Sei sulla pagina 1di 2

1.

Spacing for a lateral support for a beam shall not exceed _________ times the
least width b of compression flange or face (NSCP 410.5.10)
a) 60 times
b) 50 times
c) 70 times
2. For a rectangular reinforced concrete compression member, it shall be permitted
to take the radius of gyration equal to _____ times the overall dimension of the
direction of stability is being considered (NSCP 410.12.20.)
a) 60 times
b) 50 times
c) 70 times
3. The minimum center to center spacing of stud connectors along the longitudinal
axis of supporting composite beam is ______
a) 6 d of connector
b) 7 d of connector
c) 8 d of connector
4. The maximum center to center spacing of stud connection along the longitudinal
axis of supporting composite beam is ___________.
a) 7 d of connector
b) 6 d of connector
c) 8 d of connector
5. When the formed steel decking is a part of the composite beam, the spacing of
stud shear connection along the length of the spacing beam or girder shall not
exceed ______ minimum (NSCP 506.6.1.2)
a) 700 mm
b) 800 mm
c) 900 mm
6. The minimum sizes of filler weld for plates with thickness greater than 20mm
is____ (NSCP 510.3.3.2)
a) 8 mm
b) 7 mm
c) 6 mm
7. The minimum sizes of filler weld for plates with thickness 6 mm is ______?
(NSCP 510.3.3.2)
a) 2 mm
b) 3 mm
c) 4 mm
8. The minimum sizes of filler weld for plates with thickness over 12 mm to 20 mm
is ______? (NSCP 510.3.3.2)
a) 6 mm
b) 7 mm
c) 5 mm

9. In structural design________________ is considered as wide shallow


rectangular beam. The reinforcing steel is usually spaced uniformly over its
width. The flexural reinforcement of a one-way slab extends in one direction only.
a) Flat slab
b) Two-way slab
c) One-way slab

10. In They may be categorized as building or non-building. It is an assemblage


designed to support gravity loads and resist lateral forces
a) Building
b) Structure
c) Concrete and Steel

11. It’s a vertical pipe, often sheet metal, used to conduct water from a roof drain or
gutter to the ground. It is another term for down spout.
a) Rainwater leader
b) Sump pit
c) Coffer dam

12. The area where the water is pumped from within to permit free access to the
area. A temporary water light enclosure around an area of water or water bearing
soil, in which construction is to take place, bearing on a stable statum at or above
the foundation level of new construction.
a) Rainwater leader
b) Water cistern
c) Coffer dam
13. A membrane structure that is placed in tension and stabilized by the pressure of
compresses air
a) Net structure
b) Tensile structure
c) Web structure

Potrebbero piacerti anche