Sei sulla pagina 1di 2

Well Integrity Management

System (WIMS) Workflow

Action Items
Well Integrity Management System
Presentation
Answering on WIMS Questionnaire

Gap Analysis

Well Integrity Management Policy / Strategy


Well Integrity Assurance Management
System
Well Integrity Contingency Plan

Well Integrity Report Template

Well Integrity Checklists & Routine Testing


Format
Well Integrity Management System (WIMS) Questionnaire
Client Field Type Location Date Author

Mahmoud F. Radwan

Upsrtream Orgnization Structure


Head Office:

Field:

Communication
List all contacts, Well Integrity Task Force Team, Drlg. / Work-over Dept…etc.
Company name
Name
Title
Cell
Email

Production Data
Prod. Fluid Type Prod. rate MMSCF/D Well Prod. Rate Range MMSCF/D
Condensate Prod. Rate BPD Water Prod. Rate BWPD Condenste Gas Ratio CGR BBL/MMSCF
-
Cl ppm Total Dissolved Solids (TDS) ppm Sand Prod. (Yes / No)
Wellhead Flowing Press. Range psi Flowline Press. Range psi Sand Prod. Rate Lb/day
Wellhead Flowing Temp. Range DegF Flowline Temp. Range DegF Key Performance Indicator
Formation Pressure psi Max. Temperature: DegF Type (Oil-Gas)
CO2 mole % Hydrates expected H2 S (ppm)
Scale Expected Rock Type: Sand Control Mechanism
Scale Condittion (P & T) Paraffin / Wax Expected Hydrate Condition (P & T)
No. of Wells Scale Location Hydrate Location
No. of P & A Wells No. of Producer Wells No. of Injector Wells
No. of Secured or T & A Wells No. of Shut-in Wells Water / Gas Injection

Drilling
Gen. Drlg. Procedure / Manual / RP Available or not Available Drlg. Prog. With Lessons Learnt Available or not Available Major Drlg. Problems
Deviation Angle Range Deg. Depth feet Wells Cards or Montage Available or not Available
Mud Type Drlg. MAASP Calculation Available or not Available DDR & EOWR data base Available or not Available
Wells Hand-over Certificates Available or not Available Casing Material Selection Study Available or not Available Cement Integrity Run Logs
Cement Integrity Logs Interpretation Available or not Available Failure Analysis Available or not Available Cement Type
Rig inspection check list Available or not Available Collapse or Burst Problem in casing Reason for Collapse or Burst Problem
P & A Procedure / RP Available or not Available P & A Prog. Available or not Available
Accountability & Resposability

Work-over
Gen. W/O Procedure / Manual / RP Available or not Available Main Reasons for W/O
W/O Prog. With Lessons Learnt Available or not Available Killing Method Kill Fluid Type & Wt.
Errossion or Corrosion Problem Yes or No Errossion or Corrosion Mechanism Multi-finger Caliper Logs Run Yes or No
Errossion or Corrosion Study Available or not Available DWOR & FWOR data base MAASP Calculation Available or not Available
Casedhole Logging Run Perforation Method Gun Size & Density (SPF)
Investigation Report Available or not Available Collapse or Burst Problem in Tubing Reason for Collapse or Burst Problem
Failure Analysis Available or not Available Wells Hand-over Certificates Available or not Available
Accountability & Resposability

Well Control and Fluids


1st Barrier Fluid Type: BOP Rams Size:
2nd Barrier Fluid Weight: lb/gl BOP Pressure Test: psi
Fluid losses expected BOP Size: Fluid Available (bbl)

Prod. Tubing & Completion


Completion Type Size, Weight, Grade Material Type
SSSV / DHSV Type Controlling Method Schmatic Wells Compl. Skech Available or not Available
Prod. Method N.F or A.L Life time for TBG (averge) Years Chemical Injection & Location Available or not Available/Surface or downhole
Packer Type Engineering Data Sheets for Compl. Available or not Available Failure Analysis Available or not Available
Intelligent Completion PDHGs, ICD, ICV Intelligent Completion Life Time Years Sand Control Life time Years
Inspection & Jamming Reports Record Available or not Available Vendors Evaluation Form Available or not Available
Accountability & Resposability

Wellhead & X-trees


Type Size, Press. rating Material Type
Vendors Manual Or Schematic Drawings Available or not Available Life time Years
Installation, testing, maintenance Procedures Available or not Available Greasing, testing, Maintenance record Available or not Available Failure Analysis Available or not Available
UMV type Actuator No. of Wing Valve 1 or 2 No. of Annuli 2 or 3
No. of Outlet Annuli Valves 1 or 2 Press. & Temp. Mointoring by Manual gauges X-tree Cap Connection size & Type
Inspection Record (online / offline) Available or not Available Cavity testing record Available or not Available Annuli Press. Mointoring & Recording Available for Ann.-A, B
Sustainable Annulus Press. Problem Yes Manual Bleed off/down Method Yes or No Annulus Press. Reason
Choke Type Fixed or Adjustable Material Type & Life time Failure Analysis
Accountability & Resposability

Well Intervetion
Gen. Well Inmtervention Procedure / Manual Available or not Available Main Job Types
Well Intervention Prog. Available or not Available Job Task Risk Assessment Available or not Available Reporting Database Available or not Available
Jobs Results Evaluation Report Available or not Available Failure Analysis Available or not Available Check list for each service Available or not Available
Tagged Depth Record for each well Available or not Available Emergency Procedures for each service Available or not Available MAWOP Calculation Available or not Available
No. of Barriers 2 or 3 Associated Problems Sand or hydrate or scale Stimulation Type Acid or Hydr. Frac.
Accountability & Resposability

Potrebbero piacerti anche