Sei sulla pagina 1di 2

EMC VNX5200

Next-generation unified storage,


optimized for virtualized applications

• Unified storage for file, block


• MCx multi-core optimization unlocks VNX Series delivers industry-leading innovation and Use storage capacity more efficiently
the power of flash in a hybrid array enterprise capabilities for file, block storage in When even a few Flash drives are combined with the
• Powerful new multi-core Intel CPUs a scalable, easy-to-use solution. This next- FAST Suite an unrivaled set of software that tiers
with 6-Gb/s SAS backend generation storage platform combines powerful and data across heterogeneous drives and boosts the
flexible hardware with advanced efficiency, most active data to cache customers receive the
• FAST Suite ensures superior management, and protection software to meet the optimal benefits of a FLASH 1st strategy. FLASH
performance at the lowest cost demanding needs of today’s enterprises. All of this 1st, available only through EMC, ensures customers
• File-level and block-level is available in a choice of systems ranging from never have to make concessions for cost or
deduplication, compression and thin affordable entry-level solutions to high- performance. Highly active data is served from up
performance, petabyte capacity configurations to 4.2 TB of Flash drives with FAST Cache, which
provisioning servicing the most demanding application dynamically absorbs unpredicted spikes in system
• Easy storage provisioning from the #1 requirements. VNX series designed to meet the high workloads. As that data ages and becomes less
provider of VMware integration* and the performance, high scalability requirements of active over time, FAST VP (Fully Automated Storage
1st storage platform to support midsize and large enterprises. Tiering for Virtual Pools) automatically tiers the
data from high-performance to high-capacity drives
Microsoft Server 2012 Hyper-V 3.0 Powerful, efficient, protect, simple in 256 MB increments, resulting in overall lower
environments A robust platform for consolidation of legacy block costs regardless of application type or data age.
• Administration simplicity with EMC storage, file servers, and direct-attached
Unisphere Management Suite application storage, VNX series enables Continuous availability
organizations to dynamically grow, share, and cost- VNX series is architected to provide five-nines
• Affordable with real-world effectively manage multi-protocol file systems and availability in mission-critical business
configurations starting at less than multi protocol block storage access. VNX operating environments. VNX availability and redundancy
10,000 euros environment enables Microsoft Windows and Linux/ features include:
UNIX clients to share files in multi-protocol - Mirrored write cache,
environments. At the same time, it supports iSCSI, - Battery backup
FC, and FCoE access for high-bandwidth and latency- - RAID protection levels 0, 1, 1/0, 3, 5, 6
sensitive block applications. Ideal for mixed - Proactive hot sparing
workloads, both physical and virtual, The VNX - Redundant data paths, power supplies, drive
series next-generation storage platform is powered connections, and storage processors all with non-
by the latest Intel Multi-Core Xeon E5-2600 series disruptive field-replacement capabilities
with a 6Gb/s SAS drive back-end and delivers more - Continuous system monitoring, call-home
firepower, greater efficiency, better protection notification, and advanced remote diagnostics
all with ease.
VNX data protection software provides the right
Flash optimized to boost performance protection for every application need:
VNX Series enabled with MCx (multi-core - Local protection is delivered with snapshots for
optimization) unleashes the power of Flash to point-in-time recovery and continuous data
address the high performance, low latency protection with RecoverPoint local replication
requirements of virtualized applications. The - Remote protection is available with the same DVR-
traditional approach to building a hybrid array like recovery with RecoverPoint Continuous Remote
entails adding flash drives to a traditional hard Replication
disk based array This approach allows for - To make application consistent replicas
consolidation of multiple workloads and deliver low controlled by the application, Replication Manager
€/GB. However, since the system was not designed and AppSync provide application protection
for flash, it limits the scalability and increases delivered as a service.
the cost. A better option is the VNX series Flash
Optimized hybrid array design. By designing the Management with Unisphere
system for Flash, bottlenecks are eliminated to Unisphere makes it easy to manage VNX systems from
deliver the highest performance and the lowest anywhere with a simple, integrated user interface
latency. Then, by adding FAST VP tiering and high for distributed storage environments. The Unisphere
capacity NL-SAS drives, you can drive down costs dashboard is a single screen for at-a-glance
for inactive data. MCx (Multi-Core RAID, Multi- management and reporting, enabling administrators
Core Cache and Multi-Core FAST Cache) distributes to gain instant and actionable knowledge about
all VNX data services across all Cores : up to 32. what’s occurring across the entire environment.
This approach delivers unprecedented application Unisphere’s single sign on automatically discovers
performance while maintaining affordable pricing. all VNX, CLARiiON, Celerra, and RecoverPoint SE
Compared to the previous generation, the VNX series installations in the environment for seamless
with MCx delivers: Up to 4X more file transactions, configuration.
Up to 4X more Oracle and SQL OLTP transactions, Up
to 4X more virtual machines, Up to 3X more
bandwidth for Oracle and SQL data warehousing.

www.bull.com
EMC VNX5200 Technical Specifications

BLOCK COMPONENTS VNX SOFTWARE


WARRANTY (Cont'd)
(Cont'd)
Min/Max. Disk Drives 4/125 Software Suites FAST; Security anddepends
Compliance;
Silver, Gold levels; on Local
Array Enclosure 3U DPE (25x2.5” SAS/Flash drives) Protection; Remote Protection;
location
Drive Enclosure Options 25 x 2.5” SAS/Flash: 2 U , 15 x 3.5” Application Protection;
SAS/Flash drives: 3 U Software Packs Total Protection, Total Efficiency
Standby Power System Battery on board Additionnal Options VNX Monitoring and reporting,
RAID Options 0/1/10/3/5/6 storage analytics, SRM, Appsync
CPU/Memory per Array 2 x Intel Xeon E5-2600 4-Core 1.2
GHz/32GB PHYSICAL SPECIFICATIONS
Max Block Flex IO Modules per Array 6 Size (HxWxD)
Embedded IO Ports per Array 2 x 4 lane SAS ports (Back end) Data Mover Enclosure 3.5 in/8.9 cm x 17.5/44.45 x
24.25/61.6
Max Total Ports per Array 28
2/4/8 Gb/s FC 24 Disk Processor Enclosure 3.5": 5.25 in (13.34) x 17.5 in
1 GBaseT iSCSI 16 (44.45) x 24.25 in (61.6); 2.5":
1 GbE iSCSI Min/Max 12 5.25 in (13.34) x 17.5 in
Max FCOE 12 (44.45) x 24.25 in (61.6)
Disk Array Enclosure 3.5": 5.25 in (13.34) x 17.6 in
6 Gb/s SAS Buses for DAE Connections 2 x 4 lane per array (44.75) x 14 in (35.56); 2.5":
3.45 in (8.76)x 17.62 in (44.75)
FILE COMPONENTS x 13 in ( 33.02)
# File X-Blades 1-2 Control Station 1.75 in/4.45x 17.5 in/44.45 x 20
# Control Stations 1x1U Server standard, 2nd x1U in/50.8
Serveur optionnal Weight
X-Blade: CPU/Memory Intel Xeon 5600/6 GB Data Mover Enclosure 52.5 lb/23.81 kg
Max File Flex IO Modules per X-Blade 3 Disk Processor Enclosure 3.5": Full: 96.4 (43.8 kg); 2.5":
Full: 73.4 (33.36)
Max Ports per X-Blade
Disk Array Enclosure 3.5": Full: 68 (30.9); 2.5": Full:
Min/Max 2/4/8 Gb/s FC 4
45 (20.45)
Max IP 8
Control Station 18 lb( 8.16)
Max 1 GBaseT 8
10 GbE iSCSI Min/Max 4
ENVIRONMENT
FUNCTIONNAL LIMITS Temperature 50–104 °F (10–40 °C),
Max Raw Capacity 500 TB Temperature Gradient 18 °F/hr (10 °C/hr)
Max SAN Hosts 1,024 Humidity 20% to 80% (non-condensing)
Max Number of Pools 15 Altitude 7,500 ft. (2,286.4 m) @ 104 °F
(40 °C) max, 10,000 ft (3,048 m)
Max Number of LUNs 1,000 @ 98.6 °F (37 °C) max
Max LUN Size 256 TB (Virtual Pool LUN)
Max File System Size 16 TB POWER
Max Usable File Capacity per X-Blade 256TB Input Voltage 100 to 240 Vac ± 10%, single-phase,
OS Support See E-Lab Navigator on Powerlink Frequency 47 to 63 Hz
Power consumption
VNX CONNECTIVITY Data Mover Enclosure 465 VA (440 W) max
Block FLEX IO Module 4 Port FC 4 Port 1 Gb/s iSCSI with Disk Processor Enclosure 3.5": 480 VA (455 W) max ;2.5":
TOE, 2 Port 1 Gb/s Opt iSCSI with 460 VA (450 W) max
TOE,2 Port 10 Gb/s iSCSI with TOE, 2 Disk Array Enclosure 3.5": 280 VA (235 W) max / 2.5 ":
Port 10 GbE FCoE, 4 port Gb/s SAS 250 VA (230 W) max
V2.0 Module
Control Station 132 VA (104 W) max
File FLEX IO Module 4 Port 1 GBase-T IP, 4 Port 1 GBaseT
and IP 1 GbE Opt IP Module, 2 Port Heat Dissipation
10 GbE Opt IP Module, 4 Port 8 Gb/s Data Mover Enclosure 1,500 Btu/hr max
Fibre Channel Disk Processor Enclosure 3.5": 1,560 Btu/hr max; 2.5": 1,540
Management LAN 2 x 10/100/1000 Copper GbE Btu/hr max
Disk Array Enclosure 3.5": 800 Btu/hr max; 2.5" : 785
Btu/hr max
DRIVES SUPPORTED Control Station 300 Btu/hr max
3.5" HDD SAS 15Krpm 300 GB, 600 GB
3.5" HDD SAS 10Krpm 300 GB, 600 GB, 900 GB, 1.2 TB
2.5" HDD SAS 10Krpm 600 GB, 900 GB, 1.2 TB
REGULATORY & SAFETY
Safety UL 60950; CSAC 22.2-60950, FN 60950,
2.5" HDD SAS 15Krpm 300 GB Manufactured under an ISO
3.5" HDD NL (Near Line) 7.2Krpm 2 TB, 3 TB, 4 TB 9000-registered quality system, ETSI
© 2019 Copyright Bull SAS All rights reserved - On-the-fly printed on 11/14/2019 9:57:54 PM

3.5" SDD SAS 100 GB, 200 GB, 400 GB, 800 GB EN 300 386
2.5" SDD SAS 100 GB, 200 GB, 400 GB, 800 GB Electromagnetic Compatibility (EMC) FCC Class A EN55022 Class A, CE Mark
VCCI Class A (for Japan), ICES-003
Class A (for Canada) AS/NZS 3548
VNX SOFTWARE Class A (for Australia/New
Management Software Unisphere for Block, File or Unified Zealand), EN55024 Immunity, ITE
BSMI Class A (for Taiwan)
Supported Protocols CIFS, NFS, pNFS, MPFS, FC, FCoE,
iSCSI included
Base Software Per TB charge, drive type dependent, WARRANTY
includes: All Protocols (See Standard warranty World Wide; 3 years Hardware
above), Thin Provisioning, Block Support, 9x5, Next Business Day,
Deduplication and compression, File parts only, Customer in charge of
Deduplication and Compression, SAN replacement for some components
Copy Extended Warranty Bull’s GlobalCare offer: Bronze,

Bull SAS - RCS Versailles B 642 058 739 - All trademarks mentioned herein are the property of their respective owners. Bull reserves the right to modify this document at any time without
prior notice. Some offers or parts of offers described in this document may not be available locally. Please contact your local Bull correspondent to know which offers are available in your
country. This document has no contractual significance.

Bull SAS - rue Jean Jaurès - 78340 Les Clayes-sous-Bois – France


UK : Maxted Road, Hemel Hempstead, Herts HP2 7DZ
USA : 285 Billerica Road, Chelmsford, MA 01824

www.bull.com

Potrebbero piacerti anche