Sei sulla pagina 1di 2

pressure instrumentation

1.1.3.
Badotherm model BDT2 series gauges are available as 100 mm dia.
These gauges can be used for non-aggressive gaseous and liquid media.
Markets include HVAC and plumbing contractors, shipping industry etc and
are manufactured in accordance with numerous industrial specifications.

OEM 100 mm pressure gauge

mounting variations
type A bottom connection, direct mounting
type B panel mounting, clamp fixing, back connection
type C surface mounting, bottom connection BDT2
type D back connection, direct mounting
type E panel mounting, back connection
type F panel mounting, bottom connection

technical gauge specifications model BDT2


diameter connection window ranges
100 mm 1/2” BSP/NPT glass from -1/600 bar
casing tube movement dial
steel black painted copper alloy brass aluminium
bezel socket pointer accuracy
steel black painted brass fixed 1.6% FSD

options and special executions at extra cost


window plastic
dials customized – i.e., non standard ranges or logos
certificates calibration -; conformity -; material
connection METRIC; BSPT; acc JIS in various sizes
restrictor brass
red pointer on dial
connection position top or side
receiver gauge 3-15 psi; 0.2-1 bar; 0-100% lin; 0-10 sq.rt.
ranges other on request
standard packing individual boxes
soldering silver solder for steam applications type BDT2-01
max temp 200 °C

For technical data sheets and dimensional drawings please refer to our website www.badotherm.com 57
13/02/2006 rev 2-A
BDT2 - technical data sheet

pressure details
working pressure

Steady /4 x full scale value


3

Fluctuating /3 x full scale value


2

Short time see over-pressure table

pressure element over-pressure


<100 bar 100 bar max. scale in bar over-pressure at 20 °C
BDT2 Copper alloy Copper alloy -1 to 100 1,25 x full scale value
101 to 600 1,15 x full scale value

Note : only withstand for a short period of time

temperature details
temperature limitations
ambient process The variation of indication caused by the effects of tem-
perature shall not exceed :
standard -40 ºC to 60 ºC 65 ºC
±0,04 x (ambient temperature-reference temperature)%
for hard soldering -40 ºC to 60 ºC 200 ºC
of the span

design information
ingress protection design
IP 54 per EN 60 529 / IEC 529 EN 837-1

drawings

type A type D

dimensions
ns d d1 L H h weight
100 102 100 32 136 76 0,40 kg
Note : dimensions are in mm