GONIOPHOTOMETER CONTROLLER
USER’S MANUAL
P185261TA8381116
Ver 1.00
Foreword
Notes:
l The contents of the manual may be amended without notice according to the
instrument’s improvement.
l
P185261TA8381116
Great effort has been made to assure the accuracy of the manual, please
contact us or our agents directly if any problem is found.
l If you have any different understanding to the manual, please refer to the
Technical Service Department of EVERFINE.
Please check the instrument carefully when you unpack the box for the first time.
If the instrument and related accessories are missing or appear abnormal, please
contact the dealer immediately.
Copyright Statement
The copyright of this manual and the related information belongs to EVERFINE,
and it is protected by the copyright law of People's Republic of China and other
relevant international treaties. Copying, modifying, spreading, excerpting, backing up
or translating the whole or part contents of this manual by any company or personnel
without the written permission of EVERFINE is prohibited. Otherwise it will be
treated as infringement and the infringer will assume law responsibility and all loss of
EVERFINE. Any infringement related above can be traced back to the responsible
user by the unique product number printed in the manual.
If EVERFINE has signed a written agreement with user and the contents in the
agreement are in conflict with above terms, the contents in the written agreement have
P185261TA8381116
Cautions
equipped for the wires in. Please pay special attention that the ground wire is well
grounded which differs from the null line.
Contents
Foreword........................................................................................................................ 1
Copyright Statement.......................................................................................................2
Cautions..........................................................................................................................3
Contents..........................................................................................................................4
Chapter 1 Overview....................................................................................................... 5
Chapter 2 Main Functions and Specifications................................................................6
2.1 Principle block and main functions...................................................................6
2.2 Main Specifications...........................................................................................6
Chapter 3 Software Operation........................................................................................7
P185261TA8381116
Chapter 1 Overview
Applicable Systems:
² EVERFINE GO-R5000 Goniophotometer System
² EVERFINE GO-2000 Goniophotometer System
² EVERFINE GO-HD5 Goniophotometer For Automatic and Signal Lights
P185261TA8381116
1. The angle of the two axes as well as the values of luminosity of each channel in
the equipped goniophotometer system is displayed on the screen.
2. The relative angular rotation of the goniophotometer system is controlled, so that
the angle can be set accurately depending on the current position.
3. Electrical parameter of digital power meter that is equipped with the
goniophotometer system is displayed.
4. The value of hygrothermograph that is equipped with the goniophotometer is
displayed.
5. High-speed communication with the test system is implemented by CAN bus,
and the measurement result is displayed simultaneously.
8. Menu: Click the relevant buttons to operate the software system (as shown in
Fig.5).
l A GO: Click to enter the interface of angle input (as shown in Fig.6). Press the
button “OK” after setting rotation angle and speed to rotate the axis. Press the
button “STOP” in the main interface (as shown in Fig.4) to stop rotating.
l A Reset: Click to reset the axis A directly, and press the button “STOP” in the
main interface (as shown in fig.4) to stop rotating.
l C GO: Click to enter the interface for angle input (as shown in Fig.6). Press the
button “OK” after setting rotation angle and speed, to rotate the axis C. Press the
button “STOP” in the main interface (as shown in Fig.4) to stop rotating.
l C Reset: Click to reset the axis C, and press the button “STOP” in the main
interface directly to stop rotating.
l Photometer: Click to enter the interface for photometer setup (as shown in Fig.7).
Activate one of the photometers firstly when there are multiple photometers.
Automatic or fixed measurement range can be set in this interface. Automatic
measurement range is preferred usually.
P185261TA8381116
l Photometer Setting: Click to this button, and dialogue of system setup appears
(as shown in Fig.8), where USB-CAN and language setting is completed.(Notice:
Please restart CT500_TouchPC after setting), as well as the setting of inching
rotation angle and time width of illuminance history data. If the inching rotation angle
is set with 1 degree, press the button “+” to rotate 1 degree and press “-“ to rotate 1
degree in the opposite direction. If the time width is set with 1 minute, the current
illuminance curve displayed is the one of the lately 1 minute.
l Blank Screen: Click to enter the blank screen mode to prevent measurement
accuracy affection caused by lights.
l Copyright: Click to display information about software version, copyright etc.
l Restart: Click to restart the computer and operation system.
l Shutdown: Click to shut down the computer automatically.
l Exit: Click to exit the software of CT500_TouchPC.
l Back: Click to return the main operation interface.