Sei sulla pagina 1di 1

PROTECTION RELAY A.

Current Operated (DI) Relays

Designation QLM QRSI QE QF QLA MCR

Technical Specifications
Operating Range 3.75-9.9A 3.75-9.9A 3.75-9.9A 3.75-9.9A 5±5%A 2.1-7.5A
AC, 50Hz AC, 50Hz AC, 50Hz DC AC, 50Hz AC, 50Hz

No. of contacts customised 2 NC/2NO/ 2 NC/2NO/ 2 NC/2NO/ 2 NC/2NO/ 2 NC/2NO/ 2 NC/2NO/


1NC+ 1NO 1NC+ 1NO 1NC+ 1NO 1NC+ 1NO 1NC+ 1NO 1NC+ 1NO
Salient Features
Coil resistance at 20°C 30m Ω ±8% 30m Ω ±8% 30m Ω ±8% 30m Ω ±8% 30m Ω ±8% 89.5m Ω ±8%
• Plug-in design for simple mounting and Pick-up time <70msec <70msec <70msec <70msec <70msec <70msec
easy checking.
Dropout time <60msec <60msec <60msec <60msec <60msec <60msec
• Minimum maintenance.
Contact Making 2A 2A 2A 2A 2A 2A
• Quick response time. rating current at
110v (DC)
• Compact and lightweight design.
Breaking 2A 2A 2A 2A 2A 2A
• Rugged construction with proven Current at
performance under varying condition. 220v (AC)

Dielectric Contact to 2.0kV 2.0kV 2.0kV 2.0kV 2.0kV 2.0kV


• Adjustable tripping current/voltage value rating earth
as per requirement.
Coil to 2.0kV 2.0kV 2.0kV 2.0kV 2.0kV 2.0kV
• High insulation level. contact
and earth
• High repeatability at the set value.
Adjacent 1.5kV 1.5kV 1.5kV 1.5kV 1.5kV 1.5kV
• High mechanical and electrical Contact
endurance. Weight (approx.) 1.2kg 1.2kg 1.2kg 1.2kg 1.2kg 1.2kg

Types
Current Operated (DI) Relays: QLM, QRSI,
QE, QF, QLA and MCR relays. B. Voltage Operated (DU) Relays

Voltage Operated (DU) Relays: QOP, QOA Designation QOP QOA Q30 QSIT
QSIT and Q30 relays.
Operating Range 70-125 V DC 70-125 V DC 290-500 V AC, 50Hz 70-125VDL

Applications No. of contacts customised 2 NC/2 NO/ 2 NC/2 NO/ 2 NC/2 NO/ 2NC+2NO
1 NC+1 NO 1 NC+1 NO 1 NC+1 NO
The relays are designed for protecting Coil resistance at 20°C 1800 Ω ±8% 1800 Ω ±8% 1180 Ω ±8% 1800 Ω ±8%
electric locomotive equipments & circuits:
Pick-up time <70msec <70msec <70msec <70msec
• Main transformer against overloading. Dropout time <60msec <60msec <60msec <60msec
• Excitation windings of traction motors and Contract Making current 2A 2A 2A 2A
rheostatic braking resistance against over rating at 110v (DC)
current. Breaking current 2A 2A 2A 2A
• Auxiliary equipments against overloading. at 220v (AC)
Dielectric test Contact to earth 2.0 kV 2.0 kV 2.0 kV 2.0kV
• Silicon Rectifier against overloading.
Coil to contact 4.8 kV 4.8 kV 3.0 kV 3.0 kV
• Main power circuit and auxiliary circuit and earth
against earth fault. Adjacent contact 1.5 kV 1.5 kV 1.5 kV 1.5 kV
Protection Relays suitable for electric traction
• Locomotive's electrical equipment against Weight (approx.) 1.2 kg 1.2 kg 1.2 kg 1.3 kV
drop of OHE voltage below minimum vehicles. Designed to withstand extremes of
value. mechanical and thermal stresses, the product has a
proven track record for reliability.

Potrebbero piacerti anche