Sei sulla pagina 1di 2

Integra-TR Wireless Modem Power Requirements Integra-TR also supports CTS flow control for cases where Table

Integra-TR also supports CTS flow control for cases where Table 3: Integra -TR Accessories
Quick Reference the terminal rate exceeds the network rate.
Accessory DRL Part #
Copyright © Dataradio 1999 Integra-TR requires a regulated power source of 13.3VDC
Field Programming Software kit (soft- 250-4008-001
nominal (10 to 16 VDC maximum), negative ground with a DE-9M ware and setup/data cable)
General 3.0A rating. 1 Technical Manual 001-4008-102
RXD 2 SMA Male to BNC Female adapter 023-3410-098
Integra-TR is a high-speed transparent wireless modem +13.3 VDC (1) (2) GND TXD 3 cable
designed specifically to fit the needs of SCADA, telemetry (red) (black) GND 4 Cooling Fan-Factory option (for high Catalog number plus
and control applications. It has: 5 duty-cycle transmit applications) “F” suffix
6
• Selectable network speeds of 4800 and 9600 b/s for (4) Analog in 2 /
Analog in 1 (3) 7 LED Indicators
half channel units as well as 4800, 9600 and 19.200 b/s (green) RX-TP (white)
8
for full channel units. 9
Fig. 1 POWER / ANALOG CONNECTOR Integra-TR has four two-color LED indicators. Functions
• Backward compatible with the Integra-T for bit rate of
Fig. 3 3-Wire Connection Block Diagram are shown in the following table:
4800 and 9600 b/s (full channel units only)
• One front panel COM port for connection to DTE,
Com Port Green Normal operation
Setup Port Flash Sleep mode (flashed during wake-
speeds 300 - 19200 bauds. Run/PWR
Integra-TR is equipped with a RS-232 Com Port configured Green up)
• One front panel Setup port, for configuration and Flash red Setup mode or loading new
as DCE. It should be connected, using a suitable shielded The Setup port uses a DE-9 female connector configured as
diagnostics (speed fixed to 9600 baud, 8 bit, no parity, & green application or new bootloader
cable, to equipment configured as DTE. Connection to DCE. The signals are:
1 stop bit). Flash red Firmware error*
DCE, such as another modem, requires a DCE crossover
• Rear panel mounted dual-function connector for power Table 2: DE-9 Connector Signals Red CPU or PROM failure*
cable. See the Integra-TR technical manual for information. CS/SYN
and analog inputs. Off No RF Carrier
In RTS-CTS mode, Integra-TR expects the DTE to assert Pin Name Function Green Receive carrier present
• Built-in 5-watt transceiver, operating in the VHF, UHF
RTS prior to sending data and to release it to receive. Most 1 DCD Tied directly to DTR Red (Reserved)
or 900 MHz communications bands. Half-duplex or
PC communications software does not switch RTS; this will 2 RXD Data from Integra to setup PC Rx/Tx Off Idle
simplex operation (25 or 12.5 kHz channel spacing).
result in the unit constantly transmitting. 3 TXD Data from setup PC to Integra Green Receiving network data
• Fully transparent operation with error-free data
4 DTR Tied directly to DCD Yellow Synthesizer unlocked
delivery.
For proper operation, DTE must honor CTS. 5 GND Signal and chassis ground Red Transmitter is on
• Allows transmission of “break” characters. RD/TD Off Idle
• DOX (Data Operating Transmission) or RTS mode. 6 DSR Output: Always positive (asserted)
7 RTS Tied to CTS. Also monitored to Green Rx data outgoing from RS-232 port
• Stations may be set as “master” or “remote” to prevent Table 1: DE-9 Pin Assignment Red Tx data incoming at RS-232 port
“wake-up” unit from sleep mode
remote stations from hearing each other simplex RF Pin Name Function 8 CTS Tied to RTS * Contact Technical Service.
configuration 1 DCD Output: Always asserted or asserted 9 RI Not used, reserved
• Full local and remote diagnostics. when RX data available (selectable Operation
• Two 8-bit analog inputs (0 - 10V). via Field Programming Software) The Setup port uses a proprietary communications protocol
• Low power consumption modes: “sleep” and 2 RXD Output: Data from Integra to DTE designed to work with the Integra Field Programming Integra-TR is designed for fully transparent operation. This
“suspend” modes (nominal 7mA). 3 TXD Input: Data from DTE to Integra Software. It is also designed to provide numeric diagnostics means that all binary values are transmitted as data, with
• “12 VDC, negative ground, device. 4 DTR Input: Ignored information when connected to a PC terminal emulator. For minimum time delays, and without regard to their binary
5 GND Signal and chassis ground format, see the technical manual. value. “Break” signals can also be transmitted.
There are no external switches or adjustments; operating 6 DSR Output: Always positive (asserted)
7 RTS Input: Used as a “begin transmission” Unlike most transparent radiometers, Integra-TR eliminates
parameters are set using the Field Programming Software. Configuration
signal in TRS mode. Will “wake-up” “bit dribble” and allows DOX operation. A CRC-16 error
Integra firmware resides in flash EPROM and is designed
unit in sleep mode. check is used so that faulty data will not be delivered.
to allow field upgrades. Operating characteristics of Integra-TR are configured by
8 CTS Output: Used for handshaking in RTS
mode; used for flow control in DOX means of the Field Programming Software program. The Operating Modes
Installation programming software permits both local and remote
mode.
RTS mode: TRS/CTS delay in 4ms. diagnostics. These are available from your sales Integra-TR has two operating modes, for its COM port:
Integra-TR is not hermetically sealed and should be DOX mode: CTS always asserted, representative. Integra-TR requires the use of the Field (selectable via the Field Programming Software)
mounted in a suitable enclosure where dust and/or a except when data overflow is Programming Software for both configuration and DOX mode: The RS-232 port is monitored for incoming
corrosive atmosphere are anticipated. detected. adjustments. data. Upon receipt of the first data byte, the transmitter is
9 RI Not used, reserved turned on. The RTS signal is ignored (note: RTS may still be
Antenna used as a wake-up signal for a unit that is asleep).
3-Wire connection (DOX) RTS mode: The RTS signal is monitored for a low-to-high
Integra-TR is designed for use over distances up to 30 miles transition. This transition causes Integra-TR to turn on its
(50 km) depending on terrain and antenna system. The transmitter. CTS is raised 4 ms later to accommodate DTE
proper antenna, designed for the frequency of operation, is For DTE that lack RTS control, Integra-TR can operate in
DOX mode (Data Operated Transmit) with only Transmit that requires a CTS transition before it can send data. The
to be mounted at an effective elevation, have an impedance transmission will continue until RTS is dropped, or until the
of 50 ohms and have a SMA type connector. Data, Receive Data and Ground (“3-wire interface”).
Tx time out expires.
CTS is used as a handshaking/flow control signal in both Notice/Warning importante no uso restritivo estados de Offline diagnostics are sent upon receipt of a command Technical Service
modes. If Integra's buffers fill, CTS will be dropped as a todo o membro do EU e do EFTA: Este dispositivo é um from the Integra-TR Field Programming Software normally
signal to the DTE to stop sending data. This condition is transmissor de rádio dos dados de VHF/UHF pretendido when the host application is stopped or taken offline. Since Technical Service hours are 7:30 AM to 4:30PM, Central
most likely when the Com Port speed exceeds the radio para o uso indoor e ao ar livre. A operação deste diagnostics transmissions are not under the control of the Time, Monday through Friday.
network speed. In such cases, adjust the DTE baud rate so dispositivo é sujeita à licença do end-user. O usuário da SCADA user protocol, temporary network disruption will
that Integra's buffers will not fill. extremidade é recomendado fortemente contatar as occur if both are attempted simultaneously. DATARADIO COR Ltd.
autoridades locais da gerência da freqüência para obter Technical Service
Integra-TR CE tal licença do end-user de acordo com legislações e Online diagnostics 299 Johnson Avenue, P.O. Box 1733
alocamentos locais da freqüência. O fabricante das Online diagnostics, if enabled, are included with every data Waseca, MN 56093-0833
tomadas nenhuma responsabilidade para algum uso transmission. Online diagnostics do not interfere with
desautorizado deste dispositivo. normal network operation. The following information is Phone: 800 992-7774 and 1 507 833-8819
gathered and delivered via the Setup port: Fax: 1 507 833-6748
Advertencia/Noticia: Importante uso restrictivo en E-mail address: support@dataradio-cor. com
Estados miembros de toda la Unión Europea y de Aelc: Unit's “short ID”
Important Notice/Warning on restrictive use in all EU Este equipo es un radio transmisor de datos en las bandas Inside case temperature: degrees C
and EFTA member states: de VHF y UHF previsto para uso en interiores y Supply voltage (B+): in volts
exteriores. La operación de este equipo es conforme a Local received signal strength: in dBm
Important Notice/Warning on restrictive use in all EU licencia obtenida por el usuario final. Se aconseja al Remote received signal strength: in dBm
and EFTA member states: usurario final que entre en contacto con las autoridades Forward power: in watts
This device is a VHF/UHF Radio data transmitter intended locales que aprueban el uso de frecuencias, para obtener Reverse power: good / poor
for indoor and outdoor use. Operation of this device is su propia asignación de frecuencia de acuerdo a la Receive quality: based on last 15 data blocks received.
subject to end-user licence. The end user is strongly legislacion de cada pais. El fabricante no se hace
advised to contact the local frequency management responsable del uso de los equipos sin la aprobación de Offline diagnostics
authorities to obtain such an end-user license according to frecuencia por las autoridades locales. Offline diagnostics are returned in response to a specific
local legislations and frequency allocations. The request to a particular station. Requests are issued using the
manufacturer takes no responsibility for any unauthorized Wichtige Information/Warnung hinsichtlich Gebrauch in Integra-TR Field Programming Software, either locally or
use of this device. allen EU- und EFTA-Mitgliederstaaten: remotely from another station. This may cause slight
Dieses Gerät ist ein VHF/UHF Daten – Funkgerät, daß temporary network disruption. We recommend the
Avis important/Avertissement au sujet de restrictions sowohl innen als auch im Freien betrieben werden kann. application be taken off line.
d’utilisation applicables à l’intérieur d’un pays membre de Die Inbetriebnahme dieses Gerätes ist abhängig von The diagnostic information available is similar to that
l’UE ou de l’AELE : einer Nutzerlizenz. Wir empfehlen dem Gerätebetreiber available from online diagnostics with the following
Cet appareil est un émetteur radio opérant en VHF/UHF, sich mit den zuständigen Frequenz – additions:
d’usage intérieur ou extérieur, utilisé pour la transmission Regulierungsbehörden in Verbindung zu setzen, um die Demodulated signal voltage: peak-to-peak
de données. L’opération de cet appareil est assujettie aux entsprechenden Lizenzen, gemäß gültiger Gesetzgebung, Analog 1 input voltage: 0 - 10 VDC
zu beantragen. Der Hersteller dieses Daten –
termes et conditions de la licence émise à l’utilisateur Analog 2 input voltage: 0 - 10 VDC
Funkgerätes kann keine Haftung für nicht
final. Il est fortement conseillé à l’utilisateur final de Reverse power: in watts (rather than a good/poor flag).
ordnungsgemäßen (gesetzeskonformen) Betrieb des
contacter les autorités locales légalement responsables de Gerätes übernehmen.
la gestion et de l’allocation des fréquences radios et Note: Analog 1 and 2 have 8 bits of resolution.
d’obtenir auprès d’eux toute licence d’opération requise.
Le manufacturier n’assume aucune responsabilité pour Diagnostics Servicing
l’usage non réglementaire de cet appareil.
Online diagnostics may be included as part of an extended This product is not field-serviceable, except by the
header at the beginning of each transmission. It may be replacement of complete units. Specialized equipment and
Avvertenza importante per l'uso limitato ai paesi della
enabled or disabled on a per-unit basis without affecting training is required to repair logic boards and radio modules.
Comunita' Europea ed EFTA. inter-communication. Reception of online diagnostics is
Questo dispositivo e' un trasmettitore radiofonico di dati di Contact Technical Service for service information.
always enabled.
VHF/UHF per uso interno ed esterno. Bisogna avere una Enabling this option adds about 2.5 ms delay at 19.200 b/s,
licenza per ultilizzare questo dispositivo. Consigliamo for- 5 ms at 9600 b/s or 10 ms at 4800 b/s to each transmission,
temente a chi usera' questo trasmettitore di contattare le but has no other effect on network operation. Online
autorita' locali che amministrano la gestione delle fre- diagnostics for all audible stations is delivered out at the
quenze per ottenere un'autorizzazione che sia conforme Setup Port. An ASCII diagnostic output is also available.
alle leggi locali, e, con questa ottenere l'assegnamento Diagnostic information is normally collected at the master
della frequenza. Il fornitore di questo dispositivo non e' station.
responsabile per l'uso non autorizzato.
© 1999 DATARADIO Inc. 6-01 Printed in U.S.A. Part No. 004-4008-001