Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
March 2010
PIP PNF0200
Vents, Drains, and
Instrument Connection Details
PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES
In an effort to minimize the cost of process industry facilities, this Practice has been
prepared from the technical requirements in the existing standards of major industrial users,
contractors, or standards organizations. By harmonizing these technical requirements into a single
set of Practices, administrative, application, and engineering costs to both the purchaser and the
manufacturer should be reduced. While this Practice is expected to incorporate the majority of
requirements of most users, individual applications may involve requirements that will be appended
to and take precedence over this Practice. Determinations concerning fitness for purpose and
particular matters or application of the Practice to particular project or engineering situations should
not be made solely on information contained in these materials. The use of trade names from time
to time should not be viewed as an expression of preference but rather recognized as normal usage
in the trade. Other brands having the same specifications are equally correct and may be substituted
for those named. All Practices or guidelines are intended to be consistent with applicable laws and
regulations including OSHA requirements. To the extent these Practices or guidelines should
conflict with OSHA or other applicable laws or regulations, such laws or regulations must be
followed. Consult an appropriate professional before applying or acting on any material contained
in or suggested by the Practice.
© Process Industry Practices (PIP), Construction Industry Institute, The University of Texas at
Austin, 3925 West Braker Lane (R4500), Austin, Texas 78759. PIP Member Companies and
Subscribers may copy this Practice for their internal use. Changes or modifications of any kind are not
permitted within any PIP Practice without the express written authorization of PIP. Authorized Users
may attach addenda or overlays to clearly indicate modifications or exceptions to specific sections of
PIP Practices. Authorized Users may provide their clients, suppliers and contractors with copies of the
Practice solely for Authorized Users’ purposes. These purposes include but are not limited to the
procurement process (e.g., as attachments to requests for quotation/ purchase orders or requests for
proposals/contracts) and preparation and issue of design engineering deliverables for use on a specific
project by Authorized User’s client. PIP’s copyright notices must be clearly indicated and
unequivocally incorporated in documents where an Authorized User desires to provide any third party
with copies of the Practice.
PRINTING HISTORY
July 2001 Issued
March 2010 Complete Revision
PIP PNF0200
Vents, Drains, and
Instrument Connection Details
Table of Contents
1. Introduction................................. 5 PNF0305 - V/D-05 - Hydrostatic Test Vents
1.1 Purpose ............................................ 5 and Drains - Welded Piping - NPS 2 and Up
1.2 Scope ............................................... 5 with Threaded Pipets
2. References .................................. 5 PNF0306 - V/D-06 - Hydrostatic Test Vents
Process Industry Practices ...................... 5 and Drains - Welded Piping - NPS 3/4 –
1-1/2 with Lap Joint Flanges
3. Definitions ................................... 5
PNF0307 - V/D-07 - Hydrostatic Test Vents
4. Requirements.............................. 6 and Drains - Welded Piping - NPS 2 and Up
4.1 Coordination of Connections with Pipets and Lap Joint Flanges
and PIP Piping Material
Specifications ................................... 6 PNF0308 - V/D-08 - Hydrostatic Test Vents
4.2 Piping Material Take-Off .................. 9 and Drains - Welded Piping - NPS 3/4 –
4.3 Insulation and Pipe Nipple 1-1/2 with Weld Neck Flanges
Length .............................................. 9 PNF0309 - V/D-09 - Hydrostatic Test Vents
and Drains - Welded Piping - NPS 2 and Up
DRAWINGS with Weldolet and Flanges
PNF0301 V/D-01 - Hydrostatic Test Vents and PNF0310 - V/D-30 - Hydrostatic Test Vents
Drains - Threaded Piping - NPS 3/4 – 2 with and Drains - Plastic Lined Piping - NPS 1
Threaded Tees and Up with Blind Flanges
PNF0302 - V/D-02 - Hydrostatic Test Vents PNF0311 - V/D-31 - Hydrostatic Test Vents
and Drains - Socketweld Piping - NPS 3/4 – and Drains - 100% RT Piping - NPS 1 with
1-1/2 with Thredolets Blind Flanges
PNF0303 - V/D-03 - Hydrostatic Test Vents PNF0312 - V/D-32 - Hydrostatic Test Vents
and Drains - Socketweld Piping - NPS 3/4 – and Drains - 100% RT Piping - NPS 1-1/2 –
1-1/2 with Threaded Pipets 3 with Blind Flanges
PNF0304 - V/D-04 - Hydrostatic Test Vents PNF0313 - V/D-33 - Hydrostatic Test Vents
and Drains - Welded Piping - NPS 2 and Up and Drains - 100% RT Piping - NPS 4 and
with Thredolets Up with Blind Flanges
PNF0314 - V/D-46 - Hydrostatic Test Vents and PNF0408 - V/D-17 - Valved Vents and Drains -
Drains - Polypropylene Piping - NPS 8 and Welded Piping - NPS 2 and Up with
Up with Lapjoint Flange and Blind Flange Sockolet and Extended Body Valves
PNF0315 - V/D-45 - Hydrostatic Test Vents and PNF0409 - V/D-18 - Valved Vents and Drains -
Drains - Polypropylene Piping - NPS 3/4 – 6 Welded Piping - NPS 2 and Up with Plain
with Lapjoint Flange and Blind Flange End Nipolets
PNF0316 - V/D-43 - Hydrostatic Test Vents PNF0410 - V/D-19 - Valved Vents and Drains -
and Drains - PVC/CPVC Socketweld Piping Welded Piping - NPS 2 and Up with Plain
- NPS 3/4 and Up with Socketweld Flange End Nipple Pipets
and Blind Flange PNF0411 - V/D-20 - Double Valved Vents and
PNF0317 - V/D-49 - Hydrostatic Test Vents Drains - Socketweld Piping - NPS 3/4 –
and Drains - Socketweld Piping - NPS 3/4 – 1-1/2 with Socketweld Nipples
1-1/2 with Socketweld Flange and Blind PNF0412 - V/D-21 - Double Valved Vents and
Flange Drains - Socketweld Piping - NPS 3/4 –
PNF0318 - V/D-50 - Hydrostatic Test Vents 1-1/2 with Extended Body Valves
and Drains - Welded Piping - NPS 2 and Up PNF0413 - V/D-22 - Double Valved Vents and
with Socketweld Flange and Blind Flange Drains - Welded Piping - NPS 2 and Up
PNF0319 - V/D-53 - Hydrostatic Test Vents with Sockolet and Socketweld Nipples
and Drains - Welded Piping - NPS 2 and Up PNF0414 - V/D-23 - Double Valved Vents and
with Socketweld Flange and Blind Flange Drains - Welded Piping - NPS 2 and Up
PNF0320 - V/D-55 - Hydrostatic Test Vents with Sockolet and Extended Body Valves
and Drains - Tubing - OD 1/4" – 3/4" with PNF0415 - V/D-24 - Double Valved Vents and
Compression Fittings Drains - Welded Piping - NPS 2 and Up with
PNF0321 - V/D-57 - Hydrostatic Test Vents Plain End Nipolet and Socketweld Valves
and Drains - DI Piping - NPS 3 and Up with PNF0416 - V/D-25 - Valved Vents and Drains -
Mechanical Joints Welded Piping - NPS 3/4 – 1-1/2 with
PNF0401 - V/D-10 - Valved Vents and Drains - Lapjoint Flanges
Threaded Piping - NPS 3/4 – 2 with PNF0417 - V/D-26 - Valved Vents and Drains -
Threaded Nipples Welded Piping - NPS 2 and Up with
PNF0402 - V/D-11 - Valved Vents and Drains - Buttweld Pipet and Lapjoint Flanges
Welded Piping - NPS 3 and Up Thredolet PNF0418 - V/D-27 - Valved Vents and Drains -
and Threaded Nipples Welded Piping - NPS 3/4 – 1-1/2 with Weld
PNF0403 - V/D-12 - Valved Vents and Drains - Neck Flanges
Welded Piping - NPS 3 and Up with PNF0419 - V/D-28 - Valved Vents and Drains -
Threaded Nipolets Welded Piping - NPS 2 and Up with
PNF0404 - V/D-13 - Valved Vents and Drains - Weldolet and Weldneck Flanges
Socketweld Piping - NPS 3/4 – 1-1/2 with PNF0420 - V/D-29 - Valved Vents and Drains -
Socketweld Nipples Plastic Lined Piping - NPS 1 and Up with
PNF0405 - V/D-14 - Valved Vents and Drains - Instrument Tee Flange
Socketweld Piping - NPS 3/4 – 1-1/2 with PNF0421 - V/D-34 - Valved Vents and Drains -
Extended Body Valves Socketweld Piping - NPS 3/4 – 1-1/2 with
PNF0406 - V/D-15 - Valved Vents and Drains - Socketweld Nipple
Welded Piping - NPS 2 and Up with PNF0422 - V/D-35 - Valved Vents and Drains -
Sockolet and Socketweld Nipples Welded Piping - NPS 2 and Up with
PNF0407 - V/D-16 - Valved Vents and Drains - Socketweld Nipple
Welded Piping - NPS 2 and Up with PNF0423 - V/D-36 - Valved Vents and Drains -
Socketweld Pipet and Socketweld Nipples 100% RT Piping - NPS 1 with Weld Neck
Flange
PNF0424 - V/D-37 - Valved Vents and Drains - PNF0506 - P-06 - Pressure Connection -
100% RT Piping - NPS 1-1/2 – 3 with Weld Welded Piping - NPS 1-1/2 and Up with
Neck Flange Nipple Pipet
PNF0425 - V/D-38 - Valved Vents and Drains - PNF0507 - P-07 - Pressure Connection -
100% RT Piping - NPS 4 and Up with Weld Welded Piping - NPS 3/4 and Up with
Neck Flange Socketweld Double-Valved
PNF0426 - V/D-44 - Valved Vents and Drains - PNF0508 - P-08 - Pressure Connection -
Socketweld PVC/CPVC Piping - NPS 3/4 Welded Piping - NPS 3/4 and Up with
and Up with Socketweld Valve, Flange, and Socketweld, Double Extended Body Valves
Blind Flange PNF0509 - P-09 - Pressure Connection -
PNF0427 - V/D-47 - Valved Vents and Drains - Welded Piping - NPS 1-1/2 and Up with
Polypropylene Piping - NPS 3/4 – 6 with Nipolet, Double-Valved
Lapjoint Flange, Valve, and Blind Flange PNF0510 - P-10 - Pressure Connection -
PNF0428 - V/D-48 - Valved Vents and Drains - Welded Piping - NPS 1-1/2 and Up with
Polypropylene Piping - NPS 6 and Up with Nipple Pipet, Double-Valved
Lapjoint Flange, Valve, and Blind Flange PNF0511 - P-11 - Pressure Connection -
PNF0429 - V/D-51 - Valved Vents and Drains - Welded Piping - NPS 3/4 and Up with
Socketweld Pipe - NPS 3/4 – 1-1/2 with Lapjoint Flange
Socketweld Valve, Flange, and Blind PNF0512 - P-12 - Pressure Connection -
Flange Welded Piping - NPS 3/4 and Up with
PNF0430 - V/D-52 - Valved Vents and Drains - Weldneck Flange
Welded Pipe - NPS 2 and Up with PNF0513 - P-13 - Pressure Connection -
Socketweld Valve, Flange, and Blind Flange Plastic Lined Piping - NPS 1 and Up with
PNF0431 - V/D-54 - Valved Vents and Drains - Instrument Tee Flanged
Welded Pipe - NPS 2 and Up with PNF0514 - P-14 - Pressure Connection -
Socketweld Valve, Flange, and Blind Welded Piping - NPS 3/4 and Up with
Flange Socketweld Nipples
PNF0432 - V/D-56 - Valved Vents and Drains - PNF0515 - P-15 - Pressure Connection -
Tubing - OD 1/4" – 3/4" with Compression 100% RT Piping - NPS 1 with Weld Neck
Fittings Flange
PNF0433 - V/D-58 - Valved Vents and Drains - PNF0516 - P-16 - Pressure Connection -
DI Piping - NPS 3 and Up with Mechanical 100% RT Piping - NPS 1-1/2 – 3 with Weld
Joints Neck Flange
PNF0501 - P-01 - Pressure Connection - PNF0517 - P-17 - Pressure Connection -
Threaded Piping - NPS 3/4 and Up with 100% RT Piping - NPS 4 and Up with Weld
Threaded Tee or Thredolet Neck Flange
PNF0502 - P-02 - Pressure Connection - PNF0518 - P-18 - Pressure Connection -
Welded Piping - NPS 3/4 and Up with Welded Piping - NPS 3/4 and Up with
Socketweld Tee or Sockolet Lapjoint Flange and Flanged Valve
PNF0503 - P-03 - Pressure Connection - PNF0519 - P-19 - Pressure Connection -
Welded Piping - NPS 3/4 and Up with Socketweld PVC/CPVC Piping - NPS 3/4
Socketweld Tee or Socketweld Pipet and Up with Socketweld Flange and Valve
PNF0504 - P-04 - Pressure Connection - PNF0520 - P-20 - Pressure Connection -
Welded Piping - NPS 3/4 and Up with Polypropylene Piping - NPS 3/4 and Up
Socketweld Tee or Sockolet, with Extended with Lapjoint Flange and Flanged Valve
Body Valve
PNF0521 - P-21 - Pressure Connection -
PNF0505 - P-05 - Pressure Connection - Tubing - OD 1/4" – 3/4" with Compression
Welded Piping - NPS 1-1/2 and Up with Fittings
Nipolet
1. Introduction
1.1 Purpose
This Practice provides fabrication and installation details for piping vents, drains, and
instrumentation connections.
1.2 Scope
This Practice provides fabrication and installation details for the following types of
piping connections:
a. Hydrostatic Test Vents
b. Hydrostatic Test Drains
c. Valved Vents
d. Valved Drains
e. Pressure Connections
f. Thermowell Connections
g. Orifice Flange Tap Connections
Cross reference Table 1 is provided to relate the vent, drain, and instrument
connection details to associated PIP Piping Material Specifications.
2. References
Applicable parts of the following Practices shall be considered an integral part of this
Practice. The edition in effect on the date of contract award shall be used, except as otherwise
noted. Short titles will be used herein where appropriate.
3. Definitions
hydrostatic test vents and drains: Connections that are located at high points and low points
of piping systems for use during leak testing only. Hydrostatic test vent and drain connections
are shown on the detailed construction piping drawings and are provided as required based
upon the physical piping configuration. Hydrostatic test vent and drain connections are not
typically shown on the P&IDs. Hydrostatic test vent and drain connections are provided
without valves. Temporary valves are provided for leak tests as required. Closure devices
(i.e., plug, cap, or blind) are provided for permanent installation.
orifice flange tap connections: Valved connections for flow (differential pressure)
instruments
valved vents and drains: Connections that are located at high points and low points of piping
systems for use during operation and/or maintenance. Valved vent and drain connections are
shown on the P&IDs and detailed piping drawings, are always provided with valves and
closure devices (i.e., plug, cap, or blind), and are located to be accessible by operations or
maintenance personnel.
4. Requirements
09CM1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15CM1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01CS1B01 3/4 V/D-02 V/D-04 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
03CS1B01 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
12CS1B01 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
01CS1B02 3/4 V/D-02 V/D-04 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
12CS1G01 3/4 V/D-01 V/D-04 3/4 V/D-10 V/D-11 3/4 P-01 P-01 1 T-03 T-03 NA NA NA
01CS1S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
03CS1S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
06CS1S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09CS1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15CS1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01CS1S02 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
03CS1S02 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
12CS1T01 3/4 V/D-01 V/D-04 3/4 V/D-10 V/D-11 3/4 P-01 P-01 1 T-03 T-03 1/2 NA OR-01
03CS2B01 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
01CS2S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
03CS2S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
12CS2T01 3/4 V/D-01 V/D-04 3/4 V/D-10 V/D-11 3/4 P-01 P-01 1 T-03 T-03 1/2 NA OR-01
12LB0M01 3 NA V/D-57 3 NA V/D-58 3 NA P-22 3 NA T-26 NA NA NA
01LK0F01 1 V/D-30 V/D-30 1 V/D-29 V/D-29 1 P-13 P-13 1-1/2 T-17 T-17 1 NA OR-05
01LP0F01 1 V/D-30 V/D-30 1 V/D-29 V/D-29 1 P-13 P-13 1-1/2 T-17 T-17 1 NA OR-05
01LT0F01 1 V/D-30 V/D-30 1 V/D-29 V/D-29 1 P-13 P-13 1-1/2 T-17 T-17 1 NA OR-05
01SA0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SA0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
06SA0B01 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
01SA0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SA0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-22 T-22 1/2 NA OR-02
01SA0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
01SD0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SD0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SD0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-22 T-22 1/2 NA OR-02
01SD0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SD0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
01MZ0B01 3/4 V/D-06 V/D-07 3/4 V/D25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01NB0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03NB0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01NC0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03NC0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01NC0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03NC0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01NM0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03NM0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01NM0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03NM0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
06NM0B02 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
50NM0L01 1/4 - 3/4 V/D-55 NA 1/4 - 3/4 V/D-56 NA 1/4 - 3/4 P-21 NA 1/4 - 3/4 T-25 NA NA NA NA
50NM0L02 1/4 - 3/4 V/D-55 NA 1/4 - 3/4 V/D-56 NA 1/4 - 3/4 P-21 NA 1/4 - 3/4 T-25 NA NA NA NA
01NM0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03NM0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
01NU0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03NU0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01NU0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03NU0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
01PP0H01 3/4 V/D-45 V/D-46 3/4 V/D-47 V/D-48 3/4 P-20 P-20 1-1/2 T-24 T-24 NA NA NA
01PU0C01 3/4 V/D-43 V/D-43 3/4 V/D-44 V/D-44 3/4 P-19 P-19 1-1/2 T-23 T-23 NA NA NA
01PV0C01 3/4 V/D-43 V/D-43 3/4 V/D-44 V/D-44 3/4 P-19 P-19 1-1/2 T-23 T-23 NA NA NA
01SA0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SA0B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
06SA0B01 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
01SA0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SA0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
06SA0B02 3/4 V/D-08 V/D-09 3/4 V/D-27 V/D-28 3/4 P-12 P-12 1-1/2 T-15 T-15 1/2 NA OR-04
01SA0B03 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SA0B03 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01SA0B05 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SA0B05 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
06SA0B05 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
50SA0L01 1/4 - 3/4 V/D-55 NA 1/4 - 3/4 V/D-56 NA 1/4 - 3/4 P-21 NA 1/4 - 3/4 T-25 NA NA NA NA
50SA0L02 1/4 - 3/4 V/D-55 NA 1/4 - 3/4 V/D-56 NA 1/4 - 3/4 P-21 NA 1/4 - 3/4 T-25 NA NA NA NA
01SA0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SA0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-22 T-22 1/2 NA OR-02
09SA0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SA0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01SA0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
01SA0S03 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S03 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SA0S03 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
01SA0S04 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S04 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SA0S04 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SC0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SC0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09SC0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SC0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01SD0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SD0B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01SD0B03 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SD0B03 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
50SD0L01 1/4 - 3/4 V/D-55 NA 1/4 - 3/4 V/D-56 NA 1/4 - 3/4 P-21 NA 1/4 - 3/4 T-25 NA NA NA NA
50SD0L02 1/4 - 3/4 V/D-55 NA 1/4 - 3/4 V/D-56 NA 1/4 - 3/4 P-21 NA 1/4 - 3/4 T-25 NA NA NA NA
01SD0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SD0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SD0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-22 T-22 1/2 NA OR-02
09SD0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SD0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01SA0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SA0S02 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
01SD1B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
01SD1B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SD1B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SD1B01 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
03SD1B02 3/4 V/D-06 V/D-07 3/4 V/D-25 V/D-26 3/4 P-11 P-11 1-1/2 T-12 T-12 1/2 NA OR-03
06SJ0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09SJ0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SJ0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
06SJ1S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09SJ1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SJ1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
06SK0S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09SK0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SK0S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
06SK1S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09SK1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SK1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01SP1S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SP1S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
06SP1S01 3/4 V/D-02 V/D-04 3/4 V/D-13 V/D-15 3/4 P-02 P-02 1-1/2 T-09 T-09 1/2 NA OR-02
09SP1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
15SP1S01 3/4 V/D-02 V/D-04 3/4 V/D-20 V/D-22 3/4 P-07 P-07 1-1/2 T-09 T-09 3/4 NA OR-06
01SV0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02
03SV0S01 3/4 V/D-03 V/D-05 3/4 V/D-13 V/D-16 3/4 P-03 P-03 1-1/2 T-22 T-22 1/2 NA OR-02