MULTISTAGE STAINLESS STEEL

CENTRIFUGAL PUMP
GMAX Vertical Multistage in - line

1. Application :
The GMAX series is a multipurpose pump range
suitable for a variety of different applications
demanding reliable and cost efficient supply.

a. Thin, non-explosive liquids, not containing


solid particles. Handles various liquids from
portable water to industrial liquids within a
very wide temperature, flow and pressure
scales.

b.When pumping liquids with a higher density


(or) viscosity, the correction for the same has to
be done for capacity, head and power factors.

Usage

• Pressure boosting in high-rise buildings,


hotels etc.
• Municipal water supply and pressure boosting Check that the pump is not and will not be exposed to cavitation
• Boiler feed and condensate systems
• Washing plants and wash down b. Minimum inlet pressure - NPSH
• Irrigation and dewatering
• Domestic water supply Calculation of the inlet pressure "H" is
• Cooling water systems recommended when....
• Fire fighting
• the liquid temperature is high
• the flow is significantly higher than the
2. Codes : rated flow
• water is drawn from depths
• water is drawn through long pipes
Example • inlet conditions are poor

GV/H R S 2 - 2 0
GMAX Multistage Series. V - Vertical, H - Horizontal
50Hz only
60Hz only
Rated flow rate in M3 / hr
Number of stages X 10

3. Technical Data :
a. Liquid Temperature

Normal operating - Ambient


Liquid - Std Design - -15˚C to +90˚C
Hot water - -15˚C to +120˚C
Stainless Steel Centrifugal Pumps
To avoid cavitation, make sure that there is a Electrical Data
minimum pressure on the suction side of the
pump. The maximum suction lift "H" in Mounting Up to 4kW: V18
meters head can be calculated as follows Designation From 5.5 kW: V1
Insulation Class F
H = Pb X 10.2 - NPSH - Hf - Hv - Hs Efficiency class Eff.2
Eff.1 - on request
Pb = Barometric pressure in bar.
(Barometric pressure can be set to Enclosure class IP 55
1 bar.) In closed systems, Pb indicates IP 44 & IP 54 - on request
the system pressure in bar. 50Hz 3 x 200 - 220 / 346 - 380V,±10%
standard voltages 3 x 220 - 240 / 380 - 415V.
3 x 380 - 415 ∆V
NPSH = Net Positive Suction Head in meters
1 x 220-230 / 240 V
head.
(To be read from the NPSH curve at 60Hz 3 x 460 / 220 V.
the highest flow the pump will be standard voltages
delivering.)

Hf = Friction loss in suction pipe in meters Motor protection


head.
(At the highest flow the pump will Single phase motors have a built in thermal
be delivering). overload switch
Three phase motors must be connected to a
motor starter in accordance with local
Hv = Vapor pressure in meters head.
regulations
(To be read from the vapor pressure
Three phase motors from 3 kW and upwards
scale. “ Hv” depends on the liquid
have a built-in thermostat (PTC) according to
temperature "Tm")
DIN 44 082.

Hs = Safety margin = minimum 0.5 meters


head.
Ambient temperature
(To be read from the vapor pressure
scale. Maximum +40˚C
“ Hv” depends on the liquid If the ambient temperature exceeds +40˚C or
temperature “ Tm” ) if the motor is located 1000 meters above
sea level, the motor output (P2) must be
reduced due to the low density and
If the "H" calculated is positive, the pump can
consequently low cooling effect of the air. In
operate at a suction lift of maximum "H"
such cases, it may be necessary to use a
meters head.
motor with a higher output.

If the "H" calculated is negative, an inlet


pressure of minimum "H" meters head is P2

required. [%]

100

90

c. Motor 80

70

The motor is totally enclosed, fan-cooled, 2- 60

pole with principal dimensions in accordance 50

with the EN standards 20 25 30 35 40 45 50 55 60 65 70 75 80


t[˚C]
1000 2250 3500 m
Electrical tolerances according to EN 60034
Material
Pump components can be supplied in SS 304 (or) SS 316 (table given below)

3
7
5
2
1
11
10
9
8

4
6

Materials : GVR / GVS


Pos. Description Materials
1 Pump head Cast iron EN-GJL-200
2 Pump head cover Stainless steel 304
3 Shaft Stainless steel 304 (or) 316
4 Base Stainless steel 304 (or) 316
5 Shaft seal Mechanical
6 Base plate Cast iron EN-GJL-200
7 Rubber parts EDPM or FKM
8 Impeller Stainless steel 304 (or) 306
9 Chamber Stainless steel 304 (or) 306
10 Outer sleeve Stainless steel 304 (or) 306
11 O-ring for outer sleeve EDPM or FKM
* Stainless steel on request
GVR - 2
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a
density of 1Kg / dm3 and a kinetic viscosity of 20mm2/s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of 20 mm2/s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVR2 - 20 220 225 445 145 110 20
GVR2 - 30 238 225 463 145 110 20
GVR2- 40 256 225 481 145 110 20
GVR2 - 50 274 225 499 145 110 20
GVR2 - 60 297 225 522 145 110 25
GVR2 - 70 315 225 540 145 110 25
GVR2 - 90 351 245 596 170 150 30
GVR2 - 110 387 245 632 170 150 30
GVR2 - 130 440 245 685 170 150 35
GVR2 - 150 476 245 721 170 150 35
GVR2 - 180 530 265 795 180 155 40
GVR2 - 220 602 265 867 180 155 45
GVR2 - 260 682 290 972 180 155 50

SPECIFICATION
Motor Q
Model 3 1 1.2 1.6 2.0 2.4 2.8 3.2 3.5
(kW) (m /h)
GVR2 - 20 0.37 18 17 16 15 13 12 10 8
GVR2 - 30 0.37 27 26 24 22 20 18 15 12
GVR2 - 40 0.55 36 35 33 30 26 24 20 16
GVR2 - 50 0.55 45 43 40 37 33 30 24 20
GVR2 - 60 0.75 H 53 52 50 45 40 36 30 24
GVR2 - 70 0.75 (m) 63 61 57 52 47 41 35 28
GVR2 - 90 1.1 80 78 73 67 61 54 45 37
GVR2 - 110 1.1 98 95 89 82 73 64 54 44
GVR2 - 130 1.5 116 114 106 98 89 78 65 52
GVR2 -150 1.5 134 130 123 112 100 90 73 60
GVR2 - 180 2.2 161 157 148 136 121 108 91 76
GVR2 - 220 2.2 197 192 180 165 148 130 110 90
GVR2 - 260 3.0 232 228 214 198 179 158 130 110
GVR - 4
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of 20 mm2/s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVR4 - 20 235 225 460 145 110 20
GVR4 - 30 265 225 490 145 110 20
GVR4- 40 295 225 520 145 110 20
GVR4 - 50 325 245 570 170 150 20
GVR4 - 60 350 245 595 170 150 20
GVR4 - 70 420 245 665 170 150 25
GVR4 - 80 420 245 665 170 150 25
GVR4 - 100 475 265 740 170 150 30
GVR4 - 120 530 265 795 180 155 35
GVR4 - 140 645 290 935 180 155 35
GVR4 - 160 645 290 935 180 155 35
GVR4 - 190 725 325 1050 210 180 35
GVR4 - 220 805 325 1130 210 180 40

SPECIFICATION
Motor Q
Model 3 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0
(kW) (m /h)
GVR4 - 20 0.37 19 18 17 15 13 10 8 6
GVR4 - 30 0.55 28 27 26 24 20 18 13 10
GVR4 - 40 0.75 38 36 34 32 27 24 19 13
GVR4 - 50 1.1 47 45 43 40 34 31 23 17
GVR4 - 60 1.1 (H) 56 54 52 48 41 37 28 20
GVR4 - 70 1.1 (m) 66 63 61 56 48 43 33 24
GVR4 - 80 1.5 74 72 70 64 55 50 38 27
GVR4 - 100 2.2 96 90 87 81 71 62 48 34
GVR4 - 120 2.2 114 108 104 95 85 75 58 41
GVR4 -140 3.0 136 126 122 112 101 89 68 48
GVR4 - 160 3.0 152 144 140 129 115 101 78 55
GVR4 - 190 4.0 183 171 168 153 137 122 93 67
GVR4 - 220 4.0 211 200 192 178 160 138 108 79
GVR - 8
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVR8 - 20 /1 345 225 570 145 110 25
GVR8 - 20 350 225 575 145 110 25
GVR8 - 30 380 245 625 170 150 30
GVR8 - 40 420 245 665 170 150 30
GVR8 - 50 450 265 715 180 155 40
GVR8 - 60 480 265 745 180 155 40
GVR8 - 80 550 290 840 180 155 45
GVR8 - 100 610 325 935 210 180 55
GVR8 - 120 670 325 995 210 180 55
GVR8 - 140 750 380 1130 250 210 80
GVR8 - 160 810 380 1190 250 210 80
GVR8 - 180 870 380 1250 250 210 90
GVR8 - 200 930 380 1310 250 210 90

SPECIFICATION
Motor Q
Model 3 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0
(kW) (m /h)
GVR8 - 20 /1 0.75 10 9.5 9.3 9 8.5 8 7 6
GVR8 - 20 0.75 20 19.5 19 18 17 16 14 13
GVR8 - 30 1.1 30 29.5 28.5 27 25 24 21 19
GVR8 - 40 1.5 41 39.5 38 36 34 32 28 26
GVR8 - 50 2.2 H 52 50 48 45 42 40 36 32
GVR8 - 60 2.2 (m) 62 60 57 54 51 48 43 39
GVR8 - 80 3.0 83 80 77 73 69 65 58 52
GVR8 - 100 4.0 104 100 97 92 87 81 73 65
GVR8 - 120 4.0 124 120 116 111 104 97 87 78
GVR8 - 140 5.5 145 141 136 130 122 113 102 92
GVR8 - 160 5.5 166 161 156 148 139 130 118 106
GVR8 - 180 7.5 187 182 175 167 157 146 134 120
GVR8 - 200 7.5 208 202 195 186 175 163 150 135
GVR - 16
50Hz 2900rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 380 - 415 V, 50 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVR16 - 20 400 265 665 180 155 40
GVR16 - 30 455 290 745 180 155 50
GVR16 - 40 500 325 825 210 180 55
GVR16 - 50 565 380 945 250 210 70
GVR16 - 60 610 380 990 250 210 75
GVR16 - 70 655 380 1035 250 210 80
GVR16 - 80 700 380 1080 250 210 80
GVR16 - 100 820 490 1310 330 255 140
GVR16 - 120 910 490 1400 330 255 145
GVR16 - 140 1000 490 1490 330 255 160
GVR16 - 160 1090 490 1580 330 255 165

SPECIFICATION
Motor Q
Model 3 8 10 12 14 16 18 20 22
(kW) (m /h)
GVR16 - 20 0.75 27 26 25 24 22 21 19 16
GVR16 - 30 0.75 41 40 38 37 34 32 26 25
GVR16 - 40 1.1 54 53 52 49 46 43 38 34
GVR16 - 50 1.5 68 67 65 62 58 54 48 43
GVR16 - 60 2.2 H 82 80 78 74 70 64 58 52
GVR16 - 70 2.2 (m) 96 95 91 87 82 76 68 61
GVR16 - 80 3.0 110 108 104 99 94 86 77 70
GVR16 - 100 4.0 138 136 131 125 118 109 97 87
GVR16 - 120 4.0 166 162 157 150 141 130 116 105
GVR16 - 140 5.5 194 190 184 175 166 152 136 122
GVR16 - 160 5.5 222 217 210 200 189 174 156 140
GVS - 2
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVS2 - 20 220 225 445 145 110 20
GVS2 - 30 238 225 463 145 110 20
GVS2 - 40 256 245 519 170 150 25
GVS2 - 50 274 245 501 170 150 25
GVS2 - 60 297 245 542 170 150 25
GVS2 - 70 325 245 570 170 150 30
GVS2 - 90 361 265 590 180 155 35
GVS2 - 110 397 265 662 180 155 35
GVS2 - 130 450 290 740 180 155 40
GVS2 - 150 486 290 776 180 155 40
GVS2 - 180 540 325 865 210 180 45

SPECIFICATION
Motor Q
Model 3 1 1.5 2 2.5 3 3.5 4 4.5
(kW) (m /h)
GVS2- 20 0.55 26 24 22 21 19 16 12 9
GVS2 - 30 0.75 39 36 34 31 27 24 19 15
GVS2 - 40 1.1 52 48 45 42 36 32 26 20
GVS2 - 50 1.1 H 65 61 57 52 46 41 33 25
GVS2 - 60 1.1 (m) 78 74 69 63 56 49 40 30
GVS2 - 70 1.5 92 86 81 74 66 57 47 35
GVS2 - 90 2.2 118 111 104 95 86 76 61 45
GVS2 - 110 2.2 144 137 128 117 106 91 75 55
GVS2 - 130 3.0 171 163 152 139 126 108 90 66
GVS2 - 150 3.0 198 188 176 161 146 125 104 77
GVS2 - 180 4.0 238 228 212 195 175 151 126 94
GVS - 4
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of
20 mm2 /s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVS4 - 20 241 225 466 145 110 20
GVS4 - 30 271 245 516 170 150 20
GVS4 - 40 312 245 557 170 150 25
GVS4 - 50 340 265 605 170 150 30
GVS4 - 60 367 265 632 170 150 35
GVS4 - 70 429 290 179 180 155 40
GVS4 - 80 429 290 719 180 155 40
GVS4 - 100 482 325 807 210 180 45
GVS4 - 120 536 325 861 210 180 45
GVS4 - 140 665 380 1045 250 210 70
GVS4 - 160 665 380 1045 250 210 70

SPECIFICATION
Motor Q
Model 3 2.5 3 4 5 6 7 8 9
(kW) (m /h)
GVS4 - 20 0.75 26 25 23 21 19 16 14 11
GVS4 - 30 1.1 40 39 36 32 30 26 22 18
GVS4 - 40 1.5 53 52 48 44 41 35 31 24
GVS4 - 50 2.2 H 66 65 60 55 51 44 39 30
GVS4 - 60 2.2 (m) 80 78 73 67 61 54 47 36
GVS4 - 70 3 93 91 85 78 71 63 55 42
GVS4 - 80 3 107 104 97 90 82 73 63 49
GVS4 - 100 4 134 130 121 113 103 92 80 61
GVS4 - 120 4 161 156 145 136 125 111 96 74
GVS4 - 140 5.5 188 183 170 159 146 130 112 86
GVS4 - 160 5.5 215 210 196 183 168 149 128 99
GVS - 8
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a density
of 1Kg / dm3 and a kinetic viscosity of 20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a density
of 1kg/dm3 and a kinetic viscosity of 20 mm2 /s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVS8 - 20/1 350 225 575 145 110 25
GVS8 - 20 360 245 605 170 150 30
GVS8 - 30 390 265 655 180 155 35
GVS8 - 40 430 290 720 180 155 40
GVS8 - 50 460 290 750 180 155 45
GVS8 - 60 490 325 815 210 155 50
GVS8 - 80 570 380 950 250 180 75
GVS8 - 100 630 380 1010 250 210 85
GVS8 - 120 690 380 1070 250 210 85
GVS8 - 140 780 490 1270 330 255 130

SPECIFICATION
Motor Q
Model 3 7 8 9 10 11 12 13 14
(kW) (m /h)
GVS8- 20/1 0.75 13 12 11.5 11 10.5 10 9.5 9
GVS8 - 20 1.5 27 26 25 24 23 22 20 18
GVS8 - 30 2.2 41 40 38 37 35 33 31 28
GVS8 - 40 3 55 54 52 50 47 45 42 38
GVS8 - 50 3 H 70 68 65 63 59 56 52 48
GVS8 - 60 4 (m) 85 82 78 76 72 68 63 58
GVS8 - 80 5.5 115 111 105 101 97 91 85 78
GVS8 - 100 7.5 145 140 132 126 122 115 107 98
GVS8 - 120 7.5 175 169 160 152 148 139 129 118
GVS8 - 140 11 205 198 188 179 174 163 152 139
GVS - 16
60Hz 3500rpm
1. Curves as per ISO2548C / DIN1944 / III
2. Head and power ratings apply to media with a
density of 1Kg / dm3 and a kinetic viscosity of
20mm2 / s
3. The operation of pump shall refer to the scope of
performance of the black curve to prevent danger
due to overheating
4. Electrical tolerance according to EN 60034
5. Check that the pump is not and will not be
exposed to cavitation
6. Electrical data: 3 x 440, 60 Hz.
7. Measurements have been made with airless water
at temp. of 20˚C
8. Head and power ratings apply to media with a
density of 1kg/dm3 and a kinetic viscosity of
20 mm2 /s.

DIMENSION AND WEIGHT


Size (mm) Weight
Model
B1 B2 B1+B2 D1 D2 (Kg.)
GVS16 - 20/1 400 265 665 180 155 40
GVS16 - 20 410 325 735 210 180 50
GVS16 - 30 475 380 855 250 210 70
GVS16 - 40 520 380 900 250 210 80
GVS16 - 50 595 490 1085 330 255 140
GVS16 - 60 640 490 1130 330 255 145
GVS16 - 70 685 490 1175 330 255 160
GVS16 - 80 730 490 1220 330 255 160
GVS16 - 100 820 535 1355 330 255 190

SPECIFICATION
Motor Q
Model 3 10 12 14 16 18 20 22 24 26
(kW) (m /h)
GVS16 - 20/1 2.2 19 18.5 18 17 16 15 14 13 11
GVS16 - 20 4 38 37.5 37 36 34 32 30 27 24
GVS16 - 30 5.5 57 56 55 54 51 48 45 40 36
GVS16 - 40 7.5 H 76 75 73 72 68 64 60 54 49
GVS16 - 50 11 (m) 96 94 92 90 85 80 75 68 62
GVS16 - 60 11 115 113 111 108 102 96 91 82 75
GVS16 - 70 15 135 132 129 126 119 113 106 96 88
GVS16 - 80 15 155 152 148 144 137 130 122 111 101
GVS16 - 100 18.5 197 192 187 181 174 165 153 141 127
M U LT I S T A G E S T A I N L E S S S T E E L C E N T R I F U G A L P U M P