What is SATACOM? DC Machine
Measurement and Instrumentation
STATCOM or Static Synchronous Compensator is a power electronic device using force
AC Circuit
commutated devices like IGBT, GTO etc. to control the reactive power flow through a power
Digital Electronics
network and thereby increasing the stability of power network. STATCOM is a shunt device
Electrical Drives
i.e. it is connected in shunt with the line. A Static Synchronous Compensator (STATCOM) is
Power Electronics
also known as a Static Synchronous Condenser (STATCON). It is a member of the Flexible
EM Theory
AC Transmission System (FACTS) family of devices.

The terms Synchronous in STATCOM mean that it can either absorb or generate reactive
power in synchronization with the demand to stabilize the voltage of the power network.

Working Principle of STATCOM:

To understand the working principle of STATCOM, we will first have a look at the reactive
power transfer equation. Let us consider two sources V1 and V2 are connected through an
impedance Z = Ra + jX as shown in figure below. Recent Posts

A Case Study on LBB Protection Logic

https://electricalbaba.com/statcom-working-principle-design-and-application/ 1/7
11/28/2019 STATCOM – Working Principle, Design and Application | Electrical Concepts
Single Phase Half Wave Controlled Rectifier
Phase Control of SCR – Definition, Explanation
and Advantage
Firing Angle of SCR Explained
Natural or Line Commutation- Principle with
Circuit Diagram

In the above reactive power flow equation, angle δ is the angle between V1 and V2. Thus if
Subscribe to our mailing list and get
we maintain angle δ = 0 then Reactive power flow will become
interesting stuff and updates to your email
inbox.
Q = (V2/X)[V1-V2]

and active power flow will become Your Email Please

I consent to my submitted data being


collected via this form*

SUBSCRIBE NOW

we respect your privacy and take protecting it


seriously

P = V1V2Sinδ / X =0

To summarize, we can say that if the angle between V1 and V2 is zero, the flow of active
power becomes zero and the flow of reactive power depends on (V1 – V2). Thus for flow of
reactive power there are two possibilities.

1) If the magnitude of V1 is more than V2, then reactive power will flow from source V1 to
V2.

2) If the magnitude of V2 is more than V1, reactive power will flow from source V2 to V1.

This principle is used in STATCOM for reactive power control. Now we will discuss about
the design of STATCOM for better correlation of working principle and design.

You may like to read Reactive Power and Voltage Control of a Transmission Line

Design of STATCOM:

STATCOM has the following components:

1) A Voltage Source Converter, VSC

The voltage-source converter is used to convert the DC input voltage to an AC output


voltage. Two of the common VSC types are as below.

a) Square-wave Inverters using Gate Turn-Off Thyristors: In this type of VSC, output
AC voltage is controlled by changing the DC capacitor input voltage, as the
fundamental component of the converter output voltage is proportional to the DC
voltage.

b) PWM Inverters using Insulated Gate Bipolar Transistors (IGBT): It uses Pulse Width
Modulation (PWM) technique to create a sinusoidal waveform from a DC voltage
source with a typical chopping frequency of a few kHz. In contrast to the GTO-based

https://electricalbaba.com/statcom-working-principle-design-and-application/ 2/7
11/28/2019 STATCOM – Working Principle, Design and Application | Electrical Concepts
type, the IGBT-based VSC utilizes a fixed DC voltage and varies its output AC
voltage by changing the modulation index of the PWM modulator.

2) DC Capacitor

DC Capacitor is used to supply constant DC voltage to the voltage source converter,


VSC.

3) Inductive Reactance

A Transformer is connected between the output of VSC and Power System.


Transformer basically acts as a coupling medium. In addition, Tranformer neutralize
harmonics contained in the square waves produced by VSC.

4) Harmonic Filter

Harmonic Filter attenuates the harmonics and other high frequency components due to
the VSC.

A simplified diagram along with equivalent electrical circuit of STATCOM is shown in figure
below.

Now we will understand how the STATCOM works though we have discussed the basic
operating principle of STATCOM. As can be seen from the figure above, source V1
represents the output voltage of the STATCOM. In case of reactive power demand
increases in the power system, STATCOM increases its output voltage V1 while maintain
the phase difference between V1 and V2 to zero (it shall be noted here that there will
always exists small phase angle between V1 and V2 to cater for the leakage impedance
drop in the interconnecting Transformer ). As V1 > V2, reactive power will flow from
STATCOM to the power system. Thus STATCOM, supplies reactive power and acts as
reactive power generator.

Again, if the voltage of power system increase due to load throw off, STATCOM will reduce
its output voltage V1 and therefore will absorb reactive power to stabilize the voltage to
normal value.

The above mode of operation of STATCOM is called Voltage Regulation Mode.

But as we know every equipment has got their own limitations, so STATCOM must also
have some limitation of supplying or absorbing reactive power. Yes, there exists a limitation
and this limitation is imposed by the current carrying capacity of force commutated devices
like IGBT, GTO etc. Therefore, if the operation of STATCOM reaches their limitation, it does
not further increases or decreases its output voltage V1 rather it supplies or absorbs fixed
reactive power equal to its limiting value at a fixed voltage and current and acts like
constant current source. This mode of operation of STATCOM is called VAR Control Mode.

Thus form the above discussion, the operation of STATCOM can be classified into two
modes:

1) Voltage Regulation Mode

2) VAR Control Mode

The figure below well explains the above two modes of operation of STATCOM.

https://electricalbaba.com/statcom-working-principle-design-and-application/ 3/7
11/28/2019 STATCOM – Working Principle, Design and Application | Electrical Concepts

The figure above is the Voltage Current Characteristics of STATCOM. As can be seen,
voltage regulation capability of STATCOM is from V1 (in lower side) to V2 in upper side of
power system. If the voltage of power system goes below V1 or above V2, STATCOM acts
in VAR Control mode. Here V1 and V2 are just taken for example, it should not be confused
with the V1 (used for output voltage of STATCOM) and V2 (Voltage of power system) used
in the discussion above.

Application of STATCOM:

Voltage stability is one of the biggest problems in power systems. Engineers and
researchers are trying to consolidate a definition regarding to voltage stability, besides
proposing techniques and methodologies for their analysis. Most of these techniques are
based on the search of the point in which the system’s Jacobian becomes singular,
this point is referred as the point of voltage collapse or maximum load ability point.
(we will discuss point of voltage collapse in next post) The series and shunt
compensation are able to increase the maximum transfer capabilities of power network
.Concerning to voltage stability, such compensation has the purpose of injecting reactive
power to maintain the voltage magnitude in the nodes close to the nominal values, besides,
to reduce line currents and therefore the total system losses. Today due the development in
the power electronics devices, the voltage magnitude in some node of the system can be
adjusted through sophisticated and versatile devices named FACTS. One of them is the
static synchronous compensator (STATCOM).

Usually a STATCOM is installed to support electrical networks that have a poor power factor
and often poor voltage regulation. The most common use of STATCOM is for voltage
stability. A STATCOM is a voltage source converter (VSC) based device, with the voltage
source behind a reactor. The voltage source is created from a DC capacitor and therefore a
STATCOM has very little active power capability. However, its active power capability can be
increased if a suitable energy storage device is connected across the DC capacitor.

 November 26, 2016  admin  Electrical Machines  8 Comments  STATCOM

«Load Test or Back to Back Test or Sumpner’s Test Pulse Transformer – An Overview»
of Transformer

https://electricalbaba.com/statcom-working-principle-design-and-application/ 4/7
11/28/2019 STATCOM – Working Principle, Design and Application | Electrical Concepts

8 Thoughts On “STATCOM – Working Principle, Design And


Application”

— Bharat Mohan

says:
December 14, 2017 at 2:36 pm

good information on STATCOM

 Reply

— Unknown

says:
January 4, 2018 at 10:25 pm

So much helpful. I have been looking these kinds of information for few months. Thanks a lot.

 Reply

— Sudha

says:
January 7, 2018 at 12:21 pm

Thank you so much for providing such a information which is very helpfuland easy way to understand

 Reply

— Anonymous

says:
March 19, 2018 at 12:18 am

Really worth and clear explanation

 Reply

— Pawan Singh

says:
https://electricalbaba.com/statcom-working-principle-design-and-application/ 5/7
11/28/2019 STATCOM – Working Principle, Design and Application | Electrical Concepts
October 16, 2018 at 2:16 pm

Really clear cut explainatn.

 Reply

1. — admin

says:
October 16, 2018 at 4:27 pm

Thank you Pawan!

— Unknown

says:
December 11, 2018 at 2:25 am

Explanation was better than book.. Easy to understand! Thank you.. Keep posting more!

 Reply

— Usman

says:
February 6, 2019 at 5:27 pm

Anyone have complete circuit diagram of power factor improvement with statcom?

 Reply

Leave A Reply

Your email address will not be published. Required fields are marked *

 Comment

 Name *

 Email *

 Website

 Notify me when new comments are added.

Post Comment

https://electricalbaba.com/statcom-working-principle-design-and-application/ 6/7
11/28/2019 STATCOM – Working Principle, Design and Application | Electrical Concepts

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Electrical Concepts © 2019 | Theme: Optimize ↑

About Us | Contact Us | Downloads | List of downloadable generalized specification just for you. | Privacy Policy |

https://electricalbaba.com/statcom-working-principle-design-and-application/ 7/7

Potrebbero piacerti anche