FOX612 & FOX615 technical data

Universal multiservice platform

FOXMAN-UN network management system Type tests


Electromagnetic compatibility
EMC ETSI EN 300386 V1.5.1

power supply
IEC 61000–6–2, EN 61000–6–2
3 x 10/100/1000 BaseT
GbE IEC 61000–6–4, EN 61000-6–4
power supply
GbE
2 x GbE / 10 GbE SFP
12 x alarm input IEC TS 61000–6–5
8 x 2 Mbps
1 x LCT Port IEEE 1613
CESM1 2 x alarm output

System Control Emission EN 55022

2 x 2 Mhz / 120 Ω synch in


Immunity IEC 61000–4–2, EN 61000–4–2
2 x 2 Mhz / 120 Ω synch out IEC 61000–4–3, EN 61000–4–3
IEC 61000–4–4, EN 61000–4–4
64 x 2 Mbps 2 x STM- 4/16 SFP IEC 61000–4–5, EN 61000–4–5
GbE SAMO2 2 x STM-1/4 SFP
TDM transport
GbE 4 x 10/100/1000 BaseT IEC 61000–4–6, EN 61000–4–6
IEC 61000–4–16, EN 61000–4–16
64 x 2 Mbps 2 x STM-1/4 SFP IEC 61000–4–17, EN 61000–4–17
GbE
SAMO1 2 x STM-1 SFP
GbE
TDM transport 4 x 10/100/1000 BaseT IEC 61000–4–18, EN 61000–4–18
Shock and vibration IEC 60 721–3–3, class 3M1
IEC 60 721–3–2, class 2M1
Ambient conditions
Distance protection relay Storage ETS 300 019–1–1, class 1.2
4 x protection command
TEPI1 16 x binary signal input Temperature range - 40°C … + 70°C
4 x 2 Mbps 8 x binary signal output
Distance protection
6 x auxiliary relay
Humidity Clima diagram class 1.2

Transport ETS 300 019–1–2, class 2.2


Differential protection relay
4 x IEEE C37.94
4 x 2 Mbps OPIC1 Temperature range - 40°C … + 70°C
Differential protection or ABB proprietary
Humidity Clima diagram class 2.2
Operation ETS 300 019–1–3, class 3.2
8 x 64 Kbps
4 x 2 Mbps LECO1 Temperature range - 25°C … + 60°C
Data access G.703 Fanless variant - 25°C … + 55°C
Startup temperature - 25°C
Humidity max 95%, non-condensing
V.24 / V.28
3 2 x 2 Mbps LEDS1 4 x programmable interface X.24 / V.11 Clima diagram class 3.2
Data access 1 x 10/100 BaseT V.35
RS-485 2-/ 4-wire SFP overview (other types available on request)
TDM bus 128 x 2 Mbps

SAMO1 SAMO2 ETOP1 CESM1


Gigabit Ethernet star

Gigabit Ethernet star

16 x voice 2-wire a/b


4 x 2 Mbps LESU1 STM-1 electrical x x
Voice subscriber Q.552
S-1.1 x x
Telephony exchange
L-1.1 x x
12 x voice 2-wire a/b
4 x 2 Mbps LEXI1 L-1.2 x x
Voice exchange G.711
X-1.2 x x
U-1.2 x x
8 x voice
4 x 2 Mbps LEDA1 CWDM x x
Data access Available interfaces:
2/4-wire E&M
1 x 1-pair 1x n x 64 kbit/s (n = 1-32) S-4.1 x x
DTM-M
Desktop 1 x IF - G.703 / G.704, V.24 /
1 x 2-pair X.21/ V.11 / V.35 / V.36 L-4.1 x x
8 x 1pair / 4 x 2pair SHDSL - 10/100 BaseT
8 x 2 Mbps DATI1 Max. 2 x REG L-4.2 x x
DSL SHDSL
1 x 1-pair 1 x 1-pair X-4.2 x x
REG V-4.2 x x
1 x 2-pair 1 x 2-pair
SHDSL SHDSL
S-16.1 x
L-16.1 x
8 x 1-pair
STICx / DATI1
4 x 2-pair SHDSL module L-16.2 x
V-16.2 x

8 x 2 Mbps
U-16.2 x
8 x 2 Mbps LEDE1
Data access G.703 / G.704 1000 BASE-SX x x
1000 BASE-LX x x

8 x 2 Mbps 8 x 2 Mbps
1000 BASE-TX x x
GbE *CEPI1
GbE Circuit emulation G.703 / G.704 1000 BASE-EX x x
1000 BASE-ZX x x

3 2 x 2 Mbps
10 GBASE-LR x
GbE *COSI1
GbE Voice over IP Main FOXMAN-UN network management system features
© ABB Switzerland Ltd, October 2013. The right to modifications or deviations due to technical progress is reserved.

Full-featured management system for various ABB communication equipment including


1 6 x 2 Mbps
EPSI1 FOX615/612, FOX515/512, FOX660 and legacy FOX-U
GbE 4 x 10/100 BaseT
GbE L2 / L3 Ethernet
– Supervision of communication network
32 x SHDSL
*DEFM1 GbE – Graphical network display with comprehensive fault management
Ethernet First Mile DSL GbE – Alarm list
– Event list
ELET1
GbE – Configuration management
24 x 10/100/1000 BaseT
L2 Ethernet GbE
– Full configuration of network elements
– Backup of configurations
ETOP1 GbE – Security management
12 x GbE SFP
L2 Ethernet GbE – Performance management as per ITU-T G.826
– End to end trail handling
EPOI1 GbE
1KHA - 001 212 - SEN - 10.13 - Printed in Switzerland

12 x 10/100/1000 BaseT PoE


L2 Ethernet GbE
TDM transport Protection Circuit emulation
modules modules modules
(DEFM1, CEPI1, COSI1 available in 2014)

Data / voice Core Ethernet


modules modules modules

DSL
Chassis switch modules modules

www.abb.com/communicationnetworks
Technical data of FOX612 & FOX615

Most used SFPs also available: CWDM, DWDM; single-fiber, electrical signal

Main characteristics Tributary modules (RJ45) (e.g. electrical GbE)


Optical SFP for STM-1 ports S-1.1 L-1.1 L-1.2 CWDM CWDM
X-1.2 U-1.2
Application Utility-grade multiservice multiplexer for com- PDH E1 modules Teleprotection modules Wavelength nm 1310 1310 1550 1550 1550
munication using optical and SHDSL networks OPIC1 differential protection
LEDE1 E1 G.703
Architecture Modular design with connectivity on backplane Min. output power Tx dBm -15 -5 -5 0 5
Number of electrical ports 8 x E1 acc. G.703/G.704 Number of protection ports 4 x differential protection ports with SFP cages for:
for hot-pluggable modules MM SFP 850 nm, LC/PC
Bit rate 2048 kbit/s ± 50 ppm Guaranteed sensitivity Rx dBm -28 -34 -34 -35 -45
Backplane connection TDM bus, Ethernet star SM SFP 1310 nm, LC/PC
Line impedance 75 Ω asymmetrical or 120 Ω symmetrical Attenuation range EoL dB 13 29 29 35 50
TDM cross connect (DXC) Non-blocking Bit rate Line-rate 2048 kbit/s acc. ITU-T G.704
Traffic protection SNCP on 64 kbit/s and P12 layer for transparent E1 IEEE C37.94 payload 63 - 768 kbit/s (1 - 12 time Max. receiving power dBm -8 -8 -10 -3 -10
PDH 128 x 2 Mbit/s, granularity 64 kbit/s
channels slots) Optical SFP for STM-4 ports S-4.1 L-4.1 L-4.2 CWDM CWDM
SDH VC-12, VC-3, VC-4 ABB TPE payload 64 – 192 kbit/s (1 – 3 time slots) X-4.2 V-4.2
Features Tributary or aggregate interface
Ethernet crossbar Protection features Standardized IEEE C37.94 connection to Wavelength nm 1310 1310 1550 1550 1550
Capacity Distributed switching architecture with centralised Circuit emulation modules protection relays
64 Gbps switching fabric for intermodule switching Proprietary SFC-protocol connection to ABB Min. output power Tx dBm -15 -3 -3 1 1
*CEPI1 CESoP / E1 G.703 Guaranteed sensitivity Rx dBm -28 -28 -28 -29 -37
Communication technology PDH, SDH, IP/Ethernet, EoS, CES Traffic protection 1+1 path protection, bidirectional switching
Number of electrical ports 8 x E1 acc. G.703/G.704 Attenuation range EoL dB 13 25 25 30 38
Equipment protection TEPI1 distance protection
Bit rate 2048 kbit/s ± 50 ppm Max. receiving power dBm -8 -8 -8 -8 -9
1+1 HW Protection CESM1 (Warm standby) Number of protection ports 4 x protection commands
LEDA1, LEDS1, EPSI1 (VRRP), SAMO2, Line impedance 75 Ω asymmetrical or 120 Ω symmetrical
Connector Terminal block for direct wiring Optical SFP for STM-16 ports S-16.1 L-16.1 L-16.2 V-16.2 U-16.2
LEDE1 (Combiner), CEPI1 (Combiner) Features Circuit emulation using SAToP acc. IETF PWE3 for
Traffic protection 64 kbit/s and P12 layer Protection voltage 24 VDC … 250 VDC, programmable
Up to 8 P12 signals over packet Protection functions Protection link addressing Wavelength nm 1310 1310 1550 1550 1550
1+1 path protection n x 64 kbit/s TEPI1, OPIC1, LEDA1, LEDS1, LECO1, LESU1
Supervision of transmission time Min. output power Tx dBm -5 -5 -2 1 5
SNCP (VC-12, VC-3, VC-4) SAMO1, SAMO2, LEDE1
VolP telephony modules Logical combinations (OR, AND) for T-off
MSP (STM-1, STM-4, STM-16) SAMO1, SAMO2 Command drop & insert Guaranteed sensitivity Rx dBm -18 -18 -28 -30 -30
*COSI1 Event recorder
LAG CESM1 Attenuation range EoL dB 13 13 26 31 35
Number of ports Up to 912 PSTN subscribers (no physical ports) IRIG-B time stamping
RSTP, MSTP Chassis switch Aux. relay outputs Max. receiving power dBm 0 -9 -9 -9 -9
Features SIP gateway for voice over IP of PSTN ports
Aggregation bit rates Codec G.711 and G.729A support including silence Traffic protection 1+1 path protection, typically 3.5 ms switch-over Optical SFP for Ethernet ports 1000 1000 1000 1000 1000
SDH Feature: STM-1, STM-4, STM-16 supression. time BASE- BASE- BASE- BASE- GBASE-
Ethernet GbE, 10 GbE Fax service acc. T.38, DTMF acc. RFC 2833, Number of auxiliary ports 16 x binary signal input SX (MM) LX EX ZX LR
SHDSL, net capacity n x 64 kbit/s or 2 Mbit/s (n = 3 ... 32) SIP authentication acc. RFC 2617
8 x binary signal outputs Wavelength nm 850 1310 1310 1550 1310
Power supply
Data access modules Auxiliary power supply 24 VDC onboard Typical distance km 0,5 5 40 70 10
Input voltage range 48 VDC, 60 VDC or external power converter
- 39.5 VDC … - 72 VDC LEDS1 Auxiliary signal functions Logical combinations (OR, AND)
Alarm card functionality for 3rd party equipment
Max. input current 30 A (FOX615) Number of legacy data ports 4 x V.11/X.24, V.35, V24/V.28
(ALCAR)
16 A (FOX612) RS-485 (2-wire and 4-wire)
Hardware protection 1+1, hot standby Options 1+1 path protection
Subrate 64 kbit/s (future release) SHDSL modules Abbreviations
Standardization
Point-multipoint, multipoint-multipoint data confer- DATI1
PDH / SDH ITU-T G.702, G.703, G.704, G.706 encing with 4, 8 or 16 participants
G.707, G.7041, G.7042 Number of SHDSL interfaces 8 x 1-pair or 4 x 2-pair CAS Channel-Associated Signalling
Performance monitoring acc. ITU-T G.826
G.711 - G.715, G.732, G.736, G.737 Line code 16 Trellis coded-PAM according G.991.2 CES Circuit Emulation Service
Traffic protection 1+1 path protection, shared protection ring
G.742, G.821, G.823, G.826 Line rate n x 64 kbit/s duplex via 1 or 2 copper pair, CESoP Circuit Emulation Services over Packet
Equipment protection 1+1 HW protection for data conferences
Optical parameters G.692, G.694.1, G.694.2, G.957 n = 3 ... 32 CMI Code Mark Inversion
Data interface compatibility UNIDA, DATAx, DATI1 / DTM-M
Ethernet IEEE 802.1D, 802.1Q, 802.1p, 802.15, 802.39d Service rate n x 64 kbit/s duplex via 1 or 2 copper pair, CWDM Coarse Wavelength Division Multiplexing
Bit rate 0 … 600 kbit/s, oversampling for V.11 / X.24, V.35,
802.1w, 802.3af, 802.3at, 802.3z, 802.1s, 802.3ad n = 1 ... 32
RFC 2328, RFC 2453, 802.1ad RS-485 DCN Data Communication Network
Transmission range Up to 25 km
0 ... 96 kbit/s: oversampling for V.24/V.28 DSL Digital Subscriber Line
Safety IEC 60950–1, EN 60950–1 Transmission mode 1 pair or 2 pair (cable depending)
For all interface types:
IEC 60825 CWDM Coarse Wavelength Division Multiplexing
0.6 … 38.4 kbit/s, a-/synchronous Traffic protection 1+1 path protection
Mechanical dimensions FOX615 48, 56, 64 kbit/s, synchronous DSL Digital Subscriber Line
Features Point-multipoint
Shelf with front cover (WxHxD) 465 x 309 x 304 mm Ethernet port 1 x 10/100 BaseT Tributary or aggregate interface DTMF Dual-Tone Multi-Frequency
Cable tray (WxHxD) 465 x 89 x 240 mm RJ45 electrical Remote powering DWDM Dense Wavelength Division Multiplexing
Heat deflection shield (WxHxD) 465 x 89 x 237 mm, optional Ethernet features Bridge over PDH functionality *DEFM1 Ethernet first mile DXC Digital Cross Connect
PPP, HDLC encapsulation
Number of mechanical slots 21, incl. 1 (2) for CESM1 Number of SHDSL interfaces 32 x 1-pair or pair bonding up to 4 pairs ECC Embedded Communication Channel
Ethernet interface compatibility ETER1, EPSI1, LAWA4, OPTIF, DATAx
Mechanical dimensions FOX612 DATI1 / STICx / DTM-M Line code 16 Trellis coded-PAM according G.991.2 EMC Electro Magnetic Compatibility
Shelf with front cover (WxHxD) 465 x 176 x 304 mm Line rates TCPAM-16: EoL End of Life
and fan unit n = 3 ... 60 x 64 Kbps (3840 Kbps) per pair EoS Ethernet over SDH
LECO1 64 kbit/s G.703
Number of mechanical slots 8, incl. 1 (2) for CESM1 TCPAM-32:
Number of ports 8 x 64 Kbps according to ITU-T G.703 n = 12... 89 x 64 Kbps (max. 5696 Kbps) per FE Fast Ethernet
Bit rate 64 kbit/s codirectional pair FXS Foreign eXchange Station

Core modules Traffic protection 1+1 path protection Transmission range Up to 25 km GbE Gigabit Ethernet
Features Member of chassis switch GFP Generic Framing Procedure
Ethernet switching and routing modules PPPoE HDLC High-Level Data Link Control
CESM1 control unit ELET1 L1/L2 Ethernet
Remote desktop modules IF InterFace
Management interfaces 10/100/1000 BaseT (IEEE 802.3) Number of physical ports 24 x 10/100/1000 BaseT, RJ45 connector
DTM-M SHDSL desktop IP Internet Protocol
DCC-interfaces Features Member of chassis switch
Number of transmission ports 1 x 1-pair or 2-pair LAG Link Aggregation
Synch I/O 2048 kHz: 2 synch inputs, 2 synch outputs Two-slot unit
Number of access ports fixed G.703/G.704 120 Ω or 1 modular inter- LCAS Link Capacity Adjustment Scheme
Alarm I/O 12 alarm inputs, 2 alarm relay outputs Traffic protection Chassis switch features
face (G.703/G.704 75 Ω, V.24, X.21/V.11, V.35, LT Line Termination
Main features Central processing unit, DCN IP routing, Ethernet ETOP1 L1/L2 Ethernet V.36, Ethernet) LTP Linear Trail Protection
crossbar, Ethernet aggregation Number of physical ports 12 x GbE, SFP based Line code 16 Trellis coded-PAM according G.991.2 MCAS Mercury-CAS
1+1 equipment protection, (warm standby)
Line rate n x 64 kbit/s duplex via 1 or 2 copper pair,
Number of Ethernet ports 3 x 10/100/1000 BaseT MCMI Modified Code Mark Inversion
Features Member of chassis switch n = 3 ... 32
2 x GbE/10 GbE, SFP + based MIB Management Information Base
Traffic protection Chassis switch features Service rate n x 64 kbit/s duplex via 1 or 2 copper pair,
1 x LCT Port
EPOI1 L2 Ethernet with PoE n = 1 ... 32 MLPPP Multi Link Point to Point Protocol
Ethernet features Ethernet aggregation unit
GbE/10 GbE uplink Number of physical ports 12 x 10/100/1000 BaseT, RJ45 connector with Transmission range Up to 25 km MM Multi Mode
ERPS acc. ITU-T G.8032 (future release) Power over Ethernet (PoE) Options Remote powering MSP Multiplex Section Protection
LAG acc. IEEE 802.1AX (future release) Power over Ethernet According to ITU-T 802.3af and 802.3at MSTP Multiple Spanning Tree Control
Local power supply 115/230 VAC: 88 VAC … 264 VAC, 50/60 Hz
Chassis switch features Control of chassis switch Max. 84 W per module
48 VDC: - 38 VDC … - 60 VDC NE Network Element
Distributed switching architecture with centralised Max. 30 W per port (PoE+)
64 Gbps Ethernet crossbar for intermodule switching SHDSL REG SHDSL regenerator NT Network Termination
Features Member of chassis switch
RSTP, MSTP acc. IEEE 802.1W/8021Q Line code 16 Trellis coded-PAM according G.991.2 OHC Overhead Channel
Traffic protection Chassis switch features
VLAN Q-in-Q Types Indoor (IP21), outdoor (IP54), underground (IP68) OSPF Open Shortest Path First
ERPS acc. ITU-T G.8032 (future release) EPSI1 L2/L3 Ethernet
acc. IEEE 802.1ad Power options Local 48 VDC power or remote power feeding PAM Pulse Amplitude Modulation
Number of physical ports 4 x 10/100 BaseT, RJ45 connector
FAMO1 fan unit For FOX615 PDH Plesiochronous Digital Hierarchy
Number of PDH ports 64 x TDM bus access
Number of fans 10 Max. 8 x P12 (n x 64 kbit/s granularity) or Configuration and management (software packages) PoE Power over Ethernet
Operation Temperature controlled max. 16 x P12 (n x 128 kbits/s granularity) FOXCST configuration tool PPP Point to Point Protocol
PPP / MLPPP / HDLC traffic encapsulation Features Remote and local configuration
Installation Above equipment, PSTN Public Switched Telephone Network
1HU, no mechanical slot required L2-switching features According to IEEE 802.1D and 802.1Q Remote and local analysis & error detection
Traffic prioritization according to IEEE 802.1p Remote supervision PWE Pseudo Wire Emulation
FAMO2 fan unit for FOX612 Up to 8 independent switching instances RIP Routing Information Protocol
Operating system Windows® 2000, Windows® XP
Number of fans 4 L3-routing features OSPF v2 acc. RFC 2328, RIP v2 acc. RFC 2453 Windows® Vista, Windows® 7 RSTP Rapid Spanning Tree Protocol
Operation Temperature controlled Static routing, VRRP, Inter-VLAN routing Managed equipment FOX615, FOX612 Rx Receiver
Installation Above equipment, no mechanical slot required Traffic protection MLPPP, RSTP, VRRP, OSPF v2, RIP v2 FOXMAN-UN network management system SDH Synchronous Digital Hierarchy
Compatibility ETER1, LAWA4, OPTIF, DATAx, LEDS1, Features Graphical display of network SHDSL Single pair High-speed Digital Subscriber Line
DATI1 / STICx / DTM-M
Aggregate modules
Network element supervision SETS Synchronous Equipment Timing Source
Equipment protection 1+1 HW protection Fault & configuration management
SFP Small Form-factor Pluggable
Operating system Linux Red Hat
Analogue telephony modules SIP Session Initiation Protocol
Options Performance management, ITU-T G.826
SDH aggregate modules LEXI1 FXO Multiple working places SM Single Mode
SAMO1 optical/electrical SDH Main - standby solutions SNCP Sub-Network Connection Protection
Number of ports 12 x 2-wire FXO
Trail handling (networking package) SNMP Simple Network Management Protocol
Number of SDH ports 4 (2 x STM-1, 2 x STM-1/4 SFP-cage) according ITU-T Q.522 (Z-interface)
Synchronization map
SFPs available with optical LC/PC (STM-1/4) or Coding A-law according ITU-T G.711 STM Synchronous Transport Module
SNMP northbound/southbound
electrical DIN 1.0/2.3 75 Ω (STM-1) connector
Input (from exchange) - 5 ... + 4 dBr, programmable Managed equipment FOX515, FOX512, FOX615, FOX612, FOX660, STP Spanning Tree Protocol
Number of Ethernet ports 4 x 10/100/1000 BaseT
Output (to exchange) - 7.5 ... - 3 dBr, programmable ETL600, AFS670, AFR670, AG100 and other TCPAM Trellis-Coded Pulsamplitudemodulation
RJ-45 connector
equipment
SDH features 18 x 18 VC-4 HO cross connect Nominal impedance Complex or 600 Ω TDM Time Division Multiplex
36 x 36 VC-3 or 693 x 693 VC-12 LO cross connect Channel bandwidth 300 ... 3400 Hz TPE TeleProtection Equipment
Max. 64 x P12 termination to TDM BUS Signalling & functionality Seizure, ringing, ringing off, transmission of flash Tx Transmitter
Ethernet features L1-Ethernet over SDH functionality pulses, pulse dialling, DTMF without accompanying VC Virtual Container
Support of GFP / VCAT / LCAS signal, earth key, charging using 12/16 kHz pulses
VCAT Virtual Concatenation
Traffic protection SNCP / MSP for SDH traffic (intra module) LEDA1 voice and E&M
LCAS for Ethernet traffic VLAN Virtual LAN
Number of ports 8 x 2-/4-wire voice channels Note: All modules use one mechanical slot, except where otherwise stated.
SAMO2 optical/electrical SDH according ITU-T G.712 - G.715 VRRP Virtual Router Redundancy Protocol
Exeptions are the fanless modules CESM1-F, ETOP1-F and SAM02-F.
Number of SDH ports 4 (2 x STM-1/4, 2 x STM-4/16 SFP-cage) Coding A-law according ITU-T G.711
SFPs available with optical LC/PC (STM-1/4/16) or Input (from exchange) - 16.0 ... + 9.5 dBr, programmable (DEFM1, CEPI1, COSI1 available in 2014)
© ABB Switzerland Ltd, October 2013. The right to modifications or deviations due to technical progress is reserved.

electrical DIN 1.0/2.3 75 Ω (STM-1) connector


Output (to exchange) - 20.0 ... + 7.0 dBr, programmable
Number of Ethernet ports 4 x 10/100/1000 BaseT RJ-45 connector
Nominal impedance 600 Ω
SDH Features 128 x 128 VC-4 HO cross connect For more information please contact:
1008 x 1008 VC-12 LO cross connect Channel bandwidth 300 ... 3400 Hz
Max. 64 x P12 termination to TDM Bus Signalling E, M, E’, M’
80 x AU4 backplane connectivity Support of signalling types I to V ABB Switzerland Ltd
Ethernet Features Member of chassis switch Traffic protection 1+1 path protection, shared protection ring
Max 32 x EoS mappers up to 2.4 Gbps
Power Systems
Equipment protection 1+1 HW protection for voice conferences
Onboard 10 Gbps VLAN-aware switch Bruggerstrasse 72
Traffic protection SNCP/MSP for SDH traffic (inter & intra module) Features Up to 10 x voice conferences with max. 32 partici-
pants per unit 5400 Baden, Switzerland
GFP/VCAT/LCAS for EoS mappers
Chassis switch features Point-point, point-multipoint and Phone: +41 58 585 77 44
multipoint-multipoint topologies
Equipment Protection 1+1 HW Protection Fax: +41 58 585 55 77
LESU FXS E-Mail: communication.networks@ch.abb.com
Number of ports 16 x 2-wire FXS interface
according ITU-T Q.552
Coding A-law according ITU-T G.711 www.abb.communicationnetworks
1KHA - 001 212 - SEN - 10.13 - Printed in Switzerland

Input (from subscriber) - 4.0 ... + 4.0 dBr, programmable


Output (to subscriber) - 10.0 ... + 0.0 dBr, programmable
Nominal impedance Complex or 600 Ω, programmable
Channel bandwidth 300 ... 3400 Hz
Signalling & functionality V5.x, MCAS, carrier adapter, phone-exchange
Full test for subscriber lines is included
Ring over b-wire

We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice.