GENERAL NOTES
:250
2. DO NOT SCALE THE DRAWINGS.ONLY WRITTEN DIMENSIONS
E1
SHALL BE FOLLOWED ANY DISCREPANCIES NOTED SHALL BE
LOP 40Ø CWS HEADER PIPE BROUGHT TO THE NOTICE OF THE CONSULTANT PRIOR TO
32Ø BORE WELL
S TO OHT RUNNING ON THE
EXECUTION.
3.THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH
OTHER RELEVANT FLOOR PLAN DRAWINGS.
PARAPET WELL 4. ALL PIPE SIZES SHOWN IN THIS DRAWING ARE
OUTER DIAMETER
5. ALL 'P' TRAPS AND SANITARY FIXTURES ARE TO BE
DETERMINED AND LOCATED BY CLIENT/CONSULTANT
6. THE INSTALLATION OF ALL PIPEWORK AND FITTINGS SHALL
COMPLY WITH NATIONAL BUILDING CODE OF INDIA 2016
32Ø HOT WATER 7. ALL PIPES SHALL BE SUITABLY SUPPORTED
BY APPROVED PIPE BRACKETS.
SUPPLY PIPE 8. ALL LEVELS INDICATED IN DRAWINGS ARE MEASURED FROM
RUNNING ON THE UNDERSIDE OF PIPES TO FINISHED FLOOR LEVELS.
SLOPE 1:250
9. ALL PENETRATIONS FOR PLUMBING AND SANITARY FIXTURES
OPEN TERRACE
PARAPET WALL MUST BE PRELAID WITH PIPE SLEEVE DURING THE CASTING OF
R.C FLOOR SLAB. THE CONTRACTOR IS RESPONSIBLE FOR
CORRECT POSITIONING OF THESE PENETRATIONS.
10. ALL DIMENSIONS GIVEN ARE INDICATIVE ONLY
11. ALL BASIN OUTLETS SHALL BE FITTED WITH SUITABLE
TRAPS TO PREVENT FOUL AIR FROM ESCAPING INTO THE
32Ø SUMP TO OHT SPACE.
12. FOR LEGENDS AND MOUNTING HEIGHTS REFER RELEVANT
DRAWING .
WB FT
F
MH
CP_FITTING_MOUNTING_HEIGHT_DETAIL
RO PLANT 3000LTR C
ANGLE STOP COCK FOR
0'-8"
COLD WATER INLET TO FLUSH TANK
OPEN TERRACE ANGLE STOP COCK FOR COLD WATER
E D
D 1'-4"
INLET TO HEALTH FAUCET
LOUNGE
9'0"x15'0" E BIB COCK 2'-0"
G SHOWER ASSEMBLY WITH
PROVISION FOR 1. SHOWER ARM 6'-9"
F
F 4'-0"
2. DIVERTER / MIXER
SINTEX TANK 3. SPOUT 2'-6"
500L METRO G
ANGLE STOP COCK FOR
COLD WATER INLET TO GEYSER
6'-8"
WATER H
ANGLE STOP COCK FOR
HOT WATER FROM GEYSER
6'-8"
D C B A
3000LTR I
ANGLE STOP COCK FOR
COLD WATER INLET TO WM
3'-8"
PIPE_SCHEDULE
25Ø RO WATER SUPPLY
S.NO SYMBOL ABBR DESCRIPTION
HEADER PIPE RUNNING ON
MH
4 RW RAIN WATER
5 RO RO WATER SUPPLY
ROOF TO BE DESIGNED
5
TO LACATE THE SOLAR 3
COLLECTOR PANELS
SLO S-02
P E 1:
250
40Ø CWS HEADER PIPE
RUNNING ON THE HOT WATER
PARAPET WELL CIRCULATIONPUMP LEGEND
INDOOR GAMES ROOM
31'6"x15'6"
32Ø HOT WATER SLNO SYMBOL ABBREV DESCRIPTION
4 HF HEALTH FAUCET
5 FT FLOOR TRAP
S-01 7 63 1 2 4
6 AV ANGLE STOP COCK
7 KS KITCHEN SINK
8 BC BIB COCK
PROJECT : DRAWING STATUS : ARCHITECTS : MEP CONSULTANT : REVISION TABLE DWG. NO. : CBS/BR/PHE/103
THIS DRAWING IS THE PROPERTY OF CAPSTONE .COPYING OR REPRODUCING THE DRAWING OR IT'S CONTENT IS NOT PERMITTED WITHOUT THE COMPANY'S WRITTEN PERMISSION