T E L E M E D I C I N E P H A R M A C Y • P O C

S E L F T E S T I N G L A B O R A T O R Y
Clinical chemistry analyzers
and reagents for laboratories needs.

BIOCHEMICAL SYSTEMS INTERNATIONAL,


as a diagnostic device manufacturer, has been
researching for 25 years, with the aim of
developing and producing innovative solutions
for the diagnostic laboratory.
The result is a unique analyzer, COMBI,
that integrates new working concepts in a
compact design.

COMBI has been developed to be easily


integrated in all types of laboratories and
hospitals for routine, emergency as well as
specific analysis.
COMBI
is a multifunction random access bench top analyzer combining
clinical chemistry, coagulation and immunochemistry.
Arezzo, Italy

COMBI is dedicated
to small & mid size
laboratories, doctor
office, hospitals, clinics.
COMPACT RANDOM ACCESS ANALYZER

LOW REAGENT CONSUMPTION

THROUGHPUT UP TO 200 TESTS/HOUR

TRUSTED PERFORMANCE

BSI LABORATORY

UP TO 4 REAGENTS HANDLING
4

24 MINUTES OF REACTION TIME


24’

COMBINATION OF COAGULATION & CLINICAL CHEMISTRY TESTS

COMPACTNESS, VERTICAL DESIGN

USER FRIENDLY SOFTWARE

LOW WATER CONSUMPTION

TOUCH SCREEN
TEST LIST

CLINICAL CHEMISTRY

ALBUMIN CK-MB LIPASE


ALKALINE PHOSPHATASE CK-NAC MAGNESIUM
AMYLASE CREATININE PHOSPHORUS
BILIRUBIN DIRECT GAMMA GT TOTAL PROTEINS
BILIRUBIN TOTAL GLUCOSE TRIGLYCERIDES
CALCIUM GOT UREA
CHLORIDE GPT URIC ACID
CHOLESTEROL HEMOGLOBIN A1c (HbA1c) ZINC
CHOLESTEROL HDL DIRECT HOMOCYSTEINE (HCY)
CHOLESTEROL LDL (calculated) IRON
CHOLINESTERASE LDH

IMMUNOCHEMISTRY

ANTI- STREPTOLYSIN O (ASO) IMMUNOGLOBULIN M (IGM)


C-REACTIVE PROTEIN (CRP) TRANSFERRIN
IMMUNOGLOBULIN A (IGA) RHEUMATOID FACTOR (RF)
IMMUNOGLOBULIN G (IGG)

COAGULATION

PROTHROMBIN TIME (PT)


PARTIAL THROMBOPLASTIN TIME (PTT)
FIBRINOGEN
01 02

04 05

01 Optical carousel 03 Removable sample tray up


with 45 reusable to 48 sample positions.
Bionex ® Removable reagent tray
cuvettes. with 64 reagent positions.

02 Cuvette washing 04 Positive


system integrated, sample
10 (5x2) steps. identification
by barcode.
SYSTEM SPECIFICATIONS
 HROUGHPUT UP TO 200
T
TESTS/HOUR
03  ONTINUOUS SAMPLE
C
LOADING
 AMPLE TYPE PRIMARY
S
TUBES OR PEDIATRIC CUPS
 OOLING REAGENT
C
SYSTEM BY A DEDICATED
SWITCH
 UN TIME OPTICAL
R
CUVETTE QUALITY CHECK
 AMPLES AUTOMATIC
S
06
DILUTION PRE, POST AND
RE-RUN
 VAILABLE BOTH AS OPEN
A
AND CLOSED SYSTEM
05 Needle capacitive  ESS THAN 1 LITER/HOUR
L
liquid level
detector with WATER CONSUMPTION
impact sensor.
 EVEL SENSORS FOR
L
WASH AND WASTE TANKS

06 Touch screen  UALITY CONTROL


Q
user friendly PROGRAM
software.
LOW MAINTENANCE
SOFTWARE FEATURES
Graphical user interface for
convenient operation.
C ontinuous loading of samples SAMPLE
and reagents refilling. ENTRY

Random access and stat, re-run


sample worklists.
Walk away capability with real
time alarm.
Unlimited patients, results and STATUS
test database. MONITOR

Multi language software.


L evey-Jennings plots and
Westgard multi rules.
Up to 3 qc levels per test, qc
monitor and reports. ABSORBANCE
CURVE
Method statistics: including test
counter, cv%, mean, graphical
trend analysis.
Active reagent monitoring
(volumes, available tests,
calibration, qc status). RESULTS
Automatic pre and post dilution.
Up to 8 calibrators per method.
Dynamic autodilution of
standards.
Bi-directional LIS/HIS. SOFTWARE
Using the COMBI software,
Positive identification of samples operators manage all the needs of
with internal barcode reader. today laboratories in flexible and
efficient way.
Printing on any Windows® Unique software that combines the
compatible printer in most usability of Microsoft Windows®
common formats. with the advantage of touch screen
interface, manages automatically
Customizable profiles to easy
the clinical chemistry, coagulation
manage the workload.
and immunochemistry test
Touch screen software speeds up procedures giving the operator
routine operations. a new experience on routine work.
TECHNICAL FEATURES

MODE O PTICAL SYSTEM



- Random access, stat, continuous - Spectral range: 290-1100 nm
sample loading - I nterferential filters wavelengths:
340, 405, 505, 546, 578, 630, 660,
ANALYSIS 700 nm
- T hroughput up to 200 tests/hour -P  hotometric linearity: 0-2.5 od;
-E  nd point, differential, fixed time, resolution 0.0001 od
kinetic -O  ptical source: tungsten halogen
- C alibration up to 8 points for each lamp (long life, auto-power off)
analysis (linear, spline, logit-log, etc.) -O  ptical range: 0-5 od (10 mm
-C  oagulation mode with 0.250 conversion)
seconds resolution
-R  eagent handling: automatic up WASHING

to 4 reagents up to 24 minutes of - 10 steps (5x2) cuvette wash station
cuvette reaction time - P ipetting needle auto-washed
internally and externally
SAMPLE - Water consumption: less than 1 l/h
- Removable tray - L evel sensor on waste and wash
-U  p to 48 samples on board in tanks
primary tubes 75/100 mm,
or pediatric cups 1.5 ml USER INTERFACE
- Sample volume: 1.5 – 100 μl - E xternal computer required,
-B  arcode scan during sample Windows® based
processing -C  ommunication: usb port or serial
- Automatic pre and post dilution rs232
- Test profiles and replicates -V  arious print-out format for patient
results
REAGENT - Software usable for touch screen
- Removable tray - Multi language software
- Up to 64 reagents on board
-R eagent bottles available in ENVIRONMENT CONDITIONS
different volumes: 13 ml, 25 ml and - 15-30°C; humidity 30-80% non-
40 ml condensing
-R  eagent tray cooling for all
positions POWER
- Reagent volume: 2-350 μl - A C 110/115/230 VOLT (50/60 HZ)
-B  arcode scan for reagent
identification DIMENSIONS
- ( WXDXH) 54X44X64 cm
REACTION
- Reaction volume: 180-350 μl WEIGHT
- 6 mm optical path cuvette - 37 Kg
- 45 bionex ® reusable cuvettes
- Reaction temperature 37°c OPTIONS ( ON REQUEST)
- ISE MODULE
P IPETTING SYSTEM
 - EXTERNAL PRINTER
-C eramic piston diluter, maintenance - TOUCH PANEL PC
free - UPS
- Needle impact detection
-N eedle capacitive liquid level
detection
BRO.COMBI.ING.ED2018OCT

BIOCHEMICAL SYSTEMS INTERNATIONAL S.P.A.


Headquarter
Loc. Palazzo del Pero, 23 - 52100 Arezzo (AR) - Italia
Tel. +39 0575 984164 - Fax +39 0575 984238

Instrument Division
Via B. Buozzi, 253 - 50013 Campi Bisenzio (FI) - Italia
Tel. +39 055 8963140 - Fax +39 055 8997086
www.biosys.it - biosys@biosys.it