Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Specifications
Components Mode Standard/Rebuild value, unit : MPa Service limit value, unit : MPa
(kgf/cm2) (psi) (bar) (kgf/cm2) (psi) (bar)
Main Main relief valve Standard 32.4 +1.5/-1 (330 +15/-10) (4693 32.4 +1.5/-2 (330 +15/-20) (4693
control +213/-142) (324 +14.7/-9.8) +213/-284) (324 +14.7/-19.6)
valve at 200 l/min (52.8 US gal/min) at 200 l/min (52.8 US gal/min)
Boost 34.3 +1.5/-1 (350 +15/-10) (4980 34.3 +1.5/-2 (350 +15/-20) (4980
+213/-142) (343 +14.7/-9.8) +213/-284) (343 +14.7/-19.6)
at 200 l/min (52.8 US gal/min) at 200 l/min (52.8 US gal/min)
Boom port relief Raise 35.8 +1.5/-1 (365 +15/-10) (5192 35.8 +1.5/-2 (365 +15/-20) (5192
valve Lower, +213/-142) (358 +14.7/-9.8) +213/-284) (358 +14.7/-19.6)
at 28 l/min (7.4 US gal/min) at 28 l/min (7.4 US gal/min)
Arm port relief valve In 35.8 +1.5/-1 (365 +15/-10) (5192 35.8 +1.5/-2 (365 +15/-20) (5192
Out +213/-142) (358 +14.7/-9.8) +213/-284) (358 +14.7/-19.6)
at 28 l/min (7.4 US gal/min) at 28 l/min (7.4 US gal/min)
Bucket port relief Curl 35.8 +1.5/-1 (365 +15/-10) (5192 35.8 +1.5/-2 (365 +15/-20) (5192
valve Dump +213/-142) (358 +14.7/-9.8) +213/-284) (358 +14.7/-19.6)
at 28 l/min (7.4 US gal/min) at 28 l/min (7.4 US gal/min)
Option - 2 stage (AL2) Standard 14.7 +1.5/-1(150 +15/-10) —
relief valve (2133 +213/-142) (147
+14.7/-9.8)
at 200 l/min (52.8 US gal/
min)
Boost 35.8 +1.5/-1 (365 +15/-10) 35.8 +1.5/-2 (365 +15/-20) (5192
(5192 +213/-142) (358 +213/-284) (358 +14.7/-19.6)
+14.7/-9.8) at 28 l/min (7.4 US gal/min)
at 28 l/min (7.4 US gal/min)
(BL2) 35.8 +1.5/-1 (365 +15/-10) (5192 35.8 +1.5/-2 (365 +15/-20) (5192
+213/-142) (358 +14.7/-9.8) +213/-284) (358 +14.7/-19.6)
at 28 l/min (7.4 US gal/min) at 28 l/min (7.4 US gal/min)
Slew motor crossover relief valve Left 26.5 +2.5/0 (270 +25/0) (3839 +356/0) 26.5 +2.5/-1 (270 +25/-10) (3839
Right (265 +25/0) +356/-142) (265 +25/-9.8)
at 200 l/min (52.8 US gal/min) at 200 l/min (52.8 US gal/min)
Track motor relief valve Left 39.2 +2.9/-1 (400 +30/-10) (5689 39.2 +2.9/-2 (400 +30/-20) (5689
Right +427/-142) (392 +29/-9.8) +427/-284) (392 +29/-19.6)
at 15 l/min (4.0 US gal/min) at 15 l/min (4.0 US gal/min)
Flow sensing valve pressure 3.2 ±0.1 (32 ±1) (455 ±14) (31 ±1)
at 30 lpm (7.9 U.S.gpm)
3.4 +0.3/0 (35 +3/0) (498 +43/0) (34
+3/0)
at 44 lpm (11.6 U.S.gpm)
Servo hydraulic pump relief valve pressure 3.9 +0.3/0(40 +3/0) (569 +43/0) (39
+2.9/0)
1. “Standard value” is the pressure value which is set in a new machine in the factory.
2. “Rebuild value” is the target pressure value which should be secured in a machine when hydraulic components are
rebuilt or remanufactured.
3. “Service limit value” is the pressure value required to obtain at least the proper basic machine performance level.
Component inspection for wear or failure, and/or pressure adjustment, should be carried out when the measured
pressure value does not meet the “Service limit value tolerances”.
4. Main and port relief pressures are easily influenced by the factors below in number 5, therefore pressure measuring
condition should be strictly kept and pressure should not be adjusted unnecessarily when a measured pressure on a
machine in the field, is within the tolerance range in the above table.
5. Main and port relief pressures which are measured in a field machine could be different from the values that are
measured in the bench tool because of the following reasons,
NOTE!
Do not set pressures at the upper limit of Service Limit Tolerance.