Surge protection for instrumentation, control and automation circuits

VARITECTOR SPC VARITECTOR SSC EMC Set

Pluggable surge protection With a width of 6 mm in a compact


terminal format
For error detection and error
messages as well as for monitoring The VARITECTOR SSC family of surge For precise identification, all
instrumentation, control and protection devices for I&C circuits was VARITECTOR products are equipped
automation circuits, Weidmüller developed with compact terminal-like with large-scale marking capabilities:
developed the VARITECTOR SPC, dimensions (only 6.2 mm wide). Connections for equipment or
its new families of surge protection individual devices are labelled and the
devices. The VARITECTOR SPC, The VARITECTOR SSC family comprises various voltage levels are marked by a
the pluggable surge protection, is over 100 devices, thus being able colour code. Due to this, components
characterised by highest protective to offer a fitting solution for any kind can be quickly identified in a switching
functions with compact dimensions. of surge protection. This protection cabinet, thus simplifying both service
With the VARITECTOR SPC R modules, comprises current loops and binary and commissioning.
error detection and error messages signals for 5 V, 12 V, 24 V, 48 V and
are realized by internal monitoring. Up 60 V. The terminals are equipped with All VARITECTOR SPC and SSC products
to ten surge protection modules can complete integrated surge protection were tested in accordance with the
be combined to transmit a message units or individual components such as latest standards (IEC 61643-21): In
to the evaluation unit VARITECTOR varistors. classes D1, C1 and C2, they fulfil the
SPC Control Unit. The advantage of safe short-circuit mode when units fail
all VARITECTOR SPC modules is that Using a slotted-head Torx screw with to overload of required.
they are designed to be removed or a locking torque of 0.8 to 1.0 Nm,
exchanged during running operation conductors ranging from 0.5 to 6 mm2 The EMC set offers additional
- without interrupting the measuring are connected providing proection convenience for connections with
circuit. against vibration . shielded cables. The EMC set consists
of the EMC connector, i.e. the shield
The V-TEST unit is used for testing the The safe discharge of surges up to 20 connector, and cable ties with shield
function of the VARITECTOR SPC. It kA (8/20 μs) is realized by a snap-on cover EMC tie. The conductor shield
ensures that maintenance intervals can connection to the mounting rail. A can easily be connected to the
easily be adhered to, which is required direct contact with the PE arrestor is clamping yoke connections of the
by IEC 62305. established and excellent discharge VARITECTOR SPC modules.
properties are guaranteed for years.
For four binary signals or two analogue
signals in just 17.8 mm of space are
needed. The screw-free PE arrestor
connection reliably enables the
discharge of impulse currents up to 20
kA (8/20 μs) and 2.5 kA (10/350 μs)
via a grounded mounting rail.

2
Contents
For instrumentation, control and automation circuits

10 Analogue / Current Loop Protection

10 VARITECTOR SPC
18 VARITECTOR SSC 4AN
20 VARITECTOR SSC 6AN

24 Binary Digital Signal Protection

24 VARITECTOR SPC
28 VARITECTOR SSC 4AN
30 VARITECTOR SSC 6AN

34 Other Communication Types

34 VARITECTOR SPC
36 VARITECTOR SSC 6AN

38 Accessories

38 VSPC CONTROL UNIT 24 V DC


39 VSPC V-TEST
39 MARKING SOLUTIONS
39 EMC SET

3
VARITECTOR SPC
On 17.8 mm - four binary or two analogue signals
with error messages and remote signaling

Quick Identification
Convenient and Safe Large Variety Colour-coded marking: simple
Misconnection of the modules is A solution for every type of surge identification of the different voltage
prevented by a coding element protection: current loops and binary levels in the switching cabinet.
signals as well as integrated components ≤ 12 V = green
and combinations of current loops and 24 V = binary signal, blue
voltage supply e.g. 24 V. 24 V = analogue signal, yellow
48 V = red
60 V = violet

Tester
The pluggable arrestor VSPC can be
tested with the V-TEST test instrument
to comply with maintenance intervals
in accordance with IEC 62305. Also
suitable for energy surge protection
units PU I and PU II.

Monitoring Function
Status display and message
function: the protective function
can be evaluated externally.

Standard-Conformant
Usable in accordance with installations
standard IEC 62305: safely discharges
high impulse currents up to 20 kA
(8/20 µs) and 2,5 kA (10/350 µ) to
PE. Tested for classes D1, C2 and C1
to IEC 61643-21.

4
VARITECTOR SSC
Large variety: the solution for all cases of surge protection equipment

Quick Identification
Large-scale marking options: marking
of connections for equipment or
individual devices and colour-coded
markings of the various voltage
levels for quick identification in the
switching cabinet.

EMC Set
Large Variety Comprises shield connector and
More than 100 varieties: current cable ties with shield cover. Using the
loops and binary signals for 5 V, 12 V, EMC set, the conductor shield can
24 V, 48 V and 60 V and integrated easily be connected to the clamping
components such as varistors. yoke connections of the VSSC or
VSPC modules.

Convenient
Comprises a clamping range
from 0.5 mm≈ to 6 mm≈ with a
slotted-head Torx screw and a
locking torque of 0.8 to 1.0 Nm.

Easy and Safe


Easy installation and high safety
through direct PE connection when
snapped onto the mounting rail; high
discharge current of up to 20 kA.
Space-Saving
Only 6.2 mm of line-up
clamping width for binary or
analogue signals.

5
PROTECTION OF ANALOGUE SIGNALS

Protection of analogue signals and


current loops (CL)
Analogue Signals
In practice, the most common signals 11 12

Grounded Surge Protection


are analogue signals, also called
9 10

7 8

current-loop signals. In most cases,


5 6

3 4

analogue signals are needed to


1 2

TS

verify limit values (e.g., maximum or


unprotected protected

minimum temperature). Mostly, these


signals are used for long distances. 3
The standard forms are:
4 – 20 mA

4
0 – 20 mA
0–10 V

In practice, for example two-wire,


threewire and four-wire measurements
without common reference potential
are carried out. The more wires
Analogue Signals
there are, the more precise the 11 12

measurements get with the means


9

7
10

8
Floating-Ground
Surge Protection
of protection thus becoming more
5 6

3 4

important as well.
1 2

unprotected protected

Practical examples include:


TS

- Level measurements
- Signals of voltage transmitters
- PT 100 measurements
- Temperature measurements

n ≤ 10 2

VSPC
CONTROL UNIT

VSPC VSPC VSPC VSPC VSPC VSPC VSPC VSPC VSPC VSPC 2

X2 X
2

X2 X X2 X X2 X X2 X X2 X X2 X X2 X X2 X X2 X X2 X

Error detection and error messages for two current loops


or four binary signals with V-Control unit, a diagnosis or
+-
messaging module.

6
PROTECTION OF BINARY SIGNALS

Protection of binary signals


(SL – symmetrical loop)
Binary Signals
11

9
12

10 Floating-Ground
Binary signals refer to bivalent (binary)
5
7 8

6 Surge Protection
states of processes. They can be
3

1
4 described as 1/0 or as on/off. These
defined states are also called logical
2

unprotected protected

TS
values.

The standard forms are:


0 ... 10 V
2 5 V ... 60 V
24 V

For binary signals, there are two kinds


of surge protection components
available - those with a common
reference potential and those without.
Binary Signals
Two-wire connections are usually made
11 12

9 10 Grounded Surge Protection


with a common reference potential.
7 8

5 6

These signals are for example signals


3 4

1 2

from binary sensors, actuators or


TS
unprotected protected

indicators.

Practical examples include:


1 - Limit switches
- Push buttons
- Position sensors
- Photoelectric detectors
- Contactors
- Solenoid valves
- Signal lamps

The surge protection for floating-


Up to ten VSPC surge protection ground (FG) models of binary signals
modules can be incorporated into one is used in all applications, in which
monitoring circuit. Using the V-Control potential shifts may occur. These are
unit, also line breaks or interruptions in mainly signals received in the field
the circuit can be signaled. and transported over long distances.
With this model, a gas discharge tube
is introduced in series between the
PE and the surge protection. This gas
discharge tube inhibits coupling via PE.

The surge protection for grounded


models of binary signals is used
mainly in those fields, in which all
signals are laid directly to one star point
or to one potential.

7
SIMPLE AND PRECISE ISOLATION
The integrated disconnect lever
guarantees that the measurement /
control circuit can be quickly & precisely
switched off to test the signal path

TESTING EASE
All connections are easily tested utilising
the integrated test socket (Torx®/slot
headed scew) and test plug.

IEC COMPLIANT
All VARITECTOR products comply with the
latest IEC 61643-21:2008 requirement
and with categories D1, C1, C2 and C3
according to IEC 61643-22.

SURGE PROTECTION
FOR CONTROL & INSTRUMENTATION
Including disconnect/measurement function
Weidmüllers New VSSC range of surge diverters provide surge protection for control & instrumentation circuits
coupled with a market leading range of features (test points, disconnection, indication and identification). The entire
VSSC range has been designd and tested to meet the current IEC standards and provide up to 20KA protection.

Weidmüllers VSSC range will enable you to protect your installation without sacrificing space, design & serviceability.

www.weidmuller.com.au
Selection Guide

VARITECTOR SPC - Choice of device depending on the interface


Order No. Pluggable arrestor with operation Order No.
Interface Pluggable arrestor Reference No. Reference No.
Arrestor message (R) Arrestor
0(4) … 20 mA VSPC 2CL 24Vdc 0,5A 8924470000 Page 13 VSPC 2CL 24Vdc 0,5A R 8951480000 Page 13
0(4) … 20 mA VSPC 1CL 24Vdc 0,5A 8924480000 Page 11 VSPC 1CL 12Vdc 0,5A R 8951540000 Page 11
0 … 10 V VSPC 2CL 24Vdc 0,5A 8924470000 Page 13 VSPC 2CL 24Vdc 0,5A R 8951480000 Page 13
0 … 10 V VSPC 1CL 24Vdc 0,5A 8924480000 Page 11 VSPC 1CL 12Vdc 0,5A R 8951540000 Page 11
ASI PU III R 48Vdc 8860350000 Cat 4.4 PU III R 48Vdc 8860350000 Cat 4.4
PU III R 24Vdc 8860360000 Cat 4.4 PU III R 24Vdc 8860360000 Cat 4.4
Genius I/O Bus VSPC 2CL 12Vdc 0,5A 8924440000 Page 13 VSPC 2CL 12Vdc 0,5A R 8951470000 Page 13
Hart VSPC 1CL 24Vdc 0,5A 8924480000 Page 11 VSPC 1CL 24Vac 0,5A R 8951560000 Page 11
Cathodic corrosion VSPC GDT 2ch 90V20kA 8924570000 Cat 4.4 Cat 4.4
prevention
LON (Works) VSPC 1CL 48Vac 0,5A 8924520000 Page 11 Page 11
M-Bus (Remote VSPC 1CL 24Vac 0,5A 8924500000 Page 11 VSPC 1CL 24Vdc 0,5A R 8951550000 Page 11
readout of counter)
MODBUS(-PLUS) VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
MPI-Bus VSPC R485 2ch 8924670000 Page 35
N2 Bus VSPC 2SL 5Vdc 0,5A 8924210000 Page 25 VSPC 2SL 5Vdc 0,5A R 8951610000 Page 25
Procontic CS31 VSPC 1CL 12Vdc 0,5A 8924450000 Page 11 VSPC 1CL 12Vdc 0,5A R 8951540000 Page 11
Procontic T200 VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
Profibus DP (FMS) VSPC 2CL HF 5Vdc 8924430000 Page 15 VSPC 2CL HF 5Vdc R 8951680000 Page 15
VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
Process-Bus, VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
Panel-Bus
PT100 VSPC 3/4WIRE 24VDC 8924550000 Cat 4.4
P-Bus PU III R 24Vdc 8860360000 Cat 4.4 PU III R 24Vdc 8860360000 Cat 4.4
PSM-EG-RS422… VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
PSM-EG-RS485… VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
RACKBUS VSPC 2CL HF 5Vdc 8924430000 Page 15 VSPC 2CL HF 5Vdc R 8951680000 Page 15
RS 422A, V.11, VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
X.27, RS 423A
RS 449 VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
RS 485 VSPC R485 2ch 8924670000 Page 35 VSPC R485 2ch R 8951670000 Page 35
RS-232-C/V.24 VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
SDLC VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
SecuriLan-LON-Bus VSPC 1CL 12Vdc 0,5A 8924450000 Page 11 VSPC 1CL 12Vdc 0,5A R 8951540000 Page 11
SINEC L1 VSPC 2CL HF 5Vdc 8924430000 Page 15 VSPC 2CL HF 5Vdc R 8951680000 Page 15
SINEC L2 DP VSPC 2CL HF 5Vdc 8924430000 Page 15 VSPC 2CL HF 5Vdc R 8951680000 Page 15
Profibus DP VSPC R485 2ch 8924670000 Page 35 VSPC R485 2ch R 8951670000 Page 35
TTY, 0(4) - 20 mA VSPC 2CL 24Vdc 0,5A 8924470000 Page 13 VSPC 2CL 24Vdc 0,5A R 8951480000 Page 13
U-BUS VSPC GDT 2ch 90V20kA 8924570000 Cat 4.4
V.35 VSPC 2CL HF 5Vdc 8924430000 Page 15 VSPC 2CL HF 5Vdc R 8951680000 Page 15
X.21/X.24 VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15
X.25/X.31 VSPC 2CL HF 12Vdc 8924460000 Page 15 VSPC 2CL HF 12Vdc R 8951690000 Page 15

This tables contains recommendations for the choice of device. Our technical consultants will be glad to assist you with your individual requirements.

VARITECTOR VSSC - Choice of device depending on the interface


Order No. Order No.
Interface VSSC4 Reference No. VSSC6 Reference No.
Arrestor Arrestor
0(4) … 20 mA VSSC4 CL 24Vuc 0.5A 1063730000 Page 19 VSSC 6CL 24Vuc 0.5A 1064170000 Page 21
0 … 10 V VSSC4 CL 24Vuc 0.5A 1063730000 Page 19 VSSC 6CL 24Vuc 0.5A 1064170000 Page 21
Genius I/O Bus VSSC4 CL 12Vdc 0.5A 1063720000 Page 19 VSSC 6CL 12Vdc 0.5A 1064150000 Page 21
Hart VSSC4 CL 24Vuc 0.5A 1063730000 Page 19 VSSC 6CL 24Vuc 0.5A 1064170000 Page 21
LON (Works) VSSC4 CL 48Vuc 0.5A 1063740000 Page 19 VSSC 6CL 48Vuc 0.5A 1064190000 Page 21
M-Bus (Remote VSSC4 CL 24Vuc 0.5A 1063730000 Page 19 VSSC 6CL 24 Vuc 0.5A 1064170000 Page 21
readout of counter)
MODBUS(-PLUS) - - - VSSC 6RS485 1064980000 Page 36
Procontic CS31 VSSC4 CL 12Vdc 0.5A 1063720000 Page 19 VSSC 6CL 12 Vdc 0.5A 1064150000 Page 21
RS 485 - - - VSSC 6RS485 1064980000 Page 36
SecuriLan-LON-Bus VSSC4 CL 12Vdc 0.5A 1063720000 Page 19 VSSC 6CL 12 Vdc 0.5A 1064150000 Page 21
Profibus DP - - - VSSC 6RS485 1064980000 Page 36

This tables contains recommendations for the choice of device. Our technical consultants will be glad to assist you with your individual requirements.

Colour Coding
Voltage level Colour Voltage level Colour
≤ 12 V Green 48 V Red
24 V Binary Blue ≥ 60 V Violet
24 V Analogue Yellow Special function White

9
Analogue / Current Loop Protection | VARITECTOR SPC
Analogue / Current Loop Protection

VSPC 1CL - Protection for one analogue signal Imax 10kA

• Optional monitoring function with status indicator and alert function


• Pluggable arrester (plug-in/disconnect interruption-free and impedance neutral)
• Testable with V-TEST instrument
• Version with non-earthed PE connection for avoiding potential differences
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA
(8/20 μs) and 2.5 kA (10/350 μs) to PE
• IEC EX/ATEX versions available

Technical data
11 12 for all VSPC 1CL
7 8
Dielectric strength with FG against PE > 500 V
GND 9 10 GND
Volume resistivity per path 2.2 Ω
Overstressed fault mode Mode 2
3 4
TS Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
5 6 Surge strength C1 < 1 kA / 8/20 µs
Surge strength C2 5 kA / 8/20 µs
1 2
Surge strength C3 100 A / 10/1000 µs
unprotected protected Surge strength D1 1 kA 10/350 µs
Complete module, direct earthing Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
11 12 Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 10 kA / 10 kA
7 8 Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
GND 9 10 GND Type of connection Pluggable in VSPC BASE
OK FAULT
X2 Storage temperature -40 °C…+80 °C
X1

3 4
Ambient temperature (operational) -40 °C…+70 °C
TS Rel. humidity 5 %…96 % RH
5 6 Degree of protection IP20

1 2
unprotected protected

Complete module, direct earthing, with remote alert

11 12

7 8

GND 9 10 GND

3 4
TS

5 6

1 2
unprotected protected

Complete module, indirect earthing


11 12

7 8

GND 9 10 GND
OK FAULT
X2
X1

3 4
TS

5 6

Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
1 2 Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
Note
unprotected protected

Complete module, indirect earthing, with remote alert

This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 8924730000
Base element, indirect earthing via spark gap (FG, floating ground) 1 8924290000
Base element, direct earthing with remote alert 1 8951730000
Base element, indirect earthing with remote alert 1 8951740000
EX Base element, indirect earthing via spark gap (FG, floating ground) 1 8951810000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

10
Analogue / Current Loop Protection | VARITECTOR SPC

Analogue / Current Loop Protection


VSPC 1CL – arrester / plug-in elements

Ordering data VSPC 1CL 12 V DC VSPC 1CL 24 V DC

Rated voltage (DC) 12 V DC 24 V DC


Max. continuous voltage, Uc (DC) 15 V DC 28 V DC
Alternating-current strength
Rated current 450 mA / 350 mA (EX Version) 450 mA / 350 mA (EX Version)
Surge strength
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R
with VSPC CONTROL UNIT with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 730 KHz 730 KHz
Impulse reset 20 ms 30 ms
tested acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 650 V < 650 V
wire-wire / wire-PE / GND-PE 25 V / 450 V / 650 V 45 V / 450 V / 650 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 25 V < 45 V
input 8/20 μs, typ. < 25 V < 45 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 450 V < 450 V
input 8/20 μs, typ. < 650 V < 650 V
Ordering data
Without signaling contact/function indicatorType VSPC 1CL 12VDC 0.5A VSPC 1CL 24VDC 0.5A
 Order No. 8924450000 8924480000
With signaling contact/function indicator Type VSPC 1CL 12VDC 0.5A R VSPC 1CL 24VDC 0.5A R
 Order No. 8951540000 8951550000
EX Version Type VSPC 1CL 12VDC EX VSPC 1CL 24VDC EX
 Order No. 8953590000 8953600000
Note

Ordering data VSPC 1CL 24 V AC VSPC 1CL 48 V AC

Rated voltage (DC) 24 V AC / 34 V DC 48 V AC / 68 V DC


Max. continuous voltage, Uc (DC) 28 V AC / 39 V DC 60 V AC / 85 V DC
Alternating-current strength
Rated current 450 mA 350 mA
Surge strength
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R no
with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 730 KHz 730 KHz
Impulse reset 30 ms 100 ms
tested acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 650 V < 650 V
wire-wire / wire-PE / GND-PE 60 V / 450 V / 650 V 85 V / 450 V / 650 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 60 V < 85 V
input 8/20 μs, typ. < 60 V < 85 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 450 V < 450 V
input 8/20 μs, typ. < 650 V < 650 V
Ordering data
Without signaling contact/function indicatorType VSPC 1CL 24VAC 0.5A VSPC 1CL 48VAC 0.5A
 Order No. 8924500000 8924520000
With signaling contact/function indicator Type VSPC 1CL 24VAC 0.5A R
 Order No. 8951560000
Note

11
Analogue / Current Loop Protection | VARITECTOR SPC
Analogue / Current Loop Protection

VSPC 2CL - Protection for two analogue signals Imax 10kA

• Optional monitoring function with status indicator and alert function


• Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral)
• Testable with V-TEST instrument
• Space-saving design for two analog signals with signaling contact, without
additional space requirements
• Version with non-earthed PE connection for avoiding potential differences
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE
• IEC EX/ATEX versions available

Technical data
11 12 for all VSPC 2CL
Dielectric strength with FG against PE > 500 V
7 8 Volume resistivity per path 2.2 Ω
GND 9 10 GND Overstressed fault mode Mode 2
3 4
Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
TS
5 6
Surge strength C1 < 1 kA / 8/20 µs
Surge strength C2 5 kA / 8/20 µs
1 2 Surge strength C3 100 A / 10/1000 µs
unprotected protected
Surge strength D1 1 kA 10/350 µs
Complete module, direct earthing Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
11 12 Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 2 x 10 kA / 10kA
Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
7 8 Degree of protection IP20
GND 9
OK FAULT
10 GND
Type of connection Pluggable in VSPC BASE
X2
X1 Storage temperature -40 °C…+80 °C
3 4 Ambient temperature (operational) -40 °C…+70 °C
TS
5 6
Rel. humidity 5 %…96 % RH
Degree of protection IP20
1 2
unprotected protected

Complete module, direct earthing, with remote alert

11 12

7 8

GND 9 10 GND

3 4
TS
5 6

1 2
unprotected protected

Complete module, indirect earthing


11 12

7 8

GND 9 10 GND
OK FAULT
X2
X1

3 4
TS
5 6
Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
1 2 Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
unprotected protected
Note
Complete module, indirect earthing, with remote alert

This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 8924710000
Base element, indirect earthing via spark gap (FG, floating ground) 1 8924270000
Base element, direct earthing with remote alert 1 8951710000
Base element, indirect earthing with remote alert 1 8951720000
EX Base element, indirect earthing via spark gap (FG, floating ground) 1 8951820000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

12
Analogue / Current Loop Protection | VARITECTOR SPC

Analogue / Current Loop Protection


VSPC 2CL – arrester / plug-in elements

Ordering data VSPC 2CL 12 V DC VSPC 2CL 24 V DC

Rated voltage (DC) 12 V DC 24 V DC


Max. continuous voltage, Uc (DC) 15 V DC 28 V DC
Alternating-current strength
Rated current 450 mA 450 mA / 250 mA (EX Version)
Surge strength
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R
with VSPC CONTROL UNIT with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 2.4 MHz 2.2 MHz
Impulse reset 20 ms 30 ms
tested acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage UP < 800 V < 800 V
wire-wire / wire-PE / GND-PE 25 V / 450 V / 800 V 45 V / 450 V / 800 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 25 V < 45 V
input 8/20 μs, typ. < 25 V < 45 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 450 V < 450 V
input 8/20 μs, typ. < 800 V < 800 V
Ordering data
Without signaling contact/function indicatorType VSPC 2CL 12VDC 0.5A VSPC 2CL 24VDC 0.5A
 Order No. 8924440000 8924470000
With signaling contact/function indicator Type VSPC 2CL 12VDC 0.5A R VSPC 2CL 24VDC 0.5A R
 Order No. 8951470000 8951480000
EX Version Type VSPC 2CL 24VDC EX
 Order No. 8953720000
Note

Ordering data VSPC 2CL 24 V AC VSPC 2CL 48 V AC

Rated voltage (DC) 24 V AC / 34 V DC 48 V AC / 68 V DC


Max. continuous voltage, Uc (DC) 28 V AC / 39 V DC 60 V AC / 85 V DC
Alternating-current strength
Rated current 450 mA 350 mA
Surge strength
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R no
with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 3 MHz 3 MHz
Impulse reset 450 ms 500 ms
tested acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 650 V < 650 V
wire-wire / wire-PE / GND-PE 60 V / 450 V / 800 V 85 V / 450 V / 650 V
Protection level on output side sym., 500 ms
input 1 kV/μs, typ. < 60 V < 85 V
input 8/20 μs, typ. < 60 V < 85 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 450 V < 450 V
input 8/20 μs, typ. < 800 V < 650 V
Ordering data
Without signaling contact/function indicatorType VSPC 2CL 24VAC 0.5A VSPC 2CL 48VAC 0.5A
 Order No. 8924490000 8951490000
With signaling contact/function indicator Type VSPC 2CL 24VAC 0.5A R
 Order No. 1093400000
Note

13
Analogue / Current Loop Protection | VARITECTOR SPC
Analogue / Current Loop Protection

VSPC 2CL HF – for high transmission rates Imax 10kA


without signal delays

• Optional monitoring function with status indicator and alert function


• Pluggable arrester (plug-in / disconnect interruption-freeand impedance neutral)
• Testable with V-TEST instrument
• Space-saving design with optional signaling contact, without additional
space requirements
• High transmission rates with low attenuation values
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE

Technical data
11 12
for all VSPC 2CL HF
Dielectric strength with FG against PE > 500 V
7 8 Rated current 450 mA
GND 9 10 GND Volume resistivity per path 2.2 Ω
3
TS
4 Overstressed fault mode Mode 2
5 6 Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
Surge strength C1 < 1 kA / 8/20 µs
Surge strength C2 5 kA / 8/20 µs
1 2
unprotected protected Surge strength C3 100 A / 10/1000 µs
Complete module, direct earthing Surge strength D1 1 kA 10/350 µs
11 12
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 2 x 10 kA / 10kA
7 8 Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
GND 9 10 GND
OK FAULT
X2
Degree of protection IP20
X1 Type of connection Pluggable in VSPC BASE
3
TS
4
Storage temperature -40 °C…+80 °C
5 6 Ambient temperature (operational) -40 °C…+70 °C
Rel. humidity 5 %…96 % RH
1 2 Degree of protection IP20
unprotected protected

Complete module, direct earthing, with remote alert


11 12

7 8
GND 9 10 GND

3 4
TS
5 6

1 2
unprotected protected

Complete module, indirect earthing


11 12

7 8
GND 9 10 GND
OK FAULT
X2
X1
3 4
TS
5 6

Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
1 2
Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
unprotected protected
Note
Complete module, indirect earthing, with remote alert

This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 8924710000
Base element, indirect earthing via spark gap (FG, floating ground) 1 8924270000
Base element, direct earthing with remote alert 1 8951710000
Base element, indirect earthing with remote alert 1 8951720000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

14
Analogue / Current Loop Protection | VARITECTOR SPC

Analogue / Current Loop Protection


VSPC 2CL HF – arrester / plug-in elements

Ordering data VSPC 2CL HF 5 V DC VSPC 2CL HF 12 V DC VSPC 2CL HF 24 V DC

Rated voltage (DC) 5 V DC 12 V DC 24 V DC


Max. continuous voltage, Uc (DC) 6.4 V DC 15 V DC 28 V DC
Alternating-current strength
Surge strength
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R
with VSPC CONTROL UNIT with VSPC CONTROL UNIT with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 1.5 MHz 1.5 MHz 1.5 MHz
Impulse reset 20 ms 20 ms 40 ms
tested acc. to IEC61643-21 acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 800 V < 800 V < 800 V
wire-wire / wire-PE / GND-PE 12 V / 450 V / 800 V 25 V / 450 V / 800 V 45 V / 450 V / 800 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 12 V < 25 V < 45 V
input 8/20 μs, typ. < 12 V < 25 V < 45 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 450 V < 450 V < 450 V
input 8/20 μs, typ. < 800 V < 800 V < 800 V

Ordering data
Without signaling contact/function indicatorType VSPC 2CL HF 5VDC VSPC 2CL HF 12VDC VSPC 2CL HF 24VDC
 Order No. 8924430000 8924460000 8924510000
With signaling contact/function indicator Type VSPC 2CL HF 5VDC R VSPC 2CL HF 12VDC R VSPC 2CLHF 24VDC R
 Order No. 8951680000 8951690000 8951700000
Note

15
Analogue / Current Loop Protection | VARITECTOR SPC
Analogue / Current Loop Protection

VSPC 1CL PW – combinations of current loop Imax 10kA


signal and power circuit

• Optional monitoring function with status indicator


• Pluggable arrester (plug-in / disconnect interruption-free
and impedance neutral)
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges
up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE
• Suitable for 4 wire analogue
• IEC EX/ATEX versions available

Technical data
for all VSPC 1CL PW
11 12 C&I protection data
Rated voltage (DC) 24 V AC / 34 V DC
7 8 Max. continuous voltage, Uc (DC) 27 V AC / 38 V DC
GND 9 10 GND Dielectric strength with FG against PE > 500 V / >350 mA (EX Version)
3
TS
4 Rated current 450 mA
5 6 Volume resistivity per path 2.2 Ω
 Overstressed fault mode Mode 2
U
Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
Optical function indicator green = OK; red = arrester faulty, replace
U FAULT 24 V~
Rated voltage (AC/DC) 24 V AC / 33 V DC
Surge strength C1 < 1 kA / 8/20 µs
 Surge strength C2 5 kA / 8/20 µs
1 2
unprotected protected Surge strength C3 100 A / 10/1000 µs
Complete module, direct earthing Surge strength D1 2.5 kA 10/350 µs
Transmission test (-3dB) 730 KHz
11 12
Impulse reset 10 ms
tested acc. to IEC61643-21, IEC61643-1
7 8 Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
GND 9 10 GND Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 10 kA / 10 kA
Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
3 4
TS
Residual voltage Up 800 V
5 6
Residual voltage Up wire-wire / wire-PE / GND-PE 60 V / 450 V / 800 V

Protection level on output side sym., input 1 kV/μs, typ. < 60 V
U
Protection level on output side sym., input 8/20 μs, typ. < 60 V
U FAULT 24 V~
Protection level on output side unsym., input 1 kV/μs, typ. < 450 V
Protection level on output side unsym., input 8/20 μs, typ. < 800 V
 Protection of the device
1 2 Rated voltage (DC) 24 V AC / 34 V DC
unprotected protected
Max. continuous voltage, Uc (DC) 27 V AC / 38 V DC
Complete module, indirect earthing
Combined pulse 6 kV
Residual voltage Up 900 V
Rated current 10 A
General data
Type of connection Pluggable in VSPC BASE
Storage temperature -40 °C…+80 °C
Requirement category acc. to IEC 61643-1 Class III
Ambient temperature (operational) -40 °C…+70 °C
Rel. humidity 5 %…96 % RH
Degree of protection IP20
Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
Note
This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 1070230000
Base element, indirect earthing via spark gap (FG, floating ground) 1 1105700000
EX Base element, indirect earthing via spark gap (FG, floating ground) 1 1070470000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

16
Analogue / Current Loop Protection | VARITECTOR SPC

Analogue / Current Loop Protection


VSPC 1CL PW – arrester / plug-in elements

Ordering data VSPC 1CL PW 24 V

Without signaling contact/function indicatorType VSPC 1CL PW 24V 0.5A


 Order No. 8951510000
EX Version Type VSPC 1CL PW 24V EX
 Order No. 8953610000
Note

17
Analogue / Current Loop Protection | VARITECTOR SSC 4AN
Analogue / Current Loop Protection

VARITECTOR SSC 4 CL and CL FG Imax 5kA

Two-stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal-block format
• Modular width of just 6.2 mm
• Space-saving design: 1 analogue signal
• Torx slotted screw connection
• Version with non-earthed PE connection for avoiding potential differences
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE
• IEC EX/ATEX versions available

Technical data
General data
Nominal current IN at 25 °C 500 mA
Rated discharge current IN (8 / 20 µs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / -
1 3 Rated discharge current Imax (8 / 20 µs) wire-wire / wire-PE / GND-PE 5 kA / 5 kA / -
Response time wire-wire / wire-PE / GND-PE ≤ 1 ns / ≤ 100 ns / -
Volume resistivity per path 1.8 Ω ± 10%
Discharge current Itotal 10 kA
Rated discharge current Iimp (10 / 350 µs) 1 kA
Surge strength 4 kV / 2 kA, 10 repetitions
2 TS 4
Max. continuous voltage 1 A / 1 s, 5 repetitions
unprotected protected Overstressed fault mode Mode 2
VSSC4 CL
Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
Rel. humidity 5%…96% RH
Degree of protection IP20
Ambient temperature (operational) -40 °C…+70 °C
Storage temperature -40 °C…+80 °C
1 3 Approvals UL, CSA pending
Clampable conductor
Connection Torx screw (T15) / slot (0.8 x 4.0)
Stripping length 7 mm
Tightening torque range 0.5 … 0.8 Nm
2 TS
4 Solid / stranded 0.5 … 6 mm² / 0.5 … 4 mm²
unprotected protected Flexible / flexible with ferrule 0.5 … 2.5 mm²

VSSC4 CL FG Dimensions
Length x Width x Height mm 76 x 6.2 x 58.5
Note: end plate AP VSSC4: 1063120000
This is a graphical representation only.

Applications

0.8
Load current I [A]

0.6

0.4 0.4

0.2

0
-40 0 15 42.5 70

Ambient temperature T [°C]

18
Analogue / Current Loop Protection | VARITECTOR SSC 4AN

Analogue / Current Loop Protection


PRODUCT SELECTION

VARITECTOR SSC 4 CL and CL FG

Ordering data VSSC4 CL 12 V DC 0.5 A VSSC4 CL FG 12 V DC 0.5 A VSSC4 CL 24 V UC 0.5 A

Rated voltage UN 12 V DC 12 V DC 24 V AC / 34 V DC
Max. continuous voltage UC 15 V DC 15 V DC 30 V AC / 42 V DC
Voltage GND-PE - > 500 V -
Capacitance 4 nF 4 nF 650 pF
Gas discharge tube 90 V 90 V 90 V
Supressordiode UP 16 V 16 V 43V
Limiting frequency (-3 dB) at load resistance 250 kHz 250 kHz 1.5 MHz
Protection level at
IN wire-wire / wire-PE / GND-PE 35 V / 600 V / - 35 V / 1500 V / - 90 V / 600 V / -
1 kV / µs wire-wire / wire-PE / GND-PE 30 V / 600 V / - 30 V / 1500 V / - 70 V / 600 V / -

Ordering data
Type VSSC4 CL 12VDC 0.5A VSSC4 CL FG 12VDC 0.5A VSSC4 CL 24VUC 0.5A
 Order No. 1063720000 1063760000 1063730000
Note

Ordering data VSSC4 CL FG 24 V UC 0.5 A VSSC4 CL 48 V UC 0.5 A VSSC4 CL FG 48 V UC 0.5 A

Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC 48 V AC / 68 V DC
Max. continuous voltage UC 30 V AC / 42 V DC 60 V AC / 85 V DC 60 V AC / 85 V DC
Voltage GND-PE > 500 V / 300 mA (EX Version) - > 500 V / 300 mA (EX Version)
Capacitance 650 pF 450 pF 450 pF
Gas discharge tube 90 V 150 V 150 V
Supressordiode UP 43V 91 V 91 V
Limiting frequency (-3 dB) at load resistance 1.5 MHz 2.2 MHz 2.2 MHz
Protection level at
IN wire-wire / wire-PE / GND-PE 90 V / 1500 V / - 200 V / 600 V / - 200 V / 1500 V / -
1 kV / µs wire-wire / wire-PE / GND-PE 70 V / 1500 V / - 150 V / 600 V / - 150 V / 1500 V / -

Ordering data
Type VSSC4 CL FG 24VUC 0.5A VSSC4 CL 48VUC 0.5A VSSC4 CL FG 48VUC 0.5A
 Order No. 1063770000 1063740000 1063780000
EX Version Type VSSC4 CL FG 24VUC EX VSSC4 CL FG 48VUC EX
 Order No. 1063810000 1063820000
Note

19
Analogue / Current Loop Protection | VARITECTOR SSC 6AN
Analogue / Current Loop Protection

VSSC 6AN CL and TR CL – protection for Imax 5kA


analogue signals (CL) with disconnect lever (TR)

Two stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal block format
• Modular width of just 6.2 mm
• Space saving design: 1 analogue signal
• Torx® slotted screw connection
• Can be used to comply with the IEC 62305 installation
standard and the IEC 61643-1/-22 standards Similar to Similar to Similar to Similar to
• Integrated PE contact in base element, safely discharges illustration illustration illustration illustration
up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE

Technical data
General data
Nominal current 500 mA (see derating curve)
Dielectric strength at FG against PE –
1 4
Volume resistivity 1.8 Ω ± 10 %
Overstressed fault mode Mode 2
Requirement category IEC 61643-21 C2; C3; D1
Standards IEC 61643-21
Surge strength C2 2.5 kA
2 5 Surge strength C3 50 A
Surge strength D1 0.5 kA
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / –
3 TS 6 Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 5 kA / 5 kA / –
Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE – / 0.5 kA / –
Storage temperature -40 °C...+80 °C
UNPROTECTED PROTECTED Ambient temperature (operational) -40 °C...+70 °C
VSSC 6 CL Humidity 5...96 % RH
Degree of protection IP20
Flammability class V0
Connection data
Connection Torx® T15 / slot 0.8 x 4
Tightening torque 0.5 Nm
1 4 Conductor cross section, flexible, ferrule (DIN 46228-1), max. 4 mm²
Conductor cross section, flexible, ferrule (DIN 46228-1), min. 0.5 mm²
Conductor cross section, solid, max. 6 mm²
Conductor cross section, solid, min. 0.5 mm²
Conductor cross section, stranded, Rated connection, max. 4 mm²
Conductor cross section, stranded, Rated connection, min. 0.5 mm²
2 5 Stripping length 10 mm
Mounting rail TS35
Dimensions
3 TS 6 Length x width x height 88.5 x 6.2 x 81 mm

UNPROTECTED PROTECTED

VSSC 6 TR CL

I/A Derating curve


1

0.8

0.6 0.6 0.6 0.6


0.5
0.4 0.4

0.2

0 TU
-40 ºC 0 ºC 15 ºC 42.5 ºC 70 ºC

Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000;
marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000
This is a graphical representation only.

20
Analogue / Current Loop Protection | VARITECTOR SSC 6AN

Analogue / Current Loop Protection


PRODUCT SELECTION

VSSC 6 CL and TR CL

Technical data CL 12 V DC CL 24 V UC CL 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 20 ms ≤ 170 ms ≤ 150 ms
Residual voltage UP ≤ 1600 V ≤ 1650 V ≤ 1510 V
wire-wire / wire-PE / GND-PE 35 V / 900 V / - 90 V / 900 V / - 200 V / 770 V / -
Protection level on output side sym.,
input 1 kV/µs, typ. 30 V 70 V 70 V

Protection level on output side unsym.,


input 1 kV/µs, typ. 900 V 900 V 770 V

Ordering data
Type VSSC6 CL 12Vdc 0.5A VSSC6 CL 24Vuc 0.5A VSSC6 CL 48Vuc 0.5A
 Order No. 1064150000 1064170000 1064190000
Note

Technical data TR CL 12 V DC TR CL 24 V UC TR CL 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC/ 34 V DC 48 V AC / 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC/ 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 20 ms ≤ 170 ms ≤ 150 ms
Residual voltage UP ≤ 1600 V ≤ 1650 V ≤ 1510 V
wire-wire / wire-PE / GND-PE 35 V / 900 V / - 90 V / 900 V / - 200 V / 770 V / -
Protection level on output side sym.,
input 1 kV/µs, typ. 30 V 70 V 150 V

Protection level on output side unsym.,


input 1 kV/µs, typ. 900 V 900 V 770 V

Disconnect lever Yes Yes Yes


Testing option Functional screw with test plug receptacle Functional screw with test plug receptacle Functional screw with test plug receptacle
connection 1, 2, 4, 5 connection 1, 2, 4, 5 connection 1, 2, 4, 5
Ordering data
Type VSSC6 TR CL 12Vdc 0.5A VSSC6 TR CL 24Vuc 0.5A VSSC6 TR CL 48Vuc 0.5A
 Order No. 1064220000 1064230000 1064240000
Note

21
Analogue / Current Loop Protection | VARITECTOR SSC 6AN
Analogue / Current Loop Protection

VSSC 6AN CLFG and TR CLFG – protection for


analogue signals (CL) with floating ground
(FG) with and without disconnect lever (TR) Imax 5kA

Two stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal-block format
• Modular width of just 6.2 mm
• Space saving design: 1 analogue signal
• Torx® slotted screw connection
• Can be used to comply with the IEC 62305 installation
standard and the IEC 61643-1/-22 applications standards.
• Integrated PE contact in base element, safely discharges Similar to Similar to Similar to
up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE illustration illustration illustration
• Version with floating ground PE connection used to avoid
differences in voltage potential
• IEC EX/ATEX versions available
Technical data
General data
Nominal current 500 mA (see derating curve)
1 4 Dielectric strength at FG against PE ≥ 500 V / 300 mA (EX Version)
Volume resistivity 1.8 Ω ± 10 %
Overstressed fault mode Mode 2
Requirement category acc. to IEC 61643-21 C2; C3; D1
Standards IEC 61643-21
Surge strength C2 2.5 kA
2 5
Surge strength C3 50 A
Surge strength D1 0.5 kA
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / –
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 5 kA / 5 kA / –
3 TS 6 Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE – / 0.5 kA / –
Storage temperature -40 °C...+80 °C
UNPROTECTED PROTECTED Ambient temperature (operational) -40 °C...+70 °C
Humidity 5...96 % RH
VSSC 6 CLFG Degree of protection IP20
Flammability class V0
Connection data
Connection Torx® screw T15 / slot 0.8 x 4
Tightening torque 0.5 Nm
1 4
Conductor cross section, flexible, ferrule (DIN 46228-1), max. 4 mm²
Conductor cross section, flexible, ferrule (DIN 46228-1), min. 0.5 mm²
Conductor cross section, solid, max. 6 mm²
Conductor cross section, solid, min. 0.5 mm²
Conductor cross section, stranded, Rated connection, max. 4 mm²
2 5 Conductor cross section, stranded, Rated connection, min. 0.5 mm²
Stripping length 10 mm
Mounting rail TS35
Dimensions
Length x width x height 88.5 x 6.2 x 81 mm
3 TS 6

UNPROTECTED PROTECTED

VSSC 6 TR CLFG

I/A Derating curve


1

0.8

0.6 0.6 0.6 0.6


0.5
0.4 0.4

0.2

0 TU
-40 ºC 0 ºC 15 ºC 42.5 ºC 70 ºC

Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000;
marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000
This is a graphical representation only.

22
Analogue / Current Loop Protection | VARITECTOR SSC 6AN

Analogue / Current Loop Protection


PRODUCT SELECTION

VSSC 6AN CLFG and TR CLFG

Technical data CLFG 12 V DC CLFG 24 V UC CLFG 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC/ 34 V DC 48 V AC / 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 20 ms ≤ 20 ms ≤ 20 ms
Residual voltage UP ≤ 35 V ≤ 85 V ≤ 90 V
wire-wire / wire-PE / GND-PE 35 V / 1600 V / 800 V 90 V / 1632 V / 800 V 200 V / 1510 V / 800 V
Protection level on output side sym.
Input 1 kV/µs, typ. 30 V 70 V 150 V

Protection level on output side unsym.,


Input 1 kV/µs, typ. 1600 V 1632 V 1510 V

Ordering data
Type VSSC6 CLFG 12VDC 0.5A VSSC6 CL FG24VUC 0.5A VSSC6 CLFG 48VUC 0.5A
 Order No. 1064260000 1064270000 1064280000
Note

Technical data TR CLFG 12 V DC TR CLFG 24 V UC TR CLFG 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V dc
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 20 ms ≤ 20 ms ≤ 20 ms
Residual voltage UP ≤ 35 V ≤ 85 V ≤ 90 V
wire-wire / wire-PE / GND-PE 35 V / 1600 V / 800 V 90 V / 1632 V / 800 V 200 V / 1510 V / 800 V
Protection level on output side sym.
Input 1 kV/µs, typ. 30 V 70 V 150 V

Protection level on output side unsym.,


Input 1 kV/µs, typ. 1600 V 1632 V 1510 V

Disconnect lever yes yes yes


Testing option Functional screw with test plug receptacle Functional screw with test plug receptacle Functional screw with test plug receptacle
connection 1, 2, 4, 5 connection 1, 2, 4, 5 connection 1, 2, 4, 5
Ordering data
Type VSSC6 TR CLFG 12Vdc0.5 VSSC6TR CLFG 24VUC 0.5A VSSC6 TR CLFG 48VUC 0.5A
 Order No. 1064300000 1064310000 1064320000
EX Version Type VSSC6TR CLFG 24VUC EX
 Order No. 1066490000
Note

23
Binary Digital Signal Protection | VARITECTOR SPC
Binary Digital Signal Protection

VSPC 2SL – Protection for two binary signals Imax 10kA

• Optional monitoring function with status indicator and alert function


• Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral)
• Testable with V-TEST instrument
• Version with non-earthed PE connection for avoiding potential differences
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE
• IEC EX/ATEX versions available

Technical data
11 12 for all VSPC 2SL
7 8 Dielectric strength with FG against PE > 500 V / 250 mA (EX Version)
GND 9 10 GND Volume resistivity per path 4.7 Ω
3 4 Overstressed fault mode Mode 2
TS
Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
5 6
Surge strength C1 < 1 kA / 8/20 µs
Surge strength C2 5 kA / 8/20 µs
1 2
Surge strength C3 100 A / 10/1000 µs
unprotected protected Surge strength D1 2.5 kA 10/350 µs
Complete module, direct earthing Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
11 12
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 10 kA / 10kA
7 8
Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
GND 9 10 GND
Type of connection Pluggable in VSPC BASE
OK FAULT
X2 Storage temperature -40 °C…+80 °C
X1
Ambient temperature (operational) -40 °C…+70 °C
3 4
TS Rel. humidity 5 %…96 % RH
5 6 Degree of protection IP20

1 2
unprotected protected

Complete module, direct earthing, with remote alert

11 12

7 8

GND 9 10 GND

0.4
3 4
TS
0.35
5 6

0.3
Current [mA]

1 2
0.25
unprotected protected

Complete module, indirect earthing 0.2

11 12 0.15

7 8
0.1
GND 9 10 GND
OK FAULT
X2 0.05
X1

3 4 0
TS 0 10 20 30 40 50 60 70 80 90 100
5 6
Ambient temperature [°C]

1 2
Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
unprotected protected Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
Complete module, indirect earthing, with remote alert Note

This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 8924720000
Base element, indirect earthing via spark gap (FG, floating ground) 1 8924280000
Base element, direct earthing with remote alert 1 8951770000
Base element, indirect earthing with remote alert 1 8951780000
EX Base element, indirect earthing via spark gap (FG, floating ground) 1 8951830000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

24
Binary Digital Signal Protection | VARITECTOR SPC

Binary Digital Signal Protection


VSPC 2SL – arrester / plug-in elements

Ordering data VSPC 2SL 5 V DC VSPC 2SL 12 V DC VSPC 2SL 12 V AC VSPC 2SL 24 V DC

Rated voltage UN 5 V DC 12 V DC 12 V AC / 16 V DC 24 V DC
Max. continuous voltage UC 6.4 V DC 15 V DC 13,2 V AC / 18 V DC 28 V DC
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R no UN 250 V AC 0.1 A 1CO at VSPC R
with VSPC CONTROL UNIT with VSPC CONTROL UNIT with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, green = OK; red = arrester faulty, green = OK; red = arrester faulty, green = OK; red = arrester faulty,
replace replace replace replace
Transmission test (-3dB) 750 KHz 750 KHz 750 KHz 750 KHz
Impulse reset 20 ms 20 ms 20 ms 30 ms
tested acc. to IEC61643-21 acc. to IEC61643-21 acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 25 V < 50 V < 50 V < 60 V
wire-wire / wire-PE / GND-PE 25 V / 25 V / 25 V 45 V / 50 V / 50 V 55 V / 50 V / 50 V 80 V / 60 V / 60 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 25 V < 45 V < 55 V < 80 V
input 8/20 μs, typ. < 25 V < 45 V < 55 V < 80 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 12 V < 25 V < 30 V < 40 V
input 8/20 μs, typ. < 25 V < 50 V < 50 V < 60 V
Rated current 300 mA 300 mA 300 mA 300 mA
Ordering data
Without signaling contact/function indicatorType VSPC 2SL 5VDC 0.5A VSPC 2SL 12VDC 0.5A VSPC 2SL 12VAC 0.5A VSPC 2SL 24VDC 0.5A
 Order No. 8924210000 8924230000 8924250000 8924330000
With signaling contact/function indicator Type VSPC 2SL 5VDC 0.5A R VSPC 2SL 12VDC 0.5A R VSPC 2SL 24VDC 0.5A R
 Order No. 8951610000 8951620000 8951630000
EX Version Type VSPC 2SL 12VDC EX VSPC 2SL 12VAC EX VSPC 2SL 24VDC EX
 Order No. 8953620000 8953630000 8953670000
Note

Ordering data VSPC 2SL 24 V AC VSPC 2SL 48 V AC

Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC
Max. continuous voltage UC 28 V AC / 39 V DC 60 V AC / 85 V DC
Signaling contact UN 250 V AC 0,1 A 1CO at VSPC R no
with VSPC CONTROL UNIT
Optical function indicator (VSPC R)
green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 750 KHz 750 KHz
Impulse reset 60 ms 60 ms
tested acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 60 V < 125 V
wire-wire / wire-PE / GND-PE 80 V / 60 V / 60 V 80 V / 125 V / 125 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 110 V < 210 V
input 8/20 μs, typ. < 80 V < 80 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 60 V < 85 V
input 8/20 μs, typ. < 60 V < 125 V
Rated current 300 mA 250 mA
Ordering data
Without signaling contact/function indicatorType VSPC 2SL 24VAC 0.5A VSPC 2SL 48VAC 0.5A
 Order No. 8924350000 8924370000
With signaling contact/function indicator Type VSPC 2SL 24VAC 0.5A R
 Order No. 8951640000
EX Version Type VSPC 2SL 48VAC EX
 Order No. 8953640000
Note

25
Binary Digital Signal Protection | VARITECTOR SPC
Binary Digital Signal Protection

VSPC 4SL – Protection for four binary signals Imax 10kA

• Optional monitoring function with status indicator and alert function


• Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral)
• Testable with V-TEST instrument
• Space-saving design for four binary signals with signaling contact, without
additional space requirements
• Version with non-earthed PE connection for avoiding potential differences
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE
• IEC EX/ATEX versions available

Technical data
11 12 for all VSPC 4SL
Volume resistivity per path 4.7 Ω
7 8 Overstressed fault mode Mode 2
GND 9 10 GND Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
3 4
Surge strength C1 < 1 kA / 8/20 µs
TS
5 6
Surge strength C2 5 kA / 8/20 µs
Surge strength C3 100 A / 10/1000 µs
1 2 Surge strength D1 2.5 kA 10/350 µs
unprotected protected
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
Complete module, direct earthing Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 10 kA / 10 kA
11 12 Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
Type of connection Pluggable in VSPC BASE
7 8
Storage temperature -40 °C … +80 °C
GND 9 10 GND Ambient temperature (operational) -40 °C … +70 °C
Rel. humidity 5 % … 96 % RH
OK FAULT
X2
X1

3 4
Degree of protection IP20
TS
5 6

1 2
unprotected protected

Complete module, direct earthing, with remote alert

11 12

7 8

GND 9 10 GND
0.4

3 4 0.35
TS
5 6
0.3
Current [mA]

1 2 0.25
unprotected protected

Complete module, indirect earthing 0.2

11 12 0.15

0.1
7 8

GND 9 10 GND 0.05


OK FAULT
X2
X1 0
0 10 20 30 40 50 60 70 80 90 100
3 4
TS Ambient temperature [°C]
5 6

Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
1 2 Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
Note
unprotected protected

Complete module, indirect earthing, with remote alert

This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 8924700000
Base element, indirect earthing via spark gap (FG, floating ground) 1 8924260000
Base element, direct earthing with remote alert 1 8951750000
Base element, indirect earthing with remote alert 1 8951760000
EX Base element, indirect earthing via spark gap (FG, floating ground) 1 8951840000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

26
Binary Digital Signal Protection | VARITECTOR SPC

Binary Digital Signal Protection


VSPC 4SL – arrester / plug-in elements

Ordering data VSPC 4SL 5 V DC VSPC 4SL 12 V DC VSPC 4SL 12 V AC VSPC 4SL 24 V DC

Rated voltage UN 5 V DC 12 V DC 12 V AC / 16 V DC 24 V DC
Max. continuous voltage UC 6.4 V DC 15 V DC 13.2 V AC / 18 V DC 28 V DC
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R UN 250 V AC 0.1 A 1CO at VSPC R no UN 250 V AC 0.1 A 1CO at VSPC R
with VSPC CONTROL UNIT with VSPC CONTROL UNIT with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, green = OK; red = arrester faulty, green = OK; red = arrester faulty,
green = OK; red = arrester faulty, replace
replace replace replace
Transmission test (-3dB) 730 KHz 750 KHz 750 KHz 750 KHz
Impulse reset 20 ms 20 ms 20 ms 30 ms
tested acc. to IEC61643-21 acc. to IEC61643-21 acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 25 V < 35 V < 50 V < 60 V
wire-wire / wire-PE / GND-PE 25 V / 25 V / 25 V 45 V / 20 V / 450 V 55 V / 50 V / 50 V 80 V / 60 V / 60 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 25 V < 45 V < 55 V < 80 V
input 8/20 μs, typ. < 25 V < 45 V < 55 V < 80 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 12 V < 25 V < 30 V < 40 V
input 8/20 μs, typ. < 25 V < 50 V < 50 V < 60 V
Rated current 350 mA 300 mA 300 mA 300 mA
Ordering data
Without signaling contact/function indicatorType VSPC 4SL 5VDC 0.5A VSPC 4SL 12VDC 0.5A VSPC 4SL 12VAC 0.5A VSPC 4SL 24VDC 0.5A
 Order No. 8924200000 8924220000 8924240000 8924320000
With signaling contact/function indicator Type VSPC 4SL 5VDC 0.5A R VSPC 4SL 12VDC 0.5A R VSPC 4SL 24VDC 0.5A R
 Order No. 8951570000 8951580000 8951590000
EX Version Type VSPC 4SL 12VDC EX VSPC 4SL 12VAC EX VSPC 4SL 24VDC EX
 Order No. 1161170000 1161150000 1161190000
Note

Ordering data VSPC 4SL 24 V AC VSPC 4SL 48 V AC

Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC
Max. continuous voltage UC 28 V AC / 39 V DC 60 V AC / 85 V DC
Signaling contact UN 250 V AC 0.1 A 1CO at VSPC R no
with VSPC CONTROL UNIT
Optical function indicator (VSPC R)
green = OK; red = arrester faulty, replace green = OK; red = arrester faulty, replace
Transmission test (-3dB) 750 KHz 750 KHz
Impulse reset 40 ms 60 ms
tested acc. to IEC61643-21 acc. to IEC61643-21
Residual voltage Up < 60 V < 125 V
wire-wire / wire-PE / GND-PE 80 V / 60 V / 60 V 80 V / 125 V / 125 V
Protection level on output side sym.,
input 1 kV/μs, typ. < 110 V < 210 V
input 8/20 μs, typ. < 80 V < 80 V
Protection level on output side unsym.,
input 1 kV/μs, typ. < 60 V < 85 V
input 8/20 μs, typ. < 60 V < 125 V
Rated current 300 mA 250 mA
Ordering data
Without signaling contact/function indicatorType VSPC 4SL 24VAC 0.5A VSPC 4SL 48VAC 0.5A
 Order No. 8924340000 8924360000
With signaling contact/function indicator Type VSPC 4SL 24VAC 0.5A R
 Order No. 8951600000
EX Version Type VSPC 4SL 24VAC EX
 Order No. 1161180000
Note

27
Binary Digital Signal Protection | VARITECTOR SSC 4AN
Binary Digital Signal Protection

VARITECTOR SSC 4 SL and SL FG Imax 10kA

Two-stage surge protection with screw connection for instrumentation,


control and automation technology
• Surge protection in terminal-block format
• Modular width of just 6.2 mm
• Space-saving design: 1 binary signal
• Torx slotted screw connection
• Version with non-earthed PE connection for avoiding potential differences
• Usable in accordance with installations standard IEC 62305
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE
• IEC EX/ATEX versions available

Technical data
General data
Nominal current IN at 25 °C 500 mA / 300 mA (EX Version)
Rated discharge current IN (8 / 20 µs) wire-wire / wire-PE / GND-PE - / 2.5 kA / -
1 3 Rated discharge current Imax (8 / 20 µs) wire-wire / wire-PE / GND-PE - / 10 kA / -
Response time wire-wire / wire-PE / GND-PE - / ≤ 2 ns / ≤ 100 ns
Volume resistivity per path 1.8 Ω ± 10%
Discharge current Itotal 10 kA
Rated discharge current Iimp (10 / 350 µs) 1 kA
2 4 Surge strength 4 kV / 2 kA, 10 repetitions
TS
Max. continuous voltage 1 A / 1 s, 5 repetitions
unprotected protected Overstressed fault mode Mode 2
VSSC4 SL Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
Rel. humidity 5%…96% RH
Degree of protection IP20
Ambient temperature (operational) -40 °C…+70 °C
1 3
Storage temperature -40 °C…+80 °C
Approvals UL, CSA pending
Clampable conductor
Connection Torx screw (T15) / slot (0.8 x 4.0)
Stripping length 7 mm
2 4
Tightening torque range 0.5 … 0.8 Nm
Solid / stranded 0.5 … 6 mm² / 0.5 … 4 mm²
TS Flexible / flexible with ferrule 0.5 … 2.5 mm²
unprotected protected
Dimensions
VSSC SL FG
Length x Width x Height mm 76 x 6.2 x 58.5
Note: end plate AP VSSC4: 1063120000
This is a graphical representation only.

Applications

0.8
Load current I [A]

0.6

0.4 0.4

0.2

0
-40 0 15 42.5 70

Ambient temperature T [°C]

28
Binary Digital Signal Protection | VARITECTOR SSC 4AN

Binary Digital Signal Protection


PRODUCT SELECTION

VARITECTOR SSC 4 SL and SL FG

Ordering data VSSC4 SL 12 V DC 0.5 A VSSC4 SL FG 12 V DC 0.5 A VSSC4 SL 24 V UC 0.5 A

Rated voltage UN 12 V DC 12 V DC 24 V AC / 34 V DC
Max. continuous voltage UC 15 V DC 15 V DC 30 V AC / 42 V DC
Voltage GND-PE - > 500 V -
Capacitance 4 nF 4 nF 650 pF
Gas discharge tube 90 V 90 V 90 V
Supressordiode UP 16 V 16 V 43 V
Limiting frequency (-3 dB) at load resistance 250 KHz 250 KHz 1.5 MHz
Protection level at
IN wire-wire / wire-PE / GND-PE - / 35 V / - - / 35 V / 1400 V - / 90 V / -
1 kV / µs wire-wire / wire-PE / GND-PE - / 30 V / - - / 30 V / 1400 V - / 70 V / -

Ordering data
Type VSSC4 SL 12VDC 0.5A VSSC4 SL FG 12VDC 0.5A VSSC4 SL 24VUC 0.5A
 Order No. 1063830000 1063880000 1063840000
Note

Ordering data VSSC4 SL FG 24 V UC 0.5 A VSSC4 SL 48 V UC 0.5 A VSSC4 SL FG 48 V UC 0.5 A

Rated voltage UN 24 V AC / 34 V DC 48 V AC / 68 V DC 48 V AC / 68 V DC
Max. continuous voltage UC 30 V AC / 42 V DC 60 V AC / 85 V DC 60 V AC / 85 V DC
Voltage GND-PE > 500 V - > 500 V
Capacitance 650 pF 450 pF 450 pF
Gas discharge tube 90 V 150 V 150 V
Supressordiode UP 43 V 91 V 91 V
Limiting frequency (-3 dB) at load resistance 1.5 MHz 2.2 MHz 2.2 MHz
Protection level at
IN wire-wire / wire-PE / GND-PE - / 90 V / 1400 V - / 200 V / - - / 200 V / 1200 V
1 kV / µs wire-wire / wire-PE / GND-PE - / 70 V / 1400 V - / 150 V / - - / 150 V / 1200 V

Ordering data
Type VSSC4 SL FG 24VUC 0.5A VSSC4 SL 48VUC 0.5A VSSC4 SL FG 48VUC 0.5A
 Order No. 1063890000 1063860000 1063910000
EX Version Type VSSC4 SL FG 24VUC EX VSSC4 SL FG 48VUC EX
 Order No. 1063930000 1063940000
Note

29
Binary Digital Signal Protection | VARITECTOR SSC 6AN
Binary Digital Signal Protection

VSSC 6AN SL and TR SL – protection for Imax 10kA


binary signals (SL) with disconnect lever
(TR) and indicator (LD)

Two-stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal-block format
• Modular width of just 6.2 mm
• Space saving design: 2 binary signals
• Torx® slotted screw connection
• Can be used to comply with the IEC 62305 installation Similar to Similar to Similar to
standard and the IEC 61643-1/-22 applications standards illustration illustration illustration
• Integrated PE contact in base element, safely discharges up
to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE
Technical data
General data
Nominal current 500 mA (see derating curve)
1 4 Dielectric strength at FG against PE –
Volume resistivity 1.8 Ω ± 10 %
Overstressed fault mode Mode 2
Requirement category acc. to IEC 61643-21 C2; C3; D1
Standards IEC 61643-21
Surge strength C2 2.5 kA
3 6 Surge strength D1 1 kA
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE – / 2.5 kA / –
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE – / 10 kA / –
Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE – / 1 kA / –
Storage temperature -40 °C...+80 °C
2 5
Ambient temperature (operational) -40 °C...+70 °C
TS Humidity 5...96 % RH
Degree of protection IP20
UNPROTECTED PROTECTED Flammability class V0
Connection data
VSSC 6 SLLD Connection Torx® screw T15 / slot 0.8 x 4
Tightening torque 0.5 Nm
Conductor cross section, flexible, ferrule (DIN 46228-1), max. 4 mm²
1 4
Conductor cross section, flexible, ferrule (DIN 46228-1), min. 0.5 mm²
Conductor cross section, solid, max. 6 mm²
Conductor cross section, solid, min. 0.5 mm²
Conductor cross section, stranded, Rated connection, max. 4 mm²
Conductor cross section, stranded, Rated connection, min. 0.5 mm²
Stripping length 10 mm
3 6
Mounting rail TS35
Dimensions
Length x width x height 88.5 x 6.1 x 81 mm

2 5
TS

UNPROTECTED PROTECTED

VSSC 6 TR SLLD
I/A Derating curve
1

0.8

0.6 0.6 0.6 0.6


0.5
0.4 0.4

0.2

0 TU
-40 ºC 0 ºC 15 ºC 42.5 ºC 70 ºC

Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000;
marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000
This is a graphical representation only.

30
Binary Digital Signal Protection | VARITECTOR SSC 6AN

Binary Digital Signal Protection


PRODUCT SELECTION

VSSC 6AN SL and TR SL

Technical data SL LD 12 V DC SL LD 24 V UC SL LD 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC/ 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 30 ms ≤ 30 ms ≤ 30 ms
Residual voltage UP ≤ 40 V ≤ 100 V ≤ 220 V
wire-wire / wire-PE / GND-PE - / 74 V / - - / 110 V / - - / 175 V / -
Protection level on output side sym.
Input 1 kV/µs, typ. - - -

Protection level on output side unsym.,


Input 1 kV/µs, typ. 74 V 110 V 175 V
Surge strength C3 10 A 50 A 50 A
Status indicator Yes Yes Yes
Ordering data
Type VSSC6 SL LD 12VDC 0.5A VSSC6 SL LD 24VUC 0.5A VSSC6 SL LD 48VUC 0.5A
 Order No. 1064340000 1064350000 1064360000
Note

Technical data TR SL LD 12 V DC TR SL LD 24 V UC TR SL LD 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC/ 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 30 ms ≤ 30 ms ≤ 30 ms
Residual voltage UP ≤ 40 V ≤ 100 V ≤ 220 V
wire-wire / wire-PE / GND-PE - / 74 V / - - / 110 V / - - / 175 V / -
Protection level on output side sym.
Input 1 kV/µs, typ. - - -

Protection level on output side unsym.,


Input 1 kV/µs, typ. 74 V 110 V 175 V
Surge strength C3 10 A 50 A 50 A
Disconnect lever Yes Yes Yes
Testing option Functional screw with test plug receptacle Functional screw with test plug receptacle Functional screw with test plug receptacle
connection 1, 2, 4, 5 connection 1, 2, 4, 5 connection 1, 2, 4, 5
Status indicator Yes Yes Yes
Ordering data
Type VSSC6 TR SL LD12Vdc0.5A VSSC6 TR SL LD 24VUC 0.5A VSSC6 TR SL LD 48VUC 0.5A
 Order No. 1064380000 1064390000 1064400000
Note

31
Binary Digital Signal Protection | VARITECTOR SSC 6AN

VSSC 6AN SLFG and TR SLFG – protection for


Binary Digital Signal Protection

binary signals (SL) with floating ground (FG), with and


without disconnect lever (TR) and indicator (LD) Imax 10kA

Two stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal block format
• Modular width of just 6.2 mm
• Space saving design: 2 binary signals
• Torx® slotted screw connection
• Can be used to comply with the IEC 62305 installation
standard and the IEC 61643-1/-22 applications standards
• Integrated PE contact in base element, safely discharges Similar to Similar to Similar to Similar to
up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE illustration illustration illustration illustration
• Version with floating ground PE connection used to avoid
differences in voltage potential
Technical data
General data
Dielectric strength at FG against PE ≥ 500 V
1 4 Volume resistivity 1.8 Ω ± 10 %
Overstressed fault mode Mode 2
Requirement category acc. to IEC 61643-21 C2; C3; D1
Standards IEC 61643-21
Surge strength C2 2.5 kA
3 6 Surge strength C3 10 A; 50 A @ 60 V
Surge strength D1 1 kA
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE – / 2.5 kA / 2.5 kA
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE – / 10 kA / 10 kA
Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE – / 10 kA / –
Storage temperature -40 °C...+80 °C
2 5
Ambient temperature (operational) -40 °C...+70 °C
TS
Humidity 5...96 % RH
Degree of protection IP20
UNPROTECTED PROTECTED Flammability class V0
VSSC 6 SLFG Connection data
Connection Torx® screw T15 / slot 0.8 x 4
Tightening torque 0.5 Nm
Conductor cross section, flexible, ferrule (DIN 46228-1), max. 4 mm²
1 4
Conductor cross section, flexible, ferrule (DIN 46228-1), min. 0.5 mm²
Conductor cross section, solid, max. 6 mm²
Conductor cross section, solid, min. 0.5 mm²
Conductor cross section, stranded, Rated connection, max. 4 mm²
Conductor cross section, stranded, Rated connection, min. 0.5 mm²
3 6 Stripping length 10 mm
Mounting rail TS35
Dimensions
Length x width x height 88.5 x 6.2 x 81 mm

2 5
TS

UNPROTECTED PROTECTED

VSSC 6 TR SLFGLD
I/A Derating curve
1

0.8

0.6 0.6 0.6 0.6


0.5
0.4 0.4

0.2

0 TU
-40 ºC 0 ºC 15 ºC 42.5 ºC 70 ºC

Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000;
marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000
This is a graphical representation only.

32
Binary Digital Signal Protection | VARITECTOR SSC 6AN

Binary Digital Signal Protection


PRODUCT SELECTION

VSSC 6AN SLFG and TR SLFG

Technical data SLFG LD 12 V DC SLFG LD 24 V UC SLFG LD 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 20 ms ≤ 20 ms ≤ 20 ms
Residual voltage UP ≤ 1600 V ≤ 1650 V ≤ 1550 V
wire-wire / wire-PE / GND-PE - / 74 V / 1400 V - / 110 V / 1400 V - / 175 V / 1200 V
Protection level on output side sym.
Input 1 kV/µs, typ. 30 V 70 V 150 V

Protection level on output side unsym.,


Input 1 kV/µs, typ. 74 V 110 V 175 V
Nominal current 500 mA 200 mA (IEC 61643-21) on request
Status indicator yes yes yes
Ordering data
Type VSSC6 SLFG 12VDC 0.5A VSSC6 SLFG 24VUC 0.5A VSSC6 SLFG 48VUC 0.5A
 Order No. 1064420000 1064430000 1064440000
Note

Technical data TR SLFG LD 12 V DC TR SLFG LD 24 V UC TR SLFG LD 48 V UC

Rated voltage AC/DC 12 V DC 24 V AC / 34 V DC 48 V AC / 68 V DC


Max. continuous voltage UC (AC) / (DC) 15 V DC 30 V AC / 42 V DC 60 V AC / 85 V DC
Signal transmission properties (-3 dB) ≤ 700 kHz ≤ 700 kHz ≤ 700 kHz
Pulse reset capacity ≤ 20 ms ≤ 20 ms ≤ 20 ms
Residual voltage UP ≤ 1600 V ≤ 1650 V ≤ 1550 V
wire-wire / wire-PE / GND-PE - / 74 V / 1400 V - / 110 V / 1400 V - / 175 V / 1200 V
Protection level on output side sym.
Input 1 kV/µs, typ. 30 V 70 V 150 V

Protection level on output side unsym.,


Input 1 kV/µs, typ. 74 V 110 V 175 V
Nominal current 500 mA 200 mA (IEC 61643-21) on request
Disconnect lever Yes Yes Yes
Testing option Functional screw with test plug receptacle Functional screw with test plug receptacle Functional screw with test plug receptacle
connection 1, 2, 4, 5 connection 1, 2, 4, 5 connection 1, 2, 4, 5
Status indicator Yes Yes Yes
Ordering data
Type VSSC6 TR SLFG LD 12VDC 0.5A VSSC6 TR SLFG LD 24VUC 0.5A VSSC6 TR SL FG LD 48VUC 0.5A
 Order No. 1064490000 1064500000 1064510000
Note

33
Other Communication Types | VARITECTOR SPC
Other Communication Types

VSPC RS485 Imax 10kA

For serial data transmission


• Optional monitoring function with status indicator and alert function
• Pluggable arrester (plug-in / disconnect interruption-free and impedance neutral)
• Low residual voltage
• Protection for conducted serial data transmission – RS485
• Testable with V-TEST instrument
• Integrated PE contact in base element, safely discharges up to 20 kA (8/20 μs)
and 2.5 kA (10/350 μs) to PE

Technical data
11 12 for all VSPC RS485
Dielectric strength with FG against PE > 500 V
7 8
Rated current 450 mA
Volume resistivity per path 2.2 Ω
GND 9 10 GND Overstressed fault mode Mode 2
3
TS
4 Requirement category acc. to IEC 61643-21 C1; C2; C3; D1
5 6 Surge strength C1 < 1 kA / 8/20 µs
Surge strength C2 5 kA / 8/20 µs
unprotected 1 2 protected Surge strength C3 100 A / 10/1000 µs
Complete module, direct earthing Surge strength D1 2.5 kA 10/350 µs
11 12
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / 2.5 kA
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 2 x 10 kA / 10 kA
7 8
Lightning test current, Iimp. (10/350 μs) wire-wire / wire-PE / GND-PE 0.2 kA / 2 x 0.2 kA / 0.2 kA
Type of connection Pluggable in VSPC BASE
GND 9 10 GND Storage temperature -40 °C…+80 °C
Ambient temperature (operational) -40 °C…+70 °C
OK FAULT
X2
X1
3
TS
4 Rel. humidity 5 %…96 % RH
5 6 Degree of protection IP20

unprotected 1 2 protected

Complete module, direct earthing, with remote alert

11 12

7 8

0.5
GND 9 10 GND
0.45

3 4 0.4
TS
5 6
0.35
Current [mA]

0.3
unprotected 1 2 protected

0.25
Complete module, indirect earthing
0.2

11 12
0.15

0.1
7 8
0.05

GND 9 10 GND 0
OK FAULT
X2 0 10 20 30 40 50 60 70 80 90 100
X1
Temperature [°C]
3 4
TS
5 6 Dimensions of complete module (arrester + base element) Without telecomm. contact With telecomm. contact (R)
Length x Width x Height mm 90 x 17.8 x 69 98 x 17.8 x 69
unprotected 1 2 protected
Note
Complete module, indirect earthing, with remote alert

This is a graphical representation only.

Base elements / base to arresters Ordering data for base


Type Qty. Order No.
Base element, direct earthing 1 8924710000
Base element, indirect earthing via spark gap (FG, floating ground) 1 8924270000
Base element, direct earthing with remote alert 1 8951790000
Base element, indirect earthing with remote alert 1 8951800000

Note: The basis elements are to be ordered separately VSPC Control unit must be used with remote
alert models PG 38.

34
Other Communication Types | VARITECTOR SPC

Other Communication Types


VSPC RS485 – arrester / plug-in elements

Ordering data VSPC RS485 2CH

Rated voltage (DC) 5 V DC


Max. continuous voltage, UC (DC) 6,4 V DC
Signaling contact UN 250 V AC 0,1 A 1CO at VSPC R
with VSPC CONTROL UNIT
Optical function indicator (VSPC R) green = OK; red = arrester faulty, replace
Transmission test (-3dB) 4 MHz
Impulse reset 20 ms
tested acc. to IEC61643-21
Residual voltage UP 35 V
wire-wire / wire-PE / GND-PE 15 V / 35 V / 500 V
Protection level on output side sym., input 1 kV/μs, typ. < 10 V
input 8/20 μs, typ. < 15 V
Protection level on output side unsym., input 1 kV/μs, typ. < 10 V
input 8/20 μs, typ. < 35 V

Ordering data
Without signaling contact / Function indicator Type VSPC RS485 2CH
 Order No. 8924670000
With signaling contact / Function indicator Type VSPC RS485 2CH R
 Order No. 8951670000
Note

35
Other Communication Types | VARITECTOR SSC 6AN
Other Communication Types

VSSC 6AN RS485, RS485 DP and RS232 – for interface signals Imax 10kA

Two-stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal block format
• Modular width of just 6.2 mm
• Space saving design
• Torx® slotted screw connection
• Can be used to comply with the IEC 62305 installation
standard and the IEC 61643-1/-22 applications standards
• Integrated PE contact in base element, safely discharges
up to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Similar to Similar to
• IEC EX/ATEX versions available illustration illustration

Technical data
General data
Nominal current 500 mA (see derating curve) / 300 mA (EX Version)
1 4 Volume resistivity 1.8 Ω ±10 %
Overstressed fault mode Mode 2
Requirement category to IEC 61643-21 C2, C3, D1
Standards IEC 61643-21
3 6 Surge strength C2 2.5 kA
Surge strength C3 10 A
Surge strength D1 0.5 kA
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / –
2 5 Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 10 kA / –
TS Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE 1 kA
Storage temperature -40 °C...+80 °C
UNPROTECTED PROTECTED
Ambient temperature (operational) -40 °C...+70 °C
Humidity 5...96 % RH
Degree of protection IP20
Flammability class V0
Connection data
1 4 Connection Torx® screw T15 / slot 0.8 x 4
Tightening torque 0.5 Nm
Conductor cross section, flexible, ferrule (DIN 46228-1), max. 4 mm²
Conductor cross section, flexible, ferrule (DIN 46228-1), min. 0.5 mm²
Conductor cross section, solid, max. 6 mm²
Conductor cross section, solid, min. 0.5 mm²
Conductor cross section, stranded, Rated connection, max. 4 mm²
3 6 Conductor cross section, stranded, Rated connection, min. 0.5 mm²
Stripping length 10 mm
Mounting rail TS35
Dimensions
Length x width x height 88.5 x 6.2 x 81 mm

2 5
TS Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000;
marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000
UNPROTECTED PROTECTED

I/A Derating curve Technical data RS485 RS232


1
Rated voltage AC/DC 12 V DC 12 V DC
0.8
Max. continuous voltage UC (DC) 15 V DC 15 V DC
0.6 0.6 0.6 0.6 Signal transmission properties (-3 dB) ≤ 2 MHz ≤ 2 MHz
0.5
Pulse reset capacity ≤ 20 ms ≤ 20 ms
0.4 0.4
Residual voltage UP ≤ 94 V ≤ 80 V
0.2 wire-wire / wire-PE / GND-PE 35 V / 35 V / - 70 V / 35 V / -
Protection level on output side sym.
0 TU Input 1 kV/µs, typ. 30 V 60 V
-40 ºC 0 ºC 15 ºC 42.5 ºC 70 ºC
Protection level on output side unsym.,
Input 1 kV/µs, typ. 94 V 80 V

Ordering data
Type VSSC6 RS485 VSSC6 RS232
 Order No. 1064980000 1064990000
EX Version Type VSSC6 RS485 EX
 Order No. 1065020000
This is a graphical representation only. Note

36
Other Communication Types | VARITECTOR SSC 6AN

Other Communication Types


VSSC 6AN RTD – for temperature signals Imax 10kA

Two-stage surge protection with screw connection for


instrumentation, control and automation technology
• Surge protection in terminal block format
• Modular width of just 6.2 mm
• Space saving design
• Torx® slotted screw connection
• Can be used to comply with the IEC 62305 installation
standard and the IEC 61643-1/-22 applications standards
• Integrated PE contact in base element, safely discharges up
to 20 kA (8/20 μs) and 2.5 kA (10/350 μs) to PE Similar to Similar to
• IEC EX/ATEX versions available illustration illustration

Technical data
General data
Nominal current 300 mA
1 4 Dielectric strength at FG against PE –
Volume resistivity 1.8 Ω ±10 %
Overstressed fault mode Mode 2
Requirement category acc. to IEC 61643-21 C2, C3, D1
Standards IEC 61643-21
Surge strength C2 2.5 kA 8/20 µs, 5 kV 1,2/50 µs
2 5 Surge strength C3 10 A 10/1000 µs
Surge strength D1 0.5 kA 10/350 µs
Rated discharge current IN (8/20 μs) wire-wire / wire-PE / GND-PE 2.5 kA / 2.5 kA / –
Rated discharge current Imax (8/20 μs) wire-wire / wire-PE / GND-PE 10 kA / 10 kA / –
Lightning test current, Iimp (10/350 μs) wire-wire / wire-PE / GND-PE 1 kA
Storage temperature -40 °C...+80 °C
Ambient temperature (operational) -40 °C...+70 °C
3 6 Humidity 5...96 % RH
TS Degree of protection IP20
Flammability class V0
Connection data
UNPROTECTED PROTECTED
Connection Torx® screw T15 / slot 0.8 x 4
Tightening torque 0.5 Nm
Conductor cross section, flexible, ferrule (DIN 46228-1), max. 4 mm²
Conductor cross section, flexible, ferrule (DIN 46228-1), min. 0.5 mm²
Conductor cross section, solid, max. 6 mm²
Conductor cross section, solid, min. 0.5 mm²
Conductor cross section, stranded, Rated connection, max. 4 mm²
Conductor cross section, stranded, Rated connection, min. 0.5 mm²
Stripping length 10 mm
Mounting rail TS35
Dimensions
Length x width x height 88.5 x 6.2x 81 mm

Accessories: Screwdriver: Torx® 9009170000, slotted 9008340000; test plug: PS 2.3 0180400000; EMC SET: 1067470000;
marker: WS 10/6 1818400000, DEK 6 0468560000, SNAPMARK 1805880000; end plate: 1063110000

Technical data RTD

Rated voltage AC/DC 1 V DC


Max. continuous voltage UC (DC) 5 V DC
Signal transmission properties (-3 dB) ≤ 1 MHz
Pulse reset capacity ≤ 20 ms
Residual voltage UP ≤ 126 V
wire-wire / wire-PE / GND-PE 15 V / 15 V / -
Protection level on output side sym.
Input 1 kV/µs, typ. 10 V

Protection level on output side unsym.,


Input 1 kV/µs, typ. 10 V

Ordering data
Type VSSC6 RTD
 Order No. 1139710000
EX Version Type VSSC6 RTD EX
 Order No. 1130670000
This is a graphical representation only. Note

37
Accessories | VARITECTOR SPC

VSPC CONTROL UNIT 24 V DC

• For monitoring up to 10 protective modules


• Signaling module for all VSPCs with status indicator
Accessories

• Signaling of cable breaks / signal interruptions


• Voltage supply from 18...31 V DC
• Potential-free changeover contact
• Function indicator (red/green LED)

Technical data
Input
Rated voltage (DC) 18 V…24 V DC…31 V DC
24 V X2 Rated current max. 50 mA
X1 Power rating 1.5 W
0V
Output
12 Current loop 8 mA bei < 51 V
11 Monitoring option 1…10 VSPC modules
VSPC CONTROL UNIT
14 Signal output
Type 1 CO contact
Max. switching voltage / continuous current 250 V / 1 A
Diagnostics
Operating status Green LED
Defect at current loop Red LED (control unit and defective module)
X2 X1 X2 X1 X2 X1 Wire breakage Red/green LED, flashing
nmax = 10 n=2 n=1 General data
VSPC...R VSPC...R VSPC...R Terminal rail TS35
Design, Protection class Insta-enclosure, IP20
Type of connection BL / SL
Storage temperature -40 °C…+80 °C
Ambient temperature (operational) -40 °C…+70 °C
Rel. humidity 5 %…96 % RH
Start-up time after fault correction 60 s

Dimensions
Length x Width x Height mm 102 x 18 x 71.5
Note
This is a graphical representation only.

Application Ordering data VSPC CONTROL UNIT 24 V DC


l ≤ 3 meter
Type VSPC CONTROL UNIT 24Vdc
 Order No. 8972270000
Note

n x VSPC...R
VSPC CONTROL UNIT
n ≤ 10

Status indication
LED green LED red Function
OK

FAULT (one/several
defect VSPC…R)
Wire break in
monitoring current
loop

38
Accessories | VARITECTOR SPC AND ACCESSORIES

VSPC accessories

V-Test
• Instrument for testing the protective functions of series:

Accessories
PU I, PU II and VSPC
• Device for realising standard IEC 62305 (periodic testing)
• Handy device with integrated battery set for local
measurements
• Result display via LCD display
• Bilingual menu
• Including protective bag and power supply
• Intuitive user navigation in German and English

The V-Test is a compact, portable instrument for the


Varitector SPC pluggable surge protection (VSPC series) and
surge protection for power distribution, PUI and II series.
With this instrument, the Weidmüller surge protection can be
tested for protective function in accordance with the required
test periods as stipulated by IEC62305 (DIN VDE 185 Part 3).
In a backlit display, the measurement result is indicated with
„ok“ or „not ok“ for each component.

Technical data Ordering data V-Test


Dimensions
Rated voltage 100...240 V AC Length x Width x Height mm 230 x 122 x 65
Accumulator set 8 NiMH with 2600 mA Ordering data
Storage temperature 0 °C ... 40 °C Type V-Test
Ambient temperature (operational) 0 °C ... 40 °C  Order No. 8951860000
Degree of protection IP20 Accessories Dimensions
Measuring range U < 1000 V / I = 1 mA Test Plug 2.3mm 0180400000
UL94 flammability class V0 Torx Screwdriver 0.8x4x100mm 9008340000

General tolerances of measurement range


Gas discharge tube +/- 10%
Varistor +/- 5%
TVS-diode +/- 5%

Note Note

Custom Print Identification System EMC Set

Ordering data Ordering data


Type Material Qty. Order No. Shield connection:
SNAPMARK 1 50 1805880000 Complete set - cable ties and shield connection
WS 10/5 144 1635010000 Cable ties
VSSC6 Side Labels Shield connection
WS 10/6 120 1818410000 Cable tie tool
VSPC Type Qty. Order No.
DEK 5/5 200 1609810000 EMC set 1 1067470000
EMC tie 100 1067490000
EMC connector 50 1067520000
Cable tie tool RT-1 1 1296000000
Note Note

39
Weidmüller – Partner in Industrial Connectivity.

As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
technological challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs.
Together we set standards in Industrial Connectivity.

For all Weidmüller Product Distibutors please visit www.weidmuller.com.au/au/distributors

Or contact your preferred supplier below:

Weidmüller Pty Ltd (Head Office)


43 Huntingwood Drive,
Huntingwood NSW 2148
Phone +61 (0) 2 9671 9999
Fax +61 (0) 2 9671 9900
Email info@weidmuller.com.au
www.weidmuller.com.au WAUS Surge Protection 2012-2013

Potrebbero piacerti anche