Sei sulla pagina 1di 1

PT.

JASA MUTU MINERAL INDONESIA


Coal Laboratory & Superintending
Jl. Rapak Indah No.189 Samarinda Kalimantan Timur - Indonesia
Telp : (0541) 6276886 Fax : (0541) 6276887
Email : marketing@mutuenergy.com

PRELIMINARY REPORT

Job Number : 2371/LAB/IX/2018 Principle : CV. BINTANG SURYA UTAMA


Date Of Received Sample : September 27, 2018 Reference :
Amount Of Sample : 2 Samples
Date Issued : September 30, 2018
Attention : Mr. Rusdiansyah
Email : rusdy.dewata@gmail.com

CO - BD - 01
CODE SAMPLE
Test Method SS - 3093
Dry Ash As
Basis Air Dried Dry
Free Received
Mass as Received (kg) 5.80
Total Moisture (% m/m) ASTM D3302/D3302M– 17 - - - 10.22
Moisture in the Analysis Sample (% m/m) ASTM D3173/D3173M - 17 8.83 - - -
Ash Content (% m/m) ASTM D 3174 - 12 1.75 1.92 - 1.72
Volatile Matter (% m/m) ASTM D 3175 - 11 42.03 46.10 47.00 41.39
Fixed Carbon ( % m/m) ASTM D 3172 - 13 47.39 51.98 53.00 46.67
Total Sulphur (% m/m) ASTM D 4239 – 14 0.24 0.26 0.27 0.24
Gross Calorific Value (kcal/kg) ASTM D5865 – 13 6629 7271 7413 6528

CO - BD - 02
CODE SAMPLE
Test Method SS - 3094
Dry Ash As
Basis Air Dried Dry
Free Received
Mass as Received (kg) 4.31
Total Moisture (% m/m) ASTM D3302/D3302M– 17 - - - 11.11
Moisture in the Analysis Sample (% m/m) ASTM D3173/D3173M - 17 9.66 - - -
Ash Content (% m/m) ASTM D 3174 - 12 1.69 1.87 - 1.66
Volatile Matter (% m/m) ASTM D 3175 - 11 40.09 44.38 45.22 39.45
Fixed Carbon ( % m/m) ASTM D 3172 - 13 48.56 53.75 54.78 47.78
Total Sulphur (% m/m) ASTM D 4239 – 14 0.33 0.37 0.37 0.32
Gross Calorific Value (kcal/kg) ASTM D5865 – 13 6393 7077 7212 6290

Analysis according to : ASTM Method

Regards,

Ahmad Latif, S.Si


Laboratory Manager