Sei sulla pagina 1di 4

Hygiene Gauges -100mm & 150mm Dial

MODEL : HY10 (100mm Dial, Dry Case)


LFHY10 (100mm Dial, Liquid Filled Case)
HY15 (150mm Dial, Dry Case)
LFHY15 (150mm Dial, Liquid Filled Case)
Features
n Designed for pressure measurement in Sanitary application
n Designed compliance to International Dairy Federation
n Compliance to latest EN-837 standard
n Range : Refer table
n Accuracy ±1% FSD (Standard), ±0.5% FSD (on request)
n Unit of measurement - kg/cm², bar, psi, kPa
n Micrometer pointer

Hygiene Gauges designed for pressure measurement in Sanitary


application in accordance with International Dairy Federation (IDF)
requirements in pharmaceutical, dairy, biotechnology, food &
beverages industries.

Specifications Ranges
Ref. Standard EN-837 Gauge bar, kg/cm2 Least count
Dial 100 mm / 150 mm in Aluminium, white background, Compound (-)1 to 3* 0.10
black markings (-)1 to 5 0.10
Case SS304 / SS316 with bayonet bezel
(-)1 to 9 0.20
Protection IP-68 (IS:13947 part I / IEC:60529)
(-)1 to 15 0.50
Window Safety glass (Shatter proof / Toughened glass)
Diaphragm SS316L welded (-)1 to 24 0.50
Wetted Parts SS316L (-)1 to 39 1.0
Movement SS304 / SS316 Pressure 0 to 4* 0.10
Range Refer table 0 to 6 0.10
Connection Triclover / SMS union / IDF fitting 0 to 10 0.20
Filling Fluid Silicon oil / Glycerine / Food grade oil 0 to 16 0.50
Accuracy ±1% FSD (0.5% FSD on request) 0 to 25 0.50
Over range As per EN 837
0 to 40 1.0
Zero adjustment Micrometer Pointer
Blow out disc Provided (on top) * Range 0 to 4 and (-)1 to 3 are available in 2" connection only
Temperature suitability Ambient (-)4°C to 60°C, Media 150°C
Temperature Effect Within ±0.4% FSD/10°C, when temperature changes from
reference temperature of 20°C (as per EN-837 standard)
Optional NACE compliance
External Knob for zero setting
Glycerine filled case
Triclover Clamp with Gasket
SMS Male Coupling with Gasket
IDF Male Coupling with Gasket
CE
Atex

The parameters mentioned here are the standard specifications / values generally used for most of the process applications. Any other specification not
appearing here also can be provided as per customer requirement.
10/17 REV.: 00

Under Technical Collaboration with M/s. Gauges Bourdon, France


www.generalinstruments.co.in 31 www.general-gauges.com
Ordering Information

MODEL

BASIC MODEL CODE OPTION


HY10 100mm Dial, Dry Case A05 Accurcay ±0.5%FSD
LFHY10 100mm Dial, Liquid Filled Case ATX Atex
HY15 150mm Dial, Dry Case BOB Blow out disc at back
LFHY15 150mm Dial, Liquid Filled Case BSN Built In Snubber
CLB Colour Band
MOUNTING CEM CE marking
V Bottom Entry, Local Mounting
DC2 Silicone Oil filled Case
C Back Entry, Local Mounting
DUS Dual Scale
FILLING FLUID EXZ External Knob for Zero Adjustment
DC2 Silicone Oil DC-200 GLY Glycerine filled Case
GLY Glycerine VCP Vacuum Protection
VGO Food grade oil IDC IDF male coupling with gasket
Others XXX (Please Specify) SMC SMS male coupling with gasket
TCC Tri-clover clamp with gasket
CASE L Nil
S4S SS 304 ACC Accessory
S6S SS 316 XXX Other

DIAPHRAGM
S6S SS 316
UNIT
KSC kg/cm2(g)
S6L SS 316L
BAR bar(g)
WETTED PARTS PSI psi(g)
S6S SS 316 KPA kPa(g)
S6L SS 316L MPA MPa(g)
MBR mbar(g)
MOVEMENT MMW mm WC(g)
S4S SS 304
CMW cm WC(g)
S6S SS 316
MWC m WC(g)
CONNECTION INW inch WC(g)
Type Code Size Code Type Code MMH mm Hg(g)
Hygiene H 1" 25 IDF Fitting IDF CMH cm Hg(g)
Hygiene H 1-1/2" 40 SMS Union SMU INH inch Hg(g)
Hygiene H 2" 50 Tri-clover TCL XXX Other (Please specify)

e.g. For 1" Tri-clover, Code: H25TCL RANGE


Please select from Table

Sample Model Code: LFHY10-V-VGO-S4S-S6S-S6S-S4S-H40TCL-(0-10)-BAR-GLY


10/17 REV.: 00

www.generalinstruments.co.in 32 www.general-gauges.com
Hygiene Gauges - 63mm Dial

MODEL : HY63 (Dry Case)


LFHY63 (Liquid Filled Case)
Features
n Designed for pressure measurement in Sanitary application
n Designed compliance to International Dairy Federation
n Compliance to latest EN-837 standard
n Range : Refer table
n Accuracy ±2% FSD
n Unit of measurement - kg/cm², bar, psi, kPa

Hygiene Gauges designed for pressure measurement in Sanitary


application in accordance with International Dairy Federation (IDF)
requirements in pharmaceutical, dairy, biotechnology, food & beverages
industries.

Specifications Ranges
Ref. Standard EN-837 Gauge bar, kg/cm2 Least count
Dial 63 mm in Aluminium, white background, 0 to 6 0.10
black markings 0 to 10 0.20
Case SS304 / SS316
0 to 16 0.50
Protection IP-68 (IS:13947 part I / IEC:60529)
0 to 25 0.50
Window Glass
Diaphragm SS316L welded 0 to 40 1.0
Wetted Parts SS316L Note: Equivalent reading in other pressure Units
Movement SS304 / SS316 also can be provided on request
Range Refer table
Connection Triclover / SMS union / IDF fitting
Filling Fluid Silicon oil / Glycerine / Food grade oil
Accuracy ±2% FSD
Over range As per EN 837
Blow out disc Provided (on top)
Temperature suitability Ambient (-)4°C to 60°C, Media 150°C
Temperature Effect Within ±0.4% FSD/10°C, when temperature changes from
reference temperature of 20°C (as per EN-837 standard)
Optional Glycerine filled case
NACE Compliance
Triclover clamp with Gasket
SMS male coupling with Gasket
IDF male coupling with Gasket
CE

The parameters mentioned here are the standard specifications / values generally used for most of the process applications. Any other specification not
appearing here also can be provided as per customer requirement.
10/17 REV.: 00

Under Technical Collaboration with M/s. Gauges Bourdon, France


www.generalinstruments.co.in 33 www.general-gauges.com
Ordering Information

MODEL

BASIC MODEL CODE OPTION


HY63 63mm Dial, Dry Case BSN Built In Snubber
LFHY63 63mm Dial, Liquid Filled Case CLB Colour Band
CEM CE marking
MOUNTING DC2 Silicone Oil filled Case
V Bottom Entry, Local Mounting DUS Dual Scale
C Back Entry, Local Mounting GLY Glycerine filled Case
VCP Vac protection
FILLING FLUID IDC IDF male coupling with gasket
DC2 Silicone Oil DC-200
SMC SMS male coupling with gasket
GLY Glycerine
TCC Tri-clover clamp with gasket
VGO Food grade oil
L Nil
Others XXX (Please Specify)
ACC Accessory
CASE XXX Other
S4S SS 304
S6S SS 316 UNIT
KSC kg/cm2(g)
DIAPHRAGM BAR bar(g)
S6S SS 316 PSI psi(g)
S6L SS 316L KPA kPa(g)
MPA MPa(g)
MBR mbar(g)
WETTED PARTS
MMW mm WC(g)
S6S SS 316
CMW cm WC(g)
S6L SS 316L
MWC m WC(g)
INW inch WC(g)
MOVEMENT MMH mm Hg(g)
S4S SS 304 CMH cm Hg(g)
S6S SS 316 INH inch Hg(g)
XXX Other (Please specify)
CONNECTION
Type Code Size Code Type Code RANGE
Hygiene H 1" 25 IDF Fitting IDF Please select from Table
Hygiene H 1-1/2" 40 SMS Union SMU
Hygiene H 2" 50 Tri-clover TCL
e.g. For 1" Tri-clover, Code: H25TCL

Sample Model Code: LFHY63-V-VGO-S4S-S6S-S6S-S4S-H40TCL-(0-10)-BAR-GLY


10/17 REV.: 00

www.generalinstruments.co.in 34 www.general-gauges.com

Potrebbero piacerti anche