5 User Setting Table Save

D.5 User Setting Table


No. Name User
User Setting
No. Name Setting
DC Injection Braking Time
A1-01 Access Level Selection b2-04
3 at Stop
A1-02 Control Method Selection Magnetic Flux
b2-08
A1-03 Initialize Parameters Compensation Capacity
A1-04 Password 1 Short Circuit Brake Time at
b2-12
Start
A1-05 Password 2
Short Circuit Brake Time at
A1-06 Application Preset b2-13
Stop
A1-07 FBD’s Function Selection 2 b3-01 Speed Search Selection
A2-01
Speed Search Deactivation
to User Parameters, 1 to 32 2 b3-02
Current
A2-32
Speed Search Deceleration
User Parameter Automatic b3-03
A2-33 nbnnbn Time
Selection
b3-05 Speed Search Delay Time
Frequency Reference
b1-01 Output Current 1 during
Selection 1 b3-06
Speed Search
b1-02 Run Command Selection 1
Speed Search Detection
b1-03 Stopping Method Selection b3-10
Compensation Gain
b1-04 Reverse Operation Selection
Bi-Directional Speed Search
Local/Remote Run b3-14
b1-07 Selection
Selection
Speed Search Restart
Run Command Selection b3-17
Current Level
b1-08 while in Programming
Speed Search Restart
Mode b3-18
Detection Time
b1-14 Phase Order Selection
Number of Speed Search
b1-15 Frequency Reference 2 b3-19
Restarts
b1-16 Run Command Source 2 Speed Search Method
b3-24
b1-17 Run Command at Power Up Selection
DC Injection Braking Start Speed Search Retry Interval
b2-01 b3-25
Frequency Time
DC Injection Braking Timer Function On-Delay
b2-02 b4-01
Current Time
DC Injection Braking Time/ Timer Function Off-Delay
b2-03 b4-02
DC Excitation Time at Start Time

418 OYMC TOEP C71060622-01-OY V1000 User Manual


D.5 User Setting Table

User
No. Name
No. Name User Setting
Setting
b6-01 Dwell Reference at Start
b5-01 PID Function Setting
b6-02 Dwell Time at Start
b5-02 Proportional Gain Setting (P)
b6-03 Dwell Frequency at Stop
b5-03 Integral Time Setting (I)
b6-04 Dwell Time at Stop
b5-04 Integral Limit Setting
Energy Saving Control
b5-05 Derivative Time b8-01
Selection
b5-06 PID Output Limit b8-02 Energy Saving Gain
b5-07 PID Offset Adjustment Energy Saving Control Filter
b8-03
PID Primary Delay Time Time Constant
b5-08
Constant Energy Saving Coefficient
b8-04
b5-09 PID Output Level Selection Value
b5-10 PID Output Gain Setting b8-05 Power Detection Filter Time
b5-11 PID Output Reverse Selection b8-06 Search Operation Voltage Limit
PID Feedback Reference C1-01 Acceleration Time 1
b5-12
Missing Detection Selection C1-02 Deceleration Time 1
PID Feedback Loss Detection C1-03 Acceleration Time 2
b5-13
Level
C1-04 Deceleration Time 2
PID Feedback Loss Detection
b5-14 Acceleration Time 3
Time C1-05
(Motor 2 Accel Time 1)
b5-15 PID Sleep Function Start Level
Deceleration Time 3
b5-16 PID Sleep Delay Time C1-06
(Motor 2 Decel Time 1)
b5-17 PID Accel/Decel Time Acceleration Time 4
C1-07

Standards Compliance
b5-18 PID Setpoint Selection (Motor 2 Accel Time 2)
b5-19 PID Setpoint Value Deceleration Time 4
C1-08
(Motor 2 Decel Time 2)
b5-20 PID Setpoint Scaling
C1-09 Fast-Stop Time
b5-34 PID Output Lower Limit
C1-10 Accel/Decel Time Setting Units
b5-35 PID Input Limit
Accel/Decel Time Switching
PID Feedback High Detection C1-11
b5-36 Frequency
Level

b5-37
PID Feedback High Level C2-01
S-Curve Characteristic at Accel
Start
D
Detection Time
b5-38 PID Setpoint / User Display
PID Setpoint and Display
b5-39
Digits

OYMC TOEP C71060622-01-OY V1000 User Manual 419


D.5 User Setting Table

User User
No. Name Setting No. Name Setting
S-Curve Characteristic at Accel C6-02 Carrier Frequency Selection
C2-02
End C6-03 Carrier Frequency Upper Limit
S-Curve Characteristic at Decel C6-04 Carrier Frequency Lower Limit
C2-03
Start
Carrier Frequency Proportional
S-Curve Characteristic at Decel C6-05
C2-04 Gain
End
d1-01 Frequency Reference 1
C3-01 Slip Compensation Gain
d1-02 Frequency Reference 2
Slip Compensation Primary
C3-02 d1-03 Frequency Reference 3
Delay Time
C3-03 Slip Compensation Limit d1-04 Frequency Reference 4
Slip Compensation Selection d1-05 Frequency Reference 5
C3-04
during Regeneration d1-06 Frequency Reference 6
Output Voltage Limit Operation d1-07 Frequency Reference 7
C3-05
Selection d1-08 Frequency Reference 8
C4-01 Torque Compensation Gain d1-09 Frequency Reference 9
Torque Compensation Primary d1-10 Frequency Reference 10
C4-02
Delay Time
d1-11 Frequency Reference 11
Torque Compensation at
C4-03 d1-12 Frequency Reference 12
Forward Start
Torque Compensation at d1-13 Frequency Reference 13
C4-04
Reverse Start d1-14 Frequency Reference 14
Torque Compensation Time d1-15 Frequency Reference 15
C4-05
Constant d1-16 Frequency Reference 16
Torque Compensation Primary d1-17 Jog Frequency Reference
C4-06
Delay Time 2
Frequency Reference Upper
ASR Proportional Gain 1 d2-01
C5-01 Limit
(for Simple PG V/f Control)
Frequency Reference Lower
ASR Integral Time 1 d2-02
C5-02 Limit
(for Simple PG V/f Control)
Master Speed Reference Lower
ASR Proportional Gain 2 d2-03
C5-03 Limit
(for Simple PG V/f Control)
d3-01 Jump Frequency 1
ASR Integral Time 2
C5-04 d3-02 Jump Frequency 2
(for Simple PG V/f Control)
ASR Limit (for Simple PG V/f d3-03 Jump Frequency 3
C5-05
Control) d3-04 Jump Frequency Width
C6-01 Duty Mode Selection Frequency Reference Hold
d4-01
Function Selection

420 OYMC TOEP C71060622-01-OY V1000 User Manual


D .5 U s e r S e ttin g T a b le

User User
No. Name No. Name
Setting Setting
Frequency Reference Bias Step E1-13 Base Voltage
d4-03
(Up/Down 2) E2-01 Motor Rated Current
Frequency Reference Accel/ E2-02 Motor Rated Slip
d4-04 Decel
(Up/Down 2) E2-03 Motor No-Load Current
Frequency Reference Bias E2-04 Number of Motor Poles
d4-05 Operation Mode Selection (Up/ E2-05 Motor Line-to-Line Resistance
Down 2) E2-06 Motor Leakage Inductance
Frequency Reference Bias (Up/ Motor Iron-Core Saturation
d4-06 E2-07
Down 2) Coefficient 1
Analog Frequency Reference Motor Iron-Core Saturation
d4-07 E2-08
Fluctuation Limit (Up/Down 2) Coefficient 2
Frequency Reference Bias E2-09 Motor Mechanical Loss
d4-08
Upper Limit (Up/Down 2)
Motor Iron Loss for Torque
Frequency Reference Bias E2-10
d4-09 Compensation
Lower Limit (Up/Down 2)
E2-11 Motor Rated Output
Up/Down Frequency Reference
d4-10 Motor Iron-Core Saturation
Limit Selection E2-12
Coefficient 3
d4-11 Bi-directional Output Selection
Motor 2 Control Method
d4-12 Stop Position Gain E3-01
Selection
d7-01 Offset Frequency 1
E3-04 Motor 2 Max Output Frequency
d7-02 Offset Frequency 2
E3-05 Motor 2 Max Voltage
d7-03 Offset Frequency 3
E3-06 Motor 2 Base Frequency

Standards Compliance
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection E3-07 Motor 2 Mid Output Frequency
E1-04 Max Output Frequency Motor 2 Mid Output Frequency
E3-08
E1-05 Max Voltage Voltage
E1-06 Base Frequency E3-09 Motor 2 Minimum Output Freq.
E1-07 Mid Output Frequency Motor 2 Minimum Output Freq.
E3-10
Voltage
E1-08 Mid Output Frequency Voltage
E1-09 Minimum Output Freq. E3-11 Motor 2 Mid Output Freq. 2 D
E1-10 Minimum Output Freq.Voltage Motor 2 Mid Output Freq.
E3-12
Voltage 2
E1-11 Mid Output Frequency 2
Mid Output Frequency Voltage E3-13 Motor 2 Base Voltage
E1-12
2 E4-01 Motor 2 Rated Current

OYMC TOEP C71060622-01-OY V1000 User Manual 421


D.5 User Setting Table

User User
No. Name Setting No. Name Setting
E4-02 Motor 2 Rated Slip Motor Induction Voltage
E5-24
Motor 2 Rated No-Load Constant 2 (PM motor)
E4-03
Current Operation Selection at PG Open
F1-02
E4-04 Motor 2 Motor Poles Circuit (PGO)
Motor 2 Line-to-Line Operation Selection at
E4-05 F1-03 Overspeed (OS) (for Simple PG
Resistance
V/f)
E4-06 Motor 2 Leakage Inductance
Operation Selection at
Motor 2 Motor Iron-Core F1-04 Deviation
E4-07
Saturation Coefficient 1 (for Simple PG V/f Control)
Motor 2 Motor Iron-Core Overspeed Detection Level
E4-08
Saturation Coefficient 2 F1-08
E4-09 Motor 2 Mechanical Loss (for Simple PG V/f Control)

E4-10 Motor 2 Iron Loss Overspeed Detection Delay


F1-09 Time
E4-11 Motor 2 Rated Capacity
(for Simple PG V/f Control)
Motor 2 Iron-Core Saturation
E4-12 Excessive Speed Deviation
Coefficient 3
F1-10 Detection Level (for Simple PG
Motor 2 Slip Compensation V/f Control)
E4-14
Gain
Excessive Speed Deviation
Torque Compensation Gain - F1-11 Detection Delay Time
E4-15
Motor 2 (for Simple PG V/f Control)
Motor Code Selection (PM PG Open-Circuit Detection
E5-01
motor) F1-14 Time (for Simple PG V/f
Motor Rated Capacity (PM Control)
E5-02
motor) F6-01
Motor Rated Current (PM to Range reserved
E5-03
motor) F6-41
E5-04 Motor Poles (PM motor) Communications Error
F6-01
Motor Armature Resistance operation Selection
E5-05
(PM motor) External fault from comm.
F6-02
Motor d Axis Inductance (PM option selection
E5-06
motor) External fault from comm.
F6-03
Motor q Axis Inductance (PM option operation selection
E5-07
motor) F6-04 Trace Sampling Rate
Motor Induction Voltage F6-10 CC-Link Node Address
E5-09
Constant 1 (PM motor) CC-Link communications
F6-11
speed

422 OYMC TOEP C71060622-01-OY V1000 User Manual


D.5 User Setting Table

User User
No. Name No. Name
Setting Setting
F6-14 BUS Error auto reset F7-19 Web Page Access
F6-20 DeviceNet MAC Address F7-20 Gateway selection
Device Net Communications F7-21 Communication loss time out
F6-21
Speed F7-01
F6-22 DeciveNet PCA setting to Range reserved
F6-23 DeciveNet PPA setting F7-21
DeciveNet Idle mode fault Multi-Function Digital Input
F6-24 H1-01
detection Terminal S1 Function Selection
F6-30 Profibus node address Multi-Function Digital Input
H1-02
Terminal S2 Function Selection
F6-31 Profibus Clear mode selection
Multi-Function Digital Input
F6-32 Profibus Map selections H1-03
Terminal S3 Function Selection
F6-35 CANopen Node ID selection Multi-Function Digital Input
H1-04
CANopen Communications Terminal S4 Function Selection
F6-36
speed Multi-Function Digital Input
H1-05
F6-40 CompoNet Node ID Terminal S5 Function Selection
F6-41 CompoNet Speed Multi-Function Digital Input
H1-06
F7-01 Ethernet IP Address 1 Terminal S6 Function Selection
F7-02 Ethernet IP Address 1 Terminal MA, MB and MC
H2-01
Function Selection (relay)
F7-03 Ethernet IP Address 1
Terminal P1 Function Selection
F7-04 Ethernet IP Address 1 H2-02
(open-collector)
F7-05 Subnet Mask 1 Terminal P2 Function Selection
H2-03
F7-06 Subnet Mask 2 (open-collector)

Standards Compliance
F7-07 Subnet Mask 3 Watt Hour Output Unit
H2-06
F7-08 Subnet Mask 4 Selection
F7-09 Gateway Address 1 Terminal A1 Signal Level
H3-01
Selection
F7-10 Gateway Address 2
H3-02 Terminal A1 Function Selection
F7-11 Gateway Address 3
H3-03 Terminal A1 Gain Setting
F7-12 Gateway Address 4
H3-04 Terminal A1 Bias Setting
F7-13 Dress Mode at Startup
Terminal A2 Signal Level
D
F7-14 Security password H3-09
Selection
F7-15 Duplex Mode Selection H3-10 Terminal A2 Function Selection
Communication Speed H3-11 Terminal A2 Gain Setting
F7-18
Selection

OYMC TOEP C71060622-01-OY V1000 User Manual 423


D.5 User Setting Table

User User
No. Name Setting No. Name Setting
Frequency Reference (Current) (Terminal MP) Pulse Train
H3-12 H6-06
Terminal A2 Input Bias Monitor Selection
Analog Input Filter Time H6-07 Pulse Train Monitor Scaling
H3-13
Constant Motor Overload Protection
L1-01
Multi-Function Analog 1 Selection
H4-01 (Terminal AM Monitor Motor Overload Protection
Selection) L1-02
Time
Multi-Function Analog 1 Motor Overheat Alarm
H4-02
(Terminal AM Output Gain) L1-03 Operation Selection (PTC
Multi-Function Analog 1 input)
H4-03
(Terminal AM Output Bias) Motor Overheat Fault
H5-01 Drive Node Address L1-04 Operation Selection (PTC
Communication Speed input)
H5-02
Selection Motor Temperature Input Filter
L1-05
Communication Parity Time (PTC input)
H5-03
Selection Continuous Electrothermal
L1-13
Stopping Method After Operation Selection
H5-04
Communication Error Momentary Power Loss
L2-01
Communication Fault Operation Selection
H5-05
Detection Selection Momentary Power Loss Ride-
L2-02
H5-06 Drive Transmit Wait Time Thru Time
H5-07 RTS Control Selection Momentary Power Loss
L2-03
Minimum Baseblock Time
H5-09 CE Detection Time
Momentary Power Loss
Unit Selection for MEMOBUS/ L2-04
H5-10 Voltage Recovery Ramp Time
Modbus Register 0025H
Undervoltage Detection Level
Communications ENTER L2-05
H5-11 (UV)
Function Selection
L2-06 KEB Deceleration Time
Run Command Method
H5-12 Momentary Power Loss Ride-
Selection L2-07
Thru Time
(Terminal RP) Pulse Train Input
H6-01 Minimum Frequency Gain at
Function Selection L2-08
KEB Start
H6-02 Pulse Train Input Scaling
Desired DC Bus Voltage during
H6-03 Pulse Train Input Gain L2-11
KEB
H6-04 Pulse Train Input Bias Stall Prevention Selection
L3-01
H6-05 Pulse Train Input Filter Time during Accel.

424 OYMC TOEP C71060622-01-OY V1000 User Manual


D.5 User Setting Table

User User
No. Name No. Name
Setting Setting
Stall Prevention Level during Frequency Reference at
L3-02 L4-06
Accel. Reference Loss
Stall Prevention Limit during Frequency Detection
L3-03 L4-07
Accel. Conditions
Stall Prevention Selection Number of Auto Restart
L3-04 L5-01
during Deceleration Attempts
Stall Prevention Selection Auto Restart Operation
L3-05 L5-02
during Run Selection
Stall Prevention Level during L5-04 Fault Reset Interval Time
L3-06
Run L5-05 Fault Reset Operation Selection
OV Suppression Function L6-01 Torque Detection Selection 1
L3-11
Selection
L6-02 Torque Detection Level 1
Overvoltage Suppression and
L3-17 Deceleration Stall (Desired DC L6-03 Torque Detection Time 1
Bus Voltage during Motor Stall) L6-04 Torque Detection Selection 2
Main Power Circuit Voltage L6-05 Torque Detection Level 2
L3-20
Adjustment Gain L6-06 Torque Detection Time 2
Accel/Decel Rate Calculation Mechanical Weakening
L3-21 L6-08
Gain Detection Operation
Deceleration Time at Stall Mechanical Weakening
L3-22 L6-09
Prevention during Acceleration Detection Speed Level
Automatic Reduction Selection Mechanical Weakening
L3-23 L6-10
for Stall Prevention during Run Detection Time
Motor Acceleration Time for Mechanical Weakening

Standards Compliance
L3-24 L6-11
Inertia Calculations Detection Start Time
L3-25 Load Inertia Ratio L7-01 Forward Torque Limit
Speed Agreement Detection L7-02 Reverse Torque Limit
L4-01
Level
Forward Regenerative Torque
Speed Agreement Detection L7-03
L4-02 Limit
Width
Reverse Regenerative Torque
Speed Agreement Detection L7-04
L4-03 Limit
Level (+/-)
L7-06
Torque Limit Integral Time D
Speed Agreement Detection Constant
L4-04
Width (+/-)
Torque Limit Control Method
Frequency Reference Loss L7-07
L4-05 Selection during Accel/Decel
Detection Selection

OYMC TOEP C71060622-01-OY V1000 User Manual 425


D.5 User Setting Table

User User
No. Name Setting No. Name Setting
Internal Dynamic Braking Speed Feedback Detection
n2-02
L8-01 Resistor Protection Selection Control (AFR) Time Constant
(ERF type) Speed Feedback Detection
n2-03
L8-02 Overheat Alarm Level Control (AFR) Time Constant 2
Overheat Pre-Alarm Operation High-Slip Braking Deceleration
L8-03 n3-01
Selection Frequency Width
Input Phase Loss Protection High-Slip Braking Current
L8-05 n3-02
Selection Limit
L8-07 Output Phase Loss Protection High-Slip Braking Dwell Time
n3-03
Output Ground Fault Detection at Stop
L8-09
Selection High-Slip Braking Overload
n3-04
Heatsink Cooling Fan Time
L8-10
Operation Selection Overexcitation Deceleration
n3-13
Heatsink Cooling Fan Gain
L8-11
Operation Delay Time High-Slip Suppression Current
n3-21
L8-12 Ambient Temperature Setting Level
OL2 Characteristics Selection Overexcitation Operation
L8-15 n3-23
at Low Speeds Selection
L8-18 Soft CLA Selection Line-to-Line Motor Resistance
n6-01
Online Tuning
Frequency Reduction Rate
L8-19 Speed Feedback Detection
during OH Pre-Alarm n8-45
Control Gain
Current Unbalance Detection
L8-29 Pull-In Current Compensation
(LF2) n8-47
Time Constant
L8-35 Side-by-Side Selection
n8-48 Pull-In Current
L8-38 Carrier Frequency Reduction
n8-49 Load Current
L8-41 Current Alarm Selection
Acceleration Time Pull-In
n1-01 Hunting Prevention Selection n8-51
Current
Hunting Prevention Gain Voltage Error Compensation
n1-02 n8-54
Setting Time Constant
Hunting Prevention Time
n1-03 n8-55 Load Inertia
Constant
Hunting Prevention Gain while n8-62 Output voltage limit
n1-05 Drive Mode Unit Monitor
in Reverse o1-01
Speed Feedback Detection Selection
n2-01 User Monitor Selection After
Control (AFR) Gain o1-02
Power Up

426 OYMC TOEP C71060622-01-OY V1000 User Manual


D.5 User Setting Table

User User
No. Name No. Name
Setting Setting
Digital Operator Display FBD’s Connection Parameter 1
o1-03 r1-02
Selection (lwr.)
Frequency Reference Setting FBD’s Connection Parameter 2
o1-10 r1-03
and User-Set Display (upr.)
Frequency Reference Setting / FBD’s Connection Parameter 2
o1-11 r1-04
Decimal Display (lwr.)
LOCAL/REMOTE Key FBD’s Connection Parameter 3
o2-01 r1-05
Function Selection (upr.)
o2-02 STOP Key Function Selection FBD’s Connection Parameter 3
r1-06
o2-03 User Parameter Default Value (lwr.)
o2-04 Drive Unit Selection FBD’s Connection Parameter 4
r1-07
(upr.)
Frequency Reference Setting
o2-05 FBD’s Connection Parameter 4
Method Selection r1-08
(lwr.)
Operation Selection when
o2-06 Digital Operator is FBD’s Connection Parameter 5
r1-09
Disconnected (upr.)
Motor Direction at Power Up FBD’s Connection Parameter 5
o2-07 r1-10
when Using Operator (lwr.)
o2-09 Initialization Mode FBD’s Connection Parameter 6
r1-11
(upr.)
Accumulated Operation Time
o4-01 FBD’s Connection Parameter 6
Setting r1-12
(lwr.)
Accumulated Operation Time
o4-02 FBD’s Connection Parameter 7
Selection r1-13
(upr.)

Standards Compliance
Cooling Fan Maintenance
o4-03 FBD’s Connection Parameter 7
Setting (Operation Time) r1-14
(lwr.)
o4-05 Capacitor Maintenance Setting
FBD’s Connection Parameter 8
Inrush Prevention Relay r1-15
o4-07 (upr.)
Maintenance Setting
FBD’s Connection Parameter 8
o4-09 IGBT Maintenance Setting r1-16
(lwr.)
o4-11 U2, U3 Initial Value Selection FBD’s Connection Parameter 9
r1-17
o4-12
kWH Monitor Initial Value
Selection
(upr.) D
FBD’s Connection Parameter 9
r1-18
o4-13 Motor r/min Reset (lwr.)
FBD’s Connection Parameter 1 FBD’s Connection Parameter
r1-01 r1-19
(upr.) 10 (upr.)

OYMC TOEP C71060622-01-OY V1000 User Manual 427


D.5 User Setting Table

User User
No. Name Setting No. Name Setting
FBD’s Connection Parameter FBD’s Connection Parameter
r1-20 r1-38
10 (lwr.) 19 (lwr.)
FBD’s Connection Parameter FBD’s Connection Parameter
r1-21 r1-39
11 (upr.) 20 (upr.)
FBD’s Connection Parameter FBD’s Connection Parameter
r1-22 r1-40
11 (lwr.) 20 (lwr.)
FBD’s Connection Parameter T1-00 Motor Selection 1/2
r1-23
12 (upr.) T1-01 Auto-Tuning Mode Selection
FBD’s Connection Parameter T1-02 Motor Rated Power
r1-24
12 (lwr.)
T1-03 Motor Rated Voltage
FBD’s Connection Parameter
r1-25 T1-04 Motor Rated Current
13 (upr.)
FBD’s Connection Parameter T1-05 Motor Base Frequency
r1-26
13 (lwr.) T1-06 Number of Motor Poles
FBD’s Connection Parameter T1-07 Motor Base Speed
r1-27
14 (upr.) T1-11 Motor Iron Loss
FBD’s Connection Parameter U1-01 Frequency Reference
r1-28
14 (lwr.)
U1-02 Output Frequency
FBD’s Connection Parameter
r1-29 U1-03 Output Current
15 (upr.)
FBD’s Connection Parameter U1-04 Control Mode
r1-30
15 (lwr.) U1-05 Motor Speed
FBD’s Connection Parameter U1-06 Output Voltage Reference
r1-31
16 (upr.)
FBD’s Connection Parameter U1-07 DC Bus Voltage
r1-32
16 (lwr.) U1-08 Output Power
FBD’s Connection Parameter U1-09 Torque Reference
r1-33
17 (upr.)
FBD’s Connection Parameter U1-10 Input Terminal Status
r1-34
17 (lwr.) U1-11 Output Terminal Status
FBD’s Connection Parameter
r1-35 U1-12 Drive Status
18 (upr.)
FBD’s Connection Parameter U1-13 Terminal A1 Input Voltage
r1-36
18 (lwr.) U1-14 Terminal A2 Input Voltage
FBD’s Connection Parameter Output Frequency after Soft
r1-37 U1-16
19 (upr.) Start
U1-18 OPE Fault Parameter

428 OYMC TOEP C71060622-01-OY V1000 User Manual


D.5 User Setting Table

User User
No. Name No. Name
Setting Setting
MEMOBUS/Modbus Error U3-02 2nd Most Recent Fault
U1-19
Code U3-03 3rd Most Recent Fault
U1-24 Input Pulse Monitor U3-04 4th Most Recent Fault
U1-25 Software No. (Flash) U3-05 5th Most Recent Fault
U1-26 Software No. (ROM) U3-06 6th Most Recent Fault
U2-01 Current Fault U3-07 7th Most Recent Fault
U2-02 Previous Fault U3-08 8th Most Recent Fault
Frequency Reference at U3-09 9th Most Recent Fault
U2-03
Previous Fault
U3-10 10th Most Recent Fault
Output Frequency at Previous
U2-04 Cumulative Operation Time at
Fault U3-11
Most Recent Fault
Output Current at Previous
U2-05 Cumulative Operation Time at
Fault U3-12
2nd Most Recent Fault
U2-06 Motor Speed at Previous Fault
Cumulative Operation Time at
Output Voltage at Previous U3-13
U2-07 3rd Most Recent Fault
Fault
Cumulative Operation Time at
DC Bus Voltage at Previous U3-14
U2-08 4th Most Recent Fault
Fault
Cumulative Operation Time at
U2-09 Output Power at Previous Fault U3-15
5th Most Recent Fault
Torque Reference at Previous Cumulative Operation Time at
U2-10 U3-16
Fault 6th Most Recent Fault
Input Terminal Status at Cumulative Operation Time at
U2-11 U3-17
Previous Fault 7th Most Recent Fault

Standards Compliance
Output Terminal Status at Cumulative Operation Time at
U2-12 U3-18
Previous Fault 8th Most Recent Fault
Drive Operation Status at Cumulative Operation Time at
U2-13 U3-19
Previous Fault 9th Most Recent Fault
Cumulative Operation Time at Cumulative Operation Time at
U2-14 U3-20
Previous Fault 10th Most Recent Fault
Soft Starter Speed Reference at U4-01 Accumulated Operation Time
U2-15
Previous Fault
U4-02 Number of Run Commands D
Motor q-Axis Current at
U2-16 U4-03 Cooling Fan Operation Time
Previous Fault
Motor d-Axis Current at U4-05 Capacitor Maintenance
U2-17
Previous Fault Soft Charge Circuit
U4-06
U3-01 Most Recent Fault Maintenance

OYMC TOEP C71060622-01-OY V1000 User Manual 429


D.5 User Setting Table

User User
No. Name Setting No. Name Setting
U4-07 IGBT Maintenance Frequency Reference Bias (Up/
U6-20
U4-09 LED Check Down 2)
U4-10 kWH, Lower 4 Digits U6-21 Offset Frequency
U4-11 kWH, Upper 5 Digits
U4-13 Peak Hold Current
U4-14 Peak Hold Output Frequency
Motor Overload Estimate
U4-16
(OL1)
Frequency Reference Selection
U4-18
Results
Frequency Reference from
U4-19 MEMOBUS/Modbus
Communications
U4-20 Option Frequency Reference
Run Command Selection
U4-21
Results
MEMOBUS/Modbus
U4-22
Communications Reference
U4-23 Option Card Reference
U5-01 PID Feedback
U5-02 PID Input (feedback)
U5-03 PID Output
U5-04 PID Setpoint
U5-05 PID differential feedback
U5-06 PID adjusted feedback
U6-01 Motor Secondary Current (Iq)
U6-02 Motor Excitation Current (ld)
U6-03 ASR Input
U6-04 ASR Output
U6-05 Output voltage reference (Vq)
U6-06 Output Voltage Reference (Vd)
U6-07 q-axis ACR Output
U6-08 d-Axis ACR Output

430 OYMC TOEP C71060622-01-OY V1000 User Manual