Sei sulla pagina 1di 2

Aeon7200 Anesthesia Machine

Aeon7200
Anesthesia Machine

• 7" c ol or LC D s c r een, di ffer ent par am eter s di s ti ngui s hed by c ol or s for eas y r ec ogni ti on

• N ov el des i gned v enti l ator pneum ati c s y s tem dec r eas es the c ons um pti on of Ox y gen

• Bui l t- i n “ N o W ater Vapor C oagul ati on” s am pl i ng dev i c e ens ur es Z ER O m ai ntenanc e

• F as t- r el eas e func ti on by APL v al v e i s c om par abl e to hi gh end m odel s

• Adv anc ed one button s w i tc h of m anual / auto pr ov i des c onv eni ent pneum ati c / auto c ontr ol l i ng i nter c hanges

• Opti onal AGSS dev i c e for m or e pr otec ti on

Te c h n i c a l S p e c i fi c a t i o n
Physical & Environmental Specification • Tidal Volume: 0~1600ml
• Dimensions (H×L×W ): 1386×839×628mm • Ventilation Frequency: 4~100bpm
• Weight: 85kg (basic unit) • I:E Ratio: 4:1~1:8
• Storage Temperature: -20~+55℃ • PEEP: 0~20 cmH 2O
• Working Temperature: +10~+40℃ • Inspiratory Plateau: Off, 5%~60%Ti
• Storage Humidity: ≤93% • Monitoring Display: Display: 7" color wide LCD screen
Electrical Specifications Pressure: Ppeak, Pplat, Pmean, PEEP
• Mains: 100~240V AC, 50/60Hz Volumes: MV, Vt
• Battery: 24V DC, minimum 120min Breath rate
Pneumatic Specifications Gas: FiO 2
• Gas Supply: O 2, N 2O: 0.28~0.6MPa Graph display: P-t, F-t waveforms
• Flowmeter: O : 0~1L/min; 1~10L/min
2 • Alarm: High Airway Pressure/Low Airway Pressure
N 2O: 0~1L/min; 1~10L/min High Minute Volume/Low Minute Volume
• Gas System: Oxygen supply failure alarm High FiO 2/Low FiO 2
Oxygen supply Continuous high pressure
O flush: 25~75L/min
2 Power failure
• Working Mode: Closed, Semi-closed, Semi-open O 2 Supply failure
• Driven Mode: Pneumatically driven and electronically Apnea
controlled Alarm Silence: ≤120 seconds
• Safety Valve: ≤8kPa
• Operation mode: Man. / Vent. Vaporizer
Ventilator Specification • Support 2 vaporizer (Selectatec® with interlock, optional
• Patient Type: Adult, pediatric standby vaporizer parking holder)
• Ventilation Modes: IPPV, Manual; optional: SIPPV, SIMV, SPONT • Agent Type: Halothane, Enflurane, Isoflurane,
• Setting: Touch key Sevoflurane available

Remark: Above configurations include standard and option. Please check price with your Aeonmed sales representative.

Office (Headquarters):
ADD: 11B2, Fengtai Science Park, (100070) Beijing, China
T E L : +86-10-8368 1616 FAX: +86-10-6371 8989
H t t p ://www.aeonmed.com E-mail: marketing@aeonmed.com
Information contained in this leaflet is correct at the date to publication. The policy of Beijing Aeonmed Co., Ltd. is one of the continued improvement to its products.
Because of this policy Beijing Aeonmed Co., Ltd. reserves the right to make any change, which may affect the information in this leaflet without giving prior notices.
AAM7200-1506