Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
uk
58 Crossway, Welwyn Garden City, Herts, AL8 7 E E Fax: 017 0 7 692006 Email: sia@ sts-se.co.uk
STRUCTURAL CALCULATIONS
Site: 12 Amberley House, Warwick Road, EN5 5EG
Section: UB 152x89x16
Page 2/4
STS Structural Engineering
Tel: 01707 695466 Fax: 01707 692006, www.sts-se.co.uk, 58 Crossway, Welwyn Garden City, Herts AL8 7EE
Site: 12 Amberley House, Warwick Road, EN5 5EG Made By: MN
Job: Structural Opening Checked: SS
Job No. 1609-997 Page:
Beam: MKL01 - New Doorway Lintel Beam
Section Classification
Steel is Grade: 43
The maximum thickness of steel: 7.70 mm
Table 9 Therefore, py = 275 N/mm2
Flange b/T = 5.76
Web d/t = 27.1
Section type: UB
ε= 1
Table 11 Section is: Plastic - Class 1
Page 3/4
STS Structural Engineering
Tel: 01707 695466 Fax: 01707 692006, www.sts-se.co.uk, 58 Crossway, Welwyn Garden City, Herts AL8 7EE
Site: 12 Amberley House, Warwick Road, EN5 5EG Made By: MN
Job: Structural Opening Checked: SS
Job No. 1609-997 Page:
Beam: MKL01 - New Doorway Lintel Beam
Cl 4.3 Lateral Torsional Buckling
Table 13 Effective Length Le/L ratio = 1.30
Total Length of the beam L = 2.70 m
Effective Length Le = 3.51 m
Max. Applied Bending Moment Mx = 12.2 kNm
Table 18 Equivalent uniform moment factor mLT = 0.93
4.3.6.7 Slenderness λ = 167.1
4.3.6.8 Torsional Index x = D/t = 19.8
4.3.6.7 Slenderness factor v = 0.684
blue book Buckling Parameter u = 0.89
4.3.6.9 Ratio βW = 1.000
4.3.6.7 Equivalent Slenderness λLT = uvλ√βW = 101.77
B.2.2 Limiting Equivalent slenderness λL0 = 34.31
B.2.2 Robertson Constant αLT = 7.0
B.2.2 Perry Factor ηLT = 0.472
2
B.2.1 Euler Strength pε = 195 N/mm
ΦLT =
2
B.2.1 281 N/mm
2
B.2.1 Bending Strength pb = 121.91 N/mm
4.3.6.1 Equivalent slenderness is more than Limiting eq. sl. -
Use pb for Lat. Tor. Buckling
4.3.6.4 Buckling Resistance moment Mb = 15 kNm
Efficiency Ratio 0.759
Section passes lateral torsional
buckling check
Page 4/4