power supply
IEC 61000–6–2, EN 61000–6–2
3 x 10/100/1000 BaseT
GbE IEC 61000–6–4, EN 61000-6–4
power supply
GbE
2 x GbE / 10 GbE SFP
12 x alarm input IEC TS 61000–6–5
8 x 2 Mbps
1 x LCT Port IEEE 1613
CESM1 2 x alarm output
8 x 2 Mbps
U-16.2 x
8 x 2 Mbps LEDE1
Data access G.703 / G.704 1000 BASE-SX x x
1000 BASE-LX x x
8 x 2 Mbps 8 x 2 Mbps
1000 BASE-TX x x
GbE *CEPI1
GbE Circuit emulation G.703 / G.704 1000 BASE-EX x x
1000 BASE-ZX x x
3 2 x 2 Mbps
10 GBASE-LR x
GbE *COSI1
GbE Voice over IP Main FOXMAN-UN network management system features
© ABB Switzerland Ltd, October 2013. The right to modifications or deviations due to technical progress is reserved.
DSL
Chassis switch modules modules
www.abb.com/communicationnetworks
Technical data of FOX612 & FOX615
Most used SFPs also available: CWDM, DWDM; single-fiber, electrical signal
Core modules Traffic protection 1+1 path protection Transmission range Up to 25 km GbE Gigabit Ethernet
Features Member of chassis switch GFP Generic Framing Procedure
Ethernet switching and routing modules PPPoE HDLC High-Level Data Link Control
CESM1 control unit ELET1 L1/L2 Ethernet
Remote desktop modules IF InterFace
Management interfaces 10/100/1000 BaseT (IEEE 802.3) Number of physical ports 24 x 10/100/1000 BaseT, RJ45 connector
DTM-M SHDSL desktop IP Internet Protocol
DCC-interfaces Features Member of chassis switch
Number of transmission ports 1 x 1-pair or 2-pair LAG Link Aggregation
Synch I/O 2048 kHz: 2 synch inputs, 2 synch outputs Two-slot unit
Number of access ports fixed G.703/G.704 120 Ω or 1 modular inter- LCAS Link Capacity Adjustment Scheme
Alarm I/O 12 alarm inputs, 2 alarm relay outputs Traffic protection Chassis switch features
face (G.703/G.704 75 Ω, V.24, X.21/V.11, V.35, LT Line Termination
Main features Central processing unit, DCN IP routing, Ethernet ETOP1 L1/L2 Ethernet V.36, Ethernet) LTP Linear Trail Protection
crossbar, Ethernet aggregation Number of physical ports 12 x GbE, SFP based Line code 16 Trellis coded-PAM according G.991.2 MCAS Mercury-CAS
1+1 equipment protection, (warm standby)
Line rate n x 64 kbit/s duplex via 1 or 2 copper pair,
Number of Ethernet ports 3 x 10/100/1000 BaseT MCMI Modified Code Mark Inversion
Features Member of chassis switch n = 3 ... 32
2 x GbE/10 GbE, SFP + based MIB Management Information Base
Traffic protection Chassis switch features Service rate n x 64 kbit/s duplex via 1 or 2 copper pair,
1 x LCT Port
EPOI1 L2 Ethernet with PoE n = 1 ... 32 MLPPP Multi Link Point to Point Protocol
Ethernet features Ethernet aggregation unit
GbE/10 GbE uplink Number of physical ports 12 x 10/100/1000 BaseT, RJ45 connector with Transmission range Up to 25 km MM Multi Mode
ERPS acc. ITU-T G.8032 (future release) Power over Ethernet (PoE) Options Remote powering MSP Multiplex Section Protection
LAG acc. IEEE 802.1AX (future release) Power over Ethernet According to ITU-T 802.3af and 802.3at MSTP Multiple Spanning Tree Control
Local power supply 115/230 VAC: 88 VAC … 264 VAC, 50/60 Hz
Chassis switch features Control of chassis switch Max. 84 W per module
48 VDC: - 38 VDC … - 60 VDC NE Network Element
Distributed switching architecture with centralised Max. 30 W per port (PoE+)
64 Gbps Ethernet crossbar for intermodule switching SHDSL REG SHDSL regenerator NT Network Termination
Features Member of chassis switch
RSTP, MSTP acc. IEEE 802.1W/8021Q Line code 16 Trellis coded-PAM according G.991.2 OHC Overhead Channel
Traffic protection Chassis switch features
VLAN Q-in-Q Types Indoor (IP21), outdoor (IP54), underground (IP68) OSPF Open Shortest Path First
ERPS acc. ITU-T G.8032 (future release) EPSI1 L2/L3 Ethernet
acc. IEEE 802.1ad Power options Local 48 VDC power or remote power feeding PAM Pulse Amplitude Modulation
Number of physical ports 4 x 10/100 BaseT, RJ45 connector
FAMO1 fan unit For FOX615 PDH Plesiochronous Digital Hierarchy
Number of PDH ports 64 x TDM bus access
Number of fans 10 Max. 8 x P12 (n x 64 kbit/s granularity) or Configuration and management (software packages) PoE Power over Ethernet
Operation Temperature controlled max. 16 x P12 (n x 128 kbits/s granularity) FOXCST configuration tool PPP Point to Point Protocol
PPP / MLPPP / HDLC traffic encapsulation Features Remote and local configuration
Installation Above equipment, PSTN Public Switched Telephone Network
1HU, no mechanical slot required L2-switching features According to IEEE 802.1D and 802.1Q Remote and local analysis & error detection
Traffic prioritization according to IEEE 802.1p Remote supervision PWE Pseudo Wire Emulation
FAMO2 fan unit for FOX612 Up to 8 independent switching instances RIP Routing Information Protocol
Operating system Windows® 2000, Windows® XP
Number of fans 4 L3-routing features OSPF v2 acc. RFC 2328, RIP v2 acc. RFC 2453 Windows® Vista, Windows® 7 RSTP Rapid Spanning Tree Protocol
Operation Temperature controlled Static routing, VRRP, Inter-VLAN routing Managed equipment FOX615, FOX612 Rx Receiver
Installation Above equipment, no mechanical slot required Traffic protection MLPPP, RSTP, VRRP, OSPF v2, RIP v2 FOXMAN-UN network management system SDH Synchronous Digital Hierarchy
Compatibility ETER1, LAWA4, OPTIF, DATAx, LEDS1, Features Graphical display of network SHDSL Single pair High-speed Digital Subscriber Line
DATI1 / STICx / DTM-M
Aggregate modules
Network element supervision SETS Synchronous Equipment Timing Source
Equipment protection 1+1 HW protection Fault & configuration management
SFP Small Form-factor Pluggable
Operating system Linux Red Hat
Analogue telephony modules SIP Session Initiation Protocol
Options Performance management, ITU-T G.826
SDH aggregate modules LEXI1 FXO Multiple working places SM Single Mode
SAMO1 optical/electrical SDH Main - standby solutions SNCP Sub-Network Connection Protection
Number of ports 12 x 2-wire FXO
Trail handling (networking package) SNMP Simple Network Management Protocol
Number of SDH ports 4 (2 x STM-1, 2 x STM-1/4 SFP-cage) according ITU-T Q.522 (Z-interface)
Synchronization map
SFPs available with optical LC/PC (STM-1/4) or Coding A-law according ITU-T G.711 STM Synchronous Transport Module
SNMP northbound/southbound
electrical DIN 1.0/2.3 75 Ω (STM-1) connector
Input (from exchange) - 5 ... + 4 dBr, programmable Managed equipment FOX515, FOX512, FOX615, FOX612, FOX660, STP Spanning Tree Protocol
Number of Ethernet ports 4 x 10/100/1000 BaseT
Output (to exchange) - 7.5 ... - 3 dBr, programmable ETL600, AFS670, AFR670, AG100 and other TCPAM Trellis-Coded Pulsamplitudemodulation
RJ-45 connector
equipment
SDH features 18 x 18 VC-4 HO cross connect Nominal impedance Complex or 600 Ω TDM Time Division Multiplex
36 x 36 VC-3 or 693 x 693 VC-12 LO cross connect Channel bandwidth 300 ... 3400 Hz TPE TeleProtection Equipment
Max. 64 x P12 termination to TDM BUS Signalling & functionality Seizure, ringing, ringing off, transmission of flash Tx Transmitter
Ethernet features L1-Ethernet over SDH functionality pulses, pulse dialling, DTMF without accompanying VC Virtual Container
Support of GFP / VCAT / LCAS signal, earth key, charging using 12/16 kHz pulses
VCAT Virtual Concatenation
Traffic protection SNCP / MSP for SDH traffic (intra module) LEDA1 voice and E&M
LCAS for Ethernet traffic VLAN Virtual LAN
Number of ports 8 x 2-/4-wire voice channels Note: All modules use one mechanical slot, except where otherwise stated.
SAMO2 optical/electrical SDH according ITU-T G.712 - G.715 VRRP Virtual Router Redundancy Protocol
Exeptions are the fanless modules CESM1-F, ETOP1-F and SAM02-F.
Number of SDH ports 4 (2 x STM-1/4, 2 x STM-4/16 SFP-cage) Coding A-law according ITU-T G.711
SFPs available with optical LC/PC (STM-1/4/16) or Input (from exchange) - 16.0 ... + 9.5 dBr, programmable (DEFM1, CEPI1, COSI1 available in 2014)