value Elevation Fire (performance)
Fire (performance) Classification Sound (performance)
Sound (performance) U-value Insulation (performance)
Insulation (performance) Fire (performance) Material
Material Sound (performance) Weight
Weight Insulation (performance) Surfaces
Material Manufacturer/supplier
Weight
Surfaces

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FLOOR 23


Ceiling

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The ceiling's location is The ceiling is represented by a Construction of suspended The ceiling contains dimensions Ceiling’s manufacturer-specific
represented either by the placeholder with an ceiling in layers such as of ceiling tiles and placement of details are modelled. Details,
surface geometry (2D-planes) approximate geometry which, insulation and plaster, including the suspension system. joints and profiles are modelled
and form or through a for example, shows a approximate openings and Openings for installations and in 3D.
geometric placeholder with an suspended floor at the required details are clarified. Openings lighting fixtures are accurate.
approximate geometry. height for any installation, and for installations and lighting LOI
the like. Approximate location, fixtures are listed in the tiled LOI Type
LOI size and orientation of openings ceiling system. Type Dimensions
Type / holes (shafts, stairs, etc.) Are Dimensions Elevations
Dimensions (approx.) indicated. LOI Elevations Classifications
Type Classifications Material
LOI Dimensions Material System type
Type Elevations System type Manufacturer/supplier
Dimensions Classifications Manufacturer/supplier
Elevations Material
Classifications System type

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CEILING 24


Elevator

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The location of the elevator The elevator shaft is divided The shaft’s exact dimensions Elevator car is modelled. The elevator’s manufacturer
shaft is represented either by into the shaft itself and the are known. Doors and external fittings are specific details are modelled.
the surface geometry and necessary pit and top of the Placement of doors and service modelled. Details, connections and
shape or through a geometric elevator shaft. hatches are set. profiles are modelled in 3D.
placeholder with an LOI
approximate geometry. LOI LOI Type LOI
Type Type Dimensions Type
LOI Dimensions Dimensions Elevation Dimensions
Type Elevation Elevation Elevation
Classification
Dimensions
Classification Classification Load Classification
Load
Load Load Number of floors Load
Number of floors
Number of floors Number of floors Electrical (power) requirements Number of floors
Electrical (power) requirements Electrical (power) requirements Materials Electrical (power) requirements
Materials Surfaces Materials
Surfaces Manufacturer/Supplier Surfaces
Manufacturer/Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ELEVATOR 25


Door

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The placement of the door is Area of frame and door leaf is Exact dimensions for frame and Handles are added. Door’s manufacturer specific
represented either by surface separated. Approximate door leaf are modelled. details are modelled. Details,
geometry and shape or by a dimensions. LOI connections and profiles are
geometric placeholder with LOI Type modelled.
approximate geometry. LOI Type Dimensions
Type Dimensions Function LOI
LOI Dimensions Function Type
Elevation
Type Function Dimensions
Elevation Classification
Dimensions Function
Elevation Classification Material
Function.
Classification Material The opening direction Elevation
Material The opening direction Suspension direction Classification
The opening direction Suspension direction Room number Material
Suspension direction Room number U-value The opening direction
U-value Fire requirements Suspension direction
Fire requirements Audio requirements Room number
Audio requirements Lock system U-value
Lock system Fire (performance) Fire requirements
Fire (performance) Sound (performance) Audio requirements
Sound (performance) Insulation (performance) Lock system
Insulation (performance) Fire (performance)
Sound (performance)
Insulation (performance)
Manufacturer/supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - DOOR 26
Window

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Placement of the window is Area of frame and window is Exact dimensions are modelled Handles are added. The window’s manufacturer
represented either by surface separated. Approximate in 3D for frame and sash. specific details are modelled.
geometry (2D-planes) and dimensions. LOI Details, connections and
shape or by a geometric LOI Type profiles are modelled in 3D.
placeholder with approximate LOI Type Dimensions
geometry. Type Dimensions Elevation LOI
Dimensions (approx.) Elevation Classification Type
LOI Elevation Dimensions
Classification Material
Classification Material The opening direction Elevation
Type
Material The opening direction Suspension direction Classification
Dimensions (approx.)
The opening direction Suspension direction U-value Material
Suspension direction U-value Audio requirements The opening direction
Audio requirements Lock systems Suspension direction
Lock systems U-value
Audio requirements
Lock systems
Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - WINDOW 27


Structures

Foundation, concrete element 


Foundation, insitu 
Slab – terrain, insitu 
Concrete slab, element 
Concrete slab, in-situ 
Light slab, steel 
Concrete Beam, element 
Concrete Beam, insitu 
Concrete Wall, element 
Concrete Wall, insitu 
Concrete Column, element 
Concrete Column, insitu 
Frame 
Steel Beam 
Steel Column 
Staircase, insitu 
Staircase, element 
Staircase, steel 

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STRUCTURES 28


Foundation, concrete element

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The foundation location is The foundation is represented The foundation has real The foundation contains holes The foundation contains
represented either by the as a generic foundation object quantities, dimensions, shape and recesses. Moreover, the chamfers, location of embedded
external surface geometry (in with an approximate shape, and location. Moreover the insulation modelled. partsand main reinforcements
plane) and form or by a where quantities, size, shape, orientation. appears in the modelle
geometric placeholder with an location and orientation is Phasing plus slopes and holes LOI including laps and hooks.
approximate geometry. The specified. plusrecesses are included. Type
placeholder may be a base Reinforcement plus building Dimensions LOI
plate that shows the entire LOI parts and connection details are Elevation Type
foundation. Type clarified. Classification Dimensions
Dimensions Materials Elevation
LOI Elevation LOI Reinforcement Classification
Type Classification Type Concrete strength Materials
Dimensions (approx.) Materials Dimensions Environmental class Reinforcement
Elevation Blinding layer Concrete strength
Classification Concrete, coarse Environmental class
Materials Blinding layer
Reinforcement degree Concrete, coarse
Surface Requirements /
performance requirements
elevation Tolerances
Drying Protection
maturity Hours
density
Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FOUNDATION, CONCRETE ELEMENT 29
Foundation, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The foundation location is The foundation is represented The foundation has real The foundation contains holes The foundation contains
represented either by the as a generic foundation object quantities, dimensions, shape and recesses. Moreover, the recesses plus holes, joints and
external surface geometry (in with an approximate shape, and location. Moreover the insulation modelled. construction joints. Moreover is
plane) and form or by a where quantities, size, shape, orientation. insulation modelled.
geometric placeholder with an location and orientation is Phasing plus slopes and holes LOI
approximate geometry. The specified. plusrecesses are included. Type LOI
placeholder may be a base Reinforcement plus building Dimensions Type
plate that shows the entire LOI parts are clarified but are not Elevation Dimensions
foundation. Type modelled. Classification Elevation
Dimensions Materials Classification
LOI Elevation LOI Reinforcement Materials
Type Classification Type Concrete strength Reinforcement
Dimensions (approx.) Materials Dimensions Weight Concrete strength
Elevation Environmental class Weight
Classification Density Environmental class
Materials Blinding layer Density
Reinforcement degree Concrete, coarse Blinding layer
Concrete class Concrete, coarse
Weight Surface Requirements /
performance requirements
Elevation tolerances
Drying Protection
Maturity Hours
Manufacturer / Supplier
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FOUNDATION, INSITU 30
Slab – terrain, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The foundation location is The foundation is represented The foundation has real Reinforcement appears in 3D Supplier specific details are
represented either by the as a generic foundation object quantities, dimensions, and (possible partly) recesses for modelled as assemblies and eg.
external surface geometry and with an approximate shape, shape plus location and installations and embedded parts’ reinforcement is detailed in 3D,
form or by a geometric what concerns quantities, size, orientation is specified. location an dimensions are and embedded parts are
placeholder with an shape, location and orientation. Recesses/holes >ø500 appears specified. In addition is insulation modelled.
approximate geometry. in the geometry. modelled.
LOI Reinforcement and building LOI
LOI Type details are clarified, but is not LOI Type
Type Dimensions modelled. Type Dimensions
Dimensions (approx.) Elevation Dimensions Elevation
Classification LOI Elevation Classification
Materials Type Classification Materials
Dimensions Materials Reinforcement
Elevation Main reinforcement Surface Requirements /
Classification Concrete strength performance requirements
Materials Environmental class Elevation tolerances
Drying Protection
Maturity Hours
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SLAB – TERRAIN, INSITU 31


Concrete slab, element

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The deck’s locatipon is The slab is represented as a The deck has accurate The model is devided Manufacturer specific details
represented either by exterior generic object with an quantities, dimensions and forprefabrication. are modelled, such as
surface geometry and shape or approximate design in terms of shape - location and orientation Reinforcement is shown in 3D connections and eg.
by a geometric placeholder with quantity, size, shape, location is modelled. (possibly partial). reinforcement is detailed in 3D
an approximate geometry. and orientation. Recesses/holes >ø500 appears Recesses/holes for installations and embedded components are
in the geometry. Reinforcement and embedded parts’ accutale modelled.
LOI LOI and buildingdetailsare clarified, location and dimensions are
Type Type but do not appear in the model. specified. Moreover is insulation
Dimensions (approx.) Dimensions modelled.
LOI
Elevations LOI If any exchange beams and Type
Classification Type flattened steel.
Dimensions
Material Dimensions
Elevations
Elevations LOI Classification
Classification Type
Material
Material Dimensions
Reinforcement
Elevations Concrete strength
Classification
Environment classWeight
Material
Surface Requirements /
Main reinforcement performance requirements
Concrete strength
Elevation tolerances
Environmental class
Drying Protection
Maturity Hours
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE SLAB, ELEMENT 32


Concrete slab, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The slab position is represented The slab is represented as a The deck has accurate Reinforcement is modelled in Manufacturer specific details
either by exterior surface generic object with an quantities, dimensions and 3D (possibly partial). are modelled, as connections
geometry and shape or by a approximate design in terms of shape - location and orientation Recesses/holes for installations and eg. reinforcement is
geometric placeholder with an quantity, size, shape, location is illustrated. and embedded parts accurate detailed in 3D and embedded
approximate geometry. and orientation. Recesses/holes >ø500 appears location and dimensions are components are modelled.
in the geometry. modelled. Moreover insulation
LOI LOI Building part and assembly is modelled. LOI
Type Type details are clarified. Exchange
Type
Dimensions (approx.) Dimensions beams and flattened steel os LOI
Dimensions
Elevations modelled. Reinforcement and Type Elevations
Classification building details have been Dimensions
Classification
Materials clarified, but do not appear in Elevations
Materials
the model. Classification Reinforcement
Materials
Concrete strength
LOI Main reinforcement
Environment class
Type Concrete strength Surface Requirements /
Dimensions Environment class
performance requirements
Elevations
Elevation tolerances
Classification Drying Protection
Materials
Maturity Hours
Reinforced joints
Concrete joints
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE SLAB, INSITU 33


Light slab, steel

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The deck’s locations is Main beams location and Beam sizes are clarified and Actual and final beam profiles The model contains all the
represented either by an orientation including their mutual distances and with the exact location and details about the steel slab
exterior surface geometry and categorization of beams’ top and supports are defined. dimensions are modeled including plates, bolts,
shape or by a geometric bottom are modeled plus Recesses/holes > ø500 appears including bigger bolts. connections etc.
placeholder with an approximate dimensions. within the geometry.
approximate geometry. LOI LOI
LOI LOI Type Type
LOI Type Type Dimensions Dimensions
Type Dimensions (approx.) Dimensions Elevations Elevations
Dimensions (approx.) Elevations Elevations Classifications Classifications
Classifications Classifications Materials Materials
Materials Materials Steel strength Steel strength
Steel strength Fire requirements Fire requirements
Corrosion protection Corrosion protection
Installation Tolerance
adhesive Anchor
Semi / drilling depth + type
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LIGHT SLAB, STEEL 34


Concrete Beam, element

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The beam position is The beam is represented as a The beam has actual quantities, The beam includes chamfers, The beam is divided for
represented either by the generic beam object with an dimensions and shape - location location of embedded prefabrication.
external surface geometry and approximate design in terms of and orientation is specified. components, joints and casting Reinforcement is detailed and
form or as a geometric quantities, size and shape plus Tampering and slopes plus joints. Moreover recesses and includs laps and hooks.
placeholder with an location and orientation is holes/recesses are modelled. insulations is modelled.
approximate geometry. given. Reinforcement and building LOI
details are clarified. LOI Type
LOI LOI Type Dimensions
Type Type LOI Dimensions Elevations
Dimensions (approx.) Dimensions Type Elevations Classification
Elevations Dimensions Classification Material
Classification Elevations Material Reinforcement
Material Classification Main reinforcement Concrete strength
Material Concrete strength Environmental class
Environmental class Surface Requirements /
performance requirements
Elevation tolerances
Drying protection
Maturity hours
Reinforced joints
Concrete joints
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE BEAM, ELEMENT 35


Concrete Beam, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The beam position is The beam is represented as a The beam has actual quantities, The beam includes chamfers, Reinforcement is detailed and
represented either by the generic beam object with an dimensions and shape - location location of embedded includs laps and hooks.
external surface geometry and approximate design in terms of and orientation is specified. components, joints and casting
form or as a geometric quantities, size and shape plus Tampering and slopes plus joints. Moreover recesses and LOI
placeholder with an location and orientation is holes/recesses are modelled. insulations is modelled. Moreover Type
approximate geometry. given. Reinforcement and building holes for reinforced joints are Dimensions
details are clarified. modeled. Elevations
LOI LOI Classification
Type Type LOI LOI Material
Dimensions (approx.) Dimensions Type Type Reinforcement
Elevations Dimensions Dimensions Concrete strength
Classification Elevations Elevations Environmental class
Material Classification Classification Surface Requirements /
Material Material performance requirements
Main reinforcement Elevation tolerances
Concrete strength Drying protection
Environmental class Maturity hours
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE BEAM, INSITU 36


Concrete Wall, element

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The wall's location is represented The wall is represented as a The wall has accurate quantities, The model is divided for Manufacturer specific details
either by a surface or by a generic object with an dimensions and shape - location prefabrication. are modelled as connections
geometric placeholder with an approximate design in terms of and orientation is specified. Recesses/holes for installations and eg. reinforcement is
approximate geometry. quantity, size, shape, location Holes for beams, doors and >ø150 plus embedded detailed in 3D.
and orientation. windows plus holes for componets accurate locations
LOI Openings installations >ø350 appears. and dimensions are modelled. LOI
Type (doors/windows/shaft/etc.) Building details are clarified. Building details are clarified. Type
Dimensions (approx.) appears. Moreover insulation is modelled. Dimensions
LOI Materials
LOI Type LOI Elevations
Type Dimensions Type Classification
Dimensions Materials Dimensions Reinforcements
Elevations Elevations Materials Concrete strength
Classification Classification Elevations Environmental class
Classification Weight
Main reinforcements Surface Requirements /
Concrete strength performance requirements
Environmental class Elevations tolerances
Drying protection
Maturity hours
Reinforced joints
Concrete joints
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE WALL, ELEMENT 37


Concrete Wall, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The wall's location is represented The wall is represented as a The wall has accurate quantities, Recesses/holes for installations Manufacturer specific details
either by a surface or by a generic object with an dimensions and shape - location >ø150 plus embedded are modelled as connections
geometric placeholder with an approximate design in terms of and orientation is specified. componets accurate locations and eg. reinforcement is
approximate geometry. quantity, size, shape, location Holes for beams, doors and and dimensions are modelled. detailed in 3D.
and orientation. windows plus holes for Building details are clarified.
LOI Openings installations >ø350 appears. Moreover insulation is modelled. LOI
Type (doors/windows/shaft/etc.) Building details are clarified. Type
Dimensions (approx.) appears. LOI Dimensions
LOI Type Materials
LOI Type Dimensions Elevations
Type Dimensions Materials Classification
Dimensions Materials Elevations Reinforcement
Elevations Elevations Classification Concrete strength
Classification Classification Main reinforcements Concrete class
Concrete strength Environmental class
Environmental class Surface Requirements /
performance requirements
Elevations tolerances
Drying protection
Maturity hours
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE WALL, INSITU 38


Concrete Column, element

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The column's location is The column is represented as a Actual quantities, size and The column contains recesses Manufacturer Specific details
represented by either a line or generic column object with shape including holes, location with precise dimensions and are modeled as chamfers,
by a geometric placeholder with approximate quantities, size and orientation. location. Depending on type: joints and eg. reinforcement is
an approximate geometry. and shape. Location and Brackets appears within the chamfers, location of embedded detailed in 3D and embedded
orientation is shown. geometry. Building details are components, joints and components are modeled.
LOI clarified. construction joints or
Type LOI end plates, brackets, stiffening LOI
Type LOI plates and the like. Type
Dimensions (approx) Type Dimensions
Elevations Dimensions LOI Elevations
Classification Elevations Type Classification
Main reinforcement Classification Dimensions Reinforcement
Reinforcement degree Elevations Material
Material Classification Concrete strength
Main reinforcement Environmental class
Material Surface Requirements /
Concrete strength performance requirements
Environmental class Elevation tolerances
Drying Protection
Maturity hours
Manufacturer / Supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE COLUMN, ELEMENT 39


Concrete Column, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The column's location is The column is represented as a Actual quantities, size and The column contains recesses Manufacturer Specific details
represented by either a line or generic column object with shape including holes, location with precise dimensions and are modeled as chamfers,
by a geometric placeholder with approximate quantities, size and orientation. location. Depending on type: joints and eg. reinforcement is
an approximate geometry. and shape. Location and Brackets appears within the chamfers, location of embedded detailed in 3D and embedded
orientation is shown. geometry. Building details are components, joints and components are modeled.
LOI clarified. construction joints or
Type LOI end plates, brackets, stiffening LOI
Type LOI plates and the like. Type
Dimensions (approx) Type Dimensions
Elevations Dimensions LOI Elevations
Classification Elevations Type Classification
Classification Dimensions Main reinforcement
Main reinforcement Elevations Material
Classification Concrete strength
Main reinforcement Environmental class
Material Weight
Concrete strength Surface Requirements /
Environmental class performance requirements
Elevation tolerances
Drying Protection
Maturity hours
Reinforced joints
Concrete joints
MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - CONCRETE COLUMN, INSITU 40
Manufacturer / Supplier
Frame

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The frame's location is The framework is represented The frame is represented as a The frame contains recesses Manufacturer specific details
represented by either a line or as a generic object with generic object of actual with precise dimensions and are modelled, eg. connections
through a geometric placeholder approximate quantities, size quantities, size and shape. location inkl. Fire protection. and reinforcement is detailed in
with an approximate geometry. and shape. Location and Location and orientation is shown. Depending on type: 3D and cast-in items are
orientation is shown. Brackets is shown in the chamfers, location of embedded modelled.
LOI geometry. Building detail are parts, joints and construction
Type LOI clarified. joints or end plates, brackets, LOI
Material (approx.) Type stiffening plates and the like. Type
Dimensions LOI Material of the assembly Dimensions
Elevation Type components are shown at joints Elevations
Dimensions where used. Classification
Classification
Elevations Material
Material
Classification LOI Fire safety
Material Type Steel strength
Dimensions Weight
Elevations Fire protection
Classification Corrosion protection
Material Manufacturer/supplier
Fire safety
Steel strength
Weight

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - FRAME 41


Steel Beam

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The beam position is The beam is represented as a The beam has real quantities, The beam includes end plates The beam is divided for
represented either by the generic beam object with an dimensions and shape - location and brackets as well as body prefabrication.
external surface geometry and approximate design in terms of and orientation is specified. stiffening and fire insulation.
form or by a geometric quantities, size and shape. Holes/recesses for installations Assembling details and holes for LOI
placeholder with an Location and orientation is are modelled. reinforced joints has been Type
approximate geometry. given. Building detaila are clarified. clarified. Dimensions
Elevations
LOI LOI LOI LOI Classification
Type Type Type Type Material
Dimensions (approx.) Dimensions Dimensions Dimensions Fire requirements
Elevations Elevations Elevations Surface treatment
Classification Classification Classification Steel Strength
Material Material Material Corrosion protection
Fire requirements Fire requirements Mounting Tolerance
Surface treatment Adhesive Anchor
Steel Strength Semi / drilling depth
Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STEEL BEAM 42


Steel Column

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The column position is The column is represented as a The column has real quantities, The column includes end plates The column is divided for
represented either by the generic column object with an dimensions and shape - location and brackets as well as body prefabrication.
external surface geometry and approximate design in terms of and orientation is specified. stiffening and fire insulation.
form or by a geometric quantities, size and shape. If any, holes/recesses for Assembling details and holes for LOI
placeholder with an Location and orientation is installations are modelled. reinforced joints has been Type
approximate geometry. given. Building detaila are clarified. clarified. Dimensions
Elevations
LOI LOI LOI LOI Classification
Type Type Type Type Material
Dimensions (approx.) Dimensions Dimensions Dimensions Fire requirements
Elevations Elevations Elevations Surface treatment
Classification Classification Classification Steel Strength
Material Material Material Corrosion protection
Fire requirements Fire requirements Mounting Tolerance
Surface treatment Adhesive Anchor
Steel Strength Semi / drilling depth
Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STEEL COLUMN 43


Staircase, insitu

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The location of the staircase is The staircase is represented by The staricase is modelled The staircase is divided for All staircase elemnts are
represented by a geometric a generic object with a specifying the exact location og prefabrication. Holes/recesses specified.
placeholder with an simplified specification of the the stair steps and landing for installations are modeled.
approximate geometry. stair steps and landing including greater support LOI
locations. elements and with an indication LOI Type
LOI of secondary structural Type Dimensions
Type LOI elements. Dimensions Elevation
Dimensions (approx.) Type Elevation Classifikation
Dimensions (approx.) LOI Classifikation Material
Elevation Type Material Surface requirements
Classifikation Dimensions Surface requirements Reinforcement
Material Elevation Main reinforcement Manufacturer/supplier
Classifikation
Material

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STAIRCASE, INSITU 44


Staircase, element

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The location of the staircase is The staircase is represented by The staricase is modelled The staircase is divided for All staircase elemnts are
represented by a geometric a generic object with a specifying the exact location og prefabrication. Holes/recesses specified.
placeholder with an simplified specification of the the stair steps and landing for installations are modeled
approximate geometry. stair steps and landing including greater support and secondary structural LOI
locations. elements. elements are specified. Type
LOI Dimensions
Type LOI LOI LOI Elevation
Dimensions (approx.) Type Type Type Classifikation
Dimensions (approx.) Dimensions Dimensions Material
Elevations Elevations Elevation Surface requirements
Classifikation Classifikation Classifikation Reinforcement
Material Material Material Manufacturer/supplier
Surface requirements
Main reinforcement

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STAIRCASE, ELEMENT 45


Staircase, steel

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The location of the staircase is The staircase is represented by The staricase is modelled The staircase is divided for All staircase elemnts are
represented by a geometric a generic object with a specifying the exact location og prefabrication. Holes/recesses specified.
placeholder with an simplified specification of the the stair steps and landing for installations are modeled
approximate geometry. stair steps and landing including greater support and secondary structural LOI
locations. elements. elements are specified. Type
LOI Dimensions
Type LOI LOI LOI Elevations
Dimensions (approx.) Type Type Type Classifikation
Dimensions (approx.) Dimensions Dimensions Material
Elevations Elevations Elevations Fire requirements
Classifikation Classifikation Classifikation Steel strength
Material Material Material Corrosion protection
Fire requirements Surface treatment
Steel strength Mounting tolerance
Corrosion protection Adhesive anchor
Semi/drilling depth
Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - STAIRCASE, STEEL 46


Installations

Utility 
Pipe services, terrain 
Water-carrying installations (heating, drainage
(rainwater/sewage), domestic water, cooling and
sprinkling) 
Air born installations 
Ventilation 
Electricity 
Low voltage (CTS & IT and data communication,
security, personal security access security) 

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - INSTALLATIONS 47


Utility

LOD 100 LOD 200 LOD 300 3 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The main routing trays are Aapproximate location and size Actual geometry, design and Detailed geometry with actual Supplier-specific connections
represented by a geometric of the main and secondary location of main installations sizes, location, design, access and details are modelled in 3D.
placeholder with an installations routes . routes including needed spaces requirement for installations Servies areas are modelled.
approximate geometry or Approximate space for service acces incl. space including suspensions and
schematic diagrams. requirements for access must need for suspension including supports. LOI
Supply plants represents: be represented in the model. type, supports, etc. Insulations Type
cooling plant, heating plant, Approximate location of is modelled. Connections and LOI Dimensions (approx.)
sprinkler plant, ventilations exchangers, boilers, pumps, aggregate types (counter flow, Type Elevations
plant, distributions center main tankts etc. rotary or plate heat exchanger) Dimensions (approx.) Classification
electrical panels and are modelled. Elevations Comsumptions
swichtboards incl. service LOI
Classification System name
agreements. Type LOI
Comsumptions Materials
Dimensions (approx.) Type
System name Manufacturer/supplier
LOI Elevations Dimensions (approx.)
Type Elevations Materials
Classification
Dimensions (approx.) Classification Manufacturer/supplier
Comsumptions
Consumption Comsumptions
System name
System name
Materials

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - UTILITY 48


Pipe services, terrain

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The main routing paths are Generic layout, approximate Actual dimensions, locations, Detailed geometry. Supplier-specific connections
represented by a geometric location and size of the main design of main and secondary and details are modelled in 3D.
placeholder with an and secondary installationtion installations routes. . Material LOI
approximate geometry or as routes including valveslines. thichkness of pipes and valves Type LOI
schematic diagrams. Approximate space locations er modelled. Dimensions Type
requirements for access are Elevations Dimensions
LOI represented in the model. LOI Elevations
Classification
Type Locations of wall and slap Type
System name Classification
Dimensions penetrations (fire and audio Dimensions
Performance requirements System name
Consumption(approx.) seling). Elevations
Materials Performance requirements
Classification
LOI System name Capacity Materials
Performance requirements Capacity Manufacturer /supplier
Type
Dimensions (approx.) Materials
Elevations
Classification
System name
Performance requirements

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - PIPE SERVICES, TERRAIN 49


Water-carrying installations (heating, drainage (rainwater/sewage), domestic water, cooling and sprinkling)

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The main installation routing Approximate location and size Pipe dimensions and bends are Detailed geometry, with actual Supplier-specific connections
paths are represented by a of the main and secondary determined including locations sizes, location and design. and details are modelled in 3D
geometric placeholder with an pipes. Approximate space and design with needed slope. Fittings, bends and all types of plus suspension, brackets and
approximate geometry or as (shafts)requirements are Free space for pipes including valves, fasteners and pipes supports.
schematic diagrams. represented in the model. insulation is modelled. Pumps, including thickness.
Location of wall and slap cleaning hatches, blancing LOI
LOI penetrations (fire and sound valves, radioators, sanitary, LOI Type
Type sealing). etc. Sprinnklers and other Type Dimensions
Dimensions (approx.) components in the suspended Dimensions Elevations
System name LOI ceiling are modelled. Elevations Klassification
Type Klassification System name
Dimensions (approx.) LOI
System name Materials
Elevations Type
Materials Manufacturer/supplier
Classification Dimensions
Manufacturer/supplier
System name Elevations
Klassification
System name
Materials

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - WATER-CARRYING INSTALLATIONS (HEATING, DRAINAGE (RAINWATER/SEWAGE), DOMESTIC WATER, COOLING AND SPRINKLING) 50
Air born installations

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


The main installation routing Approximate location and size Pipe dimensions and bends are Detailed geometry, with actual Supplier-specific connections
paths are represented by a of the main and secondary determined including locations sizes, location and design. and details are modelled in 3D
geometric placeholder with an pipes. Approximate space and design. Free space and Fittings, bends and all types of plus suspension, brackets and
approximate geometry or as (shafts)requirements are clearance and fire insulations at valves, fasteners and pipes supports.
schematic diagrams. represented in the model. pipes are modelled. Fittings including thickness.
Location of wall and slap multi boxes, balancing valves, LOI
LOI penetrations (fire and sound etc. Alle components in the LOI Type
Type sealing). suspended ceiling are Type Dimensions
Dimensions (approx.) modelled. Dimensions Elevations
System name LOI Elevations Classification
Type LOI
Classification System name
Dimensions (approx.) Type
System name Materials
Elevations Dimensions
Materials Manufacturer/supplier
Elevations
Classification Manufacturer/supplier
Classification
System name
System name
Materials

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - AIR BORN INSTALLATIONS 51


Ventilation

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Main routing paths represented Approximate location and size Duct dimensions are accurate Detailed geometry of all duct Supplier-specific connections
by a geometric placeholder with of the main and secondary including location and desing. routes with actual sizes, locations and details are modelled in 3D.
an approximate geometry or as ducts. Approximate space The system includes insulation, and design, space requirements Suspensions and supports.
schematic diagrams. (shaft) requirements are fixtures and fittings that all are for access needs for both ducts
represented in model. Locations modelled. and dampers, silencers and LOI
LOI of wall and floor penetrations fittings. Type
Type (fire and audio sealing). LOI Dimensions
Dimensions (approx.) Type LOI Elevations
System name LOI Dimensions Type Classification
Type Elevations Dimensions System name
Dimensions (approx.) Classification Elevations Air flow
Elevations System name
Classification Manufacturer/supplier
Air flow
Classification System name
System name Air flow
Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - VENTILATION 52


Electricity

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Main cable trays, blackboards Cable tray routing and location Actual dimensions, location Detailed geometry with actual Supplier-specific connections
and approximate dimensions, of blackboards, Dimensions including bends and fittings. sizes, location, design including and details are modelled in 3D.
location and design. location and design is detailed. Location and dimensions of suspension type and its space Suspension, brackets and
Approximate space Approximate space fixtures and switches plus requirements. supports are modeled
requirements for service access requirements for acces to black mounting boxes and draft tube
and clearances. boards. Location og wall and in concrete elements. Location LOI LOI
slap penetrations (fire and of visible secondary cable trays Type Type
LOI sound sealing) including all relevant low Dimensions Dimensions
Type voltage components. Elevation Elevation
Dimensions (approx.) LOI Classification Classification
Type LOI System name System name
Dimensions Type Materials Materials
Elevation Dimensions Manufacturer/supplier Manufacturer/supplier
Classification Elevation
System name Classification
System nameMaterials

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - ELECTRICITY 53


Low voltage (CTS & IT and data communication, security, personal security access security)

LOD 100 LOD 200 LOD 300 LOD 350 LOD 400

LOD LOD LOD LOD LOD


Approximate space Low voltage components in the All low voltage components are All low voltage components are All low voltage components are
requirements for service access suspended ceiling is modelled, both in the cerilings, modelled, both in the cerilings, modelled, both in the cerilings,
of boards / panels incl. represented in the model. walls and floors. The location walls and floors. The location walls and floors. The location
clearances represented by a Switchboards and switches are and size are specified med and size are specified med and size are specified med
deputy. specific (technical rooms and exact dimensions in the model. exact dimensions in the model. exact dimensions in the model.
shaft) space requirements for
LOI access to boeards etc. LOI LOI LOI
Type Type Type Type
Dimensions (approx.) LOI Dimensions Dimensions Dimensions
Type Elevation Elevation Elevation
Dimensions (approx.) Classification Classification Classification
Elevation System name System name System name
Classification Manufacturer/supplier Materials
System name Manufacturer/supplier

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - LOW VOLTAGE (CTS & IT AND DATA COMMUNICATION, SECURITY, PERSONAL SECURITY ACCESS SECURITY) 54
Sample of Model Progression Specification – MPS

Sample of the Model Progression Specification - MPS in relation to milestones. LOD acc. to
"Building Component Catalogue with information levels (LOD)". The plan must be adapted for the indicidual project, and the following are only filled ind as an example.

PRELIMINARY DETAILED SUPPLIER AS BUILT AND


PROJECT DESIGN MODEL OPERATIONAL
PHASE PHASE PHASE*
DISCIPLINE

PROPERTIES

PROPERTIES

PROPERTIES

PROPERTIES
OBJECT TYPE
GEOMETRY

GEOMETRY

GEOMETRY

GEOMETRY
LOD LOI LOD LOI LOD LOI LOD LOI

Terrain 200 0 300 300 300 0 * *

Levelling/gradings 200 0 300 0 350 0 * *

Excavation for foundations 200 0 350 0 0 0 * *


INFRASTRUCTURE

Excavation for pipes 200 0 300 0 350 0 * *

Road and railway 300 0 350 0 400 0 * *

Road and railway 200 0 300 0 350 0 * *


equipment

Dam 200 0 350 0 400 0 * *

Existing pipework 200 0 300 350 0 0 * *

Drainage 200 0 300 0 350 0 * *

*) To be agreed upon with the client at the project start-up

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 55
Sample of Model Progression Specification – MPS

PRELIMINARY DETAILED SUPPLIER AS BUILT AND


PROJECT DESIGN MODEL OPERATIONAL
PHASE PHASE PHASE*
DISCIPLINE

PROPERTIES

PROPERTIES

PROPERTIES

PROPERTIES
OBJECT TYPE

GEOMETRY

GEOMETRY

GEOMETRY

GEOMETRY
LOD LOI LOD LOI LOD LOI LOD LOI

Room 200 200 300 300 400 400 * *

Roof 200 300 350 350 400 400 * *

Light façade 200 300 350 350 400 400 * *

Heavy façade 200 300 350 350 0 0 * *


ARCHITECT

Light Interior Walls 200 300 300 300 0 0 * *

Floor 200 300 300 300 0 0 * *

Ceiling 200 300 350 350 0 0 * *

Elevator 200 300 200 300 400 400 * *

Door 200 300 200 400 400 400 * *

Window 200 300 350 350 400 400 * *

*) To be agreed upon with the client at the project start-up

MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 56
Sample of Model Progression Specification – MPS

PRELIMINARY DETAILED SUPPLIER AS BUILT AND


PROJECT DESIGN MODEL OPERATIONAL
PHASE PHASE PHASE*
DISCIPLINE

PROPERTIES
PROPERTIES

PROPERTIES

PROPERTIES
GEOMETRY
OBJECT TYPE

GEOMETRY

GEOMETRY

GEOMETRY
LOD LOI LOD LOI LOD LOI LOD LOI

Foundation, conc. element 200 300 300 300 0 0 * *

Foundation, insitu 200 300 300 300 0 0 * *

Slap – terrain, insitu 200 300 300 300 350 400 * *

Concrete slap, element 200 300 300 300 350 400 * *

Concrete slap, insitu 200 300 300 300 350 400 * *

Light slap, steel 200 300 300 300 350 400 * *

Concrete beam, element 200 300 300 300 350 400 * *

Concrete beam, insitu 200 300 300 300 350 400 * *


STRUCTURES

Concrete wall, element 200 300 300 300 350 400 * *

Concrete wall, insitu 200 300 300 300 350 400 * *

Concrete column, element 200 300 300 300 350 400 * *

Concrete column, insitu 200 300 300 300 350 400 * *

Frame 200 300 300 300 400 400 * *

Steel beam 200 300 300 300 350 400 * *

Steel column 200 300 300 300 350 400 * *

Staircase, insitu 200 300 300 300 350 400 * *

Staircase, element 200 300 300 300 350 400 * *

Staircase, steel 200 300 300 300 350 400 * *


MT HØJGAARD A/S - BUILDING COMPONENT CATALOGUE - SAMPLE OF MODEL PROGRESSION SPECIFICATION – MPS 57
*) To be agreed upon with the client at the project start-up
Sample of Model Progression Specification – MPS

PRELIMINARY DETAILED SUPPLIER AS BUILT AND


PROJECT DESIGN MODEL OPERATIONAL
PHASE PHASE PHASE*
DISCIPLINE

PROPERTIES

PROPERTIES

PROPERTIES

PROPERTIES
OBJECT TYPE

GEOMETRY

GEOMETRY

GEOMETRY

GEOMETRY
LOD LOI LOD LOI LOD LOI LOD LOI

Utility 200 300 200 300 350 400 * *

Pipe services, terrain 200 300 300 350 0 0 * *


INSTALLATIONS

Water-carrying installations 200 300 300 350 0 0 * *

Air born installations 200 300 300 350 0 0 * *

Ventilation 200 300 200 350 400 0 * *

Electricity 200 300 300 350 0 0 * *

Low voltage 200 300 300 350 0 0 * *

*) To be agreed upon with the client at the project start-up