CONCRETE LINE (THIN)

1) GENERAL NOTES: 8. POLYTHENE SHEETS 1000 GAUGE TO BE LAID BELOW 12. MINIMUM 6 NOS. OF CONCRETE CUBE SHALL BE TAKEN ON
EACH DAY OF CONCRETING OR FOR EACH 100 Cube.m. OF REINFORCEMENT (THK.)
1. DIMENSIONS TO BE CHECKED AS PER THE SITE CONDITION. FOUNDATIONS,TOP OF P.C.C.
CONCRETE OR AS DECIDED BY THE ENGINEER.THE CUBES REINFORCEMENT IN A
9. ALL STRUCTURES BELOW GROUND LEVEL IN CONTACT WITH SHALL BE TESTED AT A LABORATORY APPROVED BY THE DIFFERENT LAYER (THK. )
2. ALL DIMENSIONS ARE IN FEET AND INCHES ENGINEER AND IN ACCORDANCE WITH THE RECOMMENDATIONS
UNLESS OTHER WISE MENTIONED. SOIL SHALL BE PAINTED WITH TWO COATS OF BITUMEN, SECTION OF A
TO THE ENGINEER'S APPROVAL. OF IS IS 456 - 2000.
REINFORCING BAR
3. ALL LEVELS ARE IN FEET UNLESS OTHER WISE MENTIONED.
4) STEEL REINFORCEMENT NOTES: 13. ALL CONSTRUCTION JOINTS, COLUMN HEADS CONCRETE TO BE CENTER LINE
CHIPPED BEFORE NEW CONCRETING.
4. ANY DISCREPANCY IN DRAWING SHALL BE NOTIFIED TO 1. REINFORCING BARS ARE TO IS 1786-2008. DIMENSION LINE
THE STRUCTURAL CONSULTANT BEFORE STARTING THE WORK. 6) FORM WORK NOTES: CONCRETE BEAM FRAMING
2. ALL REINFORCEMENT BARS & LINKS ARE TO BE HIGH TENSILE
5. READ THE DRAWING ALONG WITH ARCHITECTURAL DRAWING INTO COLUMN WHICH EXTENDS
HAVING YIELD STRESS OF 500 N/Sq.mm. 1. STABILITY OF THE FORM WORK RESPONSIBILITY
THROUGH FLOOR
OF THE CONTRACTOR.
6. STABILITY OF FORM WORK RESPONSIBILITY OF CONTRACTOR. 3. REINFORCEMENT BARS ARE TO BE COLD BENT WITH A MAXIMUM CONCRETE BEAM FRAMING
RADIUS OF 8 TIMES DIAMETER,EXCEPT FOR STIRRUPS AND 2. BEFORE CONCRETING CHECK AND FINALIZED THE LEVEL OF INTO COLUMN WHICH STOPS
7. ALL LAPS SHALL CONFORM TO IS:456-2000. (REFER NOTE - 9) COLUMN TIES WHICH ARE TO BE 4 TIMES BAR DIAMETER. TOP OF CONCRETE WORK. AT FLOOR
BAR SHOWN BENT AT
8. NET ALLOWABLE BEARING CAPACITY CONSIDER AT 4. WHERE BARS END IN COLUMNS,BEAMS & SLABS, A HOOK OF 3. ALL SHUTTERING WORKS DONE ONLY BY THE EITHER CONCRETE RIGHT ANGLE
FOUNDING LEVEL AS 200kN/Sq.m (SAFE BEARING CAPACITY) 90° OR 180° WITH A STRAIGHT END OF 12 BAR DIAMETER AND (OR) WOOD,STEEL SURFACE. BAR WITH HOOKS
6 BAR DIAMETER RESPECTIVELY SHOULD BE PROVIDED. BAR WITH 90° BENDS
9. CONCRETE FOR R.C.C SHALL CONFIRM TO M-20,GRADE AS PER 4. PROVIDED SHUTTERING SIZES MUST REQUIRED FOR AS PER
IS: 456-2000 WITH COURSE AGGREGATE OF MAX.SIZE 20mm. 5) CONCRETE NOTES: STRUCTURAL RECOMMENDED SIZES IN DRAWING.
BAR SHOWN SEPARATE
LEVEL MARK ELEVATION
10. # DENOTES HIGH YIELD STRENGTH DEFORMED BARS Fe 500 1. MIX DESIGN :- CONCRETE MIX SHOULD BE DESIGNED TO GIVE
5. ABOVE FLOOR FINISHED LEVEL FORM WORKS THE LABORS
GRADE CONFIRM TO IS: 1786-2008. MINIMUM CUBE STRENGTH OF 25N/Sq.mm. CUBE AND MAXIMUM FREE LEVEL MARK IN PLAN
SHOULD BE PROVIDES ALL SAFETY MATERIALS.
WATER/CEMENT RATIO 0.50 BENDS NORMALLY
2) TECHNICAL NOTES: MIX SHOULD BE VERIFIED BEFORE CASTING AND APPROVED BY THE
6. THE ANY KIND OF SHUTTERING MATERIALS SHOULD BE PAINTED BENDS WITH SMALLEST
ENGINEER. DESIGN AND CONSTRUCTION TO COMPLY WITH IS 10262:1982
2.COVERS WITH OIL WITH INNER SURFACE BEFORE CONCRETING. BUNDLE WITH THREE IDENTICAL
2.1 FOR GRADE / PLINTH BEAM 25 MM (1") 2. ORDINARY PORTLAND CEMENT TO BE USED FOR ALL WORKS FOOTING REINFORCEMENT RANGE
2.2 FOR FOOTING / PILE CAP BOTTOM 50 MM (2") 7. FOUNDATION & GRADE BEAM FORM WORKS WILL BE MUST DONE
ABOVE PLINTH.UNLESS OTHERWISE SHOWN ON THE DRAWINGS. FOOTING REINFORCEMENT RANGE
2.3 FOR COLUMN 50 MM (2") ONLY BY THE TOP OF P.C.C SURFACE. CONTINUOUS
2.4 FOR FOOTING / PILE CAP SIDE 75 MM (3") 3. COARSE AND FINE AGGREGATES ARE TO BE TO I.S 383 EXTENSIONS,SECTION CUT SYMBOL
2.5 FOR ALL ROOF BEAM 25 MM (1") 8. AFTER COMPLETED THE SHUTTERING WORK PROVIDE PROPER
2.6 FOR ALL ROOF SLAB 20 MM (3/4") PROPS AND STRUT & OUTSIDE SUPPORTS.
4. WATER IS TO BE TO I.S 3025 (REFER BELOW SCHEDULE) :- IF THE ARRANGEMENT OF THE REINFORCEMENT IS
2.7 FOR R.C.C WALL (SHEAR WALL,SUMP) 40 MM (1-1/2") NOT CLEARLY SHOWN BY THE SECTION, AN
2.8 FOR PILE SIDE 50 MM (2") 9. THE CLEAR SIZE OF FORM WORKS CHECK AND CONFIRM THE ADDITIONAL SKETCH SHOWING THE REINFORCEMENT
2.9 FOR SUMP BOTTOM SLAB 40 MM (1-1/2") SI. PERMISSIBLE LIMIT, SITE ENGINEER RESPONSIBILITY. MAY BE DRAWN OUTSIDE THE SECTION.
2.10 FOR COVER SLAB 25 MM (1") NO DESCRIPTION (MAX.)
10. THE SHUTTERING DO NOT REMOVE THE BEFORE
1) ORGANIC 200 mg/l
CONCRETE RIGIDITY TIME (OR) STRUCTURAL ADVICES DAY
AFTER CASTING CONCRETE 2) INORGANIC 3000 mg/l
3.REMOVAL OF FORM WORKS (REFER TECHNICAL NOTES FIRST SHEET). ALL THE TYPES OF STIRRUPS OR TIES PRESENT
43 GRADE 53 GRADE 3) SULPHATE (as SO3) 400 mg/l SHALL BE INDICATED ON THE DRAWING. IF THE
4) CHLORIDES (AS Cl) 500 mg/l ARRANGEMENT IS COMPLICATED. IT MAY BE
3.1 FOR COLUMNS 24 HOURS 12 HOURS 11. THE STRUCTURAL CONSULTANT RECOMMEND FOR THE CLARIFIED BY THE AID OF A SKETCH IN CONNECTION
5) SUSPENDED MATTER 2000 mg/l (OR)
3.2 FOR ROOF BEAM SIDE 24 HOURS 12 HOURS FRAMED STRUCTURE CONSTRUCTION ONLY.DO NOT DO THE WITH THE NOTATION.
LOAD BEARING CONSTRUCTION.
4.FOR ROOF BEAM BOTTOM
4.1 CLEAR SPAN LESS THAN 6M : 14 DAYS 07 DAYS 7) CURING WORK NOTES: PROJECT:
4.2 CLEAR SPAN MORE THAN 6M : 21 DAYS 14 DAYS 5. PLAIN CONCRETE USED BELOW FOOTINGS SHALL BE OF MINIMUM PROPOSED RESIDENTIAL BUILDING
1. AFTER COMPLETION OF THE CONCRETING WORK CURING IS MUST @ THANJAVUR
STRENGTH AT 28 DAYS OF 10 N/Sq.mm AND MINIMUM CEMENT OF
5. DESIGNED FOR G+1 STOREYS ONLY. IN 8 HOURS.
220 Kg/Cube.m.
JOB TITLE:
2. WET COVERINGS SUCH AS WET GUNNY BAGS,
3) FOUNDATION NOTES: 6. NO CONCRETING IS ALLOWED AT A SHADE TEMPERATURE
JUTE MATTING,STRAW ETC.,ARE WRAPPED TO VERTICAL SURFACE
NOTES AND STANDARDS
EXCEEDING 37° C CONCRETE TEMPERATURE AS PLACED SHALL NOT ARCHITECT:
1. SAFE BEARING CAPACITY OF SOIL (S.B.C) IS SHOWN ON THE FOR KEEPING THE CONCRETE WET.
EXCEED 33° C, IN ALL CASES THE CONTRACTOR SHALL NOTIFY AND
FOUNDATION DRAWINGS. OBTAIN THE ENGINEER'S APPROVAL WITH REGARD TO THE TIME
3. THE CURING STRENGTH SHOULD BE ATTAIN THE CONCRETE
FOR CONCRETING.
2. AFTER EXCAVATION FOR FOUNDATIONS IMPORTED SOIL MEMBER REQUIRED FOR MINIMUM 7 DAYS AND MAXIMUM 21 DAYS.
FOR FILLS,BACKFILLS SHALL BE COMPACTED 95 % OF THE 7. NO OPENING SHALL BE MADE IN CONCRETE WORKS WITHOUT 8) DEVELOPMENT LENGTH VALUES:
MAXIMUM DRY DENSITY OF THE SOIL. WRITTEN PERMISSION OF THE ENGINEER.
DESIGNED : N.THIRUVALAR SELVAN.M.E.,
3. DEPTH OF EXCAVATION OF FOUNDATION SHOULD BE CHECKED 8. SECTION AT NECK OF COLUMN BELOW PLINTH LEVEL IS TO BE CONCRETE STEEL TENSION COMPRESSION DETAILED : N.THIRUVALAR SELVAN.M.E.,
WITH RESPECT TO THE EXISTING NEIGHBOURS,DESIGNED INCREASED ON EACH SIDE INORDER TO HAVE A CLEAR CONCRETE GRADE GRADE (EX: BEAM,etc.,) (EX: COLUMN,etc.,)
CHECKED : N.THIRUVALAR SELVAN.M.E.,
DEPTH AND APPROVED BY THE ENGINEER. COVER TO REINFORCEMENT OF MINIMUM 3" (75 mm). M 20 Fe 415 50 X d 40 X d
APPROVED : N.THIRUVALAR SELVAN.M.E.,
M 25 Fe 415 42 X d 36 X d
4. THE CONTRACTOR SHALL PROVIDE,IF NECESSARY,PROPS AND 9. VIBRATORS MUST TO BE USED FOR ALL CONCRETING WORKS. FILE NAME :
M 30 Fe 415 40 X d 34 X d
SUPPORT TO EXISTING STRUCTURES FOR SAFETY AND SCALE 1:1
ACCORDING TO THE INSTRUCTIONS OF THE ENGINEER. 10. FRESHLY PLACED CONCRETE SHALL BE PROTECTED FROM M 20 Fe 500 60 X d 48 X d SIZE A3
DATE 01.10.19
M 25 Fe 500
RAIN,DUST,AND SUN RAYS.CONCRETE TO BE CURED FOR 7 DAYS 50 X d 40 X d DWG .NO. 1 JOB .NO. 42-19 REV .NO. R0
5. GROUND WATER ENCOUNTERS REFER DEWATERING NOTES. AS REQUIRED BY THE ENGINEER USING FRESH WATER AND M 30 Fe 500 48 X d 38 X d
COVERED WITH JUTE MATTING. STRUCTRAL CONSULTANT :
THIRU ASSOCIATES
6. NO FOUNDATION SHALL PROJECT OUTSIDE THE PLOT.
SIGNATURE OF SITE ENGINEER/SITE INCHARGE:
11. ADMIXTURES TO BE USED ONLY AFTER WRITTEN APPROVAL OF
7. ALL FOUNDATIONS ARE TO REST ON P.C.C. 6" THICKNESS. (NOTE: THE NOTES COMPULSORY FOLLOW IN ALL SITE STRUCTURAL WORKS,
THE ENGINEER. USED OF ADMIXTURES CONTAINING CHLORIDE IF YOU WANT ANY CLARIFICATION CONSULT WITH STRUCTURAL OFFICE,IF YOU DO NOT
IS NOT PERMITTED. FOLLOWS TAKE YOUR OWN RISK,NOT RESPONSIBILITY IN A STRUCTURAL CONSULTANCY. Email:thiruassociatess@gmail.com