Sei sulla pagina 1di 1

CERTIFICATE OF CONCRETE MIX DESIGN

TO: PROJECT:

CONSTITUENT MATERIALS:
Material Type Product / Source Supplier
Ordinary Portland Cement (OPC) Binani 43 Grade/JK Laxmi 43 Grade Binani/JK
Cementitious
Pulverized Fuel Ash (PFA) NTPC Dadri / NTPC Suratgargh Various

Coarse Aggregates - 20mm MSA Chandwasi/Lakher/Delhi Road Various

Aggregates Coarse Aggregates - 10mm MSA Chandwasi/Lakher/Delhi Road Various

Fine Aggregates - R. Sand Banas Various

Chemical Admixture Superplasticizer Sikament 581 LT-10 Sika (India) Pvt Ltd

MIX DETAILS OFCONCRETE:


Project Requirement / Specifications Mix Design Details
Grade Mode Maximum Average Aggregates
Minimum
Type of Maximum Type of Total Cemen-titious Free W/C
Of Of Cementitious Size of Slump Coarse Aggregates Fine Aggregates Admixture
Cementitious Free W/C Cementitious Content Ratio
Content
Concrete Supply Material Ratio Aggregate Material MSA 20mm MSA 10mm R.Sand

Kg/Cum (mm) (mm) Kg/Cum Kg/Cum Kg/Cum Kg/Cum Kg/Cum

M-7.5 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 100+100 562 562 822 0.88 0.8% - 1.2%
M-7.5 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 100+100 552 552 842 0.88 0.8% - 1.2%
M-10 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 100+130 562 562 790 0.71 0.8% - 1.2%
M-10 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 100+130 547 547 820 0.71 0.8% - 1.2%
M-15 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 150+100 565 567 770 0.68 0.8% - 1.2%
M-15 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 150+100 562 562 789 0.68 0.8% - 1.2%
M-20 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 195+105 628 513 725 0.57 0.8% - 1.2%
M-20 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 195+105 648 432 790 0.57 0.8% - 1.2%
M-25 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 225+75 631 517 720 0.57 0.8% - 1.2%
M-25 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 225+95 648 432 775 0.53 0.8% - 1.2%
M-30 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 250+100 628 524 676 0.49 0.8% - 1.2%
M-30 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 250+100 672 448 710 0.49 0.8% - 1.2%
M-35 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 300+100 633 518 624 0.43 0.8% - 1.2%
M-35 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 300+100 678 451 657 0.43 0.8% - 1.2%
M-40 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 370+125 632 517 520 0.35 0.8% - 1.2%
M-40 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 370+125 672 450 560 0.35 0.8% - 1.2%
M-45 Manual OPC+PFA - - 20 75+/-25 OPC+PFA 415+135 632 517 473 0.32 0.8% - 1.2%
M-45 Pump OPC+PFA - - 20 100+/-25 OPC+PFA 415+135 673 445 511 0.32 0.8% - 1.2%
Note: 1. The above mix proportions are based on concrete performance observed at the time of submission of this Certificate of Mix Design.
2. The proportions & the quantities of constituent materials may change in future based on the performance, observations and/or routine revisions in mix designs.
3. The above concrete mixes are designed to confirm with acceptance criteria for compressive strength of concrete as per IS 456-2000 (Amendment no. 3, August 2007).
4. The sampling and testing of concrete specimens shall be as per guidelines of IS 4926-2003, IS 1199-1959 (Reaffirmed 1999) & IS 516-1959 (Reaffirmed 1999).
Plant-1: The methods of placing, finishing, compaction and curing of
concrete adopted at site significantly influence the quality of
Plot No.41(A),Jhotwara Ind. Area, in-situ concrete. It is, therefore, imperative that proper methods,
Near Telephone Exchange procedures and controls are exercised while handling the
Opp. State Bank of Bikaner & Jaipur. concrete at site.
Jaipur - 302 012
Shubham Jaiswal
Technical

Contact Number- 08094016560 / 73 CAUTION: Cement and concrete contain lime and other chemicals which can cause irritation, dermatitis and burning.
To avoid harm to skin, minimize contact with wet concrete and wear suitable protective clothing. Whenever contact occurs
(whether directly or through saturated clothing), wash thoroughly. In case of irritation or burns,consult a doctor immediately.